The file's text, extracted by GovTribe without its formatting.
Sources Sought Notice
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 21703 |
| SOLICITATION NUMBER* |
| 36C10X26Q0268 |
| RESPONSE DATE/TIME/ZONE |
| 09-18-2026 0900 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 60 DAYS AFTER THE RESPONSE DATE |
| PRODUCT SERVICE CODE* |
| 6515 |
CONTRACTING OFFICE ADDRESS
Enterprise Procurement Office Department of Veterans Affairs 5202 Presidents Court, Suite 103 Frederick MD 21703
POINT OF CONTACT*
Contracting Officer Kimberly LeMieux Kimberly.LeMieux@va.gov
PLACE OF PERFORMANCE
POSTAL CODE
COUNTRY
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| VA | OALC | OPAL | EPO |
| AGENCY CONTACT’S EMAIL ADDRESS |
| Kimberly.LeMieux@va.gov |
| EMAIL DESCRIPTION |
| Kimberly.LeMieux@va.gov |
*= Required Field
DESCRIPTION
1.0 DESCRIPTION
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs’ (VA) Enterprise Procurement Office (EPO) is issuing this Sources Sought Notice in accordance with FAR 10.002(b)(2) as a means of conducting market research to identify qualified sources with the capability and resources to meet the Veterans Health Administration’s (VHA) Non-Expendable Equipment National Program requirement for Eye Lane.
The EPO in conjunction with VHA is seeking a qualified source to supply brand name, brand-name-or-equal, or sole-source specification for Eye Lane and associated equipment on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the required products to VA medical centers and facilities throughout the United States.
The period of performance is for a base of 12-months with four 12-month option periods.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 and the associated size standard is 1,000 Employees.
The FAR Provision found at 52.204-7(b)(1) requires that an offeror be registered in SAM when submitting an offer or quotation and at time of award. All respondents should have the appropriate NAICS code reflected in SAM. SDVOSB/VOSB respondents should maintain current certification in the SBA Veteran Small Business Certification program, as applicable.
Submissions for this “sources sought” shall be submitted by email no later than September 18, 2026, at 9:00am ET to: Kimberly.LeMieux@va.gov.
This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.
2.0 SCOPE OF WORK
Eye Lane are multiple pieces of equipment/instruments needed to create complete eye examination lanes for expansion of eye care offered to Veterans, providing comprehensive eye exams to determine the health of the Veterans’ eyes. The following information regarding the needed equipment/instruments was modeled after multiple name brands. The equipment/instruments provided should be comparable to these name brands.
The following Contract Line Items (CLINs) are being considered:
| Contract Line Items |
| Manufacturer |
| Part Number |
| Description |
| 0001 |
| Volk |
| V20LC |
| Volk 20D Large Aspheric Lens with Black Ring |
| 0002 |
| Volk |
| V78C |
| Volk 78D Small Aspheric Lens with Black Ring |
| 0003 |
| Volk |
| V60C |
| Volk 60D Small Aspheric Lens |
| 0004 |
| Volk |
| V90C |
| Volk 90D Small Aspheric Lens with Black Ring |
| 0005 |
| Good-Lite Company |
| 730029 |
| Ishihara 14 Plate Color Test Book |
| 0006 |
| Gulden |
| 12121 |
| Maddox Rod and Red lens occluder |
| 0007 |
| Stereo Optical |
| SO-002 |
| Stereo Randot Test (Standard) |
| 0008 |
| Marco-Lombart |
