1. Access Control System Requirements. The Contractor will provide a system that meets the following tasks:

A. (16) Multi-Format Card Readers with a 1-year license. The card readers will connect to a door controller in the termination room and have a back-up battery for uninterrupted power should an outage occur.

B. Technical Specifications – Door Card Reader

• Near Field Communications (NFC)

• Data Encryption Standard Fast Innovative Reliable and Secure (DESFire)

• MIkron FARE Collection System (MIFARE)

• Serial RS-485

• Black

• Hybrid-Cloud Capable

• LED Indicators

• Wired

C. Technical Specifications – Cloud License

• 1-year license coverage

• Cloud-Based Management Platform

• Real-time Analytics on Access Events

• Integration into Azure Active Directory Platform

D. Technical Specifications – Door Access Controller

• Wired

• Gigabit Ethernet Interfaces

• 350 watt Power Consumption

• Ac 110-240 volt Required Voltage

• Max Operating Temperature = 122 degrees Fahrenheit

• Min Operating Temperature = 32 degrees Fahrenheit

• Can control up to (16) doors

• Black

• Compliant with CSA C22.2 No. 62368-1, EN 60839-11-1, FCC Part 15 Class B, ICES-

003 Class B, IEC 62368-1, NDAA, RCM, UKCA, UL 294, UL 62368-1, VCCI Standards

E. Technical Specifications – Backup Battery

• 18 Ah Battery Capacity

2. Installation Locations. The (16) door readers will be installed at the following listed locations. A map is provided and a walkthrough will be available. Additional requirements for the installation diagrams and topology are included in para 5.

1. 6103 – Conference Room

2. 6104 – Information Technology Services Branch – Chief

3. 6105 – Information Technology Services Branch – Staff

4. 6106 – Headquarters and Operations Branch

5. 6107 – Deputy, Chief Information Officer/G6

6. 6108 – Resource Management and Acquisitions – Staff (Main Door)

7. 6108 – Resource Management and Acquisitions – Chief

8. 6109 – Break Room

9. 6110 – Chief Information Officer/G6

10. 6111A – Client and Technical Services Branch (i.e. – Goldcoats) – Chief

11. 6111B – Client and Technical Services Branch (i.e. – Goldcoats) – Equipment Storage

12. 6111C – Information Technology Services Branch – Contractors

13. 6111D– Educational Technology Branch

14. 61XX – Door Near 6110 (No Room Number)

15. 61XX – Back Hallway Door near 6109 (No Room Number)

16. 61XX – Client and Technical Services Branch – Entry Door