This document is a comprehensive set of architectural installation drawings and technical specifications for ceiling-mounted patient lift systems manufactured by Guldmann Inc. at the VA San Diego facility (Building 1, 3350 La Jolla Village Drive, San Diego, CA 92161), Project ID 103067.
The installation drawings detail fixed rail systems for 103 patient rooms across multiple levels serving various clinical functions including hemodialysis stations, ICU beds, examination rooms, procedure rooms, women's clinic, and observation/bedroom areas. The systems utilize aluminum rail specifications (Rails A, B, and C with varying load capacities), suspension rod assemblies, seismic bracing, and transformer-based power delivery (DK-13991 transformer providing 33V AC output). Key technical requirements include facility structure capacity verification, electrical power provision by the facility, maximum weight limits (375 kg for single hoists, 500 kg for twin hoists with 564040 trolley), door header modifications, and systems tested at 1.5 times capacity. Installation requires signed customer approval prior to ordering, and the facility must coordinate with Guldmann Inc. regarding track layout modifications, conduit protection, and door frame modifications. The drawings span 69 pages with detailed schematics for typical hanger and brace requirements, expansion anchor specifications, ceiling bracket dimensions, and load ratings across 79 individual systems. Revisions were issued from January 2023 through January 2026, with the most recent revision (G) dated 01/26/2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| VA SD Bldg 11_103067_SET_G.pdf | ||
| 36C26226Q0927.docx | DOCX document | |
| SOW-Draft RFI 36C26226Q0927 Guldmann OR EQUAL Ceiling Patient Lifts.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
SIGNOFF / APPROVAL NOTES
1. The facility structure capacity must be able to support the load specified on the installation drawing.
2. Electrical power source provided by the facility, position to be verified in the field.
3. Guldmann Inc. reserves the right to slightly modify the track layout if necessary without Facility approval.
This includes lowering the system to avoid ceiling objects.
4. Guldmann Inc. will not be held responsible for any damages, inconvenience, resulting from hitting any non visible conduits during our installation process of which we have not been advised.
5. Modifications of door headers by the facility.
6. Signed drawings are required prior to ordering and installation of ceiling lifts.
This signature of each drawing confirms agreement of all the conditions listed above.
7. Systems are tested at 1.5 times capacity.
550 lbs. tested at 825 lbs.; 770 lbs. tested at 1155 lbs.; 825 lbs. tested at 1238 lbs.; 1100 lbs. tested at 1650 lbs.
MY SIGNATURE BELOW VERIFIES THAT I HAVE:
Reviewed all _____ pages, with a total quantity of _____ room(s), _____ system(s) for the approbation of layout for each room and the approbation of structure for each room.
CUSTOMER
APPROVAL: _____________________________________ DATE: _______________
DATE: DRAWN BY:
VA San Diego
VA SD BLDG 1
3350 La Jolla Village Dr.
San Diego, CA 92161
PROJECT ID:103067
VA SD BLDG 1
FACILITY SIGNOFF
GUL001
TRC01/15/2023
69 103 79
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
TYPE B / TYPE C / TYPE P
Revision Schedule
Date Issued by Letter Description
01/15/2023 TRC A UPDATED BACKGROUNDS AND ROOMS BACKGROUNDS REVISED
03/01/2023 TRC B REVISED PER UPDATED ROOM MATRIX AND BACKGROUNDS
03/08/2023 TRC C REVISED PER PRELIM COMMENTS
03/28/2023 KIT D UPDATED SEISMIC PER ENDINEER
10/30/2024 TRC E MULTIPLE ROOMS REMOVED PER NEW MATRIX
07/07/2025 YC F REVISED PER UPDATED ROOM MATRIX AND BACKGROUNDS
01/26/2026 YC G UPDATED ROOM LIST AND ATTACHMENT DETAIL
INTERSTITIAL STEEL, SPAN = 4' - 0''
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
SHEET INDEX
GUL002
YC07/07/2025
PROJECT ID:103067
Sheet List
Sheet Number Sheet Name Issue Date Current Revision Current Revision Date
GUL125 1123A Exam Triage 01/15/2023 F 07/07/2025
GUL126 1123B Exam Triage 07/07/2025 F 07/07/2025
GUL127 1128 Corridor 07/07/2025 G 01/26/2026
GUL128 1123H/1123I/1123J ED Triage 07/07/2025 F 07/07/2025
GUL129 1171 Procedure Room 01/15/2023 F 07/07/2025
GUL130 1456 Physical Therapy 01/15/2023 F 07/07/2025
GUL131 1481 Pool 01/15/2023 F 07/07/2025
GUL132 1812 Ultrasound 01/15/2023 F 07/07/2025
GUL300.1 Bldg 1/Lvl 3 - Hemodialysis 01/15/2023 G 01/26/2026
GUL300.2 Bldg 1/Lvl 3 - Women's Clinic 07/07/2025 F 07/07/2025
GUL301 3051A/3051B/3051C Dialysis Station 07/07/2025 F 07/07/2025
GUL302 3053A/3053B/3053C Dialysis Station 01/15/2023 F 07/07/2025
GUL303 3054/3054A Separation Hemodialysis 07/07/2025 F 07/07/2025
GUL304 3055A/3055B/3055C/3055D Dialysis Station 07/07/2025 F 07/07/2025
GUL305 3063A/3063B Separation Hemodialysis 01/15/2023 F 07/07/2025
GUL306 3064A Dialysis Station 07/07/2025 F 07/07/2025
GUL307 3065A-B-C-D-E-F-G Dialysis Station 07/07/2025 G 01/26/2026
GUL308 3088 Women's Clinic 07/07/2025 F 07/07/2025
GUL400 Bldg 1/Lvl 4 07/07/2025 G 01/26/2026
GUL401 4015 Simulation Education 01/15/2023 F 07/07/2025
GUL402 4310+4311 Nurse Practitioner 01/15/2023 F 07/07/2025
GUL403 4505 Scanner 2 01/15/2023 F 07/07/2025
GUL404 4506 Scanner 1 01/15/2023 F 07/07/2025
GUL500.1 Bldg 1/Lvl 5 Beds SICU 07/07/2025 F 07/07/2025
GUL500.2 Bldg 1/Lvl 5 Beds 23 HR Observation 07/07/2025 F 07/07/2025
GUL501 5107 ICU 01/15/2023 F 07/07/2025
GUL502 5117 ICU 01/15/2023 F 07/07/2025
GUL503 5118 ICU 01/15/2023 F 07/07/2025
GUL504 5119 ICU 01/15/2023 F 07/07/2025
GUL505 5165/5165A/5166 Patient Bedroom 01/15/2023 F 07/07/2025
GUL506 5167 Patient Bedroom 01/15/2023 F 07/07/2025
GUL507 5172 Patient Bedroom 01/15/2023 F 07/07/2025
GUL508 5173/5174/5175 Patient Bedroom 01/15/2023 F 07/07/2025
Sheet List
Sheet Number Sheet Name Issue Date Current Revision Current Revision Date
GUL001 FACILITY SIGNOFF 01/15/2023 G 01/26/2026
GUL002 SHEET INDEX 07/07/2025 G 01/26/2026
GUL003 GEN. INFO 01/15/2023 G 01/26/2026
GUL004 ATTACHMENT 01/15/2023 F 07/07/2025
GUL004.1 ATTACHMENT 01/15/2023 F 07/07/2025
GUL004.2 ATTACHMENT 01/26/2026 G 01/26/2026
GUL005 PROJECT DETAILS 01/15/2023 F 07/07/2025
GUL005.1 PROJECT DETAILS 07/07/2025 F 07/07/2025
GUL005.2 PROJECT DETAILS 07/07/2025 F 07/07/2025
GUL100 Level 0 - Overall 07/03/2025 F 07/07/2025
GUL101 B236 Morgue 01/15/2023 F 07/07/2025
GUL103.1 Bldg 1/Lvl 1_Overall - Ambulatory Area 07/07/2025 F 07/07/2025
GUL103.2 Bldg 1/Lvl 1_Overall - ED 01/15/2023 F 07/07/2025
GUL103.3 Bldg 1/Lvl 1_Overall - ED Triage 01/15/2023 G 01/26/2026
GUL103.4 Bldg 1/Lvl 1_Overall 07/07/2025 F 07/07/2025
GUL104 1013 Exam Room 01/15/2023 F 07/07/2025
GUL105 1021 Cast room 01/15/2023 F 07/07/2025
GUL106 1030 Procedure 01/15/2023 F 07/07/2025
GUL107 1066 Procedure 07/07/2025 F 07/07/2025
GUL108 1069 Hem/Onc 01/15/2023 F 07/07/2025
GUL109 1087 Procedure 07/07/2025 F 07/07/2025
GUL110 1096 Procedure 01/15/2023 F 07/07/2025
GUL111 1097/1097A Procedure 01/15/2023 F 07/07/2025
GUL112 1103A Toilet 01/15/2023 F 07/07/2025
GUL113 1184 Exam 07/07/2025 F 07/07/2025
GUL114 1189A Exam 07/07/2025 F 07/07/2025
GUL115 1189B Exam 07/07/2025 F 07/07/2025
GUL116 1192 Exam 07/07/2025 F 07/07/2025
GUL117 1193A Exam Neg Press 07/07/2025 F 07/07/2025
GUL118 1193B Exam Neg Press 07/07/2025 F 07/07/2025
GUL119 1195A Exam 07/07/2025 F 07/07/2025
GUL120 1195B Exam 07/07/2025 F 07/07/2025
GUL121 1195C Exam 07/07/2025 F 07/07/2025
GUL122 1197A Exam 07/07/2025 F 07/07/2025
GUL123 1199A Exam 07/07/2025 F 07/07/2025
GUL124 1199B Exam 07/07/2025 F 07/07/2025
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
Revision Schedule
Date Issued by Number
07/07/2025 YC F
01/26/2026 YC G
TYPE B / TYPE C / TYPE P
Fixed rail systems Fixed rail systems must be connected by Guldmann Service Team or by a qualified installer.
A Guldmann class I transformer must be used.
Installation to follow existing rules for authorized electricians and according to IEC/UL 60601-1.
Terminals on transformers Class I Double-insulated UL approved cable must be used (Cable specification: UL category: AVLV2, min.300V, min.
