C
A
D
D
C
B
A
CONTRACT NUMBER
CAGE CODESIZE
SCALE UNIT WT.
DESIGN ACTIVITY
CONTRACTOR
DRAWN BY DATE(YEAR-MO-DA)
CHECKER ENGINEER
ENGINEER QUALITY ENGINEER
DRAWING APPROVAL
DESIGN APPROVAL
B
MODELED BYMATL ENGR
SHEET
FORMAT: C_TACOM_MET_1_0
TOLERANCES ON ANGLES �#� �$�
0 PLACE DECIMALS �#�
1 PLACE DECIMALS �#�
DRAWING SIZE C
DWG NO.
2X 110
35�$�
1 OF 1 5/16
130751016KX34C
LAMP ALLOWABLE
VOLUME
2018-06-22K RICHARDS
2018-06-22C SANKOVICH
S ROSEB CONNAIR
2018-06-22C SANKOVICH
B CONNAIR
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN MILLIMETERS
DO NOT SCALE DRAWING
METRIC
APPLICATION
USED ONNEXT ASSY
PMIC
MECHANICAL
PROPERTIES
YP
TS
EL2
RA
BH
RH
REVISIONS
APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONDRAW REVMODEL REV
PART NO. 13075101
THIS DRAWING WAS GENERATED FROM A SOLID MODEL
AND IS CAD MAINTAINED. CHANGES SHALL BE
INCORPORATED BY THE DESIGN ACTIVITY.
NSN
1 OF 10.000 5/16
130751016KX34C
LAMP ALLOWABLE
VOLUME
US ARMY
PROJECT MANAGER SOLDIER WEAPONS
PICATINNY ARSENAL, NEW JERSEY 07806-5000
2018-06-22K RICHARDS
2018-06-22C SANKOVICH
S ROSEB CONNAIR
2018-06-22C SANKOVICH
B CONNAIR
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN MILLIMETERS
DO NOT SCALE DRAWING
METRIC
APPLICATION
USED ONNEXT ASSY
PMIC
MECHANICAL
PROPERTIES
YP
TS
EL2
RA
BH
RH
REVISIONS
APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONDRAW REVMODEL REV
PART NO. 13075101
THIS DRAWING WAS GENERATED FROM A SOLID MODEL
AND IS CAD MAINTAINED. CHANGES SHALL BE
INCORPORATED BY THE DESIGN ACTIVITY.
NSN
FRONT
NOTES:
1. APPLICABLE STANDARDS/SPECIFICATIONS:
A. ASME Y14.100 - 2017
2. THE DIMENSIONS SPECIFIED IN THIS DRAWING IDENTIFIES
THE MAXIMUM PERMISSIBLE VOLUME WHICH IS TO SERVE
AS DESIGN GUIDANCE FOR A REMOTE WEAPON STATION
WARNING AND SEARCH LAMP.
3. MAJOR COMPONENTS OF THE LAMP TO INCLUDE MOUNTING
INTEFACES SHALL BE CONTAINED WITHIN THIS VOLUME.
4. AN INTEGRATED CABLE IS NOT REQUIRED TO BE CONTAINED
IN THIS VOLUME.
DISTRIBUTION STATEMENT A -
APPROVED FOR PUBLIC RELEASE
SECTION A-A
SCALE 5/16
FRONT