These engineering design and site plan documents detail the construction plans for the Veterans Park Memorial project located at 2651 N. Roadrunner Parkway in Las Cruces, New Mexico. The documents include civil site plans, demolition plans, grading plans, and structural foundation details for a memorial site featuring a Huey helicopter monument. The project involves preparing a 9-acre lot within the Veterans Park Subdivision, with specific focus on clearing areas, excavating, and constructing a precise circular monument foundation. The plans include detailed site location maps, demolition and new construction strategies, and technical specifications for a 12-foot diameter spot footing that is 10'-6" deep, along with associated concrete sidewalks and steel post mounting infrastructure.
The design documents demonstrate extensive site engineering considerations, including precise elevation measurements, contour interval tracking, and careful storm water management. Technical specifications outline rigorous construction requirements such as utility location protocols, pedestrian safety considerations, and specific compaction and structural steel guidelines. The structural plans include detailed reinforcement steel specifications, concrete placement instructions, and precise measurements for the monument's foundation, indicating a carefully planned and engineered memorial installation that requires significant technical expertise and precision in execution.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N59°51'50"E
91.97'
S30°08'10"E 384.34'
S30°08'10"E 314.76'
S59°51'51"W
100.00'
S88°12'12"W 213.49'
S79°51'50"W 430.00'
N30°08'09"W 135.93'
N30°08'09"W 314.75'
ROADRUNNER PARKW
AY
120' R-O-W
EXISTING PARKING
100.00' (4154.22)
BENCHMARK
4155.00'
FG
4155.00'
FG
4143.98'
FG
4143.75'
FG (4154.41)
MATCH EXISTING
(4154.80)
MATCH EXISTING
4151.80'
FG
4151.80'
FG
4151.50'
FG
4151.80'
FG
4151.50'
FG
AS
SO
CI
AT
E
NA
ME
A
ND
A
DD
RE
SS
FI
RM
N
AM
E
AN
D
AD
DR
ES
S:
REVISIONS / COMMENTS:
LOCATION / ADDRESS:
PR
OJ
EC
T
TI
TL
E:
SEAL / STAMP:
DRAWN BY:
DATE:
DWG. FILE:
SHEET TITLE:
PROJECT #:
SCALE:
"AS NOTED"
T. SOTOMAYOR
09/30/15
VVM-CONST-OPT-2-CIVIL SITE.dwg
SHEET NO:
C-101
SITE LOCATION MAP
SCALE: 1" = 50'-0"
DEMOLITION PLAN
SCALE: 1" = 10'-0"
CLEARING AREA FOR NEW
CONSTRUCTION
EXISTING GROUNDCOVER
GRASS
EXISTING GROUNDCOVER3/4
TO 1 1/4 LOOSE ROCK
EXISTING NATURAL
VEGETATION
HATCHING LEGEND
PROPERTY LOT & BLOCK DESCRIPTION
A 9.00 ACRE LOT LOCATED WITH IN THE
"VETERANS PARK SUBDIVISION" LOCATED
WITH IN THE HIGH RANGE PLANNED
COMMUNITY DISTRICT PROJECTED
SECTIONS 4 & 5, T 23S,.R 2E,
0901-01-JOE MARTINEZ-VET PARK
NOTE: EXISTING CONTOUR INTERVALS @ 1'-0"
LAS CRUCES, NEW MEXICO
VETERANS PARK
2651 N. ROADRUNNER PARKWAY
88011
NEW CLEARING AREA
DEMOLITION LEGEND
NOTE: EXISTING CONTOUR INTERVALS @ 0'-6"
LOCATION LINE TO CENTER
OF NEW STRUCTURE
NEW CONSTRUCTION LIMITS
NEW EXCAVATION
BOUNDARY. (APPROXIMATE)
CENTER OF NEW MONUMENT
4155.00'
FG
4155.00'
FG
4143.98'
FG
4143.75'
FG (4154.41)
MATCH EXISTING
(4154.80)
MATCH EXISTING
4151.80'
FG
4151.80'
FG
4151.50'
FG
4151.80'
FG
4151.50'
FG
AS
SO
CI
AT
E
NA
ME
A
ND
A
DD
RE
SS
FI
RM
N
AM
E
AN
D
AD
DR
ES
S:
REVISIONS / COMMENTS:
LOCATION / ADDRESS:
PR
OJ
EC
T
TI
TL
E:
SEAL / STAMP:
DRAWN BY:
DATE:
DWG. FILE:
SHEET TITLE:
PROJECT #:
SCALE:
"AS NOTED"
T. SOTOMAYOR
09/30/15
VVM-CONST-OPT-2-CIVIL SITE.dwg
SHEET NO:
C-102
NEW CONSTRUCTION PLAN
SCALE: 1" = 10'-0"
GRADING PLAN NOTES:
1. BEFORE YOU DIG PLEASE CALL NMOC AT 1-800-321-ALERT
2. ALL EXISTING UTILITIES SHALL BE LOCATED AND
FLAGGED PRIOR TO ANY EXCAVATION OR GRADING.