80° C, min. 18AWG (1 mm2 )) Transformer DK-13991 In:
Terminal 1 = N Terminal 2 = 100-115V AC Terminal 3 = 230V AC Terminal 4 = Protective ground Out:
Terminal 5 = 33V AC Terminal 6 = 33V AC
POWER TO BE WITHIN 15 FT OF END OF FIXED RAIL
Guldmann permanent mounted ceiling aluminium rail
Hoist with trolleys movable in rail
Protective Plast Enclosure
UL approved 400V cable, green, min. 14 AWG
Protective Ground
M1
UL approved 400V double isolated cable, min. 18 AWG
ON/OFF
UL approved 400V double isolated cable, min. 18 AWG
T ra n s fo rm e r
D K
-1
Main power Permanent installation Specification of breaker:
≥ 2.5 Amp capacity Line must always be broken
L1
AC/DC charger
Main Motor Control
Emergency Stop
Safety Circuit Emergency down
Motor Function Selector Switch0 1
V A
C
U S
V
A C
P ro te c tiv e G ro u nd
V A
C
V A
C1 A
T
.5
A T
Green Light ON (or ON / OFF - sign)
Licensed Electrician to perform hardwire to transformer
175 mm (6 3/4") 3 mm (1/8")
99 mm (4")
MINIMUM
100 mm (4")
WALL
MAX. WEIGHT LIMIT 375 KG (825 LBS) FOR SINGLE HOIST
MAX. WEIGHT LIMIT 500 KG (1100 LBS) FOR TWIN HOIST WITH 564040 TROLLEY
CENTERED IN DOORWAY
76.2 mm (3")
.2 m m
DOOR JAM
MODIFICATIONS TO DOOR
FRAME/HEADER DONE BY FACILITY
AND COORDINATED WITH GULDMANN
PATIENT LIFT
m m
/2
A
B
C
D
E
F
G
H
I
J
K
Ceiling bracket standard
A / B / C
Basic High M
Basic High M
Dimensions
205 mm
580 mm
345 mm
24 mm
58.5 / 125 / 170 mm
156 mm
184 mm
425 mm
2500 mm
970 mm
340 mm
8"
22.8"
13.5"
1.0"
2.2 / 4.9 / 6.6"
6.29"
7.2"
16.75"
98"
38"
13.3"
H
A
E D
F
C G
I
B
K J
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
GEN. INFO
GUL003
TRC01/15/2023
PROJECT ID:103067
NTS
GH3 TRANSFORMER
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
Revision Schedule
Date Issued by Number
01/15/2023 TRC A
03/01/2023 TRC B
07/07/2025 YC F
01/26/2026 YC G
TYPE B / TYPE C / TYPE P
INTERSTITIAL STEEL, SPAN = 4' - 0''
NTS
COMBI-LOCK (SHORT CUT)
NTS
DOOR HEADER HOIST PASSTHROUGH
NTS
GH3 PATIENT SLING DIMS
SCHEMATIC PLAN (ROOM COVER SYSTEM)
SUPPORT RAIL PROPERTIES-TYP
TYPICAL SUSPENSION ROD AT CEILING CONDITION
SUSPENSION
ROD
SEE GULDMANN SPAN BASED ON HOIST
4" MIN
SEE SCHEDULE BELOW
TYPE A, B, OR C
PARALLEL RAIL
(FIXED RAIL)
S E
E G
U L D
M A
N N
S P
A N
B A
S E
D O
N H
O
IS
T
PROVIDE INTERMEDIATE HANGER &
TWO-WAY BRACING (AT MID-SPAN
ONLY) WHERE RAIL SPAN EXCEEDS
THE LIMITS SCHEDULED BELOW.
RAILS ARE
MANUFACTURED
OF 6063-T6
ALUMINUM
Fu = 30,000 psi E = 10,100 psi
62mm
(2.44")
RAIL B
STD. NUT & LOCK WASHER
PARALLEL /
FIXED RAIL
1/2"Ø STD PIPE SPACER.
ENDS CUT SQUARE FOR
FULL BEARING EACH END.
CEILING TILE
FIRE CAULK
STD NUT (SNUG TIGHT),
LOCK WASHER
FIRE CAULK
PARALLEL RAIL /
FIXED RAIL
SEE BELOW
TYPICAL HANGER AND BRACE REQUIREMENTS
SUSPENSION ROD TO CONC. BEAM
SUSPENSION ROD TO STEEL BEAMS
CONCRETE FLOOR FRAMING
UNISTRUT PER
SCHED @
UNISTRUT PER
SCHED @
EXTEND UNISTRUT
TO TOE OF FILLET
BRACE CONNECTION AT CONC. FRAMING
CONCRETE FLOOR FRAMING
BRACE
CONCRETE
FLOOR FRAMING
BRACE PERPENDICULAR TO CONC. BEAM
BRACE PARALLEL TO CONC. BEAM
1/2" X 1-1/2" HEX BOLT, LOCK
WASHER, P3010 NUT,
EATON BLINE B335-2 1/2
THREE HOLE ADJUSTABLE
HINGE
BRACE - SKEW TO SIDE AND
LENGTHEN AS REQUIRED TO
REMAIN WITHIN 10° OF BEING
PERP OF PARALLEL TO RAIL
ALTERNATE: PROVIDE
STRUT BTWN CONC. BEAMS SIM TO
AND CONN. BRACE TO BOTTOM OF
STRUT w/ EATON BLINE B335-2 1/2
THREE HOLE ADJUSTABLE HINGE
FOR STRUT
SEE DETAIL
17/GUL415.1
GUL415.1
GUL415.1
GUL415.1
GUL415.1
GUL415.1
GUL415.1
GUL415.1
(E) STEEL BEAM
(E) STEEL BEAM
(E) STEEL BEAM
7 5
BRACE CONN. AT CONCRETE
GUL415.1
BRACE CONN. AT METAL PAN DECK11
NOTES FOR DETAIL 1
1. PROVIDE TWO-WAY SEISMIC BRACING AT EACH PRIMARY
HANGER LOCATION (4 PAIRS MINIMUM EACH INSTALLATION).
2. SEISMIC BRACES MAY BE ORIENTED 180° FROM THAT SHOWN.
3. BRACES MAY BE ± 10° FROM BEING PARALLEL TO THE RAILS AT
ANY LOCATION.
4. ONE OR MORE BRANCH LINES MAY BE PROVIDED AT ANY
LOCATION. PROVIDE HANGERS, BRACING, AND MAXIMUM SPANS
AS PER DETAIL 26/GUL415.1.
5. SEE DETAIL 5 ON THIS SHEET FOR HANGER AND BRACE
REQUIREMENTS.
PRIMARY
HANGER
BRANCH LINE HANGER
PRIMARY
HANGER
PRIMARY HANGER
LIFT SLIDES IN CROSS RAIL
AND CROSS RAIL SLIDES IN
PARALLEL RAILS
T Y
P E
A B
O
R C
C R
O S
S R
A
IL
(S L
ID
IN
G R
A
IL
COMBI-
LOCK
BRANCH RAIL,
WHERE OCCURS
BRANCH LINE
HANGER
PRIMARY HANGER
NOTE: ALL LATERAL MOVEMENT
OF THE PATIENT IS MANUAL,
MOTORIZED MOVEMENTS
NOT INCLUDED IN THIS OPM.
GUL415.1
GUL415.1
24 TYPICAL @ RAIL
INTERSECTIONS
WT (plf) 1.78 3.41 4.03
RAIL A RAIL B RAIL C
lx (in^4) 1.097 9.097 21.212
Sx (in^3) 0.918 3.671 17.415 ly (in^4) 1.130 1.971 2.355
Sy (in^3) 0.928 1.618 0.691
62mm
(2.44")
62mm
(2.44")
RAIL CRAIL A
m m
(6 .6 m m
(4 .9
.5 m m
(2 .3
4" MAX
M A
X
W.P.
W.P.
NOTES:
1. SEE DETAIL 5 FOR GENERAL HANGER AND BRACE REQUIREMENTS.
2. "DETAIL A" OR "B" IS OPTIONAL, DEPENDING ON WHERE THE PARALLEL RAIL IS SET
RELATIVE TO THE FINISH CEILING.
1/2"Ø STD PIPE SPACER,
ENDS CUT SQUARE FOR
FULL BEARING EACH END.
CEILING TILE
GULDMANN CEILING
BRACKET, SEE
FOR CONDITION A, THE
SUSPENSION ROD SHALL BE
LOCATED BETWEEN BEAM
CLAMPS, NOT OUTSIDE OF THE
BEAM CLAMPS.
SUSPENSION ROD CONN. CONC. & METAL PAN
-3
/4
M
IN
PART# INCLUDES M10 BOLTS AND ALL PARTS FOR BRACKET
TO RAIL CONN. SEE GENERAL NOTES FOR TORQUES REQUIREMENTS
GULDMANN PART# 550402
MANUFACTURED OF S235JRG2 STEEL
Fy = 22,300 psi (SWL limit = 1,430 LBS)
2 - 3/16"
55.5mm
2 - 3/16"
55.5mm
/1 m m
3/16"
5mm
1"
25mm
CEILING BRACKET DIMENSIONSGENERAL NOTES
GENERAL NOTES:
1. EARTHQUAKE DESIGN DATA:
DESIGN STANDARDS: ASCE 7-16
2022 CBC
RISK CATEGORY: IV
DESIGN SPECTRAL RESPONSE ACCELERATION PARAMETERS: SDS = 2.00 MAXIMUM
COMPONENT IMPORTANCE FACTOR: IP = 1.5
COMPONENT AMPLIFICATION FACTOR: aP = 2.5
COMPONENT RESPONSE MODIFICATION FACTOR: RP = 4.5
HORIZONTAL SEISMIC DESIGN FORCE: FP = 2.00WP
VERTICAL SEISMIC DESIGN FORCE: EV = 0.40WP
LIMITING DEFLECTION: L/360 FOR LIVE LOAD
DESIGN BASIS: ALLOWABLE STRESS DESIGN (ASD) IS USED FOR ALL MEMBERS EXCEPT
LOAD FACTOR RESISTANCE DESIGN (LRFD) IS USED FOR ALL POST-INSTALLED ANCHORS.
