Attachment_2_-_SCW_Test_Plan_Outline.xlsx

XLSX spreadsheet 15 KB Posted

Attached to
Prototype Opportunity Notice (PON) for Sub Compact Weapon (SCW) System Federal contract opportunity
Solicitation number
W15QKN-18-R-032M
Issued by
Department of the Army Materiel Command Contracting Command Picatinny Arsenal

About this file

Attachment 2 - Test Plan Outline

View the file

Other files for this federal contract opportunity

Other files attached to Prototype Opportunity Notice (PON) for Sub Compact Weapon (SCW) System, newest first.
File Type Posted
SCW_Prototype_Opportunity_Notice_Amended.pdf PDF
Attachment_1_-_SCW_Proposal_Form_Rev_1.xlsx XLSX spreadsheet
SCW_Prototype_Opportunity_Notice.pdf PDF
Attachment_1_-_SCW_Proposal_Form.xlsx XLSX spreadsheet

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Capability 1-9 Test Plan Outline

Sub-Compact Weapon

SubtestWpns Reqd.Rds per Wpn.Total Rds.Remarks
Inspection1530300
Reliability36,00018,000
High Temperature35001,50010 x 50 rd cycles @ +160F
Accuracy-Dispersion31504505 x 5 round targets at 35m and 50m ranges.
Recoil120
Noise15
Accessory Compatibility1Suppressor, sling, etc.
Rough Handling1305' drop test, 6 orientations
Limited User Evaluation5@ ARL-HRED with ATC support
Low Temperature35001,50010 x 50 round cycles @ -50F
Cook Off11,100Target = 210 rounds without Cook Off
Toxic Fumes1120

Total Rounds: 23,025

Capability 10

Sub-Compact Weapon - User in the Loop Testing

Prototype/Soldier Test ParametersCapabilityWeapons Required (1)Rounds per WeaponRemarks
Measuring performance against the shooter in the loop accuracy requirement in the draft CDD (2)Controllability (2)550Controllability will be assessed based on user in the loop accuracy
Recoil (2)5Assessed during controllability event.
Trigger5Assessed during controllability event. (3)
Sight-Ability and Access to Controls during a series of operationally realistic engagements550Depending on soldier availability and range configuration, round count may vary. (3)
Evaluating risk of user acceptance based on usability in operationally relevant scenarios.Weapon Comfort50No firing required
Concealability50No firing required
Maintainability530Ammunition may be used, but there will be no firing required
Ease of Magazine Change550Initial magazine will be the 20-rd magazine. Second magazine will be the 30-rd magazine.

No firing required

Notes:
(1) The same five weapons will be used for all events.
(2) Dependent upon safety release being issued.
(3) If circumstances dictate no firing of the weapon, this assessment will be conducted without ammunition.