3. PROJECT BENCHMARK/TIE-IN IS LOCATED AT THE SOUTH
END OF THE EXISTING CONCRETE SIDEWALK. EXISTING
ELEVATION 4154.22' = 100.00'(100'-0")
4. ALL STORM WATER RUNN-OFF SHALL BE DIRECTED TO
CENTER OF MONUMENT AND OUT ENTRANCE OF
MONUMENT. NO ACCUMULATION OF STORM WATER
RUN-OFF SHALL BE LOCATED IN PATHWAY OF
PEDESTRIAN TRAFFIC..
5. EXISTING CONTOUR INTERVAL EQUALS 0'-6".
6. CONTRACTOR IS RESPONSIBLE FOR COORDINATING
SAFETY FOR PEDESTRIAN TRAFFIC DURING DEMOLITION
AND CONSTRUCTION.
0901-01-JOE MARTINEZ-VET PARK
NEW GRADING PLAN
SCALE: 1" = 10'-0"
NEW CONSTRUCTION PLAN NOTES:
1. MONUMENT LOCATION PLAN ONLY. SEE STRUCTURAL SHEETS FOR
SPECIFIC DIMENSIONS ON NEW WALL DEMENSIONS & CONCRETE.SLAB
DEMENSIONS
2. EXISTING "VETERANS MEMORIAL PATHWAY" SIGNAGE LOCATED AT
EXISTING CONCRETE SIDEWALK & PAVEMENT PATHWAY, SHALL NOT BE
DISTURBED.
BENCHMARK
102'-0"
MATCH EXISTING
101'-2"
FG
99'-4"
TOC
GRADING LEGEND
EXISTING BENCHMARK
MATCH EXISTING TIE-IN
HIGH POINT & TOP OF
CONCRETE
TOP OF CONCRETE
FINISH GRADE
FLOW ARROWS - NEW
LAS CRUCES, NEW MEXICO
VETERANS PARK
2651 N. ROADRUNNER PARKWAY
88011
99'-4"
HP/TOC
FLOW ARROWS - EXISTING
COUNTOURS - EXISTING
6" INTERVALS
COUNTOURS - NEW
6" INTERVALS
BENCHMARK
100 (4155'-0")
BENCHMARK
12'Ø DIA. x 10'-6"DEEP
SPOT FOOTING- PLAN VIEW
SCALE: 1/2" = 1'-0"
1' 2'0 4'
12'Ø DIA. x 10'-6"DEEP
SPOT FOOTING- SECTION VIEW
SCALE: 1/2" = 1'-0"
1' 2'0 4'
S-1
S-1
3'x18"x3' PEDESTAL- CROSS-SECTION
SCALE: 1/2" = 1'-0"
1' 2'0 4'
S-1
3'x18"x3' PEDESTAL- CROSS-SECTION
SCALE: 1/2" = 1'-0"
1' 2'0 4'
HSS 18"Ø x 1/2" THICK.- SHOP DRAWING
SCALE: 1/2" = 1'-0"
1' 2'0 4'
S-1
6' CONCRETE SIDEWALK
SCALE: 1/2" = 1'-0"
1' 2'0 4'
AS
SO
CI
AT
E
NA
ME
A
ND
A
DD
RE
SS
FI
RM
N
AM
E
AN
D
AD
DR
ES
S:
REVISIONS / COMMENTS:
LOCATION / ADDRESS:
PR
OJ
EC
T
TI
TL
E:
SEAL / STAMP:
DRAWN BY:
DATE:
DWG. FILE:
SHEET TITLE:
PROJECT #:
SCALE:
"AS NOTED"
T. SOTOMAYOR
09/30/15
VVM-CONST-OPT-2-FOOTING DETAILS.dwg
SHEET NO:
S-101
POST FOUNDATION &
STEEL POST
0901-01-JOE MARTINEZ-VET PARK
LAS CRUCES, NEW MEXICO
VETERANS PARK
"BATAAN MEMORIAL PARK"
88011
File details come from the government source that posted it. Updated .