2. AT THE DISCRETION OF THE SEOR, THIS PROJECT IS SUBJECT TO SPECIAL INSPECTIONS.
SUBMIT REPORTS TO THE SEOR AND IOR. THE FOLLOWING SPECIAL TESTING AND
INSPECTION SERVICES SHALL BE PERFORMED BY A QUALIFIED TESTING AGENCY HIRED BY
THE OWNER:
2.1 REVIEW MILL CERTIFICATES *
2.2 TEST UNIDENTIFIED STEEL *
2.3 INSTALLATION TORQUE OF ALL BOLTING *
2.3.1 31 FT-LB FOR M10
2.3.2 50 FT-LB FOR 1/2" Ø
2.4 LOAD TESTING OF INSTALLED SYSTEM **
* - PERFORMED BY QUALIFIED TESTING AGENCY HIRED BY THE OWNER EXCEPT WHERE
THE IOR CAN PERFORM THE REQUIRED TESTING
** - PERFORMED BY INSTALLER, REVIEW BY IOR
3. STEEL GRADES:
MISC SHAPES & PLATES: ASTM A-36
PIPE: ASTM A-53, GRADE B
MACHINE BOLTS: ASTM A-307, SAE J429 GR 2
THREADED RODS: ASTM A-193 GRADE B7 ZINC COATED ALL-THREAD ROD
4. WORKMANSHIP AND DETAILS SHALL CONFORM TO THE PRODUCT MANUFACTURER'S
STANDARDS, AISC SPECIFICATIONS, ACI STANDARDS AND THE GOVERNING BUILDING CODE.
5. BOLT HOLES IN STEEL SHALL BE 1/16" LARGER IN DIAMETER THAN THE BOLT.
6. ANY FIREPROOFING REMOVED FROM THE (E) STEEL BEAMS SHALL BE REPLACED WITH SAME
THICKNESS OF THE SAME OR BETTER MATERIAL AND MEET ALL APPLICABLE APPROVED
PROJECT STANDARDS.
7. ALL UNISTRUT PARTS SHALL BE ELECTRO-GALVANIZED (EG) OR PRE-GALVANIZED (PG). CUT
ENDS AND SCRATCHING OF GALVANIZING SHALL RECEIVE A COAT OF COLD GALVANIZING
PAINT. B335-2 AND B335-4 HOLE HINGED CLIPS ARE PER THE EATON B-LINE PRODUCT LINE, DO NOT SUBSTITUTE.
8. ALL HARDWARE MAYBE SUBSTITUTED w/ EQUAL OR BETTER HARDWARE. SPECIFICATION OF
THE HARDWARE SHALL BE SUBMITTED FOR REVIEW AND APPROVAL BY THE SEOR AND HCAI.
9. AT SYSTEM CONNECTIONS TO THE SUPER-STRUCTURE, DO NOT USE A SINGLE DEVICE TO
ACCEPT MULTIPLE CONNECTIONS SUCH AS MULTIPLE HANGERS, HANGERS+BRACING, AND
ANY SUCH COMBINATION. EACH HANGER AND/OR BRACE SHALL HAVE IT'S OWN ANCHORAGE
TO THE SUPER-STRUCTURE.
10. GULDMANN PARTS MAY ONLY BE USED IF THE PART NUMBER IS REFERENCED ON THESE
DRAWINGS.
11. FOR ALL EXPANSION ANCHORS, SEE (DETAIL 28/GUL415.1).
12. SHEET METAL SCREWS SHALL BE HILTI SELF DRILLING SCREWS PER ESR-2196. MINIMUM
EDGE DISTANCE IS 1.5D, MINIMUM SPACING IS 3.0D, WHERE "D" IS NOMINAL SCREW DIAMETER.
13. ALL STUDS AND TRACKS SHALL BE MANUFACTURED BY CURRENT MEMBERS OF THE STEEL
STUD MANUFACTURERS ASSOCIATION (SSMA) PER ICC-ES REPORT ESR-3064P. ALL
MEMBERS 43 MIL OR LIGHTER SHALL BE MANUFACTURED PER ASTM A653 SS GRADE 33 AND
MEMBERS 54 MIL OR HEAVIER PER ASTM A653 SS GRADE 50, CLASS I. MEMBERS SHALL BE
UNPUNCHED.
14. FASTENING OF COLD FORMED METAL COMPONENTS SHALL BE WITH SELF-DRILLING SELF-
TAPPING SCREWS, USING THE SIZE INDICATED ON THE DETAILS. SCREWS SHALL CONFORM
TO ASTM C1513 AND HAVE A CORROSION-RESISTANCE COATING. SCREWS SHALL BE
INSTALLED IN ACCORDANCE WITH THESE DETAILS AND THE MANUFACTURERS
REQUIREMENTS AND FOLLOWING: SCREW THREADS SHALL TAP INTO AND SHALL ENGAGE
THE ENTIRE THICKNESS OF ALL PIECES JOINED, AND NOT LESS THAN THREE COMPLETE
THREADS SHALL PENETRATE BEYOND THE METALS JOINED. SCREW POINTS FOR SELF
DRILLING SCREWS SHALL BE SELECTED SO THAT DRILLING IS COMPLETED BEFORE THE
LEAD THREADS BEGIN ENGAGING METAL. PRE-DRILLED HOLE DIAMETERS SHALL NOT
EXCEED THE DIAMETER OF THE DRILL POINT.
15. DO NOT MAKE ANY CONNECTIONS IN THE PROTECTED ZONE OF SEISMIC STEEL FRAMING.
SEE PROJECT STRUCTURAL DRAWINGS FOR LOCATIONS. PROHIBITED CONNECTORS INCLUDE
WELDED, BOLTED, SCREWED, POWDER DRIVEN OR ANY OTHER CONNECTOR.
16. SEE 29/GUL415.1 FOR STATEMENT OF SPECIAL INSPECTIONS.
= ABOVE
= AMERICAN SOCIETY OF CIVIL ENGINEERING
= CALIFORNIA BUILDING CODE
= COMPONENT ENGINEER OF RECORD
= CONCRETE
= CONNECTION
= EXISTING (OR "BY OTHERS")
= FLOOR
= INSPECTOR OF RECORD
= MAXIMUM UNBRACED LENGTH OR CLEAR DISTANCE BETWEEN HINGES
= LIGHT-WEIGHT CONCRETE
= MAXIMUM
STANDARD ABBREVIATIONS16
ABV
ASCE
CBC
CEOR
CONC.
CONN.
(E)
FLR
IOR
LMAX
LWC
MAX
= METAL
= MINIMUM
= NORMAL WEIGHT CONCRETE
= POWDER DRIVEN FASTENER
= PERPENDICULAR
= ROOF
= SCHEDULE
= STRUCTURAL ENGINEER OF RECORD FOR THE BUILDING
= SIMILAR
= STANDARD
= WITH
MET
MIN
NWC
PERP
RF
SCHED
SEOR
SIM
STD
w/
TYPE A, B, OR C
PARALLEL RAIL
(FIXED RAIL)
BRANCH LINE HANGER
TRANSVERSE BRACE
NOTES - TYPICAL LIMITS FOR HANGERS AND BRACING
1. ALL OF THE LIMITS POSTED HEREIN THIS DETAIL SHALL BE OBSERVED DURING INSTALLATION OF HANGERS AND BRACES.
2. ANGLE OF BRACE TO HORIZONTAL SHALL BE BETWEEN THE LIMITS POSTED HEREIN.
3. THE ANGLE OF THE BRACE RELATIVE TO PARALLEL RAIL SHALL BE 0° ± 10° (BRACE PARALLEL) AND 90° ± 10° (BRACE PERPENDICULAR), IN OTHER WORDS, THE BRACE MAY DEVIATE FROM TRUE PARALLEL AND/OR PERPENDICULAR BY 10° MAX.
4. LENGTH OF BRACE SHALL NOT EXCEED LIMIT POSTED HEREIN.
5. THE BRACE SHALL INTERSECT THE HANGER ROD AT AN ELEVATION NO MORE THAN 8" ABOVE THE PARALLEL RAIL CEILING BRACKET.
6. THE HANGER ROD SHALL INCLUDE A "ROD STIFFENER" IS THE OVERALL LENGTH (DEFINED ABOVE) EXCEEDS LIMIT POSTED HEREIN.
M A
X
M A
X
M A
X
M A
X
M A
X
M A
X
M A
X
H A
N G
E R
S P
A N
M A
X
12' - 0"
M
AX.
BRACE S
PAN
° M
IN
° M
A X
1/2"Ø ALL-THREAD ASTM 193 GRADE B7
HANGER ROD, TYPICAL
WHEN THE "HANGER
SPAN" EXCEEDS 2' - 0"
PROVIDE P1000 ROD
STIFFENER
P2486 SEISMIC ROD
STIFFENERS,
2' - 0" MAX. SPACING
P10 00 B
RACE
(2) 1/2"-13 HEX HEAD CAP SCREW,
P3010 CHANNEL NUTS &
EATON BLINE (B335-2-1/2) THREE HOLE
ADJUSTABLE HINGE
TYPIC
AL
CEILING LINE
FIXED RAIL
GUL415.1
GUL415.1
BRACE CONN. AT STEEL FRAMING
BRACING TO STEEL FRAME WALL
M A
X
(E) STEEL BEAM
BRACE AS INDICATED ON PLAN
BRACE MUST BE PERPENDICULAR
TO THE STEEL BEAM
1/2"-13 MACHINE BOLT w/ LOCK
WASHER AND NUT THRU WEB
OF BEAM. FIELD DRILL 9/16"Ø
HOLE THRU WEB OF BEAM.
GUL415.1
TOP VIEW
BRACE AS INDICATED ON
PLAN - MAY BE PARALLEL
OR PERP TO UNISTRUT
SIDE VIEW
GUL415.1
4" MIN4" MIN
UNISTRUT P1000
FOR CONDITION A,
THE BRACE BRACKET SHALL
BE LOCATED BETWEEN
BEAM CLAMPS, NOT
OUTSIDE OF THE BEAM
CLAMPS.
TYPICAL HANGER AT FLAT SLAB13
1/2" X 1-1/2" HEX BOLT,
LOCK WASHER, P1010 NUT,
LS503-050 (B335-2-1/2)
HINGED BRACKET
NOTE: STRENGTH & ANCHORAGE OF PARTITION STUDS SHALL BE VERIFIED BY THE ENGINEER OF
RECORD. SEE "SEOR NOTES" ON THIS DRAWING FOR REQUIRED DESIGN FORCES.
(2) 1/2"-13 HEX HEAD CAP
SCREW, LOCK WASHER,
P3010 CHANNEL NUTS
& EATON BLINE
(B335-2-1/2) THREE HOLE
ADJUSTABLE HINGE
BRACE AS INDICATED ON
PLAN - MAY BE PARALLEL,
SKEWED OR PERP TO UNISTRUT
GUL415.1
BEAM CLAMP, SEE
(2) 1/2"-13 HEX HEAD CAP SCREW,
LOCK WASHER, P1010 CHANNEL
NUTS & LS503-050 (B335-2-1/2)
HINGED BRACKET
(E) STEEL BEAM
ADETAIL
BDETAIL
GUL415.1
BEAM CLAMP, SEE
UNISTRUT CLAMP P2867 (FOR P1000 & P1100),
P2867A (FOR P5000 & P5500) AND
P2867B (FOR P5001 & P5501) STRUTS.
