This document is a Custodial Service Plan for the Caven Point USARC facility located at 2 Caven Point Road, Jersey City, NJ. The plan provides detailed floor layouts and custodial service requirements for two main buildings: the USARC Building and the OMS Building.
The USARC Building contains approximately 31,860 square feet across two floors requiring custodial service totaling 15,930 SF on the first floor and an equivalent area on the second floor. Custodial fixtures requiring service include 4 water fountains, 10 toilet tissue dispensers, 10 soap dispensers, 10 paper towel dispensers, 5 urinals, 14 sinks, 20 showers, and 15 commodes throughout the building. The facility features various room types including classrooms (439 SF each), unit storage areas (ranging from 1,238 to 5,222 SF), a physical readiness room (2,977 SF), assembly area (2,976 SF), arms vault (1,320 SF), locker rooms, showers, and administrative offices. Floor surfaces requiring custodial attention include ceramic tile (2,530 SF total), VCT (6,844 SF total), and carpet (6,556 SF total). The OMS Building requires significantly less custodial service at 594 SF, with fixtures including 3 commodes, 4 sinks, 2 urinals, 3 toilet tissue dispensers, and 2 soap dispensers. The OMS facility contains a work bay (4,538 SF), tool room (935 SF), and various support spaces with 244 SF of VCT and 350 SF of ceramic tile flooring. All plans are dated 05MAR2026 and were field-verified by LC.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
439 SF
128B
CLASSROOM
439 SF
128A
CLASSROOM
130 SF
ELEC
439 SF
CLASSROOM
439 SF
CLASSROOM
1,577 SF
READINESS ROOM
PHYSICAL
2,977 SF
UNIT STORAGE
931 SF
WEAPON SIMULATOR
580 SF
TEAM ROOM
83 SF
JANITOR
239 SF
SUPPORT
FAMILY
354 SF
OFFICE
240 SF
OFFICE
RETENTION
REC/
123 SF
ELEC
493 SF
MECH
346 SF
102A
OFFICE
134 SF
102B
OFFICE
134 SF
OFFICE
303 SF
VEST
81 SF
MAIN TR
2,976 SF
ASSEMBLY
374 SF
MECH
167 SF
ELEC
161 SF
TR
246 SF
STORAGE
CHAIR
591 SF
STORAGE
172 SF
1,320 SF
ARMS VAULT
130 SF
ARMORER
133 SF
OFFICE
SUPPLY
138 SF
OFFICE
SUPPLY
131 SF
OFFICE
SUPPLY
136 SF
OFFICE
SUPPLY
130 SF
OFFICE
SUPPLY
135 SF
OFFICE
SUPPLY
1,238 SF
UNIT STORAGE
3,923 SF
UNIT STORAGE
1,757 SF
RECEIVING
UNIT STORAGE
5,222 SF
UNIT STORAGE
563 SF
MEN'S LOCKER ROOM
254 SF
LOCKER
WOMEN'S 361 SF
TOILET
MEN'S
280 SF
TOILET
WOMEN'S
36 SF
119A
VEST
58 SF
115A
VEST
125 SF
STAIR D
31 SF
ELEV
280 SF
MEN'S SHOWER
134 SF
SHOWER
WOMEN'S
(W.F.)
199 SF
TOILET
MEN'S
164 SF
TOILET
WOMEN'S
586 SF
KITCHEN
30 SF
CLOSET
DRINK
131 SF
SCULLERY
96 SF
STAIR B
UP
262 SF
STAIR A
UP
UP
DN
129 SF
STAIR C
DN
UP
CERAMIC
CERAMIC
CERAMIC
CERAMIC
CERAMIC
CERAMIC
CARPET
CARPET
CARPET
CARPET
CARPET
687 SF
CORR
VCT
VCT
351 SF
CORR
VCT
477 SF
CORR
VCT
1,223 SF
CORR
VCT
84 SF
CORR
VCT
CARPET
CERAMIC
CERAMIC
CERAMIC
CERAMIC
VCT
VCT
VCT
VCT
N
FIRST FLOOR CUSTODIAL SERVICE PLAN - USARC
SCALE: 1/16" = 1'-0"
0 4' 8' 16' 32'
SERVICE: 15,930 SF
REQUIRING CUSTODIAL
BUILDING TOTAL AREA
WATER FOUNTAIN:
TOILET TISSUE DISPENSERS:
SOAP DISPENSERS:
PAPER TOWEL DISPENSERS:
URINALS:
SINKS:
SHOWERS:
COMMODES:
CUSTODIAL SERVICE
FIXTURES REQUIRING
CUSTODIAL SERVICE
FIXTURES REQUIRING
FLOOR
FIRST
FLOOR
FIRST
TOTAL
BUILDING
TOTAL
BUILDING
NOT SERVICED
SLATE/ STONE
WOOD
CERAMIC TILE
SPORT RUBBER
VCT
CARPET
CONCRETE
N/A
N/A
N/A
2,329
N/A
3,768
5,551
N/A
FLOOR SF
FIRST
FLOOR SF
FIRST
N/A
N/A
N/A
2,530
N/A
6,844
6,556
N/A
TOTAL SF
BUILDING
TOTAL SF
BUILDING
DPW - CAD DESIGN TEAM
99th READINESS DIVISION
UNCLASSIFIED
NJ008 (34915)/ USARC BUILDING
CAVEN POINT USARC
CUSTODIAL SERVICE PLAN
JERSEY CITY, NJ
2 CAVEN POINT ROAD
SHEET: 1 OF 3CHECKED: SSDRAWN: JC
FIELD VERIFIED: LC DATE: 05MAR2026
179 SF
OFFICE
310 SF
OFFICE
239 SF
OFFICE
240 SF
OFFICE
153 SF
TR
178 SF
OFFICE
230 SF
OFFICE
230 SF
ROOM
BREAK
127 SF
ROOM
LACTATION
133 SF
OFFICE
130 SF
OFFICE
130 SF
OFFICE
129 SF
OFFICE
128 SF
OFFICE
128 SF
OFFICE
129 SF
OFFICE
130 SF
OFFICE
130 SF
OFFICE
133 SF
OFFICE
133 SF
OFFICE
133 SF
OFFICE
133 SF
OFFICE
98 SF
OFFICE
105 SF
OFFICE
90 SF
TR
112 SF
OFFICE
133 SF
OFFICE
133 SF
OFFICE
133 SF
OFFICE
439 SF
CENTER
LEARNING
439 SF
OFFICE
439 SF
OFFICE
439 SF
TEAM ROOM
130 SF
ELEC
86 SF
STOR
MAINT
FAC
DN
ELEV
99 SF
STAIR B
262 SF
STAIR A
DN
87 SF
TOILET
WOMEN'S
114 SF
TOILET
MEN'S
18 SF
382 SF
ELEV LOBBY
125 SF
STAIR C
125 SF
STAIR D
DN
DN
CERAMIC
CERAMIC
CARPET
CARPET
VCT
505 SF
CORR
VCT
3,368 SF
ADMIN COMMON
3,361 SF
ADMIN COMMON
477 SF
CORR
VCT
763 SF
CORR
VCT
108 SF
CORR
VCT
BELOW
ROOF
VCT
VCT
VCT
N
SECOND FLOOR CUSTODIAL SERVICE PLAN - USARC
SCALE: 1/16" = 1'-0"
0 4' 8' 16' 32'
SERVICE: 15,930 SF
REQUIRING CUSTODIAL
BUILDING TOTAL AREA
WATER FOUNTAIN:
TOILET TISSUE DISPENSERS:
SOAP DISPENSERS:
PAPER TOWEL DISPENSERS:
URINALS:
SINKS:
SHOWERS:
COMMODES:
N/A
CUSTODIAL SERVICE
FIXTURES REQUIRING
CUSTODIAL SERVICE
FIXTURES REQUIRING
FLOOR
SECOND
FLOOR
SECOND
TOTAL
BUILDING
TOTAL
BUILDING
NOT SERVICED
SLATE/ STONE
WOOD
CERAMIC TILE
SPORT RUBBER
VCT
CARPET
CONCRETE
N/A
N/A
N/A
N/A
3,076
1,005
N/A
FLOOR SF
SECOND
FLOOR SF
SECOND
N/A
N/A
N/A
2,530
N/A
6,844
6,556
N/A
TOTAL SF
BUILDING
TOTAL SF
BUILDING
UNCLASSIFIED
NJ008 (34915)/ USARC BUILDING
CAVEN POINT USARC
CUSTODIAL SERVICE PLAN
JERSEY CITY, NJ
2 CAVEN POINT ROAD
SHEET: 2 OF 3CHECKED: SSDRAWN: JC
935 SF
TOOL ROOM
4,538 SF
WORK BAY
122 SF
OFFICE
118 SF
OFFICE
633 SF
MECH
141 SF
ELEC
112 SF
TELE 423 SF
ADMIN
SHOP
222 SF
STOR
FLAM
397 SF
WASTE
CONT
282 SF
ALCOVE
EQUIP
2,986 SF
STORAGE
UNHEATED
51 SF
VEST
24 SF
JAN
179 SF
MEN'S
171 SF
WOMEN'S
VCT
CERAMIC
CERAMIC
193 SF
CORR
SERVICE: 594 SF
REQUIRING CUSTODIAL
BUILDING TOTAL AREA
WATER FOUNTAIN:
TOILET TISSUE DISPENSERS:
SOAP DISPENSERS:
PAPER TOWEL DISPENSERS:
URINALS:
SINKS:
SHOWERS:
COMMODES:
CUSTODIAL SERVICE
FIXTURES REQUIRING
CUSTODIAL SERVICE
FIXTURES REQUIRING
TOTAL
BUILDING
TOTAL
BUILDING
NOT SERVICED
SLATE/ STONE
WOOD
CERAMIC TILE
SPORT RUBBER
VCT
CARPET
CONCRETE
N/A
N/A
N/A
N/A
N/A
N/A
TOTAL SF
BUILDING
TOTAL SF
BUILDING
CUSTODIAL SERVICE PLAN - OMS
SCALE: 1/16" = 1'-0"
N0 4' 8' 16' 32'
UNCLASSIFIED
NJ008 (34915)/ OMS BUILDING
CAVEN POINT USARC
CUSTODIAL SERVICE PLAN
JERSEY CITY, NJ
2 CAVEN POINT ROAD
*DRAFT* SHEET: 3 OF 3CHECKED: SSDRAWN: JC
| NJ008_CUST_01_USARC 1stFloor_MAR2026_UNCLASSFIED |
| NJ008_CUST_02_USARC 2ndFloor_MAR2026_UNCLASSFIED |
| NJ008_CUST_03_OMS_MAR2026_UNCLASSFIED |