This file is the United States Fire Administration (USFA) Board-Up Guidelines, a technical specification document referenced in support of the Santa Monica Fire Department's Emergency Board-Up Services Request for Qualifications. The guidelines provide detailed, standardized procedures for boarding up window and door openings in buildings, including specific measurements, material specifications, installation sequencing, and safety protocols. The document outlines the step-by-step boarding process, from cutting plywood flush with exterior molding to securing braces with carriage bolts and washers, with particular attention to brace placement and positioning. The guidelines also specify exit procedures for interior workers, requiring personnel to depart through an elevated window at least 10 feet above ground before the final exit point is sealed. This technical specification serves as the operational standard for contractors responding to the Santa Monica Fire Department's RFQ for Emergency Board-Up Services due November 6, 2026.

The materials specifications detailed in the guidelines include 3/8-inch plywood (grade CDX), 2-inch by 4-inch by 8-foot construction-grade lumber, 3/8-inch by 12-inch carriage bolts with rounded heads, 3/8-inch construction-grade nuts, and flat washers meeting specified diameter requirements. Hardware selections include 1-5/8-inch galvanized or stainless steel shank nails or comparable deck nails. The guidelines establish uniform technical standards for all contractors performing emergency board-up services within the jurisdiction, ensuring consistency and structural adequacy across all installations. No pricing information, contract value, set-asides, or funding sources are detailed in this technical specification document; contractors must refer to the primary RFQ for those procurement details.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix A

UNITED STATES FIRE ADMINISTRATION (USFA) BOARD-UP GUIDELINES

Boarding up:

1. Cut plywood to fit over the window and door openings, flush with the outside of the molding. Note:

For buildings with metal door and window frames, the alternative is to cut the plywood and 2x4’s to fit the inside of the door frame butted up against the band molding.

2. Cut the 2x4’s to fit the horizontal dimension of the plywood. You will need two 2x4 exterior and two interior braces for each window and three sets for each door. For buildings with metal doors and window frames, the 2x4’s for the outside will be cut to the dimensions of the plywood, fitting inside the door frame against the band molding. For the inside, the 2x4’s will be cut to the outside dimension of the door or window frame.

3. Pre-drill 3/8” holes in the plywood and the braces.

4. The holes will be placed approximately 1/3 of the length of the brace from each outside edge of the door and window.

5. The two window braces will be placed 1/3 of the distance from the top and the bottom of the window.

6. The three door braces will be placed: one in the center of the doorway, one half of the distance from the center to the top, and one to the bottom of the doorway.

7. Place the plywood over the exterior opening and nail to the frame. For metal frames, place the plywood and braces inside the frame against the band molding.

8. Place the 2x4 braces over the interior and exterior of the door or window.

9. Place the large washer over the carriage bolt and place the bolt through the holes.

10. Place washer and nut inside and tighten securely. Torque the nut so that it slightly compresses the interior 2x4. After all entrances are secured, the interior worker should exit the building, using a ladder, through a window, if such exists, at least 10’ above the ground. Nail or screw a plywood sheet over the worker’s exit. Patrol the building periodically to check the security.

GTE: Use round head 3/8” carriage bolt, 12” long (course thread) wrench neck, 1/2” standard flat washer, and 3/8” course construction grade nut.

Materials Needed:

1. ½” plywood, grade CDX and 2”x4” by 8’ construction grade lumber.

2. 3/8” x 12” carriage bolts (rounded head on weather side).

3. 3/8” construction grade nuts.

4. Flat washers with an inside diameter large enough to bypass the wrench neck inside the carriage bolt head so no lift edge is available beneath an installed carriage bolt head.

5. ½” diameter flat washers for installation beneath the nut inside the building.

6. 1-5/8” (6d) galvanized or stainless steel shank nails or comparable deck nails.