BEAM CLAMP, SEE
GUL415.1
CDETAIL
BDETAIL
ADETAIL
FORMED SLAB TYPE AND THICKNESS SHALL CONFORM TO DETAIL 28/GUL415.1
REQUIREMENTS AND BE COMPOSED OF NORMAL WEIGHT CONCRETE ONLY.
FOR INFO NOT NOTED SEE DETAIL 9A
FOR NORMAL WEIGHT
CONCRETE SLABS ONLY!!
SEE 27/
GUL415.1
12" MIN 3" MIN
12" O.C. MIN
7"
MAX
5"
MIN
1/2" X 1-1/2" HEX BOLT, LOCK WASHER,
P3010 CHANNEL NUT & EATON BLINE
B335-2-1/2 THREE HOLE ADJUSTABLE
HINGE
GUL415.1
1" MAX
SEE 28/GUL415.1
D E
T A
IL
/G
U L
.1
1-1/2" MIN
3" MIN9-3/4" MIN
4"
MAX
2"
MIN
SEE 28/
GUL415.1
1/2" X 1-1/2" HEX BOLT,
LOCK WASHER, P3010
CHANNEL NUT & EATON BLINE
(B335-2-1/2) THREE HOLE
ADJUSTABLE HINGE
EQ EQ
FORMED SLAB TYPE AND THICKNESS SHALL CONFORM TO DETAIL 28/GUL415.1
REQUIREMENTS AND BE COMPOSED OF NORMAL WEIGHT CONCRETE ONLY.
METAL DECK DIMENSION & GAGE & TOPPING FILL THICKNESS AND TYPE FILL MUST
CONFORM TO DETAIL 28/GUL415.1.
FOR STRUT
SEE DETAIL
17/GUL415.1
NOTE:
THE BRACE-STRUT ASSEMBLY MAY BE ANCHORED PARALLEL, SKEWED OR PERPENDICULAR
TO THE METAL DECK RIBS BUT THE BRACE AND THE ANCHORED STRUT SHALL BE
PARALLEL TO EACH OTHER. LENGTHEN THE STRUT AT SKEWED CONDITIONS SO THAT
ANCHOR LOCATION WITHIN THE RIB COMPLIES TO THE REQUIREMENTS NOTED ABOVE.
NOTE:
THE BRACE-STRUT ASSEMBLY MAY BE ANCHORED PARALLEL, SKEWED OR PERPENDICULAR
TO THE METAL DECK RIBS BUT THE BRACE AND THE ANCHORED STRUT SHALL BE
PARALLEL TO EACH OTHER. LENGTHEN THE STRUT AT SKEWED CONDITIONS SO THAT
ANCHOR LOCATION WITHIN THE RIB COMPLIES TO THE REQUIREMENTS NOTED ABOVE.
DEAD CENTER BETWEEN THE
EXPANSION ANCHORS.
IF BRACE IS PARALLEL TO
DECK FLUTES, SET THE W.P.
THE BRACE W.P. MAY
BE OFFSET 1" EITHER SIDE
FROM THE LOCATION
SHOWN IN THE DIAGRAM.
FOR NORMAL WEIGHT
CONCRETE SLABS ONLY!!
1" MIN, TYP.
FOR STRUT SEE DETAIL
17/GUL415.1
'a' (MIN)
SEE ABV
L = 12" MIN 1-1/2" MIN BOTH ENDS
(NO HANGER ALLOWED
OUTSIDE THE ANCHORS)
SEE 28/GUL415.1, MAINTAIN
REGARDLESS OF STRUT TO
DECK RIB ANGLEHANGER ROD &
STIFFENERS, SEE
NOTE: IF STRUT IS
PARALLEL TO DECK
FLUTES, USE a = .5L
TYPICAL FOR ALL
HOIST LOADS.
LOAD RATING
MINIMUM a/L
SCHEDULE - HANGER LOCATION 'a/L' LIMITS THE HANGER CAN BE NO CLOSER
TO EITHER EXPANSION ANCHOR
THAN DIMENSION 'a'. IF HANGER
MUST BE CLOSER, USE "DETAIL B".
P1047 w/ 1/2"-13 HEX CAP SCREW
& P3010 CHANNEL NUTS TO P1000
DO NOT DRILL HOLES
THRU BEAM FLANGES!
NOTES:
1. IF THE HANGER LOCATION 'a' CANNOT BE OBTAINED VIA "DETAIL A", "DETAIL B" MUST
BE USED.
2. IF STRUT IS PARALLEL TO DECK FLUTES & a/L IS SET TO 0.50 MIN, "DETAIL B" IS NOT
REQUIRED FOR ALL HOIST LOAD RATINGS.
SECTION AA
BDETAIL
ADETAIL
METAL DECK DIMENSION & GAGE &
TOPPING FILL MUST CONFORM TO
DETAIL 28/GUL415.1
(TYP "DETAIL A" AND "B").
BDETAIL
ADETAIL
GUL415.1
HANGER ROD &
STIFFENERS, SEE
UNISTRUT PER
SCHED @17
GUL415.1
1/2" X 2-1/4" HEX BOLT,
NYLOCK NUT, WASHER,
EATON BLINE B335
FOUR HOLE
ADJUSTABLE HINGEA
B
(TWIN)
L O
A D
L
IM
IT
C A
N T
IL
E
V E
R (S
IN
G
L E
C
R O
S S
C A
N T
IL
E
V E
R
F
IX
E D
S P
A N
(B E
T W
E E
N S
U P
P O
R T
S
C A
N T
IL
E
V E
R (S
IN
G
L E
C
R O
S S
C A
N T
IL
E
V E
R
F
IX
E D
S P
A N
(B E
T W
E E
N S
U P
P O
R T
S
C A
N T
IL
E
V E
R (S
IN
G
L E
C
R O
S S
C A
N T
IL
E
V E
R
F
IX
E D
S P
A N
(B E
T W
E E
N S
U P
P O
R T
S
RAIL A RAIL B RAIL C
18 ¾
10 ¾
15 ¼
15 ¾
16 ½
24 ¾
16 ½
21 ¼
22 ½
24 ¾
29 ½
22 ¼
25 ¾
28 ¼
30 ¾
LBS
INCH
.50
.50
1,100
.50
-1
/2
M
IN
HANGER ROD CAN OCCUPY ANY POSITION BETWEEN B335 CLIPS.
PL 3/4x1-5/8"x0'-3" (ASTM A36) w/
(2) 13/16"Ø HOLES, PLACE
BETWEEN HEAD OF BOLT AND
B335 CLAMP, TYPICAL.
UNISTRUT P1000
4" MIN
NO HANGER ALLOWED
4" MIN
NO HANGER ALLOWED
4" MIN
NO HANGER ALLOWED
4" MIN
NO HANGER ALLOWED
1/2" X 1-1/2" HEX
BOLT, LOCK
WASHER, P3010
NUT, EATON BLINE
B335-2-1/2 THREE
HOLE ADJUSTABLE
HINGE
PLATE WASHER 1/4x1-52x1-1/2"
GUL415.1-
3-1/2"
L = 12" MIN
L = 12" MAX
'a' 1" MIN
12" MAX
12" MIN
HANGER NOT
PERMITTED
3/4"
MIN
P1000 A
A
A
A
FOR STRUT
SEE DETAIL
17/GUL415.1
P1047
2-11/16" 2-11/16"
MIN
ISOMETRIC - P1728
DO NOT USE
THESE HOLES
(2) TYPE B
EXPANSION
ANCHORS PER
GUL415.1
D E
T A
IL
/G
U L
.1
28/GUL415.1
DETAIL
28/GUL415.1
DETAIL
D E
T A
IL
/G
U L
.1
D E
T A
IL
/G
U L
.1
GUL415.1
(2) TYPE B
EXPANSION
ANCHORS PER
GUL415.1
GUL415.1
GUL415.1
(2) TYPE B
EXPANSION
ANCHORS PER
GUL415.1
(2) TYPE B
EXPANSION
ANCHORS PER
GUL415.1
(1) TYPE A
EXPANSION
ANCHORS PER
GUL415.1
FOR NORMAL WEIGHT
CONCRETE SLABS ONLY!!
FOR NORMAL WEIGHT
CONCRETE SLABS ONLY!!
(1) TYPE B
EXPANSION
ANCHORS PER GUL415.1
M
IN
GUL415.1
GUL415.1
(2) TYPE B
EXPANSION
ANCHORS PER
P1728 (SEE ISOMETRIC BELOW
FOR ORIENTATION) w/ (2) TYPE
B EXPANSION ANCHORS PER
28/GUL415.1. NOTE: DEWALT
ANCHORS MAY NOT BE USED
FOR THIS CONNECTION. USE
BEVELED WASHERS TO MAKE
BRACKET PLUMB.P1000 MIN, EXTEND TO PARTITION
STUDS ON BOTH SIDES OF THE
CONNECTION POINT. FOR METAL
STUD PARTITIONS, FASTEN USING
(1) #12 S.M.S. TO EACH STUD. FOR
WOOD STUD FRAMING, FASTEN
USING (1) SD10212 (#10x2-1/2")
TO EACH STUD.
METAL
OR WOOD
PARTITION
STUD WALL
(SEE NOTE)
P2486 SEISMIC ROD
STIFFENER CLAMPS,
SPACE PER DETAIL 5/-
FOR STRUT
SEE DETAIL
17/GUL415.1
PLATED STEEL WASHER
AT EACH SCREW
OPM - 0735 / GUL415
Brace, Total Axial
Brace, Horizontal Component Brace, Vertical Component
Hanger, Min
Hanger, Max
Rail
-72 1,045
-68 1,389
-68 1,323
-173 1,037
-159 1,332
-137 1,554
-273 1,063
-241 1,360
A A A B B B C C
Hoist 605 Lbs 825 Lbs 1,100 Lbs 605 Lbs 825 Lbs 1,100 Lbs 605 Lbs 825 Lbs
ASD
LRFD
LRFD
ASD
ASD
Basis
-206 1,620
C
1,100 Lbs
DESIGN LOADS BY HOIST RATING AND RAIL TYPE (Lbs)
Gravity
Gravity+
Seismic
Lbs, LRFDVertical Force, at Base of Post
Out of Plane Lateral Force, anchors spaced along the length 20 20 65 176
1,955 1,274 65 176
Lateral Force, Top of Post at Wall, Parallel to Wall
Lateral Force, Top of Post at Wall, Perpendicular to Wall
OPM-0735
SEOR PLEASE NOTE
1. The Engineer-of-Record (SEOR) to verify the building structure is adequate to support the new equipment and support framing loads to be installed per this drawing.
