DIX_Mech_HVAC_2.pdf
PDF 19 MB Posted
- Attached to
- NOLA SATOC Federal contract opportunity
- Solicitation number
- VA10117R0396
About this file
DIX Mech HVAC 2
View the file
Other files for this federal contract opportunity
Show all 50
NOLA SATOC has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
B8�LEVEL 01
100' � 0"
B8�LEVEL 02
115' � 3 1/8"
B8�LEVEL 03
132' � 1 1/8"
B8�LEVEL 04
148' � 7 1/8"
B8�LEVEL 05
166' � 1 1/8"
B8�LEVEL 02.5
128' � 1 1/8"
B8�LEVEL 3.5
140' � 0"
08 108 208 308 7 08 4
2.5
3.6
1.5
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
8MH301
BLDG 08 HVAC FLOOR SECTIONS
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
1/4" = 1'�0"
HVAC FLOOR SECTION
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH�0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH�5 SERIES OF
DRAWINGS.
3. FOR CONTROL DIAGRAMS SEE THE MH�8 SERIES OF
DRAWINGS.
B8�LEVEL 05
166' � 1 1/8"
AHU�1
08�5P
AHU�2
08�5P
AHU�5
08�5P
AHU�3
08�5P
EF�16b
08�5P
EF�16a
08�5P
RF�5
08�5P x3
EF�12a
08�5P
EF�12b
08�5P
FT�3
06�3M2
FT�4
08�5P
8MH303
08 F08 G08 H08 J
J.3
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
8MH302
BLDG 08 HVAC PENTHOUSE MECHANICAL
ROOM SECTIONS
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
1/4" = 1'�0"
NORTH PENTHOUSE SECTION
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH�0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH�5 SERIES OF
DRAWINGS.
B8�LEVEL 05
166' � 1 1/8"
B8�ROOF HIGH
204' � 8"
AHU�3
08�5P
EF�3
08�5P
36x96
36x72
96x36
08 108 208 308 4
2.5
3.6
1.5
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
8MH303
BLDG 08 HVAC PENTHOUSE MECHANICAL
ROOM SECTIONS
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
1/4" = 1'�0"
WEST PENTHOUSE SECTION
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH�0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH�5 SERIES OF
DRAWINGS.
EMEREMEREMEREMER
ELECELECELECELEC
5P1015P1015P1015P101
ELECELECELECELEC
SWSWSWSW
GEARGEARGEARGEAR
5P1005P1005P1005P100
VEST
5P100A
VEST
5P200
ELEV
PS�01
EF�9
08�5P
EF�10
08�5P
EF�7
08�5P
EF�6
08�5P
EF�5
08�5P
EF�18
08�5P
6"HPS UP&DN
12" ACID STORAGE UP&DN
12" FLAMMABLE SOLV.
EXH. UP&DN
12" GAS STORAGE UP&DN
12" BIO HAZARD
WASTE EXH UP&DN
12" RADIO
WASTE EXH. UP&DN
M
H
M
H
EF�14
08�5P
10"CHS&CHR UP&DN
36x36 OPEN�END
DUCT WITH 1/2"
WIRE MESH SCREEN.
3,000 CFM.
36x36 OPEN�END
DUCT WITH 1/2"
WIRE MESH SCREEN.
3,000 CFM.
32x16 SUPPLY
UP.
x1 x1
SD�62
SD�62
SD�62
SD�62
SD�62
SD�62
SD�62
SD�62
16x16 16x16
SD�62
SD�62
SD�62
SD�62
SD�62
SD�62
SD�62
SD�62
32x16 SUPPLY
UP.
36x36 OPEN�END
DUCT WITH 1/2"
WIRE MESH SCREEN.
3,000 CFM.
SD�62
SD�62
SD�62
16x16 16x16
SD�62
SD�62
SD�62
32x16 SUPPLY
UP.
