This Technical Requirements Document (TRD) details the government's procurement specifications for a shielded enclosure cabinet for a UHF radio at Eglin Air Force Base. The required cabinet must have a 70dB Radio Frequency Interference rating from 20 MHz to 3.29 GHz, 40dB EMI protection, compliance with Mil-Std-461F and Mil-Std-810G, and specific configuration requirements including 120 VAC power entry, passive ventilation, front and rear access doors, and a 10 RU rack mount configuration.

Key additional requirements include no Wi-Fi, WiDi, or Bluetooth capabilities, only new and unused products, and Trade Agreements Act (TAA) compliance. The delivery is to be made FOB Destination at Eglin AFB, FL within 90 to 180 days After Receipt of Order. Acceptance criteria involve verifying form, fit, and function compatibility with the UHF radio, confirming TAA compliance, and validating warranty and support documentation. The cabinet must be between 26-30 inches wide, 26-30 inches tall, and 30-32 inches deep, with a 2-inch Myers Hub for equipment cabling.

View the file

Other files

File Type Posted
DEADLINES.pdf PDF
Combo.pdf PDF
DEADLINES.pdf PDF
FA282325Q0083 SF 1449.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Government Technical Requirements Document (TRD)

8/6/2025

Technical Requirements Document (TRD) – Shielded Enclosure Cabinet for UHF Radio

1. Introduction

This TRD outlines the technical requirements for the procurement of a shielded cabinet to house and protect a UHF radio from electromagnetic and radio frequency interference at Eglin AFB.

2. System Requirements

2.1 Product Specifications:

Specific Configuration:

o 70dB Radio Frequency Interference rating from 20 MHz to 3.29 GH o 40dB EMI protection rating o Compliant with Mil-Std-461F and Mil-Std-810G o 120 VAC power Entry with internal power distribution o Passive ventilation with louvers o Front and Rear Access doors o Copper grounding for equipment with and cabinet o 10 RU configuration rack mount with battery tray with 10-32 tapped mounting holes o At least 26” wide by 26” tall by 30” deep, but no bigger than 30” by 30” by

32” o 2” diameter Myers Hub to accommodate equipment cabling

2.3 Connectivity Restrictions:

The systems must NOT include any Wi-Fi, WiDi, or Bluetooth capabilities.

2.4 Condition:

Only new, unused products will be accepted.

2.5 Documentation:

The delivery shall include the standard manufacturer's warranty documentation.

2.6 Compliance:

All delivered products must be Trade Agreements Act (TAA) compliant.

3. Delivery and Logistics

Delivery Location: FOB Destination, Eglin AFB, FL 32542

Delivery Timeframe: 90 to 180 days After Receipt of Order (ARO)

4. Acceptance Criteria

Verification of form, fit, and function compatibility with UHF radio.

Confirmation of TAA compliance.

Verification of warranty and support documentation.