2. The equipment may be one of two types, or a combination of both:
Type 1: "Room Cover System" per Detail 1 and 5/GUL415, and/or Type 2: "Upright Support" per Details on GUL415.2
3. Type 1 "Room Cover System" loads: Select the values corresponding to the proposed Hoist Type and Rails to be used:
Table Notes:
1. These loads are based on ASCE7-16 load combinations that include Dead, Live and Seismic Loadings. Additionally, hanger axial loads include dynamic load factors for movement and impact in the gravity cases.
2. "Hanger loads" represent the load in any given hanger and do not reflect design loads in the various anchorage devices. Hanger values less than zero indicate net compression considering all effects. These values do not include any Ωo amplification.
3. "Bracing" loads represent the load in any given brace and do not reflect design loads in the various anchorage devices. These values reflect the worst case for any brace angle, Θ where Θ can vary between 25 and 60 degrees from the horizontal. These values do not include any Ωo amplification.
Table Notes:
1. Forces result from ASCE7-16 LRFD Load combinations. These values do not include any Ωo amplification.
2. The lateral force due to gravity is the force required for stability of the top of post.
4. Type 2 "Upright Support" loads:
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
ATTACHMENT
GUL004
TRC01/15/2023
PROJECT ID:103067
Revision Schedule
Date Issued by Number
01/15/2023 TRC A
03/01/2023 TRC B
03/28/2023 KIT D
07/07/2025 YC F
17 SUSPENSION POINT AT OBSTRUCTION
OBSTRUCTION
OBSTRUCTION
UNISTRUT TRAPEZE
PER SCHEDULE BELOW
A
/4
T
Y P
IC
A
L
F
IT
T
IN
G T
H
IC
K N
E S
S
1/2"Ø LOCK WASHER
HANGER ROD
1/2"Ø ALL THREAD
1/2"Ø HEX NUT
P1064 FLAT PLATE OR FITTING
FOR 1/2"Ø HARDWARE
P3010 CHANNEL NUT
STRUT, SEE DETAIL 17/GUL415.1
JAMB 1/2"Ø THREADED HANGER ROD
UP TO BOTTOM OF CHANNEL
/4
T
Y P
IC
A
L
F
IT
T
IN
G T
H
IC
K N
E S
S
1/2"Ø HEX NUT
1/2"Ø HEX NUT
1/2"Ø LOCK WASHER
P1064 FLAT PLATE
OR FITTING FOR
1/2" HARDWARE
BACK TO BACK UNISTRUT
HEADER PER
SCHED @
1/2"Ø THREADED HANGER
ROD FIELD DRILLED
THROUGH BACK TO BACK
UNISTRUT
P1064 FLAT PLATE
OR FITTING FOR
1/2" HARDWARE
1/2"Ø LOCK WASHER
HANGER ROD
1/2"Ø ALL THREAD
TYPICAL THROUGH-BOLT UNISTRUT
CHANNEL HANGER ROD CONNECTION
TYPICAL UNISTRUT CHANNEL HANGER ROD
CONNECTION
19 18
SEE DETAILS 9 THRU 15 ON GUL415
FOR CONN. TO STRUCTURE ABV
SEE DETAILS 9 THRU 15 ON GUL415
FOR CONN. TO STRUCTURE ABV
SUSPENSION AND BRACING FOR COMBI-LOCKS
COMBI-LOCKA-RAIL
CROSS RAIL
CEILING
FIRE CAULK
MINIMUM 1/2"Ø
STD PIPE SPACER
UNISTRUT P5000
UNISTRUT P1000
1/2" X 1-1/2" HEX BOLT,
LOCK WASHER, P3010 NUT,
LS503-050 (B335) HINGED
BRACKET
P2486 ROD STIFFENER
@ OC 20" AND 1" MAX
EA. END
UNISTRUT P1000
PROVIDE BRACE PARALLEL TO UNISTRUT AT ONE SUPPORT POINT AND PERPENDICULAR
TO UNISTRUT AT BOTH SUPPORT POINTS. SUPPORT POINT AT OPPOSITE END OF RAIL
WOULD THEN NOT REQUIRE A BRACE PARALLEL TO THE RAIL.
TYPICAL SINGLE UNISTRUT CHANNEL BOLTED
CONNECTION
/4
T
Y P
IC
A
L
F
IT
T
IN
G T
H
IC
K N
E S
S
-3
/1
M
IN
B O
L T
L E
N G
T H
STRUT, SEE DETAIL
17/GUL415.1
P3010 CHANNEL NUT
UNISTRUT FITTING FOR 1/2"Ø
HARDWARE
1/2"Ø LOCK WASHER
1/2"Ø X 1-3/16"
(MIN LENGTH) BOLTS
1/2"
7/8" CLEARANCE FOR
SOCKET WRENCH
FIELD DRILL 1/2" DIA
HOLES FOR 1/2"Ø HILTI
KB-TZ2 ANCHORS INSTALLED
PER DETAIL 28 ON
SHEET GUL415.1 (BASED ON
DECK TYPE).
STRUT, SEE DETAIL
17/GUL415.1
ANCHOR INTO CONCRETE
CROSS RAIL TO PARALLEL RAIL CONNECTION24
PART# INCLUDES M10 BOLTS AND ALL PARTS FOR RAIL TO RAIL CONN.
SEE GENERAL NOTES FOR TORQUE REQUIREMENTS
UNDERHUNG
ENDSTOP BY GULDMANN
EA END OF CROSS RAIL AND
PARALLEL RAIL
PARALLEL RAIL w/
ENDSTOP BY GULDMANN
EA END
BOXED HUNG
PARALLEL RAIL w/ ENDSTOP
BY GULDMANN EA ENDCROSS RAIL
ENDSTOP BY GULDMANN
EA END OF CROSS
RAIL AND PARALLEL RAIL
TRAVERSE TROLLEY BY GULDMANN
(S235JRG2 STEEL)
PART# 550076 (825 LBS CAP)
(554189 FOR PARALLEL RAIL
FLUSH TO CLG, 825 LBS CAP)
OR PART# 550078 (1100 LBS CAP)
(554546 FOR PARALLEL RAIL
FLUSH TO CLG, 1100 LBS CAP)
CROSS RAIL
GULDMANN CEILING
BRACKET KIT
GULDMANN
PARALLEL RAIL (FIXED RAIL)
(E) STEEL BEAM
½" HEX NUT,
STRUT NUT,
P1064
SUSPENSION ROD MAY ATTACH
ANYWHERE BETWEEN CLAMPS
SECTION ABOVE STEEL FRAMING23
PARALLEL RAIL
(FIXED RAIL)
11-3/4" O.C.± 6" ± 6"
HANGER ASSEMBLY,
SEE
FOR INFORMATION NOT
NOTED, SEE DETAIL
5/GUL415
PARALLEL RAIL
(FIXED RAIL)
UNISTRUT P1000
CEILING
PROVIDE SUSPENSION
ROD EA SIDE OF GAP
FIRE CAULK
PROVIDE PERP BRACE AND PARALLEL
BRACE AT EACH SUSPENSION ROD
RAIL GAP FOR CURTAIN
SEE DETAILS 9 THRU 15 ON GUL415
FOR CONN. TO STRUCTURE ABV
SCHEMATIC SECTION UNDER CONC. FRAMING
CONCRETE FLOOR
FRAMING
CEILING
PATIENT
LIFT
(LIVE LOAD)
GH3 LIFT MECHANISM
CROSS RAIL: CAN BE MOUNTED
FLUSH TO OR BELOW
SUPPORT RAIL PER: 24
31SCHEMATIC SECTION UNDER STEEL FRAMING
(E) STEEL BEAM
PARALLEL RAIL
(FIXED RAIL)
GH3 LIFT MECHANISM
PATIENT
LIFT
(LIVE LOAD)
CEILING
3"
MIN
5HANGERS AND
BRACING SHALL
CONFORM TO
GUL415
GUL415
GUL415
GUL415HANGER MAY BE PLACED ANYWHERE
ALONG THESE LIMITS, TYPICAL
UNISTRUT PER SCHEDULE
GUL415
TYP
MAXIMUM SPAN
(DETAIL 17)
MAXIMUM SPAN
(DETAIL 17)
PARALLEL RAIL
(FIXED RAIL)
PRIMARY HANGER PER 5/GUL415
DETAIL - HIGH BRIDGE
GUL415
NOTES:
1. THE "PRIMARY HANGER" CONNECTS THE GULDMANN RAIL TO THE TRAPEZE ABOVE AND
THE "SECONDARY HANGERS" CONNECT THE TRAPEZE TO THE STRUCTURE ABOVE.
SEE DETAIL"A" ABOVE FOR ILLUSTRATION.
2. IN ALL CASES, PRIMARY HANGERS MUST BE CONNECTED TO A HORIZONTAL STRUT TO
ALLOW DISTRIBUTION TO THE SECONDARY HANGERS AS SHOWN. THE MAXIMUM SPAN
BETWEEN SECONDARY HANGERS SHALL MEET THE LIMITS POSTED IN THE SCHEDULE
BELOW. THIS APPLIES TO THE CONDITIONS ILLUSTRATED HEREIN AND APPLIES
WHEREVER THIS DETAIL IS INVOKED OR CALLED OUT.
3. EACH UNISTRUT TRAPEZE ASSEMBLY SHALL BE BRACED IN TWO DIRECTIONS USING
APPROVED BRACING CONNECTED AT THE TOP OF THE STRUT AS ILLUSTRATED IN
DETAIL "A" ABOVE. PROVIDE A BRACE PERPENDICULAR TO THE TRAPEZE AT EACH
SECONDARY HANGER LOCATION AND PROVIDE A SINGLE BRACE PARALLEL TO THE
TRAPEZE AT EITHER SECONDARY HANGER LOCATION.
4. CANTILEVERED TRAPEZE BEAM ARE NOT ALLOWED, SEE DETAIL "B". PRIMARY HANGERS
SHALL BE LOCATED BETWEEN THE SECONDARY HANGER LOCATIONS, NO EXCEPTIONS.
5. PRIMARY & SECONDARY HANGERS AND ALL BRACING SHALL COMPLY WITH DETAIL
5/GUL415 AND SHALL BE ANCHORED USING DETAILS CALLED OUT ON 5/GUL415.