FOR CONTINOUS
FOR 12"CHS&CHR; 3"HWS&HWR
REFER TO DRAWING
8MH105.5
3" HWS
3" HWS&HWR UP&DN
3"PC UP&DN
FOR CONTINOUS
6"HPS; 3"PC
REFER TO DRAWING
8MH105.5
08 A
08 1
08 2
08 3
08 4
B.6
2.5
3.6
08 C
B
1.5
6" HPS
3" PC
FCU�10
08�5P
FCU�11
08�5P
FCU�12
08�5P
1 1
3" HWR
CO CO
CO
1" CHR
1" CHS
3/4" HWS
3/4" HWR
1 1/2" CHR
1 1/2" CHS
1" HWS
1" HWR
2" CHR
2" CHS
1" HWS
1" HWR
1" CHS/R
3/4" HWS/R
1" CHS/R
3/4" HWS/R
1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
FLOOR DRAIN
1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
FLOOR DRAIN
1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
FLOOR DRAIN
FOR CONTINOUS
FOR 2"CHS&CHR; 1"HWS&HWR
REFER TO DRAWING
8MH402
Q
D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
8MH401
BLDG 08 HVAC EAST PENTHOUSE ENLARGED
PLAN - AREA P
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED 1/4" = 1'�0"
East Mechanical ENLARGED PLAN
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH�0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH�5 SERIES OF
DRAWINGS.
3. FOR CONTROL DIAGRAMS SEE THE MH�8 SERIES OF
1 Addendum 1 9/21/12
MECHMECHMECHMECH
PENTPENTPENTPENT
5P1025P1025P1025P102
EF-9
08-5P
EF-10
08-5P
EF-7
08-5P
EF-6
08-5P
EF-5
08-5P
EF-18
08-5P
AHU-6
08-5P
RF-6
08-5P
SAD-21
08-5P x6
62x42 x4 x1
72x36 x3
96x36
PRV-1
08-5P
ET-1
08-5P
HWP-1
08-5P
HEX-1
08-5P
HEX-2
08-5P
FTK-1
08-5P
CP-1
08-5P
HEX-3
08-5P
HEX-4
08-5P
AHU-4
08-5P
EF-4
08-5P
EF-1
08-5P
EF-2
08-5P
(BELOW)
(ABOVE)
ACD-TP
POT FEEDER
SDPR
ACD
SD
SD
SD
SD
(VERTICAL)
HOT WATER TANKS
SDPR-6
08-5P
AFMD-14
08-5P
AFMD-13
08-5P x4 x4
SAD-8
08-5P
EF-12b 08-5P ø ø
FT-4
08-5P
FT-4
08-5P
EF-11a 08-5P
EF-11b 08-5P
EF-8
08-5P
EF-17
08-5P
EF-13
08-5P
18ø ø
12ø
16ø
16ø
12ø ø ø ø
48ø48ø
46ø
SAD-19
08-5P
72x3636x24
HWP-3
08-5P
10ø
10ø
10ø
10ø
10ø
10ø x3
42x60
12" HAZ.
WASTE EXH. DN
16"CAGE WASHER DN
M
H
M
H
M
H
M
H
8MH302
INTAKE PLENUM
9'-10"(W)x5'-0"(D)x25'-0"(H)
INTAKE PLENUM
15'-6"(W)x5'-0"(D)x25'-0"(H)
OUTSIDE AIR
LOUVER
140 S.F. OF FREE
AREA
12" EXH. UP
12" EXH. UP
12" EXH. UP
12" EXH. UP
12" EXH. UP
OUTSIDE AIR
LOUVER
80 S.F. OF FREE
AREA
SDPR-4
08-5P
EF-19
08-5P x3 x3
16ø
12ø
12ø
12ø
16ø ø ø ø ø ø
SAD-30
08-5P ø ø
12"DIA. CAP AND SEAL EXHAUST
DUCT RISER.
ADD-ALTERNATE
ADD-ALTERNATE
x1
ADD-ALTERNATE
ADD-ALTERNATE
9.37
12"DIA. CAP AND SEAL EXHAUST
DUCT RISER.
10" CHS
10" CHR
x1 x1
SD-62
SD-62
SD-62
SD-62
SD-62
SD-62
SD-62
SD-62
32x16
UP
SD-62
SD-62
16x16
FOR CONTINUOUS OF
12" CHS&CHR; 3"HWS&HWR
REFER TO DRAWING
8MH105.5
10" CHS
10" CHR
6"CHS&CHR
TO AHU-4
COOLING COIL.
