This document contains the technical requirements for a federal contract opportunity to procure one CNC Vertical Knee Mill and one 18-inch Machine Lathe, along with delivery and installation at a facility located within Test Area 10 of Redstone Arsenal, AL.
The solicitation number is W31P4Q-24-Q-0013 and it is a combined synopsis/solicitation for commercial items set aside 100% for small businesses. The NAICS code is 333517 with a size standard of 500 employees. The technical requirements specify the capabilities and features required for each piece of equipment, including spindle horsepower, travel distances, RPM ranges, and explosion-proof modifications for a hazardous environment. The contract also requires the installation of remote control stations. Responses are due by 4:00 PM local time on July 31, 2024, and will be evaluated on technical capability, price, and delivery. Payment will be made through Wide Area Workflow. The contracting agency is the Department of the Army Materiel Command Contracting Command Redstone Arsenal.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL REQUIREMENTS
1.0 Description of Requirement:
The contractor shall provide the following items as specified in the table below:
Item Number Part Description Quantity 1 CNC Vertical Knee Mill (Lagun Machine Toll
Millmatic II or similar) with 3-axis control (Fagor 8058 or similar)
2 18” Machine Lathe (Lagun Mchin Tool American Turnmaster AT-1860 or similar)
Additionally, requirements for Item 1 must meet the following requirements:
• 5 HP Spindle Drive
• Table and Saddle Locks
• NMTB 40 Spindle Taper
• NMTB 40 tooling package
• 23-inch saddle
• Rapid feed for x, y and z axis
• RPM Range: 55 – 4,250
• X axis travel: 36 inches
• Z axis travel: 16 inches
• Y axis travel: 22.2 inches
• Table size: 55.25 inches x 10 inches
• Modifications for explosion proof: Class 2 Division 1 hazardous environment in accordance with DA PAM 385-64
• 3-axis control
• Local jog wheel for controls
• Remote control station for remote operation of Mill up to 150 feet from location of Mill
• internal storage for machining programs
• Large digital display
Additionally, requirements for Item 2 must meet the following requirements:
• Capacity: 18-inch diameter swing
• Distance between centers: 60 inches
• 10 HP continuous duty
• Spindle RPM Range: 17 – 1,000
• D1-8 spindle nose
• Inch-Metric Feed Box - switchable
• Leadscrew reverse
• Electric Brake
• Lathe Tracer
• Digital Readout
• Modifications for explosion proof: Class 2 Division 1 hazardous environment in accordance with DA PAM 385-64
• Local jog wheel for controls
• Remote control station for remote operation of Lathe up to 150 feet from location of
Lathe
2.0 Installation:
The Contractor will install the items listed for procurement in room 261 of Building 7347 located in Test Area 10 of Redstone Arsenal. The Contractor will install the remote-control stations for the equipment in Room 248 of Building 7347. See Attachment 1 for building layout.
3.0 Travel:
Travel is required as necessary for installation of the machinery and for on-site operator training on the machines.
4.0 Deliverables:
The above items shall be delivered to the following:
DEVCOM AvMC FCDD-AMT-MPM (Attn.) Jonathan White Building 7156 7156 Redstone Road Redstone Arsenal, AL 35898
CONTRACTORS THAT DO NOT REQUIRE CAC, BUT REQUIRE ACCESS TO A
DOD FACILITY OR INSTALLATION: Contractor and all associated sub-contractors employees shall comply with adjudication standards and procedures using the National Crime Information Center Interstate Identification Index (NCIC-III) and Terrorist Screening Database (TSDB) (Army Directive 2014-05/AR 190-13), applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative), or, at OCONUS locations, in accordance with status of forces agreements and other theater regulations.
ACCESS AND GENERAL PROTECTION / SECURITY POLICY AND PROCEDURES:
This standard language text is for contractor employees with an area of performance within an Army controlled installation, facility or area. All contractor employees, to include associated sub-contractors employees shall comply with applicable installation, facility and area Commander Installation and facility access and local security policies and procedures (provided by the Government representative). The contractor shall also provide all information required for background checks to meet installation access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. The contractor workforce shall comply with all personal identity verification requirements (CFR clause 52.204- 9, Personal Identity Verification of Contract Personnel) as directed by DoD, Department of the Army Headquarters, and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes. The prime contractor Human Resources/ Security Officer is responsible for the collection of all Redstone Badges and CAC cards issued to their employees. The Human Resources/Security Officer will then turn over these credentials to the COR. This applies when the contract expires; as well as, when a contractor resigns or is terminated. After accounting for all badges/ CACs, the COR will turn in the credentials at the One Stop Badging Office or CAC Office (MILPO). All contract employees, including subcontractor employees who are not in possession of the appropriate security clearance or access privileges, will be escorted in areas where they may be exposed to classified and/or sensitive materials and/or sensitive or restricted areas.
Building 7347 Machine Location
19 ft
9 ft
26 ft9 ft
14 ft
7 ft
3 ft
7 ft
7 ft
7 ft 25 ft
Distance to Control Room 248:
Lathe: minimum distance ~ 120 ft Mill: minimum distance ~ 100 ft
35 ft 7 ft