BDETAIL - CANTILEVER
HOIST
RATING
1,100
MAXIMUM SPAN (CENTER TO CENTER OF HANGERS) - INCHES
P1000
P1001
P5000
P5500
P5501
P5001
NOT
ALLOWED
HANGERS SHALL NOT BE
SUPPORTED BY
CANTILEVERED UNISTRUT
TRAPEZES
SECONDARY HANGERS
PER 5/GUL415
PROVIDE BRACING PERPENDICULAR
TO THE TRAPEZE AT ALL SECONDARY
HANGERS, AND PROVIDE ONE BRACE
PARALLEL TO THE TRAPEZE STRUT
AT EITHER SECONDARY HANGER
LOCATION
PRIMARY HANGER MAY OCCUPY
ANY LOCATION WITHIN THE
MAXIMUM SPAN
TWO-WAY BRACING
REQUIRED AS PER
DETAIL 1/GUL415
MAXIMUM SPAN (SEE SCHEDULE)
CEILING TILE
UNISTRUT P2785
BEAM CLAMP TYPICAL
MAXIMUM SPAN
(DETAIL 17)
UNISTRUT PER
1'-6"
MAX
3"
MIN
3"
MIN
1-5/8"
MAX
4" MIN
8" MAX
4" MIN
8" MAX
BENT PL. 1/2" x 3"
(ASTM A36 MIN)
BEAM FLANGE
3/4" MAX
STRUT, SEE DETAIL
17/GUL415.1
PLAN
7/16"Ø
STD NUT PLUS LOCK WASHER, TORQUE NUTS
TO 20 FOOT-LBS, STAKE THREADS.
BEAM CLAMP DETAIL
SECTION
T .B
.D
/4
M
IN
/4
7/8" 1-1/8" THESE ARE MINIMUM DIMENSIONS AND
THE RATIO BETWEEN THESE TWO
DIMENSIONS SHALL BE HELD FIRM, I.E.
RATIO = 1.125/.875 = 1.2857
* DISCARD THE TWO-HOLE CLAMP PLATE THAT COMES
WITH THESE U-BOLTS, AND PROVIDE THE CLAMP
PLATE DETAILED HERIN.
FOR P1000 STRUTS, USE P2785*
FOR P1001 STRUTS, USE P2786*
FOR P5000 STRUTS, USE P2786*
FOR P5001 STRUTS, USE P2787*
FOR P5500 STRUTS, USE P2786*
FOR P5501 STRUTS, USE P2787*
3/8"Ø U-BOLT, SOURCED FROM UNISTRUT AS
FOLLOWS:
** CENTER-TO-CENTER HOLE SPACING TO SUIT THE
U-BOLT CLAMP, NOMINALLY 2" BUT CONFIRM BEFORE
FABRICATING.
HANGER ROD
10mmØ ALL THREAD
THIS DETAIL MAY ONLY BE USED
WHEN THERE IS NOT FLOOR
AND/OR ROOF DECK BEARING ON
THE TOP FLANGE.
BENT PLATE IS TO BE MANUFACTURED USING
ASTM A36 CARBON STEEL, Fy=36 KSI OR ANY
SUPERIOR STEEL GRADE.
25 FLUSH PARALLEL RAIL AT CEILING
SPRING CLIPS
CEILING T-BAR
CEILING PANEL
GULDMANN FLUSH PROFILE (15MM ALUMINUM, SNAPS INTO RAIL)
MAINTAIN 3/4" GAP ALL AROUND
RAIL. DO NOT ATTACH T-BAR
RUNNER OR CLG PANEL TO
FLUSHING OR RAIL.
PARALLEL SUPPORT RAIL
#12 WIRE HANGER @ 4'-0" O.C. w/ NO LESS THAN THREE (3)
TIGHT TURNS. HANGER WIRE LOOPS SHALL BE TIGHTLY
WRAPPED AND SHARPELY BENT TO PREVENT ANY
VERTICAL MOVEMENT OR ROTATION OF THE T-BAR WITHIN
THE LOOP. MAINTAIN 6" SEPARATION FROM ANY DUCTS.
CEILING WIRE SHALL CONFORM WITH GALVANIZED SOFT
ANNEALED MILD STEEL AS DEFINED IN ASTM A641
(CLASS 1 COATING) WITH 70 KSI MINIMUM TENSILE
STRENGTH.
8"
MAX
NOTE: ANY ALTERATIONS TO CEILING SYSTEM SHALL BE
MADE IN ACCORDANCE WITH THE DESIGN PROFESSIONAL
OF RECORD'S RECOMMENDATIONS.
IF THE RAIL MUST DISPLACE OR CAUSE TO BEND ANY SPLAY
WIRES, RELOCATE SPLAY WIRES AND ASSOCIATED
COMPRESSION STRUTS IN ACCORDANCE WITH THE DESIGN
PROFESSIONAL OF RECORD'S RECOMMENDATIONS.
PROVIDE STANDARD T-BAR BOTH SIDES OF RAIL, TO REST
ON TOP OF GULDMANN FLUSH PROFILE.
STEEL POP RIVET @ 4'-0" AND/OR ANY T-BAR INTERSECTION
EXPANSION ANCHOR GENERAL NOTES
1. ANCHORS SHALL BE HILTI KB-TZ2 PER ESR-4266, OR DEWALT POWER STUD+SD2 PER
ESR-2502 OR SIMPSON STRONG BOLT STB2 PER ESR-3037 ONLY. DO NOT SUBSTITUTE
ANCHORS FROM OTHER MANUFACTURERS, OTHER MODELS, OR OTHER DIAMETERS & HOLE
DEPTHS. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE LISTED
MANUFACTURERS ICC-ESR PRODUCT APPROVAL, IN ACCORDANCE WITH THE "SCHEDULE
FOR ANCHORS AND MINIMUM REQUIREMENTS" BELOW, AND IN ACCORDANCE WITH THE
DIAGRAMS BELOW.
2. ANCHORS SHALL BE INSTALLED INTO THE SOFFIT OF A METAL DECK & CONCRETE FILL
SYSTEM, OR INTO THE SOFFIT OF A FORMED CONCRETE SLAB. METAL DECK SHALL BE
2 OR 3-INCH "W" TYPE COMPOSITE METAL DECKING ONLY. MINIMUM CONCRETE STRENGTH
SHALL BE f'c = 3,000 PSI. FOR METAL DECK FLOOR SYSTEMS, CONCRETE MIX MAY BE
NORMAL WEIGHT OR LIGHT WEIGHT CONCRETE. FOR FORMED FLOOR SYSTEMS, NORMAL
WEIGHT CONCRETE ONLY SHALL BE USED.
3. ANCHOR PLACEMENT SHALL NOT VIOLATE THE MINIMUM SPACING AND EDGE DISTANCE
LIMITS POSTED IN THE "SCHEDULE OF ANCHORS AND MINIMUM REQUIREMENTS" BELOW.
4. EXPANSION ANCHORS INSTALLED SHALL NOT NICK OR DAMAGE SLAB REINFORCING; USE
NON-DESTRUCTIVE TESTING TO VERIFY REINFORCING LOCATIONS AND INSTALL NEW
ANCHORS 1" CLEAR OF SUCH REINFORCING. SHOULD SLAB REINFORCING BE
INADVERTENTLY DAMAGED, NOTIFY THE RDP IN RESPONSIBLE CHARGE IMMEDIATELY.
5. ANCHORS SHALL NOT BE USED IN PRESTRESSED CONCRETE UNLESS NON-DESTRUCTIVE
TESTING METHODS ARE USED TO LOCATE PRESTRESS STEEL STRANDS, AND HOLES ARE
LOCATED 1" CLEAR OF SUCH STRANDS. IF STRANDS ARE INADVERTENTLY NICKED OR
DAMAGED, NOTIFY THE GENERAL CONTRACTOR AND RDP IN RESPONSIBLE CHARGE
IMMEDIATELY.
6. THESE ANCHORS SHALL HAVE SPECIAL INSPECTION AND TESTING IN ACCORDANCE WITH
THE SPECIAL INSPECTION REQUIREMENTS POSTED BELOW, DETAIL 31/GUL415.1.
28 EXPANSION ANCHOR GENERAL NOTES
ANCHORS NOT ALLOWED INTO
SOFFIT OF UPPER FLUTE
M
IN
T
O P
P
IN
G T
H
IC
K N
E S
S S
E E
S C
H E
D U
L E
MAX. 1"
OFFSET,
TYP.
MIN TOTAL THICKNESS
PER SCHEDULE BELOW
MIN. 20GA
STEEL W-DECK
LOWER FLUTE
EXPANSION ANCHOR
PER TABLE BELOW, TYP
SECTION - COMPOSITE DECK SECTION - SLAB OR BEAM
O R
D E
C K
S O
N L Y
12" MIN., TYP.
1"
MIN
4½" MIN 4½" MIN
GENERAL
1. SPECIAL INSPECTIONS SHALL COMPLY WITH ALL APPLICABLE PROVISIONS OF THE 2022
CALIFORNIA BUILDING CODE, CHAPTER 17A AND CHAPTER 19A, SECTION 1910A.5
2. QUALITY ASSURANCE TESTS AND INSPECTIONS SHALL BE THE RESPONSIBILITY OF THE
OWNER. THE OWNER SHALL RETAIN A TESTING AGENCY WHO SHALL PERFORM THE
REQUIRED TESTS AND INSPECTIONS AND SHALL PREPARE WRITTEN SUMMARY REPORTS OF
ANY TEST OR INSPECTION, AND SUBMIT SAME TO THE INSTALLER AND THE IOR.
3. THE EQUIPMENT INSTALLER SHALL NOTIFY THE OWNER'S TESTING AGENCY OF THE DATES
OF ALL WORK IN NEED OF INSPECTION OR TESTING. NOTIFICATION SHALL BE SUFFICIENTLY
IN ADVANCE TO ALLOW SCHEDULING OF INSPECTIONS AND TESTS, NOT LESS THAN
24 HOURS ADVANCE NOTIFICATION.
4. THE INSTALLER SHALL NOTIFY THE INSPECTOR OF RECORD (IOR) OF ANY PENDING
INSPECTIONS AND TESTING, AND SHALL NOTIFY THE IOR OF ANY INSPECTIONS OR TESTS
THAT FAIL THE ACCEPTANCE CRITERIA.
29 STATEMENT OF SPECIAL INSPECTIONS
EXPANSION ANCHORS
1. SPECIAL INSPECTION SHALL BE AS WRITTEN IN THE ICC-ESR PRODUCT APPROVALS LISTED
ABOVE. THE SPECIAL INSPECTOR SHALL MAKE PERIODIC INSPECTIONS AT LEAST ONCE OF
EACH DAYS ANCHOR INSTALLATION TO VERIFY ANCHOR TYPE, ANCHOR DIMENSIONS,
CONCRETE TYPE, CONCRETE COMPRESSIVE STRENGTH, ANCHOR SPACING, EDGE
DISTANCES, CONCRETE MEMBER THICKNESS, TIGHTENING TOURQUE, HOLE DIMENSIONS,
ANCHOR EMBEDMENT AND ADHERENCE TO MANUFACTURERS PRINTED INSTALLATION
REQUIREMENTS.
