21Q0066P0001.pdf
PDF 226 KB Posted
- Attached to
- BRIAN BOILERS Federal contract opportunity
- Solicitation number
- W44W9M-21-Q-0066
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| MF715-24 - Brand Name Justification Bryan 240 HP Water Boilers (003).pdf | ||
| Solicitation.W44W9M21Q0066.BOILERS.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACTING OFFICE/JAK
JEREME A. KEMP
918-420-7425/MCALESTER CONTRACTNG
1 C TREE ROAD
MCALESTER OK 74501-9002
SEE SCHEDULE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
THE PURPOSE OF THIS AMENDMENT IS TO (1) CHANGE THE DESCRIPTION REQUIREMENTS AND QUALIFYING STATEMENT FOR CLIN0001 & CLIN0002, AND (2) EXTEND THE SOLICTION FROM: APRIL 13, 2021 @ 5:00P.M. TO: APRIL 20, 2021 @ 5:00 P.M.
1. CONTRACT ID CODE PAGE OF PAGES
1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 13-Apr-2021
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W44W9M21Q0066
X 9B. DATED (SEE ITEM 11)
06-Apr-2021
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
12-Apr-2021
CODE
CONTRACTING OFFICE
MCALESTER CONTRACTING OFFICE
1 C TREE ROAD
MCALESTER OK 74501-9002
W44W9M 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE W44W9M
FACILITY CODECODE
EMAIL:TEL:
W44W9M21Q0066
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 13-Apr-2021 05:00 PM to 20-Apr-2021 05:00 PM.
SUPPLIES OR SERVICES AND PRICES
Global Changes
CLIN 0001 -- CLIN 0002
The CLIN extended description has changed from:
MAKE:BRIAN BOILER EB-240-W MODEL: EB-240-W; PART NUMBER: HTHWEBMMLL240. BRAND
NAME ONLY- NO SUBSTITUTE. PLEASE SEE ATTACHED QUALIFYING STATEMENT.
To:
MAKE:BRIAN BOILER EB-240-W MODEL: EB-240-W; PART NUMBER: HTHWEBMMLL240FDG/O.
BRAND NAME ONLY- NO SUBSTITUTE. PLEASE SEE ATTACHED QUALIFYING STATEMENT.
The following have been modified:
QUALIFYING STATEMENT
Qualifying Statement for Medium Temperature Water Tube Boiler Scope This document provides the specifications and details for the purchase of (2) 240 HP, water in tube, dual fuel (natural gas/ diesel), medium temperature hydronic boilers with start cost and (1) UL/FM/CSD-1, RWF55 Siemens controller.
General Requirements These specifications within imply the equipment will operate inside an interior building space with adequate ventilation. Control will be an integral part of the unit to maintain a fluid temperature to supply building’s HVAC and process heat. Unit shall have all safety and overpressure valves included as delivered to work with stipulated system pressure.
Unit will be able to communicate with building software to run / shutoff, operate in fully automated mode, and to alarm building system if unit has burner faults, low water flow, high temperature, or other unit faults. Unit shall be supplied with an equipment stand or support structure than would allow unit to repose in a normal operating state on a flat reinforced concrete floor and allowing access to all maintenance or service ports.
Support structure to be designed to reduce floor contact stress to 500 psf or less for a unit in it’s flooded, operational state. Natural gas heating capacity will be assumed to be 1,023 mbtuh / cf. Pressure available to burner from facility is 3 psig at a delivery of 10,000 cfh.
Manufacturer: Bryan Boilers
Specific Requirements Quantity: 2 Units required for this application.
Model: EB-240-W Part Number: HTHWEBMMLL240FDG/O Size: 240 Horsepower (7920 BTUH) nominal output Burner Fuel: Natural Gas and diesel fuel, dual fuel with forced draft burner with 5:1 downturn minimum Electronic combustion safety control Design Flow Rate: 600 gpm.nominal.
Minimum Design Flow: 150 gpm or less..
Maximum System Pressure 150 psig Nominal Working Pressure: 100 psig Relief Valve: ASME coded- 125psi Fluid Leaving Temperature Range: 240 to 250 F.
Fluid Entering Temperature Range: 200 to 230 F.
Working Fluid: Water with consist of water solution with up to 33% Propylene glycol by volume with added corrosion inhibitors.
Thermal Efficiency: 80 % minimum Electrical: 460/3/60 Capacity of design: Less than 350 gallons flooded Design Characteristic; Flexible Boiler Tube design to warrant against thermal shock Controller Compatibility: UL/FM/CSD-1, RWF55 Siemens controller or equivalent System Unit weight: Less than 16,000 pounds Hydronic Hookup: 6”, ASME standard, 8” acceptable, 150 psi rated minimum.
Exhaust system for combustion gases shall allow for a straight 30 foot stack with capped rain guard.
Corrosion: Wet contact surfaces shall be compatible with 250 deg. F, 33 % propylene glycol solution. Manufacturer shall specify any corrosion inhibitor and it’s concentration required to maintain unit integrity during standard operating / non-operational conditions. .
Maximum dimensions:
Width: 96”: (Including tube service corridor) Height: 110” (Including support structure) Length: 280” (Including burner service corridor)
Extras:
20+ year warranty against thermal shock Temperature / Pressure Gauges: Combination or individual gauge(s) .
Auto Reset / High Limit / Low water cutoff Alarms with Audio feedback, output to building controller for individual alarms or fault detected.
Unit will have lifting lugs with a minimum design safety factor of 3.0.
Notes:
Approval drawing(s) is/are required and shall be furnished no later than two weeks after contract award.
Manuals for set-up, operation, control, trouble shooting, maintenance, and replacement part descriptions with sources shall be included with unit shipment. All orders (multiple same units orders at a time) shall include a quantity of three (3) manuals in English printed / bound.
Fuel delivered to unit: Natural gas with a lower heating value of 1,023 mbtuh / scf.
Pressure available at unit from building: 3 psig at the required delivery rate.
Acceptable Material Equivalents:
Connections will be made to existing building hydronic design consisting of carbon steel pipe per ASTM A106, Grade B.
JMMC-DES (MCAAP Support Services) will validate and verify equipment before award is granted.