W50S6Q26QA002 RFI Questions and Answers.pdf

PDF 93 KB Posted

Attached to
Office Furniture Including Cubicle Dividers
Solicitation number
W50S6Q26QA002
Issued by

About this file

This is a Questions and Answers document for RFI W50S6Q26QA002 addressing clarifications on furniture and workstation installation requirements.

The solicitation involves furnishing and installing office cubicles, temporary workstations, and conference area furniture in a first-floor space approximately 100 feet from the truck parking location. The contractor must provide an electrician to connect powered cubicle dividers and sit-stand desks to wall junction boxes but is not responsible for connections to the electrical panel. Power is available in walls but not all cubicles are within six feet of a junction box, requiring some cubicles to use longer whips for power connections. The receiving area has a roll-up door for furniture delivery but cannot accommodate full-size semi trailers. The installation includes 20 office cubicles (66 inches tall, 7'6" x 6'6" dimensions with shared middle partition walls), 8 temporary workstations with file cabinet dividers, and lounge seating. Cubicle panels must be tackable/acoustical with metal lockers (no vents required). An 18" x 18" locker specification is substitutable with a middle-option configuration as long as shelving and doors remain accessible. The office wall lockers are slim wardrobe units with a quantity of 4, and office cubicle panels at 80" height are acceptable. The conference table must be stationary, and the modular bench requires seating only. Room dimensions are provided in the "Blueprint and Preferred Layout Labeled" file; drawings are not to scale and dimensions should be used for reference instead.

View the file

Other files

File Type Posted
B220 Addendum.xlsx XLSX spreadsheet
Lounge Seating and FIle Cabinet Locations.pdf PDF
PWS - B220 Add On Furniture.pdf PDF
B220 Addendum.xlsx XLSX spreadsheet
BluePrint and Preferred Layout LABELED.pdf PDF
B220 Addendum.xlsx XLSX spreadsheet
Solicitation - W50S6Q26QA002.pdf PDF
PWS - B220 Add On Furniture.docx DOCX document
BluePrint and Preferred Layout.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W50S6Q26QA002 – RFI Questions and Answers

1. Is the contractor responsible for providing an electrician to make connections to the powered cubicle dividers?

A. YES. CONTRACTOR WILL NEED TO PROVIDE ELECTRICIAN TO MAKE

CONNECTIONS BETWEEN FURNITURE AND WALL JUNCTION BOXES BUT WILL NOT

BE EXPECTED TO MAKE CONNECTIONS TO THE ELECTRICAL PANEL.

2. Is there currently power in the walls or floor within 6 feet of the proposed cubicle panels?

A. THERE IS POWER IN THE WALLS, BUT NOT ALL CUBICLES ARE WITHIN SIX FEET OF

A POWER JUNCTION BOX, SO SOME CUBICLES WILL REQUIRE LONGER WHIPS.

3. If the (12) cubicles on the interior of the room need to be powered from the ceiling, is there already power in the ceiling to connect to?

A. THERE IS POWER ON THE WALL. THEY WILL NOT BE POWERED FROM THE

CEILING.

4. What is the ceiling height, if power needs to come from the ceiling?

A. THERE IS POWER ON THE WALL. THEY WILL NOT BE POWERED FROM THE

CEILING.

5. Does the contractors power pole need to carry the ANG data cables?

A. THERE IS POWER ON THE WALL. THEY WILL NOT BE POWERED FROM THE

CEILING.

6. Can the powered sit stand desks have Bluetooth capability or is this a security issue?

A. NO.

7. Can the lockers in the cubicles be laminate?

A. NO. WE’RE REQUESTING METAL.

8. Do the lockers need to have vents?

A. NO.

9. Can the whiteboard be integrated into the panel system?

A. NO.

10. Do the panels need to be tackable/acoustical?

A. YES.

11. Can the panel height be 66” tall? Or 74” tall? The taller the greater the expense.

A. 66 IS FINE.

12. Requesting the interior dimensions of the main room OR the CAD file if available.

A. DIMENSIONS ARE SHOWN ON PAGE 1 OF THE FILE “BLUEPRINT AND PREFERRED

LAYOUT LEBELED”—CAD FILE CANNOT BE ATTACHED TO THE SOLICITATION.

