About this file

SPECIFICATIONS FOR HOT AIR GAS SYSTEMS SEMI-AUTOMATED

View the file

Other files for this federal contract opportunity

Other files attached to HOT GAS SYSTEM SEMI AUTOMATED, newest first.
File Type Posted
A07__7020009N-SOLICITATION.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SPECIFICATIONS

PART NUMBER

Onyx 29 Semi-Automated Hot Gas System

Including:

Seven Automated Axes (Motorized) 30mm Topside Clearance Multiple Field of View (MFOV) Vision Top/Bottom LED Lighting System (Vision) 2000 Watt Top Heater 19 x 19 inch, Four Zone Preheater Multi-Location Pick & Place Capability Precision Micro Force Table Nozzle “Cool-Air” Injection System 4 Programmable Thermocouple Channels Visual Machines Control Software Personal Computer (Windows 7, Flat Screen Monitor)

· Fully Automated Site Cleaning System

Nozzles:

NTSTD EZ Nozzle Package (14 Nozzles) CHG-Nozzles Customized Nozzle Package

Options:

Part # Description

0029.12.040 Fixed IR Sensor w/Laser Pointer

0029.02.042 Component Shuttle, Auto V2 4,400.00 Included

0029.03.012 Site Cleaning System (standard & micro nozzles)

AU6LGA47R Universal Insertion Tool (6 – 47 mm component range)

0029.00.040 Recommended Spare Parts

0029.04.044 Direct View High Definition Camera System

FASET1 Flux/Solder Paste Dipping Kit

0029.14.010 Single Arm Tool Changer with 5 pockets

300.00.547 Fume Extraction Manifold

1020.01.105 Fume Extraction System

0024.24.111 Paste-On Device-Stencil Adapter

300.00.504 4 Additional Thermocouple Ports

1015.11.076 Ultra Micro Component Rework Kit (01005, 0201, 0402, 0603) ONYX29.3YW Three (3) year Warranty Charge ONYX Configuration of Tobyhanna Military

Freight Shipping Cost Included in total cost

Installation and Training

Air-Vac personnel will provide installation and training assistance. There is no additional charge for this service.

Specifications

Machine Dimensions: 32W x 32D x 36H inches Workstation Dimensions: 62W x 44D x 55H inches Shipping Weight: 500 lbs Maximum Board Size: 20” Wide x Unlimited Depth

Facility Requirements Electrical:

Machine Power: 208 VAC, 50/60 Hz, 3-phase, 25 A (max).

6’ of 12/4 power cord supplied.

Monitor Power: (208V) - Provided by convenience plug on machine.

Computer Power: (208V) - Provided by convenience plug on machine.

Optional equipment:

Time/Pressure dispense: 110/208 VAC, 50/60 Hz, 1A/.5 A, single phase.

Air/Nitrogen (Base Machine):

Main Air Supply: 90-130 psi, 5 scfm, clean, dry air (non-condensing) source.

(Includes Board Cooling) 1/8”-18NPT with two 1/4” lines (supplied). Direct plumb.

Electrical: IMPORTANT This system is designed to operate on 208VAC, 3 phase.

Under full load conditions, power must not drop below 205VAC. Verify all 3 phases.

If the PC and monitor are connected to a separate power source, or connected through a voltage regulator, the machine minimum voltage is 195V.

Under no load conditions, power must not exceed 215VAC.

Air/Nitrogen:

With top heater and board cooling system operating, system consumes up to 25 scfm @80 psi.

With all systems activated, 70 psi. must be maintained. Requires both gas lines be direct plumbed (no quick disconnect).

General: These requirements must be addressed prior to the installation and training visit. This will assure you receive a productive training program within the scheduled installation time.

Physical:

ONYX29 Dimensions:

Base:

32W” x 32D” x 36H” Operating with workstation:

78W” x 50”D x 55”H ONYX29 Weight:

ONYX29 (265 lbs.)

with workstation (365 lbs.)

Shipment

Container size is too large for shipment by UPS.

Warranty

Three (3) years from date of shipment on all parts and labor excluding consumable items such as light bulbs, hoses and heating elements. Limit of four (4) service visits under Warranty during years two and three combined.

Payment Terms

WIDE AREA WORKFLOW (WAWF)

TOTAL PACKAGE COST ________________________________

File details come from the government source that posted it. Updated .