| TF0MA7060 |
| Marco Metal Trial Lens Frame |
| 0009 |
| Marco-Lombart |
| TL0MA8408 |
| Lombart full diameter trial lens set with minus cylinders in case |
| 0010 |
| Welch Allyn |
| 18245 |
| Welch Allyn Elite Streak Retinoscope |
| 0011 |
| Welch Allyn |
| 41100 |
| Welch Allyn 3.5v halogen finnoff transilluminator |
| 0012 |
| Welch Allyn |
| 11720 |
| Welch Allyn 3.5V Coaxial Ophthalmoscope Head |
| 0013 |
| Welch Allyn |
| 71670 |
| Welch Allyn 3.5v NiCad Well Handle |
| 0014 |
| Gulden |
| 11116 |
| Gulden Horizontal Prism Bar |
| 0015 |
| Gulden |
| 11117 |
| Gulden Vertical Prism Bar |
| 0016 |
| Keeler |
| 2215P1034 |
| Amsler grid book |
| 0017 |
| Graham-Field Health Products |
| 1242 |
| Jaegar Reading Card |
| 0018 |
| Good-Lite Company |
| 700010 |
| Lorgnette Pinhole Occluder |
| 0019 |
| Marco-Lombart |
| MIRL |
| Front Surface Mirror Set |
| 0020 |
| Volk |
| VBIRID |
| Iridotomy Lens |
| 0021 |
| Volk |
| VCAPS |
| Capsulotomy Laser Lens |
| 0022 |
| Volk |
| VMSLT |
| Rapid SLT Lens |
| 0023 |
| Volk |
| VSQUAD160 |
| Super QuadR 160 PRP Laser Lens, with Flange |
| 0024 |
| Volk |
| VSQUAD160NF |
| Super QuadR 160 PRP Laser Lens, No Flange |
| 0025 |
| Volk |
| VHRWF |
| HR Wide Field PRP Laser Lens, with Flange |
| 0026 |
| Volk |
| VAC |
| Area CentralisR Lens, with Flange |
| 0027 |
| Volk |
| VACNF |
| Area CentralisR Lens, No flange |
| 0028 |
| Volk |
| VG3 |
| G-3 Gonio Lens |
| 0029 |
| Volk |
| VG4LNF |
| G-4 Mirror Gonio Lens |
| 0030 |
| Volk |
| VG4HAN2 |
| G-4 Mirror Gonio Lens, No Flange, 2-in-1 Handle |
| 0031 |
| Good-Lite Company |
| 621100 |
| Feinbloom Chart Low Vision Reading Chart |
| 0032 |
| Reichert |
| 230650 |
| Reichert AVIA Tonopen |
| 0033 |
| Marco-Lombart |
| EX0MAEX |
| Marco Prism Exophthalmometer |
| 0034 |
| Visionix |
| 8226-0015-02 |
| Retinomax K+Screen handheld autorefractor/keratometer |
| 0035 |
| Volk |
| VPRC |
| Volk Pan Retinal 2.2 Lens with Black Ring |
| 0036 |
| Luneau Technology |
| 12.20.84` |
| Luneau Retinoscopy Rack |
| 0037 |
| Marco-Lombart |
| BAT-2000 (update) |
| Marco Brightness Acuity Tester With Handle |
| 0038 |
| Stereo Optical |
| SO015 |
| Randot Stereo Test (Distance) |
| 0039 |
| Gulden |
| 15115 |
| C Daylight Glasses |
| 0040 |
| Gulden |
| 11L22 |
| S-22 Loose Prism Set |
| 0041 |
| Volk |
| VSFNC |
| Volk Superfield NC Lens |
| 0042 |
| Volk |
| VDGTLWF |
| Digital Widefield 90D Lens |
| 0043 |
| Volk |
| VDGTLCF |
| Digital clear Field 20D Lens |
| 0044 |
| Volk |
| VDGTLCM |
| Digital Clear Mag Lens |
| 0045 |
| Stereo Optical |
| SO-001 |
| Stereo Fly Test |
| 0046 |
| Good-Lite Company |
| 484025 |
| Hand-held +/- .25 Jackson – Cross Cylinder |
| 0047 |
| Good-Lite Company |
| 484050 |
| Hand-held +/- .50 Jackson – Cross Cylinder |
| 0048 |
| Gulden |
| 12136 |
| Maddox Phoria Measure |
| 0049 |
| Good-Lite Company |
| 494300 |
| Red/Green Reversing Flipper |
| 0050 |
| Good-Lite Company |
| 151170 |
| Neutral Density Filter Bar |
The Department of Veterans Affairs (VA) is seeking vendors who can provide the Name Brand Eye Lane equipment/instruments as listed or equal commodities that meet the salient characteristics below. Vendors may provide any product solution or configuration that meets the requirement. For each offered product, the response should include descriptive literature demonstrating how the product meets or exceeds each salient characteristic.