13. Is this space located on the first floor?

A. YES.

14. Is there a loading dock available?

A. NO.

15. If no loading dock, where will we load/offload the truck?

A. THERE IS A RECEIVING AREA WITH A ROLL-UP DOOR IN WHERE THE FURNITURE

WILL BE INSTALLED. CANNOT ACCOMMODATE A FULL-SIZE SEMI TRAILER.

16. Approximately how far is it from the truck parking location to the install location?

A. APROXIMATELY 100 FT.

17. Are there any stairs that the product will need to go up or down to reach the truck location?

If so how many?

A. NO.

18. Do we have access to a passenger or a freight elevator to use for delivery to the installation location (if applicable)?

A. N/A; FIRST FLOOR

19. Office Cubicles - Is the central partition wall part of the cubicles?

A. ASSUMING THIS IS REFERRING TO THE CENTRAL SECTION OF 8 CUBICLES. THEY

WILL SHARE THE MIDDLE PARTITION WALL. CUBICLE DIMENSION WILL STILL BE

7’6” X 6’6”. THE 6’6” SIDE WILL BE THE SHARED PARTITION WALL SIDE.

20. Temporary Workstation – Does the cabinet between workstations act as a divider creating separate cubicles?

A. YES. THERE ARE 4 FILE CABINETS BETWEEN TWO CUBICLES. THE CUBICLE

COUNT WAS NOT CLEARLY DEFINED IN THE VISUAL LAYOUT BUT SPECIFIES 8

QUANTITY IN THE SPREADSHEET. I’VE ADDED DIVIDER WALLS ABOVE THE FILING

CABINETS FOR CLARITY ON THE VISUAL LAYOUT FOR A TOTAL OF 8.

21. Open Conference Area – Does the side lounge seating shown match the quantity in the specifications?

A. YES. SEE UPDATED VISUAL LAYOUT. THERE ARE 7 LOUNGE CHAIRS MATCHING

THE QUANTITY IN THE SPECIFICATIONS.

22. We note that the specifications include an 18" x 18" locker; however, this size is not available within our product offering. Would one of the alternative locker configurations shown in the attached documentation be considered an acceptable substitute?

A. MIDDLE OPTION WORKS AS LONG AS SHELVING & DOORS ARE ACCESSIBLE IN

CUBICLE CONFIGURAITON.

23. Can you confirm the drawing is not to scale and dimensions should be used instead?

A. YES. DIMENSIONS ARE SHOWN ON PAGE 1 OF THE FILE “BLUEPRINT AND

PREFERRED LAYOUT LEBELED”

24. Will the furniture vendor be in charge of hiring an electrician to connect the power from the workstations to the electrical panel?

A. YES. CONTRACTOR WILL NEED TO PROVIDE ELECTRICIAN TO MAKE

CONNECTIONS BETWEEN FURNITURE AND WALL JUNCTION BOXES BUT WILL NOT

BE EXPECTED TO MAKE CONNECTIONS TO THE ELECTRICAL PANEL.

25. Does the conference table need to be mobile?

A. NO.

26. For the modular bench, are there supposed to be tables and seating, or just seating?

A. JUST SEATING.

27. Is the wall locker for the offices a slim wardrobe unit?

A. YES.

28. Should the office wall locker quantity be 4 or 16?

A. QUANTITY SHOULD BE 4. THE ADDENDUM SPREADSHEET HAS BEEN UPDATED TO

REFLECT THIS CORRECTION.

29. Standard panel height from our manufacturer for a locking door is 80” H. Will 80” H be acceptable for the office cubicle panels?

A. YES.