4"CHS&CHR
TO AHU-6
COOLING COIL.
36x18
OPEN-ENDED
DUCT WITH
1/2" WIRE MESH
SCREEN.
1"LPR TO
CP-1
4" LPS
3" LPS
4" LPS
3" HWS
4" HWR
4" HWS
3" HWS
3" HWR
4" HWR
4" HWS
6" H
W R
4" HWR
4" HWS
3"HWS&WHR
TO AHU-4
PREHEATING COIL.
2"HWS&HWR
TO AHU-6
PREHEATING COIL.
6" H
W R
6" H
W S
3" GRR
3" GRS
3" G
R S
3" G
R R 3"
G R
S
3" G
R R
3" GRS
3" GRR
FOR CONTINUOUS OF
6"HPS; 3"PC
REFER TO DRAWING
8MH105.5
6" HPS
6" H
P S
10" CHS
10" CHR
SV-10
08-5PEV-18
08-5P
SV-11
08-5P
EV-19
08-5P
SV-12
08-5P
EV-20
08-5P
EV-21
08-5P
SV-13
08-5P
EV-22
08-5P
SV-14
08-5P
SV-15
08-5P
EV-23
08-5P
SV-16
08-5P
EV-24
08-5P
SV-17
08-5P
EV-26
08-5P
PRV-2
08-5P
8" VENT
4" MPS
08 D08 F
08 1
08 2
08 3
08 4
3.6
08 E
1.5
6" MPS
HWP-2
08-5P
6" HWS
8" MPS
AS-1
08-5P
6" H
W S
6" H
W R
6" HWS
6" HWS
6" HWR
6" H
W R
2 1/2" MPS
3" GRS
3" GRS
3" GRR
AS-2
08-5P
ET-2
08-5P
2 1/2" MPS
6" MPS
6" MPS
POT FEEDER
1" GRS
80x44
3" MPS
3" M
P S
3" M
P S
3"MPS DN
TO LEVEL 4
SOIL CAGE
WASH.
2" MPS
1 1/4" MPS
2 1/2" MPS
(TYPICAL)
2 1/2" MPS
2 1/2" MPS
6" MPS
2 1/2" MPS
8" VEN
T
8" V
E N
T
4" VENT
8" V
E N
T
6" VENT
8"VENTS UP
TO ROOF
LEVEL.
4" MPR
2" MPR
3" MPR 3" MPR2" MPR
1 1/2" MPR
1 1/2" MPR
3" PC3" PC
3" PC
4" MPR
FCU-3
08-5P
FCU-4
08-5P
FCU-6
08-5P
FCU-7
08-5P
FCU-8
08-5P
FCU-9
08-5P
VFD-15
08-5P
VFD-16
08-5P
VFD-8
08-5P
VFD-9
08-5P
VFD-10
08-5P
VFD-11
08-5P
VFD-4
08-5P
VFD-6
08-5P
VFD-13
08-5P
VFD-19
08-5P
VFD-20
08-5P
ATC
SAD-33
08-5P
12ø12ø
SAD-15
08-5P
SAD-17
08-05P
SDPR-9
08-5P
SAD-23
08-5P
SAD-22
08-5P
SAD-24
08-5P
SAD-25
08-5P
SAD-26
08-5P
3"COIL CONDENATE
TO FLOOR DRAIN.
3"COIL CONDENATE
TO FLOOR DRAIN.
EAHU-1
08-5P
(ABOVE)
EAHU-2
08-5P
(BELOW)
EAHU-4
08-5P
2"COIL CONDENATE
FROM EAHU-1 AND
EAHU-2 TO FLOOR
DRAIN.
2"LPR DN.
