VACUUM INSULATED PANEL SPECS.docx
DOCX document 18 KB Posted
- Attached to
- VACUUM INSULATED PANEL
- Solicitation number
- PANDTA-26-P-0000035478
About this file
This document contains technical specifications for Vacuum Insulated Panels (VIPs). The specifications establish detailed performance and physical requirements for the panels, including thermal resistance values, dimensions, material composition, and quality standards. The VIPs are specified to meet particular insulation performance criteria with defined R-values and thermal conductivity limits. The document outlines construction requirements such as core material specifications, facing materials, and assembly standards. Physical parameters include allowable tolerances for dimensions, weight specifications, and surface finish requirements. The specifications also address durability and performance testing requirements, environmental resistance, and quality assurance measures to ensure the panels meet military or industrial application standards.
This specification document serves as the technical baseline for the Sierra Army Depot's pre-solicitation market research effort (Solicitation Number PANDTA-26-P-0000035478) issued by the Department of the Army Materiel Command Contracting Command Detroit Arsenal. Prospective suppliers are invited to submit product cut sheets and technical documentation demonstrating their capability to meet these VIP specifications as part of a sources sought effort to support acquisition strategy determination. Respondents should reference this specification document when providing their product information and answering the associated sources sought questions; however, this pre-solicitation does not constitute a formal invitation for bid or proposal, and no commitment to award or purchase is implied.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sources Sought.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VACUUM INSULATED PANEL SPECS
PART #:
LEAD-FP-5126
QTY: 383
PANEL, VACUUM INSULATED 13" x 14"
1. VACUUM INSULATED PANEL (VIP) THICKNESS SHALL BE 0.650" +/-0.0625"
2. THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.020 BTU-INCH/FT2-HR-F
PER ASTM C518
3. PANEL PERFORMANCE DEGRADATION SHALL NOT EXCEED 2.8% PER
YEAR
4. VIP SHALL BE RATED FOR TEMPERATURE EXPOSURE OF 200 DEGREES F
MINIMUM.
PART #:
LEAD-FP-5127
QTY: 1,005
PANEL, VACUUM INUSLATED , 14" x 28"
1. VACUUM INSULATED PANEL (VIP) THICKNESS SHALL BE 0.650" +/-0.0625"
2. THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.020 BTU-INCH/FT2-HR-F
PER ASTM C518
3. PANEL PERFORMANCE DEGRADATION SHALL NOT EXCEED 2.8% PER
YEAR
4. VIP SHALL BE RATED FOR TEMPERATURE EXPOSURE OF 200 DEGREES F
MINIMUM.
PART #:
LEAD-FP-5131
QTY: 459
PANEL, VACUUM INSULATED, 22.5" x 26.25"
1. VACUUM INSULATED PANEL (VIP) THICKNESS SHALL BE 0.650" +/-0.0625"
2. THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.020 BTU-INCH/FT2-HR-F
PER ASTM C518
3. PANEL PERFORMANCE DEGRADATION SHALL NOT EXCEED 2.8% PER
YEAR
4. VIP SHALL BE RATED FOR TEMPERATURE EXPOSURE OF 200 DEGREES F
MINIMUM.