The following salient characteristics apply to the products identified below unless otherwise noted in the Product Description:
| SC # |
| SALIENT CHARACTERISTICS |
| Apply to CLIN # |
| METHOD OF EVALUATION |
| 1 |
| Field of View: must be at least 46 degrees static / 60 degrees dynamic |
| 0001 |
| Literature Review |
| 2 |
| Image magnification must be at least 3X |
| 0001 |
| Literature Review |
| 3 |
| Must be non-contact design. |
| 0001 |
| Literature Review |
| 4 |
| Field of View: must be at least 81 degrees static / 97 degrees dynamic |
| 0002 |
| Literature Review |
| 5 |
| Image magnification must be at least 0.9X |
| 0002 |
| Literature Review |
| 6 |
| Laser Spot Magnification factor must be at least 1.08X |
| 0002 |
| Literature Review |
| 7 |
| Field of view: must be at least 68 degrees static/81 degrees dynamic |
| 0003 |
| Literature Review |
| 8 |
| Laser spot magnification must be at least 0.086x |
| 0003 |
| Literature Review |
| 9 |
| Image Magnification must be at least 1.1x |
| 0003 |
| Literature Review |
| 10 |
| Field of View: must be at least 74 degrees static / 89 degrees dynamic |
| 0004 |
| Literature Review |
| 11 |
| Image magnification must be at least 0.76X |
| 0004 |
| Literature Review |
| 12 |
| Laser Spot Magnification factor must be at least 1.32X |
| 0004 |
| Literature Review |
| 13 |
| Must consist of 14 pseudoisochromatic color plates arranged in a bound album/book format |
| 0005 |
| Literature Review |
| 14 |
| Must screen for red-green color vision deficiencies |
| 0005 |
| Literature Review |
| 15 |
| Must have standardized color reproduction |
| 0005 |
| Literature Review |
| 16 |
| Must include special diagnostic plates for determining the type and severity of color vision defect |
| 0005 |
| Literature Review |
| 17 |
| Must include administration and scoring instructions. |
| 0005 |
| Literature Review |
| 18 |
| Must be handheld instrument consisting of a full-eye occluder on one end and optical-quality red lens on the other end in a double-ended configuration |
| 0006 |
| Literature Review |
| 19 |
| Overall length shall be at least 24cm |
| 0006 |
| Literature Review |
| 20 |
| Reusable design must be smooth surface easily cleanable using routine clinical disinfecting procedures. |
| 0006 |
| Literature Review |
| 21 |
| Must measure stereopsis/depth perception. |
| 0007 |
| Literature Review |
| 22 |
| Must have stereoacuity range </= 40 to >/= 400 arc sec |
| 0007 |
| Literature Review |
| 23 |
| Must use standardized scoring methodology. |
| 0007 |
| Literature Review |
| 24 |
| Must have PD adjustment range of 48-80mm minimum. |
| 0008 |
| Literature Review |
| 25 |
| Must be adjustable fit |
| 0008 |
| Literature Review |
| 26 |
| Must hold multiple lenses. |
| 0008 |
| Literature Review |
| 27 |
| Must be compatible with CLIN 0008 trial lens set |
| 0008 |
| Literature Review |
| 28 |
| Must have sphere range >/= +/-20D |
| 0009 |
| Literature Review |
| 29 |
| Must have cylinder range >/= +/-6D |
| 0009 |
| Literature Review |
| 30 |
| Increments must be </= 0.25D |
| 0009 |
| Literature Review |
| 31 |
| Must have streak illumination |
| 0010 |
| Literature Review |
| 32 |
| Must have adjustable focus sleeve |
| 0010 |
| Literature Review |
| 33 |
| Must have fiber optic light transmission |
| 0011 |
| Literature Review |
| 34 |
| Must have focused illumination |
| 0011 |
| Literature Review |
| 35 |
| Must be handheld |
| 0011 |
| Literature Review |
| 36 |
| Must be handheld |
| 0012 |
| Literature Review |
| 37 |
| Must have aperture/filter combinations |
| 0012 |
| Literature Review |
| 38 |
| Must be compatible with CLIN 0009, 0010 and 0011 |
| 0013 |
| Literature Review |
| 39 |
| Must be rechargeable 3.5v |
| 0013 |
| Literature Review |
| 40 |
| Must have calibrated prism powers |
| 0014 |
| Literature Review |
| 41 |
| Must have calibrated prism powers |
| 0015 |
| Literature Review |
| 42 |
| Must contain 7 Amsler Grids |
| 0016 |
| Literature Review |
| 43 |
| Must contain a score sheet |
| 0016 |
| Literature Review |
| 44 |
| Must provide multiple standardized print sizes for testing near vision |
| 0017 |
| Literature Review |
| 45 |
| Must use testing distance of 14-16 inches |
| 0017 |
| Literature Review |
| 46 |
| Must consist of 17 pin holes |
| 0018 |
| Literature Review |
| 47 |
| Pinhole attachment must be movable to provide a clear opening. |
| 0018 |
| Literature Review |
| 48 |
| Must be designed for ophthalmic examination use with front-surface optical coating |
| 0019 |
| Literature Review |
| 49 |
| Must provide iris visualization |
| 0020 |
| Literature Review |
| 50 |
| Must be compatible with Nd:YAG laser |
