TP09 Final Drawings - 24 Pages 657-24-119JC.pdf
PDF 27 MB Posted
- Attached to
- Z2DA--657-24-119JC, Create GI Anesthesia Procedure Room 6th. Floor, John Cochran (VA-25-00074423)
- Solicitation number
- 36C25525R0113
About this file
These are detailed architectural and engineering drawings for a construction project to create a new GI Anesthesia Procedure Room on the 6th floor of the John Cochran VA Medical Center in St. Louis, Missouri. The project involves renovating approximately 418 square feet of existing space, including converting rooms A612, A613, A613A, and A613B into a fully functional GI procedure room with two new patient holding areas. The project scope includes demolition of existing walls, installation of new medical gas and plumbing systems, electrical modifications, mechanical system updates, and integration of new medical equipment.
The project documents include comprehensive technical specifications across multiple disciplines, including architectural plans, electrical, mechanical, plumbing, fire protection, and technology infrastructure drawings. Key elements include installing new medical equipment like an electrosurgical unit, patient monitoring systems, storage cabinets, and specialized medical gas and electrical connections. The renovation will comply with 2024 NFPA 101 Life Safety Code and other relevant healthcare construction standards. The project is part of VA Project Number 657-24-119JC, with design documents prepared by Design-Aire Engineering and dated February 28, 2025, indicating a planned near-future construction timeline.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
JOHN COCHRAN VA MEDICAL CENTER
Create GI Anesthesia Procedure Room, 6th Floor
US DEPARTMENT OF VETERANS AFFAIRS
ST. LOUIS VA HEALTH CARE SYSTEM
VA PROJECT NUMBER: 657-24-119JC
OVERALL CAMPUS SITE PLAN, BUILDING NUMBER, AND PROJECT LOCATOR
CONTACT INFORMATION
COR: Mr. Ayele Belayneh, PE
Healthcare Engineer, Design & Construction, Facility Engineering Services VA Saint Louis Health Care System 314-652-4100 x 69100JB Ayele.Belayneh@va.gov
DAE: DAVE HAUN
Project Manager 317-464-9090 DHaun@daengineering.com
PROJECT LOCATION
BUILDING SCHEDULE
1 MAIN HOSPITAL & CLINICAL ADDITION
1A EMERGENCY GENERATOR VAULT
1B EMERGENCY GENERATOR VAULT
1T MODULAR BUILDING
2 EDUC., MED. MEDIA, CHAPEL & RESRCH.
2T METHADONE CLINIC
2T2 OATP CLINIC
3 IRM & RESEARCH
4 NON-VA CARE / AFGE
5T OEF/OIF
6 RESEARCH
6A RESEARCH
7 RESEARCH
7A RESEARCH
8 BOILER PLANT
8A CHILLER PLANT
8B EMERGENCY GENERATOR
8C CHILLER BUILDING
9 PARKING GARAGE - UNDER CONST.
10 FLAG POLE
11 GAS METER HOUSE
12 BRINE TANKS
14 GARAGE
16 ENGINEERING / TRANSITION CARE TEAM
17 SWITCH GEAR BUILDING
24 WASTE STORAGE FACILITY
29 UNDER CONSTRUCTION
DEC DECON TRAILER
OVERALL CAMPUS SITE PLAN
PROJECT LOCATOR
PROJECT BUILDING
LOCATION
2T
2T2 1A
1B
6 6A7
8B11
1T
5T 14 3
E
G
H
J
BELL AVE.
ENRIGHT AVE.
DELMAR AVE.
SP
R
IN
G
S T.
G R
AN
D
A
VE
EMPLOYEE PARKING
YELLOW
VALET PARKING
PURPLE
8A 7A
29BUILDING
(NON VA)
DEC
P
EMPLOYEE PARKING
YELLOW
L
PATIENT PARKING
BLUE
VACANT LOT
(NON VA)
UNDER
CONSTRUCTION
AMEREN MISSOURI
SUBSTATION
UP
DOWN
UP
F
PHYSICIAN PARKING
RED
EMPLOYEE PARKING
YELLOW
R Q
PATIENT PARKING
BLUE
A
A
PATIENT PARKING
BLUE
PATIENT PARKING
BLUE
8C
EMPLOYEE PARKING
YELLOW
SALT
STORAGE
N M
S
TO
IN
TE
R
ST
AT
E
TO
IN
TE
R
ST
AT
E
1-GI-001
GENERAL COVER SHEET
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
02/28/25
CONTRACT DOCUMENTS ISSUED FOR BIDDING
CREATE GI ANESTHESIA PROCEDURE
ROOM, 6th FLOOR
657-24-119JC
Saint Louis VA Health Care System John Cochran VA Medical Center
915 N Grand Blvd, St. Louis, MO 63106
DEH DAE
FULLY SPRINKLERED
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text
FH
AutoCAD SHX Text
FH
AutoCAD SHX Text
LOADING DOCK PAD
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
PE-2021014461
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text
HANNAH ROSE KIGER
2T
2T2 1A
1B
6 6A7
8B11
1T
5T 14 3
E
G
H
J
BELL AVE.
ENRIGHT AVE.
DELMAR AVE.
SP
R
IN
G
S T.