2. THE PERMITTED ANCHORS LISTED ABOVE ARE TORQUE CONTROLLED ANCHORS AND SHALL
BE TESTED USING A CALIBRATED TORQUE WRENCH TO VERIFY INSTALLATION TORQUES OF
50 FT-LBS FOR ALL HILTI KB-TZ2 ANCHORS, 40 FT-LBS FOR DEWALT POWERSTUD+SD2
ANCHORS OR 60 FT-LBS FOR SIMPSON STRONG BOLT 2 ANCHORS.
3. VERIFY TORQUE FOR 100% OF THE ANCHORS INSTALLED IN ONE DAYS WORK.
4. ACCEPTANCE CRITERIA: TORQUE-CONTROLLED POST-INSTALLED ANCHORS SHALL BE
TESTED WITH A CALIBRATED WRENCH AND SHALL ATTAIN THE SPECIFIED TORQUE WITH
ONE-HALF (1/2) TURN OF THE NUT.
GULDMANN MANUFACTURED COMPONENTS
1. VERIFY THE GENERAL SIZE, SHAPE AND MATERIAL CERTIFICATIONS FOR GULDMANN RAILS, BRACKETS AND CUSTOM MANUFACTURED ALUMINUM & STEEL COMPONENTS.
MATERIAL PROPERTIES ARE LISTED ON THE DETAILS.
UNISTRUT CONSTRUCTION
1. PERIODIC SPECIAL INSPECTION PER 2022 CBC SECTION 1705A.13.3 FOR SEISMIC RESISTANCE, INCLUDING CONNECTION ASSEMBLIES, SIZES AND GRADES AND ALL FASTENERS.
THERE ARE NO WELDED CONNECTIONS.
TYPE
A
B
A
B
A
B
ANCHOR
DIAMETER
MIN. EFFECTIVE
EMBED, h'EF
MIN. DEPTH
OF HOLE
1/2" 2-1/2" 3-1/4"
1/2" 3-1/4" 4-1/4"
1/2" 2" 2-3/4"
1/2" 3-1/4" 4"
1/2" 2-1/2" 3"
1/2" 3-1/4" 4-1/8"
MIN.
TOPPING
THICKNESS
MIN. TOTAL
THICKNESS
MINIMIM
SPACING
AT
Simpson STB2 per ESR-3037
DeWalt PS-SD2 per ESR-2502
HILTI KB-TZ2
per ESR-4266
MAKE
MINIMUM
EDGE DIST.
MIN.
SPACING
2-1/2" 5" 7-1/2"@
NOTE: MIN. SPACING AND/OR EDGE DISTANCES CAN BE REDUCED IF NOTED ON SPECIFIC DETAILS.
4-3/4"
2-1/4"5-1/4" or 2"
2-3/4"
4"6" or 6"
2-3/4"
4"4" or 6"
4"
6"6" or 4"
2-3/4"
4"4" or 12"
8"
2-3/4"9-3/4" or 3"
2-1/2"
3-1/4"
3-1/4"
1-1/2"
1-1/2"
5-1/2"
5-3/4"
6"
4" or 5-1/2"
4-1/2" or 6"
9-3/4"
6"
9-3/4"
7-1/2"
9-3/4"
AT
DECK SOFFITS
AT SOLID SLAB OR BEAMSSCHEDULE ANCHORS AND MINIMUM REQUIREMENTS
M A
X
M10 NUT PLUS LOCK WASHER.
NUT SHALL BE SNUG TIGHT AT
INSTALLATION
OPM - 0735 / GUL415.1
OPM-0735
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
ATTACHMENT
GUL004.1
TRC01/15/2023
PROJECT ID:103067
Revision Schedule
Date Issued by Number
01/15/2023 TRC A
03/01/2023 TRC B
03/28/2023 KIT D
07/07/2025 YC F
1 5/8" STEEL DBL CHANNEL,
OR EQUAL DETERMINED
BY DELEGATED DESIGN
SUBCONTRACTOR
HINGED BRACKET CONNECTOR
BY DELEGATED DESIGN
SUBCONTRACTOR
SPRING NUT
CONNECTORS DETERMINED
BY DELEGATED DESIGN
SUBCONTRACTOR
BRACE WHERE OCCURS
STEEL CHANNEL BRACKET
CLIPS DETERMINED
BY DELEGATED DESIGN
SUBCONTRACTOR
Wx BEAM
COLD ROLL DBL CHL INFILL BLOCK
BY 24" LONG FOR BOLT CLAMP
THRU GYPBOARD
(E) POURED GYPSUM SLAB @
B11 (E) CEILING AT B1
ANCHOR ROD
DETERMINED BY
DELEGATED DESIGN
SUBCONTRACTOR
CEILING
VARIES, VERIFY IN FIELD
TRANSVERSE
BRACE
LONGITUDINAL BRACE
COLD ROLL DBL CHL INFILL BLOCK BY 24"
LONG FOR BOLT CLAMP THRU GYPBOARD
(E) POURED GYPSUM
SLAB AT B11
(E) SUPT BMS OF
INTERSTITIAL FRAMING
COLD ROLL DBL CHL SUPT AND CONNECTOR CLAMPS
BY DELEGATED DESIGN SUBCONTRACTOR
ANCHOR ROD
DETERMINED BY
DELEGATED DESIGN
SUBCONTRACTOR
HINGED BRACKET
CONNECTOR
BY DELEGATED DESIGN
SUBCONTRACTOR
BOLTED CONN BY
DELEGATED DESIGN
SUBCONTRACTOR
SCALE : NTS4
DETAIL AT BLDG 11 AND SIM FOR BLDG 1
SCALE : NTS5
DETAIL AT BLDG 11 AND SIM FOR BLDG1
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
ATTACHMENT
GUL004.2
YC01/26/2026
PROJECT ID:103067
Revision Schedule
Date Issued by Number
01/26/2026 YC G
STRUCTURE DETAIL FROM P01 VA SD - PATIENT LIFTS Designs - 664-CSI-203 - IFC - 2025-02-07 1_Part3 (1).pdf
DETAIL 4-5/S1.10
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
/2
H O
IS
T
/4
C -R
A
IL
T R
A V
E R
S E
C E
IL
IN
G
GUL005
H
O
IS
T
/4
T R
A V
E R
S E
C E
IL
IN
G GUL005
/4
H O
IS
T
/2
T R
A V
E R
S E
C E
IL
IN
G
GUL005
12'' MIN
/2
/4
/2
C-RAIL
B-RAIL
12'' MIN
/4
/2
/4
12'' MIN
/8
/4
/2
/4
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
PROJECT DETAILS
GUL005
TRC01/15/2023
PROJECT ID:103067
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
Revision Schedule
Date Issued by Number
01/15/2023 TRC A
03/01/2023 TRC B
07/07/2025 YC F
TYPE B / TYPE C / TYPE P
3/4" = 1'-0"
B236 ELEVATION
3/4" = 1'-0"
TYPE B. ELEVATION
3/4" = 1'-0"
TYPE C. ELEVATION
1 1/2" = 1'-0"
B236. CEILING DETAIL
1 1/2" = 1'-0"
TYPE B. CEILING DETAIL
1 1/2" = 1'-0"
TYPE C. CEILING DETAIL
H O
IS
T
T R
A V
E R
S E
C E
IL
IN
G
/4
C O
M B
I- L
O C
K
GUL005.1
GUL005.1
/4
H O
IS
T
T R
A V
E R
S E
C E
IL
IN
G
GUL005.1
SEE GUL003
/2
/4
8'' MIN
/8
/8
/2
COMBI-LOCK
B-RAIL A-RAIL
/8
/4
8'' MIN
SEE GUL003
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
PROJECT DETAILS
GUL005.1
YC07/07/2025
PROJECT ID:103067
Revision Schedule
Date Issued by Number
07/07/2025 YC F
3/4" = 1'-0"
TYPE P. ELEVATION
3/4" = 1'-0"
TYPE P. ELEVATION. MONORIEL SECTION
1 1/2" = 1'-0"
TYPE P. CEILING DETAIL
1 1/2" = 1'-0"
TYPE P. COMBI-LOCK
1 1/2" = 1'-0"
TYPE P. ELEVATION. MONORIEL SECTION. CEILING DETAIL
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
/8
H O
IS
T
/4
T R
A V
E R
S E
C E
IL
IN
G B
E D
R O
O M
C E
IL
IN
G B
A T
H R
O O
M
GUL005.2
GUL005.2
/8
/4
GUL005.2
/4
/8
/2
/4
/8
8'' MIN
90mm SPACERS
/4
/8
/4
/2
COMBI-LOCK
STRUT
SPACERS
(100mm)
B-RAIL A-RAIL
8'' MIN
/2
SEE GUL003
/4
/8
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
PROJECT DETAILS
GUL005.2
YC07/07/2025
PROJECT ID:103067
Revision Schedule
Date Issued by Number
07/07/2025 YC F
3/4" = 1'-0"
1097/1097A PROCEDURE. ELEVATION
3/4" = 1'-0"
1097/1097A PROCEDURE. MONORIEL SECTION
1 1/2" = 1'-0"
1097/1097A PROCEDURE. CEILING DETAIL
1 1/2" = 1'-0"
1097/1097A PROCEDURE. COMBI-LOCK DETAIL
1 1/2" = 1'-0"
1097/1097A PROCEDURE. MONORIEL SECTION. CEILING DETAIL
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
P1 P2 P3
P4 P5 P6
S1 S2 S3 S4
FEC FEC FEC FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
LIFT
TUNNELMORGUE
B236
DW
UP
UP
UP
UP
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
Level 0 - Overall
GUL100
YC07/03/2025
PROJECT ID:103067
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
Revision Schedule
Date Issued by Number
07/07/2025 YC F
1" = 30'-0"
Level 0 - Overall
TYPE B / TYPE C / TYPE P
1 ROOM / 1 SYSTEM
MORGUE
B236
/2
/8
2' - 0" 16' - 3 7/8"
GUL005
/2
/2
16' - 1 1/2"
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
B236 Morgue
GUL101
TRC01/15/2023
PROJECT ID:103067
Revision Schedule
Date Issued by Number
01/15/2023 TRC A
03/01/2023 TRC B
07/07/2025 YC F
3/8" = 1'-0"
B236 Morgue
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0''
ATTACHMENT TYPE =4.