| 0020 |
| Literature Review |
| 51 |
| Must be compatible with Nd:YAG laser |
| 0021 |
| Literature Review |
| 52 |
| Must be designed for posterior capsulotomy procedures |
| 0021 |
| Literature Review |
| 53 |
| Compatible with standard ophthalmic laser systems requiring a contact SLT lens |
| 0022 |
| Literature Review |
| 54 |
| Must have optical design that minimizes reflections and supports accurate laser aiming |
| 0022 |
| Literature Review |
| 55 |
| Must provide approximately 160-degree retinal field of view for panretinal photocoagulation. |
| 0023 |
| Literature Review |
| 56 |
| Must have flanged contact surface |
| 0023 |
| Literature Review |
| 57 |
| Must be compatible with slit lamp-mounted retinal laser systems |
| 0023 |
| Literature Review |
| 58 |
| Must provide approximately 160-degree retinal field of view for panretinal photocoagulation procedures |
| 0024 |
| Literature Review |
| 59 |
| Must have no-flange design |
| 0024 |
| Literature Review |
| 60 |
| Must be compatible with standard slit lamp-mounted retinal laser systems. |
| 0024 |
| Literature Review |
| 61 |
| Must provide high-resolution wide retinal field of view for panretinal photocoagulation treatment. |
| 0025 |
| Literature Review |
| 62 |
| Must be compatible with slit-lamp-mounted retinal photocoagulation lasers. |
| 0025 |
| Literature Review |
| 63 |
| Optical design must provide uniform image quality from posterior pole through peripheral retina. |
| 0025 |
| Literature Review |
| 64 |
| Must have flanged contact surface to improve lens stability during treatment |
| 0026 |
| Literature Review |
| 65 |
| Must be high-magnification contact lens designed for focal retinal laser treatment of the macula and posterior pole |
| 0026 |
| Literature Review |
| 66 |
| Must provide high-resolution optical glass for minimal distortion and excellent visualization of fine retinal structures |
| 0026 |
| Literature Review |
| 67 |
| Must be compatible with standard slit lamp-mounted retinal laser system |
| 0026 |
| Literature Review |
| 68 |
| Must be high-magnification contact lens designed for focal retinal laser treatment of the macula and posterior pole |
| 0027 |
| Literature Review |
| 69 |
| Must have no-flange design to facilitate positioning while maintaining optical performance |
| 0027 |
| Literature Review |
| 70 |
| Multi-coated optical glass must provide high light transmission and reduce reflections |
| 0027 |
| Literature Review |
| 71 |
| Must be compatible with standard slit lamp-mounted retinal laser systems. |
| 0027 |
| Literature Review |
| 72 |
| Must have three mirror surfaces |
| 0028 |
| Literature Review |
| 73 |
| Must provide angle visualization |
| 0028 |
| Literature Review |
| 74 |
| Must have four mirror surfaces |
| 0029 |
| Literature Review |
| 75 |
| Must provide 360 degree angle visualization |
| 0029 |
| Literature Review |
| 76 |
| Must enable 360-degree visualization of the anterior chamber angle. |
| 0030 |
| Literature Review |
| 77 |
| Optical design must be suitable for diagnostic gonioscopy and anterior chamber angle laser treatment |
| 0030 |
| Literature Review |
| 78 |
| Must have integrated ergonomic handle for stable examination and laser procedures. |
| 0030 |
| Literature Review |
| 79 |
| Designed for assessment of low-vision near acuity |
| 0031 |
| Literature Review |
| 80 |
| Must have near acuity range to at least 20/800 equivalent |
| 0031 |
| Literature Review |
| 81 |
| Must be handheld and portable. |
| 0032 |
| Literature Review |
| 82 |
| Must have digital display |
| 0032 |
| Literature Review |
| 83 |
| Must have measurement range at least 5-55 mmHg |
| 0032 |
| Literature Review |
| 84 |
| Prisms must have easy-to-read mm lines on both sides. |
| 0033 |
| Literature Review |
| 85 |
| Must be designed for measurement of globe protrusion/orbital assessment. |
| 0033 |
| Literature Review |
| 86 |
| Must have spherical measurement range of at least -18D to +22D |
| 0034 |
| Literature Review |
| 87 |
| Must have Cylinder measurement range of at least 0 to +/-12D |
| 0034 |
| Literature Review |
| 88 |
| Must be handheld and portable |
| 0034 |
| Literature Review |
| 89 |
| Must have at least 72 degree field of view |
| 0035 |
| Literature Review |
| 90 |
| Must have minimum image magnification of 2.65x |
| 0035 |
| Literature Review |
| 91 |
| Must accommodate complete retinoscopy lens set |
| 0036 |
| Literature Review |
| 92 |
| Must have a minimum of three variable light sensitivity settings |
| 0037 |
| Literature Review |
| 93 |
| Must create repeatable glare conditions |
| 0037 |
| Literature Review |
| 94 |
| Testing distance must be 3m or 10 feet |
| 0038 |
| Literature Review |
| 95 |
| Stereoacuity must be </= 60 to >/= 400 arc sec |
| 0038 |
| Literature Review |
| 96 |
| Must simulate daylight conditions for color vision testing |
| 0039 |
| Literature Review |
| 97 |
| Must contain 22 prism lenses |
| 0040 |
| Literature Review |
| 98 |
| Prism lenses must range from </= 1 to >/= 40 diopters |
| 0040 |
| Literature Review |
| 99 |
| Must provide non-contact retinal examination for posterior segment evaluation |
| 0041 |
| Literature Review |
| 100 |
| Field of View must be >/= 95 degrees |
| 0041 |
| Literature Review |
| 101 |
| Must provide wide field of view suitable for examination of the posterior pole and mid-peripheral retina through a dilated pupil |
| 0042 |
| Literature Review |
| 102 |
| Must be compatible with standard slit lamps for non-contact retinal examination |
| 0042 |
| Literature Review |
| 103 |
| Must be high-resolution optical glass with anti-reflective coatings to minimize glare and maximize image clarity. |
| 0042 |
| Literature Review |
| 104 |
| Must provide a wide retinal field of view for binocular indirect ophthalmoscopy or equivalent examination techniques. |
| 0043 |
| Literature Review |
| 105 |
| Construction must be durable optical glass suitable for repeated clinical cleaning and disinfection. |
| 0043 |
| Literature Review |
| 106 |
| Must be compatible with standard ophthalmic slit lamps |
| 0044 |
| Literature Review |
| 107 |
| Construction must be multi-coated optical glass providing high contrast and reduced reflections. |
| 0044 |
| Literature Review |
| 108 |
| Must provide measurable stereoacuity levels |
| 0045 |
| Literature Review |
| 109 |
| Must evaluate gross stereopsis and fine depth perception. |
| 0045 |
| Literature Review |
| 110 |
| Must be cross-cylinder power +/- 0.25D |
| 0046 |
| Literature Review |
| 111 |
| Must be handheld |
| 0046 |
| Literature Review |
| 112 |
| Must be cross-cylinder power +/- 0.50D |
| 0047 |
| Literature Review |
| 113 |
| Must be handheld |
| 0047 |
| Literature Review |
| 114 |
| Must permit measurement of horizontal and vertical phoria/anisophoria |
| 0048 |
| Literature Review |
| 115 |
| Must provide a prism measurement range of at lease 0-10 PD with a readable indication of effective prism power |
| 0048 |
| Literature Review |
| 116 |
| Must incorporate a red Maddox lens/rod assembly with an approximately 25mm aperture |
| 0048 |
| Literature Review |
| 117 |
| Must incorporate red and green optical filters in a reversing/flipper configuration that permits the red and green filters to be alternated between the right and left eyes |
| 0049 |
| Literature Review |
| 118 |
| Must provide sufficient red-green dissociation for clinical assessment of the binocular vision, suppression, or related visual function |
| 0049 |
| Literature Review |
| 119 |
| Must be handheld, reusable, and constructed of durable, cleanable materials suitable for repeated use. |
| 0049 |
| Literature Review |
| 120 |
| Must provide multiple neutral-density attenuation levels suitable for controlled reduction of transmitted illumination, with each density level permanently identified on the filter bar |
| 0050 |
| Literature Review |
| 121 |
| Filters must attenuate visible light uniformly across the intended operating wavelength range without materialy altering the color or spectral characteristics of the transmitted light |
| 0050 |
| Literature Review |
| 122 |
| Filter elements must be optical-grade material |
| 0050 |
| Literature Review |
Responses to this Sources Sought Notice shall include the following:
1. Does vendor offer an annual service plan, Yes or No?
a. If Yes:
i. What does the plan cover?
ii. Does the plan cover software updates only?
iii. Does the plan cover parts repair or replacement only?
iv. Does the plan cover both software and parts?
b. Vendor is requested to provide documentation that shows information on their service plan.
c. Is the service provided by the OEM or a subcontractor?
2. Full name and address of company
3. UEI / CAGE Code / SAM registration information
4. Business Size
5. Manufacturer or Distributor
a. If distributor, provide full name, business size, and address of manufacturer.
6. Country of Origin designation for all products
7. Ability to provide uninterrupted supply of products on a national scale
8. Technical literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met
9. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
10. Authorized Distributor Letter certified by OEM with a current date.
Although not required, vendors responding to this Sources Sought are highly encouraged to submit a Capabilities Statement.