A.03 Drawings (W50S8W26RA001).pdf
PDF 476 KB Posted
- Attached to
- CES - Repair Roof Bldg 37
- Solicitation number
- W508SW-26-R-A001
- Issued by
-
Department of the Army National Guard
About this file
This file contains architectural/engineering drawings for roof construction and specifications. The documents depict two roof plan views with detailed callouts for materials and construction methods, highlighted by pink/magenta borders indicating the primary roof areas under consideration.
The drawings specify a fully adhered EPDM roof system covering 10,287 square feet, with flashing at 440 feet, 2 inches in length. Key construction details include roof drains (R.D.) and overflow roof drains (O.R.D.), roof vents, mechanical roof curbs with tapered insulation for crickets on the high side, communication cable sleeves with goose neck flashing, and prefabricated metal roofing sections. Additional specifications note prefabricated metal roof sections with obstruction lights and mounts, roof hatches with high-side crimp details, fully adhered EPDM roofing with boiler flue penetrations, and tapered roof insulation for crickets leading to roof drains. The drawings include standard architectural notation symbols and reference designations that differ for upper versus lower roof materials, with a note indicating that roof materials are to be specified for both roof sections. These appear to be design or construction documents for a commercial building renovation or new construction project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A.02 SOW (W50S8W26RA001).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
File details come from the government source that posted it. Updated .