G R
AN
D
A
VE
EMPLOYEE PARKING
YELLOW
VALET PARKING
PURPLE
BUILDING SCHEDULE
1 MAIN HOSPITAL & CLINICAL ADDITION
1A EMERGENCY GENERATOR VAULT
1B EMERGENCY GENERATOR VAULT
1T MODULAR BUILDING
2 EDUC., MED. MEDIA, CHAPEL & RESRCH.
2T METHADONE CLINIC
2T2 OATP CLINIC
3 IRM & RESEARCH
4 NON-VA CARE / AFGE
5T OEF/OIF
6 RESEARCH
6A RESEARCH
7 RESEARCH
7A RESEARCH
8 BOILER PLANT
8A CHILLER PLANT
8B EMERGENCY GENERATOR
8C CHILLER BUILDING
9 PARKING GARAGE - UNDER CONST.
10 FLAG POLE
11 GAS METER HOUSE
12 BRINE TANKS
14 GARAGE
16 ENGINEERING / TRANSITION CARE TEAM
17 SWITCH GEAR BUILDING
24 WASTE STORAGE FACILITY
29 UNDER CONSTRUCTION
DEC DECON TRAILER
8A 7A
29BUILDING
(NON VA)
DEC
0' 200'
300'
400'
500'100'
SCALE REFERENCE
P
EMPLOYEE PARKING
YELLOW
L
PATIENT PARKING
BLUE
VACANT LOT
(NON VA)
UNDER
CONSTRUCTION
AMEREN MISSOURI
SUBSTATION
UP
DOWN
UP
F
PHYSICIAN PARKING
RED
EMPLOYEE PARKING
YELLOW
R Q
PATIENT PARKING
BLUE
A
A
PATIENT PARKING
BLUE
PATIENT PARKING
BLUE
8C
EMPLOYEE PARKING
YELLOW
SALT
STORAGE
N M
S
TO
IN
TE
R
ST
AT
E
PROJECT LOCATOR
TO
IN
TE
R
ST
AT
E
PROJECT LOCATION
1-GJ-001
OVERALL SITE PLAN FOR
PROJECT CONSTRUCTION
OVERALL SITE PLAN
SCALE: 1" = 200'-0"
N
LOGISTICS NOTES:
CONSTRUCTION SCHEDULING NOTES:
1. THE PROJECT SHALL BE COMPLETED IN THE CALENDAR DAYS NOTED IN THE CONTRACT.
2. THE GENERAL CONTRACTOR WILL PREPARE A GRAPHIC SCHEDULE FOR FINAL APPROVAL BY THE COR PRIOR TO CONSTRUCTION START.
3. CONTRACTOR MUST COORDINATE SCHEDULE WITH THE COR AND OTHER CONTRACTORS WORKING UNDER SEPARATE CONTRACTS IN ADJACENT SPACES OF THE BUILDING.
4. THE GENERAL CONTRACTOR WILL PREPARE A CONSTRUCTION STAGING AND SAFETY PLAN FOR FINAL APPROVAL BY THE COR PRIOR TO CONSTRUCTION START.
5. CONTRACTOR PARKING LOCATION AND STAGING AREAS ARE NOT SET BE THE VA AND THEREFORE THE CONTRACTOR IS RESPONSIBLE TO DETERMINE WHERE THSE
LOCATIONS WILL BE.
UTILITY LOCATION AND ACCESS NOTES:
CONSTRUCTION DEBRIS NOTES:
1. CONSTRUCTION DEBRIS MUST BE CONTAINED WITHIN THE BOUNDARY AREA AT ALL TIMES.
2. CONSTRUCTION DEBRIS MUST BE MONITORED AND SECURED AT ALL TIMES
3. VA MANDATED RECYCLING FORMS MUST BE KEPT UP TO DATE.
4. DUMPING OF DEMOLITION OR CONSTRUCTION LIQUIDS IS PROHIBITED IN EXISTING PLUMBING FIXTURES UNLESS DIRECTED OTHERWISE BY COR.
5. CONSTRUCTION DEBRIS MUST NOT BE STORED OR STOCK PILED ON THE EXISTING ROOF.
6. THE CONTRACTOR IS RESPONSIBLE FOR THE CONTINUED USE AND MAINTENANCE OF THE ROOF DRAINAGE ASSEMBLIES.
7. CONTRACTOR IS REQUIRED TO USE SERVICE ELEVATOR TO MOVE MANPOWER AND ALL MATERIALS TO AND FROM PROJECT LOCATION.
LOGISTICS KEY NOTES:
BUILDING 1
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
02/28/25
CONTRACT DOCUMENTS ISSUED FOR BIDDING
CREATE GI ANESTHESIA PROCEDURE
ROOM, 6th FLOOR
657-24-119JC
Saint Louis VA Health Care System John Cochran VA Medical Center
915 N Grand Blvd, St. Louis, MO 63106
DEH DAE
FULLY SPRINKLERED
1. CONTRACTOR MUST CONTACT LOCAL UTILITY MARKING SERVICE TO LOCATE AND MARK ALL UNDERGROUND UTILITIES WITHIN WORK AREA PRIOR TO ANY
DEMOLITION, IF APPLICABLE.
2. CONTRACTOR WILL HAVE ACCESS TO (COR) DESIGNATED 110V ELECTRICITY AND WATER WHILE WORKING ON THE EXTERIOR OF THE BUILDING.
3. CONTRACTOR MAY HAVE ACCESS TO 110V ELECTRICITY, WATER, AND BUILDING RESTROOMS WHILE WORKING ON THE INTERIOR OF THE BUILDING. (VERIFY WITH
COR PRIOR TO USING INTERIOR FACILITIES)
4. DESIGNATED RESTROOMS WILL BE AVAILABLE TO PERSONNEL WHO WORK ON THE EXTERIOR, HOWEVER DUE TO SECURITY TO ENTER THE BUILDING, IT IS RECOMMENDED THAT THE CONTRACTOR PROVIDE A PORTABLE RESTROOM. LOCATION TO BE IDENTIFIED BY COR.
5. ANY ADDITIONAL UTILITIES REQUIRED FOR DEMOLITION OR CONSTRUCTION MUST BE PROVIDED BY THE CONTRACTOR.
1. BUILDING ACCESS POINT; DOCK.
2. STORAGE OF MATERIALS, OR CONSTRUCTION WORK IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PHOTO DOCUMENT AND REPORT ANY EXISTING DAMAGE TO COR PRIOR TO START OF CONSTRUCTION. OFF-SITE STORAGE OF BUILDING MATERIALS MUST BE APPROVED BY THE VA COR PRIOR TO REMOVAL.
3. SUGGESTED DUMPSTER LOCATIONS. PRIOR TO START OF ON-SITE MOBILIZATION. THE CONTRACTOR IS REQUIRED TO OBTAIN A CITY OF ST. LOUIS PERMIT FOR PLACEMENT OF
DUMPSTER ON THE STREET.
4. APPROXIMATE LOCATION OF WORK IN BUILDING.
5. APPROXIMATE LOCATION OF CONSTRUCTION TRAILER. VERIFY WITH COR.
6. WASTE WILL HAVE TO BE TAKEN OUT ON A CART. THE FOLLOWING PAGE NOTATES WASTE REMOVAL THROUGH THE LOADING DOCK.
A. SELECTED CONTRACTOR TO OBTAIN REQUIRED SECURITY CLEARANCES AND BADGES WITH THE CONTRACTING OFFICER REPRESENTATIVE (COR) DURING SUBMITTAL PHASE.