B-RAIL FIXED / C-RAIL TRAVERSE
B rail
Ceiling bracket, Extended
Hoist
Stabilizers
KEY
Hoist Transformer
C rail
Hoist Coverage Area
1080A
TOILET
1126A
EXAM 12
EXAM 13
EXAM 14
EXAM 15
HAC
PROCEDURE
HEM/ONC
PROCEDURE A
PROCEDURE B
EXAM 5
RESTROOM
1097A
CAST ROOM
PROCEDURE
EXAM ROOM
TOILET
1103A
9'-0"
9'-0"
8'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
EXAM
EXAM
COOR OFF.
HAS OFF.
BULL PEN
MD
WORKROOM
SW422
EXAM
SW426
MEDICATION
ROOM
SW434
SOILED
UTILITY RM.
SW414
EXAM
SW432
EXAM
SW436
EXAM
SW440
CLEAN SUPPLY
ROOM
SW430
EXAM
SW424
EXAM
SW442
EXAM
SW444
EVS
SW410
STOR.
SW445
HALL A
SW409
HALL B
SW407
HALL C
SW435
HALL D
SW425
CLINIC
COORD.
SW438
ELECTRICAL
SW402
EXAM
SW412
EXAM
SW408
EXAM
SW404
SIGNAL
CLOSET
SW416
I.T.
CLOSET
SW450
STAFF TLT.
SW446
PUBLIC
TOILET
SW401
GURNEY
ALCOVE
SW
A- FLO R - P FIX
A- W ND W
A- FLO R
A- D EC K
A- C LN G- H LID
I- SIG N
I- M ILL
I- P RTNI- C SW K
S -FRAM -BEAM
S -FRAM -JO IS
M - H VAC- R D FF
M - H VAC - SD FF
M - H VAC
E - LITE
A L L D I S CI P L IN E S L A YE R S
AR C H ITEC TU R AL
M EC H AN IC AL
E LEC TR IC AL
P LUM B IN G
IN TER IO R S
FIR E
P R O TECTIO N
EQ U IP M EN T
STR U C TU R AL
E- IN TC - W ALL
E- IN TC- C LN G
E- IN TC- C IR C
E- P OW R - SW B D
E- P OW R - PAN L
E- C O M M- W ALL
E- C OM M - CLN G
E- CO M M- C IR CE- C AB L- TR AY
E - LITE- W ALL
P - SAN R - VEN T
P - SAN R- P IP EP - SAN R - SU P P
P - SAN R - EQ P M
F- SP R N- H EADF- SP R N- P IP E
M - M DG S- PIP E
M - H VAC- P IP E
M - H VAC - SU P P
M - H VAC- R ETN
S- W ALL
S- TR U S
S- STR S
S - SLABS- JO IS
S- C O LS- G R ID
S- D EC K
S- B EAMS- B R AC
A- R O O F- LEVL
A- R O O F- O TLN
A - FLO R - LEVL
A- FLO R - O TLN
A- FLO R - TP TN
A- D OO R - DM IS
A- W ALL- D M IS
A- FLO R - R ISR
S -ST RU-O VHD
M - H VAC - EQ P M
A - P ATT - 0050
A- SITE- D EC K
A - P ATT - 0040
A- AR EA
X- R D M E
I- FUR N
CHAIR
CHAIR
S- FN D N
A- G LAZ- ID EN
A- R O O F
F- SPR N - CLH D
E- LITE- C IR C
A - G LAZ- SILL
A- G LAZ
A- W ALL- W N B DA- W ALL- STU D
A- W ALL- P R H T
A - W ALL- FU LL
A- D OO R - ID EN
A- O VH D- B LK S
A- O VH D- B LK F
A- O VH D - AW N G
A- FLO R - STR S
S- C O LS
P - SAN R- FLD R
M - H VAC- C D FF
A- FLO R - WD W K
Q - EQP M - ID EN
Q - EQ P M- C LN GQ - EQP M - HID E
Q - EQP M
Q - EQP M - REFG
E- LITE- C LN G
E- P O W R- W ALL
A - P ATT - 0030
A - P ATT - 0020
A - W ALL- P ATT
A- W ALL- JAM B
A- D OO R
A - P ATT - 0010
A -FL O R-P ATT
M - H VAC - EXH S
A- W ALK
A- P RO P
A -CLNG
A- C LN G- SU SP
PHASE 1 PHASE 2
PHASE 3
CONSTRUCTION WALL
RECEPTION + WAITING
11E
GUL104
GUL105
GUL106
1GUL107
GUL108
GUL109
GUL111
GUL110
GUL112
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
Bldg 1/Lvl 1_Overall - Ambulatory Area
GUL103.1
YC07/07/2025
PROJECT ID:103067
Revision Schedule
Date Issued by Number
07/07/2025 YC F
1" = 10'-0"
Level 1 - Ambulatory Area
10 ROOMS / 9 SYSTEMS
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
F.E.
EXAM 4
1199D
EXAM 3
1199C
EXAM 2
1199B
EXAM 1
1199A
EXAM 5
EXAM 6
EXAM 9
1189A
EXAM 10
1189B
EXAM 11
1189C
EXAM 12
EXAM/NEG.
PRESS. 13
1193A
EXAM/NEG.
PRESS. 14
1193B
EXAM 21
1197D
EXAM 20
1197C
EXAM 19
1197B
EXAM 18
1197A
EXAM 17
1195C
EXAM 16
1195B
EXAM 15
1197A
9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0"
9'-0"
9'-0"
9'-0"
9'-0"9'-0"9'-0"
9'-0"9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
CORRIDOR
TEL/COM
DATA
HALL
1217C
MEDS
TLT
CLEAN STOR.
SUPPLIES LINEN
NURSE
STA.
WORK
PHYSICIANS CHARTING
HALL
1217B SOILED
HALL
PAT.
TLT.
NURSE
STA.
NURSE
STA. NURSE
STA.
HALL
OFFICE
GUL113
GUL115
GUL116
GUL117
GUL118
GUL119
GUL120
GUL121
GUL122
GUL123
GUL114
GUL124
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
Bldg 1/Lvl 1_Overall - ED
GUL103.2
TRC01/15/2023
PROJECT ID:103067
Revision Schedule
Date Issued by Number
01/15/2023 TRC A
03/01/2023 TRC B
07/07/2025 YC F
1" = 10'-0"
Level 1 - ED
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
METAL PAN
TYPE B / TYPE C / TYPE P
19 ROOMS / 19 SYSTEMS
OFFICE
OFFICE
CORR
OFFICE
OFFICE
PREP
MED
EXAM 1
EXAM 2
EXAM 3
TOILET
HAC
CORR
NURSE
WAITING
PROCEDURE
ROOM 2
BAY 7
1123J
BAY 6
1123I
BAY 5
1123H
EXAM
1123C
EXAM
1123B
EXAM
1123A
9'-0"
9'-0" 9'-0"
9'-0"
9'-0"
F
DW-1
032-1-1
1174E
1174B
1174A
1174F
1174C
1174D
1168035-1-1
1167A
1174A
DUMB
WAITER
VOID
KITCHENETTE
COUNTER
CONSULT
PHARMACY
OFFICE
OFFICE(S)
STAIR
VAULT
OFFICE
AUDIOMETRIC EXAM RM
SOUND BOOTH
EXAM RM
VOID
EXAM
RM
VESTIBULE
1128A CORRIDOR
CLINIC
WAITINGSW200
GUL125
GUL126
GUL127
GUL128
GUL129
Guldmann Inc.
14401 McCormick Drive Tampa FL, 33626 Unit A
Toll Free: 1(800)-664-8834 Fax: 1(813)-880-9558
Email: Info@Guldmann.net
NOTES
APPROVED BY:
PROJECT NAME:
SHEET DESCRIPTION:
SHEET NO:
DATE: DRAWN BY:
VA SD BLDG 1
Bldg 1/Lvl 1_Overall - ED Triage
GUL103.3
TRC01/15/2023
PROJECT ID:103067
Revision Schedule
Date Issued by Number
01/15/2023 TRC A
03/01/2023 TRC B
07/07/2025 YC F
01/26/2026 YC G
1" = 10'-0"
Level 1 - ED Triage
7 ROOMS / 5 SYSTEMS
HOIST = 825 LBS1.
NON - RECESSED /2.
CEILING HEIGHT = 9' - 0 ''3.
AFF TO DECK = 13' - 0'' (VIF)
ATTACHMENT TYPE =4.
ULTRASOUND
POOL
PHYSICAL
THERAPY
9' -0"
10' -0"
9' -0"
50 OCC.
62 OCC.
LINE OF CONSTRUCTION
050-1-1
020-1-1
047-1-1
056-1-1
068-1-1
052-1-1
055-1-1
057-1-1
058-1-1
061-1-1
010-1-1
011-1-1
018-1-1
017-1-1
026-1-1
023-1-1
021-1-1
067-1-1
022-1-1
1280B
1280A
SW8-1 SW7-1
SW6-1
SW5-1
054-1-1
053-1-1
1326A
14661467
1478A
1468B1468A
1478B1478C
14831488
1481A
1481B
1481C
1493D
1494B
1494C
1494A
1493 I1493H1494
1493E
1493C
1491A
049-1-1
1493F
1493J
1493G
1499C
046-1-1
1496A
1493B
051-1-1
1493A
1492A
P6P5P4
1492B
1492C
1497D
1403 1497C
1497B
1497D
1497A
1497E
1323 1349
1425A
143514341433
P3P2P1
1355A
S1 S2
S3 S4
1381A
1359A
1377A
060-1-1
059-1-1
1415C
1415A 1415B
1368A
S3-1-1
1409A
1408 1407
1285 1287
SW13-1
1304C
1304A
1308A
024-1-1
1316A
1837 1837A
18331832
1829A1829
1823A1823
1242E
1242B
1248 1279
1242D
1242C
123912401241
1816A
18021801A
1808D
1808A
1808C
1808B
1820 1821
1810A
1233A
OUTDOOR COURTYARD
SPID CLINIC
RECEPTION
HEALTH ASSESSMENT CLINIC
VOID
VET OF
FOREIGN
WARS OF
THE UNITED
STATES
TOILET(P)
VOID
VOID
VOID
WASH
ALCOVE
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
VOID
OFFICE
MALE
TOILET
RESTROOM
OFFICE
GENERAL STORAGE
TOILET(S)
DRESS
DRESS
GENERAL STORAGE
TOILET(P)
FEMALE
TOILET
MALE
TOIL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .