Text version

Batch: 42405

165 New Boston St., Ste 227 Woburn, MA 01801

781-932-9600 Web: www.asbestosidentificationlab.com

Email: mikemanning@asbestosidentificationlab.com

Asbestos Identification Laboratory

Dear Anne (Fardy) MacMillan , Thank you Anne (Fardy) MacMillan for your business.

Michael Manning Owner/Director

Asbestos Identification Laboratory has completed the analysis of the samples from your office for the above referenced project .

The information and analysis contained in this report have been generated using the EPA /600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. Materials or products that contain more than 1% of any kind or combination of asbestos are considered an asbestos containing building material as determined by the EPA. This Polarized Light Microscope (PLM) technique may be performed either by visual estimation or point counting. Point counting provides a determination of the area percentage of asbestos in a sample. If the asbestos is estimated to be less than 10% by visual estimation of friable material, the determination may be repeated using the point counting technique. The results of the point counting supersede visual PLM results. Results in this report only relate to the items tested. This report may not be used by the customer to claim product endorsement by NVLAP or any other U.S. Government Agency.

Laboratory results represent the analysis of samples as submitted by the customer. Information regarding sample location, description, area, volume, etc., was provided by the customer. Asbestos Identification Laboratory is not responsible for sample collection activities or analytical method limitations. Unless notified in writing to return samples, Asbestos Identification Laboratory discards customer samples after 30 days. Samples containing subsamples or layers will be analyzed separately when applicable. Reports are kept at Asbestos Identification Laboratory for three years. This report shall not be reproduced, except in full, without the written consent of Asbestos Identification Laboratory.

Work Received:

2019-05-08 2019-05-08

Fort Devens 041019 Anne (Fardy) MacMillan Bluestone Environmental Group 675 Lancaster Avenue Berwyn, PA 19312

2019-05-07

Project Number:

Project Name:

May 09, 2019

Date Sampled:

Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116

Work Analyzed:

• NVLAP Lab Code: 200919-0

• Massachusetts Certification License: AA000208

• State of Connecticut, Department of Public Health Approved Environmental Laboratory Registration Number: PH-0142

• State of Maine, Department of Environmental Protection Asbestos Analytical Laboratory License Number: LB-0078(Bulk) LA-0087(Air)

• State of Rhode Island and Providence Plantations. Department of Health Certification: AAL-121

• State of Vermont, Department of Health Environmental Health License AL934461

Work Received:

2019-05-08 2019-05-08

Fort Devens 041019 Anne (Fardy) MacMillan Bluestone Environmental Group 675 Lancaster Avenue Berwyn, PA 19312

2019-05-07

Project Number:

Project Name:

May 09, 2019

Date Sampled:

Analysis Method: BULK PLM ANALYSIS EPA/600/R-93/116

Work Analyzed:

Asbestos % Material Color Non-Asbestos % Location FieldID

LabID Detected Anthophylite 5 multi Cellulose 2 Non-Fibrous 93

472165

A01A Trailer WallInsulation Wallboard

Detected Anthophylite 5 multi Cellulose 2 Non-Fibrous 93

472166

A01B Trailer WallInsulation Wallboard gray Cellulose 5 Non-Fibrous 95

472167

A02A TrailerFloor Tiles None Detected gray Cellulose 5 Non-Fibrous 95

472168

A02B TrailerFloor Tiles None Detected white Fiberglass 2 Cellulose 5 Non-Fibrous 93472169

A03A TrailerCeiling Materials None Detected white Fiberglass 2 Cellulose 5 Non-Fibrous 93472170

A03B TrailerCeiling Materials None Detected tan Non-Fibrous 100

472171

A04A Building #616 Storage Closet

Tan Mastic None Detected tan Non-Fibrous 100

472172

A04B Building #616 Storage Closet

Tan Mastic None Detected multi Non-Fibrous 100

472173

A05A Building #616 Storage Closet

White Tile None Detected multi Non-Fibrous 100

472174

A05B Building #616 Storage Closet

White Tile None Detected multi Non-Fibrous 100

472175

A06A Buildng #656 Conference Room

Black Mastic None Detected multi Non-Fibrous 100

472176

A06B Buildng #656 Conference Room

Black Mastic None Detected

Analyzed by: 42405Batch:

Page 1 of 1Thursday 09 May End of Report