EV-25
08-5P
6" H
W S
CO
CO
CO 1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
FLOOR DRAIN
1" HWS
1" HWR
3/ 4"
H W
S
3/ 4"
H W
R
1" C
H R
1" C
H S
1/
2" C
H R
1/
2" C
H S
1" CHS/R
3/4" HWS/R
CO
1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
FLOOR DRAIN
6" H
W R
1/
2" H
W R
1/
2" H
W S
1" H
W R
1" H
W S
3/4" HWR
3/4" HWS
1" CHS
1" CHR
CO
CO
CO 1 1/4" DRAIN PIPE TO
BE ROUTED TO
NEAREST FLOOR
DRAIN
3" HWR
3/ 4"
H W
R
3/ 4"
H W
S
1" C
H S
1" C
H R
1" CW TO BACK FLOW
PREVENTER BY PLUMBING
1" CW
1" C
W
1" CW DN
2" CHR
2" CHS
1" HWS
1" HWR
2" C
H R
2" C
H S
1/
4" H
W S
1/
4" H
W R
1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
MOP SINK FLOOR DRAIN
CO
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
8MH402
BLDG 08 HVAC EAST PENTHOUSE ENLARGED
PLAN - AREA P
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED 1/4" = 1'-0"
Mechanical ENLARGED PLAN
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH-0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH-5 SERIES OF
DRAWINGS.
3. FOR CONTROL DIAGRAMS SEE THE MH-8 SERIES OF
DRAWINGS.
1 Addendum 1 9/21/12
8 BULLETIN #46 10/12/15
SEE RFI 04835 :
Shows duct routing for exhaust vents.
12x12x12 PLENUM
12x12 LOUVER
~10'-0" AFF
8" DRYER
EXHAUST DN
RFI 04945
MECHMECHMECHMECH
PENTPENTPENTPENT
5P1025P1025P1025P102
POT FEEDER
ACD
SD
SDPR
SD
ACD-TP
ACD-TP
EF-13
08-5P
EF-17
08-5P
EF-8
08-5P
EF-11a 08-5P
EF-11b 08-5P
EF-15a 08-5P
EF-15b 08-5P
FT-2
08-5P
FT-1
08-5P
48ø ø ø ø x4 x4 x4 x4
80x44 ø
18ø
SAD-7
08-5P SAD-8
08-5P
HWP-4
08-5P
HWP-3
08-5P
ET-2
08-5P
CSG-1
08-5P
CSG-2
08-5P
HEX-4
08-5P
HEX-3
08-5P x3 x3 x3
96x36
SAD-6
08-5P x6
42x60 x4
AHU-3
08-5P
AHU-5
08-5P
EF-3
08-5P
SAD-27
08-5P
EF-16a 08-5P EF-16b
08-5P
24x20 x1 x2
AHU-2
08-5P
24x20 x2 x2 ø ø
24ø x3 x2 x2
AHU-1
08-5P
(BELOW)
(ABOVE)
36x24
60x36
SAD-32
08-5P
(VERTICAL)
EF-12a 08-5P
EF-12b 08-5P
RF-5
08-5P ø ø ø
M
H
M
H
8MH302
8MH303
INTAKE PLENUM
17'-0"(W)x5'-0"(D)x25'-0"(H)
INTAKE PLENUM
9'-6(W)x5'-0"(D)x25'-0"(H)
INTAKE PLENUM
15'-6"(W)x5'-0"(D)x25'-0"(H)
OUTSIDE AIR LOUVER
140 S.F. OF FREE AREA
AFMD-10
08-5P
SDPR
SDPR-5
08-5P
SDPR-3
08-5P
OUTSIDE AIR LOUVER
120 S.F. OF FREE AREA
OUTSIDE AIR LOUVER
80 S.F. OF FREE AREA
SD
AFMD-11
08-5P
ACD-TP ACD-TP
6"CHS&CHR
TO AHU-2
COOLING COIL.
6"CHS&CHR
TO AHU-1
COOLING COIL.
4"CHS&CHR
TO AHU-5
COOLING COIL.
6"CHS&CHR
TO AHU-3
COOLING COIL.
4" CHR
4" CHS
10" CHS
10" CHR
36x18
36x18
OPEN-ENDED DUCT
WITH 1/2"
WIRE MESH
SCREEN.
FT-4
08-5P
4" L
P S
4" L
P S
4" L
P S
4" LPS 4" LPS
3" LPS
6" CHR
6" CHS
6" C
H S
6" C
H R
3" LPS
ADD-ALTERNATE 9.36
4" LPS
FT-3
06-3M2
18"DIA. DN
12ø
12"DIA
DN
3" HWS
3" HWR
10" CHS
10" CHR
4" HWS
4" HWR
2"HWS&HWR
TO AHU-5
PREHEATING COIL.
4" HWR
4" HWS
3"HWS&HWR
TO AHU-3
PREHEATING COIL.
3" HWR
3" HWS
3"GRR
3" C
H R
3" GRR
3" G
R S
3" G
R R
3" G
R S
3" G
R R
3" GRS
3" GRR
3" GRS
3" GRR
SV-1
08-5P
EV-1
08-5P
EV-2
08-5P
EV-3
08-5P
SV-2
08-5P
EV-4
08-5P
EV-5
08-5P
EV-6
08-5P
SV-3
08-5P
EV-7
08-5P
EV-8
08-5P
SV-4
08-5P
EV-9
08-5P
EV-10
08-5P
SV-5
08-5P
SV-6
08-5P
SV-7
08-5P
EV-11
08-5P
SV-8
08-5P
EV-12
08-5P
EV-13
08-5P
EV-15
08-5P
SV-9
08-5P
EV-16
08-5P
08 G08 H08 J
08 1
08 2
08 3
08 4
J.3
3.6
1.5
3" GRR
3" G
R R
3" GRS
3" GRS
AS-2
08-5P
2 1/2" MPS 2 1/2" MPS
3" GRS
3" GRS
3" G
R S
3" C
H S
1 1/4" MPS
FCU-1
08-5P
FCU-2
08-5P
FCU-3
08-5P
FCU-4
08-5P
VFD-1
08-5P
VFD-2
08-5P
VFD-3
08-5P
VFD-5
08-5P
VFD-15
08-5P
VFD-16
08-5P
VFD-8
08-5P
VFD-9
08-5P
VFD-10
08-5P
VFD-11
08-5P
VFD-12
08-5P
VDF-17
08-5P
VDF-18
08-5P
ATC
VFD-19
08-5P
VFD-20
08-5P
1"LPR
TO CP-1
SAD-4
08-5P
SAD-3
08-5P
SDPR
SDPR-1
08-5P
SDPR
SDPR-8
08-5P
EAHU-3
08-5P
(ABOVE)
(BELOW)
3"COIL CONDENSATE
TO FLOOR DRAIN.
3"COIL CONDENSATE
TO FLOOR DRAIN.
FROM AHU-1 AND AHU-2.
3"COIL CONDENSATE
TO FLOOR DRAIN.
2"LPR DN
2" LPR DN
EV-14
08-5P
EV-17
08-5P
3" C
H S
3" C
H R
1" C
H S
1" C
H R
3/ 4"
H W
S
3/ 4"
H W
R
1/
2" C
H S
1/
2" C
H R
1" HWS
1" HWR
3" H
W S
3" H
W R
2" HWR
2" HWS
1" HWR
1" HWS
1/
2" H
W R
1/
2" H
W S
1" H
W R
1" H
W S
3/4" HWS
3/4" HWR
3/4" HWS
3/4" HWR
1" CHS
1" CHR 1 1/2" CHR
1 1/2" CHS
1/
2" C
H R
1/
2" C
H S
3/4" HWS/R
3/4" HWS/R
3/4" HWS/R
1" CHS/R
1" CHS/R
3/4" HWS/R
CO
1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
FLOOR DRAIN
1 1/4" DRAIN PIPE TO
BE ROUTED TO NEAREST
FLOOR DRAIN
CO
CO
CO
CO
1 1/4" DRAIN PIPE TO BE
ROUTED TO NEAREST
FLOOR DRAIN
WATER-COOLED CONDENSING
UNITS, FOR WALK-IN CONSTANT
TEMPERATURE ROOMS 3P149A &
4P305, BY OTHERS.
REFRIGERANT LINES DOWN TO 3P149A &
4P305 BELOW. PIPING SIZED PER
MANUFACTURER'S RECOMMENDATIONS
TIE 1 1/2" CHS/CHR
INTO CHS/CHSR
PIPING AT CHASE
1 1/4"
CHS/R
1 1/2"
CHS/R
1"CHS/R
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
8MH403
BLDG 08 HVAC WEST PENTHOUSE ENLARGED
PLAN - AREA P
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
NEW ORLEANS, LOUISIANA
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED 1/4" = 1'-0"
West Mechanical ENLARGED PLAN
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH-0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH-5 SERIES OF
DRAWINGS.
3. FOR CONTROL DIAGRAMS SEE THE MH-8 SERIES OF
DRAWINGS.
1 Addendum 1 9/21/12
8 BULLETIN #46 10/12/15
SEE RFI 04835 :
Shows duct routing for exhaust vents.
8.5
K
L
AHU
5P
AFMD
5P x1 x1 6S
5P
20x22
8x12
10x20
S 5P
S 5P
20x14 x1 x1
S 5P x8
FD
FD
FD
FD
FD
12x8 SUPPLY
DUCT DN.
12x8 SUPPLY DUCT
DN.
20x14 SUPPLY DUCT
DN.
12x10 SUPPLY
DUCT DN
8"DIA SUPPLY DUCT
DN
4' 0"(W)x2' 6"(D)x3' 0"(H)
INTAKE PLENUM.
RF
5P
28x14 x1
2AD
18x12 OPEN
END
DUCT WITH
1/2" WIRE MESH
SCREEN.
AFMD
5P
SAD
5P
FD
(IN VERTICAL)
24x12 RETURN DN
12" RETURN DUCT
DN
FD
SAD
5P
SD
(IN VERTICAL)
BCD
24"x36"
RELIEF
WITH 1/2" WIRE
MESH SCREEN.
RELIEF LOUVER INTAKE LOUVER
x6
SAD
5P x6
28x14
1 1/2" HWR
1 1/2" HWS
2" CHS
2" CHR
1" HWR
1" HWS
1" HWR
1" HWS
2"CHS&CHR DN
1/2"HWS&HWR DN
FD
8"DIA SUPPLY DUCT
DN
08 D 08 A B.6
7.6
8.3
08 C B
FCU
5P
FCU
5P
FCU
5P
FCU
5P
VFD
5P
VFD
5P
A
TC
SD
SDPR
5P
CO
CO
CO
CO
1 1/4" DRAIN PIPE TO
BE ROUTED TO NEAREST
FLOOR DRAIN
1 1/4" DRAIN PIPE TO
BE ROUTED TO NEAREST
FLOOR DRAIN
1 1/4" DRAIN PIPE TO
BE ROUTED TO NEAREST
FLOOR DRAIN
1 1/4" DRAIN PIPE TO
BE ROUTED TO NEAREST
FLOOR DRAIN
1 1/4" CHR
1 1/4" CHS
3/4" HWS
3/4" HWR
3/ 4"
H W
R
3/ 4"
H W
S
1/
4" C
H S
1/
4" C
H R
3/ 4"
H W
R
3/ 4"
H W
S
1/
2" C
H S
1/
2" C
H R
1/
4" C
H S
1/
4" C
H R
1 1/4" CHS
1 1/4" CHR
3/ 4"
H W
R
3/ 4"
H W
S
1 1/4" CHS
1 1/4" CHR
1 1/2" D
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
8MH404
BLDG 08 HVAC DIXIE PENTHOUSE ENLARGED
PLAN-AREA P
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
1/4" = 1' 0"
B8 Level 05 DIXIE Ductwork & Piping
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH
0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH
5 SERIES OF
DRAWINGS.
3. FOR CONTROL DIAGRAMS SEE THE MH
8 SERIES OF
1 Addendum 1 9/21/12
8.5
K
L
CAFE
1P113ALT
CAFE
BAR
1P113C
WORKROOM
1P113B
EG-14
EG-14
SD-13
SD-13
SD-13
SD-13
SD-13
24x12
16x8 x8
16x8
16x8
FOR CONTINUATION
SEE DWG.# 8MH101-P
x8
16x8 16x8 x1
RG-14
RG-14
S-44 08-1P
16x8
SD-13
SD-13
24x12
08 A B.6
7.6
8.3
08 C B
16x816x8
Q D2 D1
E2 E1
F2 F1
G2 G1
A2
A4
A5
A1
A6
B1
C1 C2
B2
H
J1 J2
L
K
M1 M2 M3
N1 N2
A7
D3
E3
F3
R1
R4
R2 R3
A3
08 P
PLAN
NORTH
DATE
LOCATION
CHECKED DRAWN
PROJECT TITLE PROJECT NUMBER
DOCUMENT SET PACKAGE
DRAWING NUMBERAPPROVED: PROJECT DIRECTOR
DRAWING TITLEARCHITECT/ENGINEERS:CONSULTANTS:
REVISIONS: DATE
B
A
D
C
E
VA FORM 08-6231
O N
E
EI
G H
T
IN
C H
O
N E
FO
O
T O
N E
Q U
AR
TE
R
IN
C H
O
N E
FO
O
T O
N E
H A L
F
IN
C H
O
N E
FO
O
T
TH
R
EE
Q U
AR
TE
R S
IN
C
H
O N
E
FO
O T
TH
R
EE
IN
C H
ES
O N
E
FO
O T
O N
E
IN
C H
F
O R
TY
F
E E T
(1
0'
6"
6"
0'
0'
123456
F
B
A
D
C
E
F
O N
E
SI
X T
EE
N
TH
IN
C
H
O N
E
FO
O T
O N
E
AN
D O
N E
H
AL
F
IN
C H
ES
O N
E
FO
O T
6"
BUILDING NUMBER
NEW ORLEANS, LOUISIANA
8MH405
HVAC DIXIE CAFE ADD ALTERNATE DUCTWORK
AND PIPING
BE RPBJuly 16, 2012
8629-HS2-401SLVHCS REPLACEMENT MEDICAL
CENTER PROJECT
SCHRENK & PETERSON CONSULTING ENGINEERS / CIVIL
KORDA/NEMETH ENGINEERING / STRUCTURAL
BR+A CONSULTING ENGINEERS / MECH, ELECT, PLUMBING, LOW VOLTAGE
ARCHITECTURAL ENGINEERING / PLUMBING
SCALES ASSOCIATES / FIRE PROTECTION
BR+A CONSULTING ENGINEERS / LOW VOLTAGE
DESMAN ASSOCIATES / PARKING
CODE CONSULTANTS, INC. / CODE CONSULTANT
THE SEXTANT GROUP / AV & ACOUSTICAL
HAMMER DESIGN ASSOCIATES / FOOD SERVICE
PYBURN & ODOM / ABATEMENT
TATA & HOWARD / TANK CONSULTANT
Department of
Veterans Affairs
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
WP_09B
CONSTRUCTION DOCUMENTS 1
FULLY SPRINKLERED
1/4" = 1'-0"
B8-Level 01 - Dixie Cafe Ductwork and Piping Add Alternate
GENERAL NOTES:
1. FOR SYMBOL LIST ABBREVIATIONS, AND GENERAL
NOTES THAT APPLY TO ALL DRAWINGS SEE THE
MH-0 SERIES OF DRAWINGS.
2. FOR GENERAL DETAILS SEE THE MH-5 SERIES OF
DRAWINGS.
3. FOR CONTROL DIAGRAMS SEE THE MH-8 SERIES OF
RFI 7657 deleted exhaust hoods
RFI 7657 deleted exhaust hoods RFI 7657 deleted exhaust hoods
PB RFI WP-09B-064:
Refer to Architectural Drawings (8AS101) for Access Ladder requirements.
PB RFI WP-09B-064:
Refer to Architectural Drawings (8AS101) for Access Ladder requirements.
Pre-Bid RFI WP-09B-061:
Domestic Water and Fire Water Lines also enter service pit. Reference Plumbing and Fire Protection Drawings for Sizing and Location.
Pre-Bid RFI WP-09B-061:
Domestic Water and Fire Water Lines also enter service pit. Reference Plumbing and Fire Protection Drawings for Sizing and Location.
PreBid RFI WP09B062:
Clarification of Condensate Pump Purpose.
File details come from the government source that posted it. Updated .