B. BUILDING WILL REMAIN OCCUPIED DURING CONSTRUCTION.
C. DEMOLITION AND CONSTRUCTION WORK SHALL NOT INTERFERE WITH OR REDUCE EXISTING BUILDING SECURITY. CONTRACTOR SHALL WORK WITH COR FOR FINAL LOCATIONS
AND TO SCHEDULE FOR BUILDING SECURITY.
D. CONTRACTOR IS TO PROVIDE TEMPORARY PATH OF EMERGENCY EGRESS FOR AREAS UNDER CONSTRUCTION.
E. CONTRACTOR TO PROVIDE A GRAPHIC PLAN OF PROPOSED TEMPORARY EGRESS AND PROTECTION OF STRUCTURES PRIOR TO COMMENCING WORK FOR OWNER AND ARCHITECT APPROVAL. THE EGRESS PATH MUST HAVE PROTECTION FROM WORK ABOVE AND ADJACENT TO THE PATH.
F. CONTRACTOR WORKING HOURS ARE CURRENTLY 5:00PM - 3:00AM MONDAY THRU FRIDAY. ANY CHANGES TO BUILDING HOURS WILL BE PROVIDED BY THE COR.
G. ALL CONSTRUCTION PERSONNEL MUST SIGN-IN EVERY DAY THAT THEY ARE ON SITE - COORDINATE DESIRED PROCEDURE WITH COR.
H. NOISY WORK AND WORK PRODUCING NOXIOUS ODOR SHALL BE SCHEDULED 48 HOURS IN ADVANCE AND COMPLETED OUTSIDE REGULAR BUILDING HOURS OR AS DIRECTED BY THE COR. PROTECT MECHANICAL DUCTS AND AIR INTAKE FROM DUST, DEBRIS AND NOXIOUS ODORS.
I. NO MATERIAL IS TO BE STAGED OR STORED IN THE BUILDING CORRIDORS AND CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL EXISTING PATHS OF EGRESS FROM THE
BUILDING.
J. THE GENERAL CONTRACTOR MAY USE EXISTING STORAGE WITHIN THE BUILDING ONLY AS DIRECTED BY COR.
K. ALL ROOF DRAINS SHOULD BE PROTECTED FROM DEBRIS. CONTRACTOR TO VERIFY CLEAN CONDITION OF DRAINS AT COMPLETION OF THE PROJECT. IT IS RECOMMENDED THAT THE CONTRACTOR DOCUMENT THE EXISTING CONDITION OF THE ROOF DRAINS PRIOR TO START OF WORK.
L. CONTRACTOR MUST BE AVAILABLE AT ALL TIMES FOR TRAFFIC CONTROL - COORDINATION OF CONSTRUCTION, DELIVERIES, PARKING ACCESS, AND OTHER ON SITE ACTIVITIES KEY
TO THE COMPLETION OF THIS PROJECT.
M. CONTRACTOR PARKING TO BE IN PUBLIC LOTS OR AS DESIGNATED BY COR.
N. MATERIALS STORAGE LOCATIONS AS DESIGNATED BY COR.
O. ALL FURNITURE AND EQUIPMENT MOVEMENT AND IF NECESSARY STORAGE OF FURNITURE AND EQUIPMENT DURING THE PROJECT IS THE RESPONSIBILITY OF THE CONTRACTOR.
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text
FH
AutoCAD SHX Text
FH
AutoCAD SHX Text
LOADING DOCK PAD
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
PE-2021014461
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
CONSTRUCTION MATERIALS PATH PLAN - SIXTH FLOOR
SCALE: 1/8" = 1-0"
N
SPECIALTY NOTES FOR SHEETS 1-GJ-002 AND 1-GJ-003:
A. SECURITY
1. CONTRACTOR SHALL NOT LEAVE DOORS PROPPED OPEN.
2. CONTRACTOR SHALL NOT LEAVE TOOLS OR LADDERS UNATTENDED.
3. CONTRACTOR SHALL NOT LEAVE ELECTRICAL OR DATA PANELS EXPOSED.
B. PHOTOGRAPHY
1. NO PHOTOGRAPHY OF VA PREMISES IS ALLOWED WITHOUT WRITTEN PERMISSION OF THE COR. IF PERMISSION IS GRANTED BY THE COR, NO PHOTOGRAPHY IS PERMITTED OF PERSONNEL, PATIENTS, COMPUTER SCREENS, LICENSE PLATES, OR ANY OTHER SENSITIVE MATERIAL AS DETERMINED BY THE
COR.
C. BADGING
1. ALL CONTRACTOR PERSONNEL ARE REQUIRED TO DISPLAY VA BADGE WHEN WORKING ON STATION.
2. TWO-WEEK NOTICE IS REQUIRED FOR BADGING OF CONTRACTOR PERSONNEL REQUIRING A FLASH
PASS/BADGE ABOVE WAIST.
D. KEYS
1. COORDINATE WITH VA COR FOR ACCESS AND ISSUING OF KEYS.
E. JOBSITE PLAN
1. JOBSITE PLAN MUST BE SUBMITTED PRIOR TO COMMENCEMENT OF WORK
a. INCLUDES a.1. ENTRANCES USED a.2. MATERIAL MOVEMENT PLAN a.3. RESTROOMS TO BE USED a.4. LIST OF SUBCONTRACTORS a.5. PERSONNEL ON SITE
F. TRAILER STORAGE
1. CONTRACTORS ARE REQUIRED TO COORDINATE TRAILER STORAGE LOCATION WITH COR.
G. CONTRACTOR SHALL NOTIFY COR OF ANY MATERIAL REMOVED CONTAINING EE# OR MAXIMO NUMBER.
1. CONTRACTOR SHALL NOTIFY COR OF ANY NEW EQUIPMENT AND/OR SPECIFIC REQUIREMENTS FOR EQUIPMENT (I.E. SPECIAL OUTLETS, ADEQUATE BREAKER SIZE, ETC.). (MAKE, MODEL, SERIAL NUMBER)
H. UTILITY SHUTDOWNS
1. MUST BE COORDINATED WITH COR 21 DAYS IN ADVANCE.
I. FIRESTOPPING
1. INSTALL TEMPORARY FIRESTOPPING IN ALL NEW CORE DRILLED PENETRATIONS IN FLOOR AND WALLS.
ENSURE FIRESTOPPING IS MAINTAINED THROUGHOUT
J. FIRE ALARM/SPRINKLER
1. IF FIRE ALARM AND/OR SPRINKLER SYSTEM IS DISABLED DURING CONSTRUCTION, HEAT DETECTION MUST BE PROVIDED. SIEMENS MUST MAKE FINAL TERMINATIONS AND PROGRAM INTO EXISTING FIRE
ALARM SYSTEM.
K. ILSM
1. TEMPORARY FIRE EXTINGUISHERS SHALL BE APPROPRIATELY MOUNTED AND SPACED DURING
CONSTRUCTION FOR HOUSEKEEPING AND SAFETY REQUIREMENTS.
a. TRAVEL DISTANCE FROM ANY POINT OF THE PROTECTED AREA TO THE NEAREST FIRE
EXTINGUISHER SHALL NOT EXCEED 100 FEET.
L. EXIT PATHS MUST BE LITTER/DEBRIS FREE
M. THE CONTRACTOR IS RESPONSIBLE FOR MOVING, STORING AND PROTECTING ALL EXISTING FURNITURE AND EQUIPMENT IN EACH AREA FOR THE DURATION OF THE PROJECT. FURNITURE AND EQUIPMENT DAMAGED BY THE CONTRACTOR WILL BE REPLACED OR RESTORED TO COMPLETE FUNCTIONALITY AND
APPEARANCE BY THE CONTRACTOR AT NO COST TO THE VA.
N. ALL WORK IN CORRIDORS HAVE TO BE REMOVED BEFORE 6:00AM EACH MORNING.
CONSTRUCTION DEBRIS NOTES
UPUP
UPUP
111213
9 8
F
G
E
D
H
I
J
K
N
P
O
Q
R
S
T
L
M
U
C
B
A
OFFICE
B602
TOILET
A650A
BED RM.
A651
LOUNGE
A601
OFFICE
A602
HAC
A603
NURSE MANAGER
A604
MED. PREP.
A605
NURSE STATION
A606
NOUR.
A607
GI PROCEDURE
ROOM
A608
PROCEDURE RM.
A609 PROCEDURE RM.
A610
SUPPORT SPACE
A610A
PROCEDURE RM.
A611PROCEDURE RM.
A612SCOPE CLEANING
A613
CLEAN
A614
SOILED
A615
ANTE
A613A
CLEAN UTILITY
A611A
TOILET
A613B
CORRIDOR
H601
NURSE BREAK
RM.
A616
STORAGE
A617
OFFICE
A618
OFFICE
A619
TOILET
A619A
OFFICE
A620
TOILET
A616A
OFFICE
A621
OFFICE
A622
STORAGE
A623
WORKSTATION
A624
TOILET
A622A
CLOSET
A623D
ELEC
A623C STORAGE
A623B
STAIR 02
S602
CORRIDOR
H602
TOILET
A623A
TOILET
A626A
CLEAN STORAGE
A629
TOILET
A627A
TOILET
A628
OI&T
A629B
OI&T
A629C
OFFICE
A631
OFFICE
A632
OFFICE
A633
OFFICE
A634
OFFICE
B601
BED RM.
A626
OFFICE
B634
OFFICE
B635
CONFERENCE
RM.
A636
LOCKER
A635
STORAGE
H606C
CORRIDOR
H606
LOUNGE
A637
LOCKER
A638
LOBBY
H607
STORAGE
A640
TOILET
A641A
BED RM.
A641
BED RM.
A642
TOILET
A642A
BED RM.
A643
STAIR 05
S605
CORRIDOR
H603
CLEAN
A645
TOILET
A646A
STORAGE
A645A
BED RM.
A646
ELEC
A647
BED RM.
A652
HAC
A653
TOILET
A652A
MEQ. STORAGE
A654
SOILED
A656 CLEAN
A657
ISOLATION
A658
ANTE RM.
A658B
TOILET
A658A
BED RM.
A659
TOILET
A660A
BED RM.
A660
CORRIDOR
H604
BED RM.
A661TOILET
A661A
CORRIDOR
H605
BED RM.
A662
TOILET
A663A
ANTE RM.
A663B
ISOLATION
A663
NURSE STATION
A664
NOUR.
A664A
OFFICE
A666
SUPPLIES
A665
NURSE MANAGER
A668
TOILET
A668B
TOILET
A668A
STORAGE
A669
BREAK RM.
A670
OFFICE
A671
STAIR 01
S601
BED RM.
A650
TOILET
A649A
CORRIDOR
H606A
BED RM.
A627
BED RM.
A649
F.E. CLOSET
H606B
BED RM.
A648
ELEC
A655
CHASE
CH-A-8
CHASE
CH-A-10
CHASE
CH-A-7
CHASE
CH-A-11
CHASE
CH-A-18
CHASE
CH-A-17
CHASE
CH-A-13
CHASE
CH-A-16
CHASE
CH-A-14
CHASE
CH-A-15
F.E. CLOSET
H602A
CHASE
CH-A-12
CHASE
CH-A-6
UTILITY
A629A
CHASE
CH-A-19
ELEV 2
E2
ELEV 6
E6
CHASE
CH-B-1
CHASE
CH-A-20
CHASE
CH-A-5CHASE
CH-A-4
CHASE
CH-A-1
CHASE
CH-A-2
CHASE
CH-A-3
CHASE
CH-A-9
ELEC
A638A
CHASE
CH-A-21
ELEV 5
E5
ELEV 1
E1
ELEV 3
E3
ELEV 4
E4
CHASE
CH-A-22
1. THE CONTRACTOR SHALL INSPECT THE SITE, STUDY EXISTING CONDITIONS, REVIEW DRAWINGS AND SPECIFICATIONS IN ORDER TO BE FAMILIAR W/ COORDINATION OF WORK REQUIRED IN THIS DOCUMENT PACKAGE AND EXISTING CONDITIONS.
2. CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER.
3. CONTRACTOR SHALL TAKE ALL MEASUREMENTS FOR THE WORK AND BE RESPONSIBLE FOR SAME. COORDINATE THE WORK AND SHOP
DRAWINGS WITH ALL OTHER TRADES AFFECTED AND MAKE ANY NECESSARY OFFSETS TO CONCEAL PIPING AND DUCTWORK AND TO CLEAR
EQUIPMENT, STRUCTURAL MEMBERS AND OTHER OBSTRUCTIONS.
4. ALL UTILITIES AND SERVICES SHALL BE KEPT IN CONTINUOUS OPERATION UNLESS WRITTEN PERMISSION IS OTHERWISE GRANTED BY THE OWNER. TEMPORARY ALTERATIONS AND CONNECTIONS REQUIRED BY THIS CONTRACT SHALL BE MADE SO THAT ALL BUILDING SERVICES ARE MAINTAINED WITH MINIMUM INTERRUPTION. SCHEDULE ALL ELECTRICAL/MECHANICAL OUTAGES 21 DAYS IN ADVANCE WITH THE OWNER.
5. PROTECT ALL WORK, MATERIALS AND EQUIPMENT. CAP OR PLUG TEMPORARY OPENINGS. DELIVER ALL WORK TO THE OWNER CLEAN AND IN
GOOD CONDITION.
6. ALL OCCUPIED WORK AREAS, BUILDING CORRIDORS AND EXTERIOR AREAS SHALL BE KEPT CLEAR OF DEBRIS. CUTTING AND PATCHING OF EXISTING WALLS, FLOORS OR CEILINGS REQUIRED BY NEW WORK SHALL BE INCLUDED AS WORK PROVIDED UNDER THIS CONTRACT.
7. CUTTING SHALL BE DONE WITH CARE SO AS NOT TO DAMAGE EXISTING EQUIPMENT, CONNECTIONS, CONTROLS, ETC. DAMAGE CAUSED BY SUCH CUTTING SHALL BE REPLACED OR REPAIRED TO ORIGINAL CONDITION BY CONTRACTOR AT NO COST TO THE OWNER.
8. ALL MATERIALS AND EQUIPMENT SHALL BE NEW, OF THE BEST QUALITY AND FREE FROM DEFECTS.
9. MANUFACTURER AND MODEL NUMBERS SPECIFIED ESTABLISH THE TYPE AND QUALITY REQUIRED AS BASIS OF DESIGN.
10. ALL WORK SHALL COMPLY WITH APPLICABLE REGULATIONS, CODES AND ORDINANCES.
11. THE CONTRACTOR SHALL PERFORM ALL TESTS AS SPECIFIED OR AS NECESSARY TO DEMONSTRATE A COMPLETE AND SATISFACTORY
INSTALLATION.
12. ALL EXPOSED PENETRATIONS MADE THROUGH EXISTING ROOFS, FLOORS, AND WALLS SHALL BE PATCHED WITH LIKE MATERIALS TO MATCH
THE SURROUNDING SURFACES.
13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING MATERIALS RESULTING FROM WORK UNDER THIS CONTRACT AND
SHALL RESTORE SUCH TO ITS ORIGINAL CONDITION.
14. INSTALL THE SPECIFIED FIRE STOPPING (SLEEVES, WRAP, CONDUIT, ETC.) AT RATED CONSTRUCTION.
14.A. FIRE STOP ALL PENETRATIONS WHERE NEW DEVICES/LINES RELOCATING EXISTING DEVICES/LINES PENETRATING FLOORS, CEILINGS AND OTHER RATED BARRIERS.
14.B. FIRE STOP ALL NEWLY CREATED PENETRATIONS WHERE EXISTING DEVICES/LINES PENETRATE FLOOR, CEILINGS AND OTHER
RATED BARRIERS.
15. ALL NEW STUD WALLS AND GYPSUM BOARD SHALL EXTEND TO STRUCTURE UNLESS NOTED OTHERWISE.
16. ALL GYPSUM BOARD SHALL BE TYPE 'X' FIRE CODE GYPSUM BOARD OR AS INDICATED ON DRAWINGS.
17. PROVIDE 16 GA. METAL BACKING PLATES, UNLESS OTHERWISE SHOWN, IN ALL WALLS TO RECEIVE EQUIPMENT, SHELVING AND
ACCESSORIES, DOOR STOPS AND OTHER ITEMS REQUIRING REINFORCEMENT. NO WOOD BLOCKING IS TO BE USED.
18. ALL ITEMS AND DEVICES, SUCH AS COVER PLATES, SWITCH PLATES, CONVENIENCE OUTLETS, DOOR STOPS AND OTHER FINISH HARDWARE, ETC., SHALL BE REMOVED AND REINSTALLED AS PART OF THE REFINISHING OF EXISTING WALLS INDICATED TO REMAIN.
19. THE CONTRACTOR SHALL WORK WITH THE CONDITIONS AS THEY EXIST AT THE SITE. ALL ABOVE CEILING CONDITIONS SHALL BE REVIEWED, AND MODIFICATIONS IDENTIFIED, COORDINATED AND INCORPORATED INTO THE SHOP DRAWING PROCESS. COORDINATE ALL ABOVE CEILING WORK TO ENSURE A COMPLETE AND OPERATIONAL SYSTEM AT NO ADDITIONAL COST TO THE OWNER. COORDINATION SHALL INCLUDE, BUT
NOT BE LIMITED TO THE FOLLOWING:
19.A. OWNER'S EQUIPMENT REQUIREMENTS.
19.B. CEILING SUPPORT SYSTEM.
19.C. MECHANICAL DUCTWORK SYSTEM.
19.D. LIGHTING FIXTURES, ELECTRICAL WIRING AND CONDUIT SYSTEMS.
19.E. PLUMBING AND PIPING SYSTEMS.
19.F. COMMUNICATIONS SYSTEMS.
20. OBTAIN PERMIT FOR AND CONSTRUCT FIRE-RESISTANT ANTE CHAMBER WITH DOOR AND APPROVED HARDWARE TO SEAL OFF CONSTRUCTION AREA FROM CORRIDOR. SEAL ANTE CHAMBER TO EXISTING CONSTRUCTION. PROVIDE WALK-OFF MATS OUTSIDE CORRIDOR AND ROOM SIDES OF CHAMBER. ANTE CHAMBER TO COMPLY WITH REQ'TS. FOR ICRA LEVEL 4 PROTECTION - REVIEW & COORDINATE PERMIT
& CONSTRUCTION REQ'TS W/ COR AND STATION'S INFECTION CONTROL OFFICER.
21. AT THE COMPLETION OF DEMOLITION THE CONTRACTOR SHALL HAVE A SITE MEETING WITH THE VA TO REVIEW AS-BUILT CONDITIONS OF THE
EXISTING STRUCTURE.
22. WHEN ALTERING THE BUILDING, IF STRUCTURAL INTEGRITY APPEARS TO BE IN QUESTION CONTRACTOR SHALL NOTIFY THE VA IMMEDIATELY.
23. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING, STORING, PROTECTING AND REINSTALLATION OF ALL OF THE VA'S EQUIPMENT
AND FURNITURE, TO INCLUDE BOTH WALL MOUNTED ITEMS AND MOVABLE ITEMS FOR THE DURATION OF THE PROJECT. THIS COORDINATION OF OWNER'S (VA) ITEMS IS REQUIRED FOR ALL PHASES OF CONSTRUCTION. FURNITURE AND EQUIPMENT DAMAGED BY THE CONTRACTOR WILL BE REPLACED OR RESTORED TO COMPLETE FUNCTIONALITY AND APPEARANCE BY THE CONTRACTOR AT NO COST TO
THE VA.
24. CONTRACTOR TO USE BASEMENT DOCK EXTERIOR ENTRANCE FOR REMOVAL AND NEW MATERIAL DELIVERY. CONTRACTOR TO PROVIDE
NECESSARY EQUIPMENT TO PROTECT EXISTING FINISHES.
25. WORK THAT REQUIRES ACCESS TO SPACES OUTSIDE DESIGNATED AREA OF WORK SHALL BE COORDINATED WITH THE VA COR. WORK IN THOSE AREAS SHALL TAKE PLACE OUTSIDE REGULAR BUSINESS HOURS AND THE AREAS SHALL BE CLEANED AND RETURNED TO SERVICE AT
THE END OF EACH SHIFT.
26. UPON COMPLETION OF THE PROJECT. ALL AREAS AVAILABLE FOR CONSTRUCTION MATERIALS, VEHICLES, AND TRASH RECEPTACLES MUST
BE RETURNED TO THEIR ORIGINAL CONDITION.
DEMOLITION GENERAL NOTES:
1. MAINTAIN FIRE RATED CONSTRUCTION AT WALL PENETRATIONS. CONSTRUCTION TO CONFORM TO MANUFACTURER'S
FIRE RATED/TEST ASSEMBLIES.
2. FIRE CAULK ALL SLEEVES AND PENETRATIONS AT FIRE WALLS/PARTITIONS AND FLOORS. CONFORM WITH THE TESTED/SUBMITTED FIRE RATED ASSEMBLY. USE RED FIRE CAULK AND LABEL WALL WITH U.L. DESIGN NUMBER AND ASTM.
FIRE RATED WALLS SHOWN ON PLAN.
3. PATCH AND REPAIR ALL EXISTING FIREPROOFING ON EXISTING STRUCTURAL MEMBERS, INCLUDING THAT WHICH IS
UNCOVERED NEEDING REPAIR AND THAT WHICH IS DISTURBED DURING CONSTRUCTION.
4. PATCH AND REPAIR ALL EXISTING FIRE CAULKING AT EXISTING RATED WALLS WHICH IS UNCOVERED NEEDING REPAIR AND THAT WHICH IS DISTURBED DURING CONSTRUCTION. RE-LABEL EXISTING WALL IF NECESSARY.
5. MAINTAIN 2-HR FIRE RATED FLOOR AT PENETRATIONS, EXISTING FLOOR SLAB, AND 2-HR DECK WITH FIREPROOFING.
CONFORM WITH THE TESTED/SUBMITTED FIRE RATED ASSEMBLY.
FIRE PROOFING - FIRE STOPPING GENERAL NOTES
1-GJ-002
CONSTRUCTION MATERIALS
PATH PLANS - SIXTH FLOOR
WORK AREA
SEE 1-HA-001 AND
ARCHITECTURAL SHEETS.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
02/28/25
CONTRACT DOCUMENTS ISSUED FOR BIDDING
CREATE GI ANESTHESIA PROCEDURE
ROOM, 6th FLOOR
657-24-119JC
Saint Louis VA Health Care System John Cochran VA Medical Center
915 N Grand Blvd, St. Louis, MO 63106
DEH DAE
FULLY SPRINKLERED
USE THIS ELEVATOR DOWN TO LEVEL 00 FOR
REMOVAL OF DETRITUS AND FOR BRINGING
IN NEW MATERIALS UP TO WORK SITE. SEE
SHEET GJ-003 FOR CONTINUATION.
ROUTE OF COVERED TRASH
CONTAINER TRAVEL
DO NOT USE THIS
ELEVATOR BANK
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
PE-2021014461
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
SPECIALTY NOTES:
CONSTRUCTION MATERIALS PATH PLAN - BASEMENT FLOOR
SCALE: 1/8" = 1-0"
N
A. SEE SPECIALTY NOTES ON SHEET 1-GJ-002.
SP
F
GG
E
D
H
I
J
K
N
P
O
Q
R
S
T
L
M
G-A
H-A
UU
CC
BB
AA
1.8
1.8
2.5
2.5
2.9
2.9
G.9
1-GJ-003
CONSTRUCTION MATERIALS
PATH PLANS - FIRST FLOOR
TO DUMPSTER. SEE
SHEET 1-GJ-001.
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
02/28/25
CONTRACT DOCUMENTS ISSUED FOR BIDDING
CREATE GI ANESTHESIA PROCEDURE
ROOM, 6th FLOOR
657-24-119JC
Saint Louis VA Health Care System John Cochran VA Medical Center
915 N Grand Blvd, St. Louis, MO 63106
DEH DAE
FULLY SPRINKLERED
ROUTE OF COVERED TRASH
CONTAINER TRAVEL
USE THIS ELEVATOR UP TO LEVEL 06 FOR
REMOVAL OF DETRITUS AND FOR BRINGING
IN NEW MATERIALS UP TO WORK SITE. SEE
SHEET GJ-002 FOR CONTINUATION.
DO NOT USE THIS
ELEVATOR BANK
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
PE-2021014461
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
5 4 3
H
G
F
E
OFFICE
A509
CORRIDOR
H501
TOILET
A508A
OFFICE
A508
TOILET
A507A
OFFICE
A507
COPY
A504
HAC
A503
TOILET
A506A
NOUR.
A505
OFFICE
A506
OFFICE
A517
OFFICE
A516
OFFICE
A515
OFFICE
A514
TOILET
A516A
TOILET
A514A
STRG
A521
SOILED
A519
ELEC
A520
TOILET
A517A
STORAGE
A518
CORRIDOR
H502
CHASE
CH-A-4
CHASE
CH-A-13
CHASE
CH-A-14
MED. PREP.
A605
NURSE STATION
A606
NOUR.
A607
GI PROCEDURE
ROOM
A608
PROCEDURE RM.
A609
SUPPORT SPACE
A610A
PROCEDURE RM.
A612SCOPE CLEANING
A613
CLEAN
A614
SOILED
A615
ANTE
A613A
CLEAN UTILITY
A611A
TOILET
A613B
CORRIDOR
H601
NURSE BREAK
RM.
A616
STAIR 02
S602
CORRIDOR
H602
TOILET
A626A
A629
TOILET
A627A
TOILET
A628
BED RM.
A626
BED RM.
A627
CHASE
CH-A-8
CHASE
CH-A-10
CHASE
CH-A-7
CHASE
CH-A-11
CHASE
CH-A-18
F.E. CLOSET
H602A
CHASE
CH-A-12
CHASE
CH-A-6
CHASE
CH-A-9
AREA OF WORK
1-HA-001
HAZARDOUS MATERIALS PLANS
1. THE ABATEMENT, DEMOLITION AND STABILIZATION WILL BE CONDUCTED INSIDE NEGATIVE PRESSURE GROSS REMOVAL CONTAINMENTS AND ALL WORK SHALL BE CONDUCTED IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL REGULATIONS AND THE CONTRACT SPECIFICATIONS.
2. ABATEMENT WORK WILL BE PERFORMED AND PHASED IN ACCORDANCE WITH THE PROJECT SCHEDULE AND
WILL INCLUDE WORK DURING ALL SHIFTS AND WEEKENDS AS NEEDED.
3. WORK SCHEDULES AND LIMITS OF ABATEMENT SHALL BE COORDINATED WITH THE VA COR AND VPIH FOR
APPROVALS, UNLESS OTHERWISE INDICATED ON THE KEYNOTES.
4. THE ABATEMENT CONTRACTOR SHALL SUBMIT A DETAILED WORK PLAN AND ABATEMENT SCHEDULE WITH THE REQUIRED SUBMITTALS. ANY CHANGES TO THE PROCEDURES, CONTAINMENT LIMITS AND PHASING SHALL BE
SUBMITTED TO THE VA COR AND VPIH FOR APPROVALS.
5. THE LIMITS OF REMOVAL AND EXTENT OF THE CONTAINMENTS SHALL BE VERIFIED WITH THE VA COR AND
VPIH. FOR CLARITY, THE DRAWINGS ONLY SHOW REPRESENTATIVE LOCATIONS.
6. ALL LOADOUT PROCEDURES SHALL BE COORDINATED WITH THE VA COR AND VPIH.
7. ALL POLYETHYLENE SHEETING USED FOR THE ABATEMENT PROJECT SHALL BE FIRE RETARDANT.
8. THE LOCATIONS OF ABATEMENT DECONTAMINATION UNITS AND WASTE DISPOSAL CONTAINERS SHALL BE FIELD
VERIFIED WITH THE VA COR AND VPIH.
9. SEE DEMOLITION ICRA PLAN FOR TEMPORARY PARTITION AND INFECTION CONTROL DETAILS.
10. ALL PERIMETER AIR MONITORING AND CLEARANCE SAMPLING WILL BE CONDUCTED BY THE VPIH.
11. TEMPORARY LIGHTING OF SUFFICIENT LUMINOSITY SHALL BE PROVIDED FOR AND USED BY THE ABATEMENT
CONTRACTOR DURING THE ABATEMENT PROCESS.
12. FIBERGLASS PIPE INSULATION WILL BE PRESENT IN ABATEMENT CONTAINMENTS. PROPERLY WRAP AND
PROTECT AS REQUIRED.
ASBESTOS GENERAL NOTES
ASBESTOS AND LEAD BASED PAINT
1. CONTACT THE COR TO OBTAIN MOST-CURRENT COPIES OF ASBESTOS AND LEAD BASED PAINT
REPORTS. REFER TO DIVISION 2 IN THE SPECIFICATIONS FOR ASBESTOS ABATEMENT AND LEAD
BASED PAINT ENCAPSULATION OR REMOVAL SPECIFICATIONS.
2. SCOPE OF ASBESTOS CONTAINING MATERIALS (ACM) AND LEAD BASED PAINT (LBP) DISCLOSED IN
THE REPORT HAS BEEN NOTED ON THIS PLAN. CONTRACTORS' PERSONNEL INVOLVED WITH
WORK IN AREAS FOUND TO HAVE ASBESTOS CONTAINING (ACMs) ARE TO BE PROVIDE WITH
APPROPRIATE OSHA ASBESTOS TRAINING PRIOR TO START OF WORK.
3. ALL WORK IN CORRIDORS HAVE TO BE REMOVED BEFORE 6:00AM EACH MORNING, UNLESS PRIOR
APPROVAL FROM COR AND VA SAFETY.
PLAN NOTES
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
02/28/25
CONTRACT DOCUMENTS ISSUED FOR BIDDING
CREATE GI ANESTHESIA PROCEDURE
ROOM, 6th FLOOR
657-24-119JC
Saint Louis VA Health Care System John Cochran VA Medical Center
915 N Grand Blvd, St. Louis, MO 63106
DEH DAE
FULLY SPRINKLERED
A-2 A-3 A-2 A-3 A-2 A-3
AREA OF WORK
A-1
A-1
1. DOOR COVERING TO MEET/EXCEED JOHN COCHRAN ICRA STANDARDS. VERIFY WITH COR.
2. DOOR WITH WALKOFF MAT.
3. CONSTRUCTION BARRIER LIMITS.
4. CONTAINMENT BARRIER; MAINTAIN A MINIMUM OF 44" FREE AREA THROUGH CORRIDOR.
5. PLACE DECONTAMINATION UNIT IN APPROPRIATE LOCATION IN WORK AREA.
AutoCAD SHX Text %%U5th FLOOR 03 PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text
PE-2021014461
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text M
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text
HANNAH ROSE KIGER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text %%U6th FLOOR 03 PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
4" RUBBER COVE
WITH 16 GA. METAL
STUDS AT 16" O.C.
BOARD ON ONE SIDE,
WITH 5/8" GYPSUM
AS SCHEDULED
ACOUSTICAL CEILING
2' X 4' SUSPENDED
WALL CONST. TYPES (DETAILS)
TYPE A
BASE @ BOTH SIDES
4" RUBBER COVE
3 5/8" 16 GA. METAL
STUDS AT 16" O.C.
BOARD EACH SIDE.
WITH 5/8" GYPSUM
W A
LL
H
EI
G H T
V
ER
IE
S
TYPE B
C
EI
LI
N G
H
EI
G H T
'-0
ON FLOOR PLAN.
FI
EL
D V
ER
IF
Y
C
EI
LI
N G
H
EI
G H T
'-0
4 7/8"4 7/8"
W A
LL
H
EI
G H T
V
ER
IE
S
FI
EL
D V
ER
IF
Y
TO MATCH EXISTING AREA TO MATCH EXISTING AREA
ROOF METAL DECKING
BASE @ BOTH SIDES
AS SCHEDULED
ACOUSTICAL CEILING
2' X 4' SUSPENDED
ON FLOOR PLAN.
3 5/8" INSULATED WALL
TO CREATE NEGATIVE AIR
PRESSURE INSIDE WORK ZONE.
WITH FLAME-RETARDANT
PLASTIC SHEETING UNDER
WALL TO EXTEND TO
ROOF METAL DECKING
OFFICE AREAS CARDIOLOGY CCU ANY AREA CARING FOR
ECHOCARDIOGRAPHY
ENDOSCOPY
NUCLEAR MEDICINE
PHYSICAL THERAPY
RADIOLOGY/MRI
RESPIRATORY THERAPY
EMERGENCY ROOM
LABOR & DELIVERY
LABORATORY (SPECIMEN)
NEWBORN NURSERY
OUTPATIENT SURGERY
PEDIATRICS
IMMUNOCOMPROMISED PATIENTS
BURN UNIT
CARDIAC CATH LAB
CENTRAL STERILE SUPPLY
INTENSIVE CARE UNITS
MEDICAL UNIT
PHARMACY
POST ANESTHESIA CARE UNIT
SURGICAL UNITS
NEGATIVE PRESSURE ISOLATION ROOMS
ONCOLOGY
OPERATING ROOMS INCLUDING
C-SECTION ROOMS
INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK
LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
1. ISOLATE H.V.A.C. SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT
CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS IE. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL
AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH
PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR
VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS IF INDICATED.
4. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY.
5. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM
7. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL.
8. ROOM AND/OR SHALL BE THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL
SERVICES DEPARTMENT.
2. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
5. VACUUM WORK AREA WITH HEPA FILTERED VACUUM.
6. WET MOP AREA WITH DISINFECTANT.
SO THEY CAN BE VACUUMED USING HEPA VACUUM CLEANER BEFORE LEAVING WORK
SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH
TIME THEY LEAVE THE WORK SITE.
6. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS.
SHOE COVERS MUST BE CHANGED EACH TIME THE WORKER EXITS THE WORK AREA.
SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH
TIME THEY LEAVE THE WORK SITE.
3. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
7. REMOVE ISOLATION OF H.V.A.C. SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
4. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
1. OBTAIN APPROVAL BY MCOT TEAM TO REMOVE BARRIERS.
TYPE B
TYPE A
CROSS-SECTION 'A-A' MOBILE CONTAINMENT CART
CLASS IV
TYPE IV ICRA CONSTRUCTION DETAILS
TYPICAL IDEAL CONSTRUCTION LAYOUT CLASS IV
ILSMICRA
MANOMETER
READING FORM
PROJECT
CONTACT
SHEET
POSTED ON THE CONTAINMENT DOOR IN CLEAR
PLASTIC SLEEVES
1-HA-002
TYPE IV ICRA CONSTRUCTION DETAILS
CONSULTANTS: ARCHITECT/ENGINEERS:
Revisions: Date:
Drawing Title
VA Health Care System Approval:
Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
Drawing # of
Veterans Health
Administration www.daengineering.com www.daengineering.com voice (317) 464-9090 2707 Rand Road Indianapolis, Indiana 46241 fax (317) 464-9393
Mechanical, Electrical, and Energy Engineering
DESIGN-AIRE ENGINEERING, INC.
02/28/25
CONTRACT DOCUMENTS ISSUED FOR BIDDING
CREATE GI ANESTHESIA PROCEDURE
ROOM, 6th FLOOR
657-24-119JC
Saint Louis VA Health Care System John Cochran VA Medical Center
915 N Grand Blvd, St. Louis, MO 63106
DEH DAE
FULLY SPRINKLERED
AutoCAD SHX Text
%%UGENERAL NOTES:
AutoCAD SHX Text
2. ALL APPLICABLE FORMS TO BE COMPLETED AND APPROVED PRIOR TO STARTING WORK.
AutoCAD SHX Text
3. PERMITS TO INCLUDE:
AutoCAD SHX Text
ICRA, ILSM, ABOVE CEILING, FIRE SPRINKLER SYSTEM, MEDICAL GASES,
AutoCAD SHX Text
UTILITY SHUT-DOWN, FIRE/SMOKE WALL, FIRE ALARM SYSTEM.
AutoCAD SHX Text
4. THE CONSTRUCTION AREA MUST MAINTAIN A NEGATIVE PRESSURE VENTILATION.
AutoCAD SHX Text NEGATIVE AIR UNIT TO BE MAINTAINED WITH FILTER(S) REPLACEMENT PER SPECIFICATIONS.
AutoCAD SHX Text
1. ALL PERSONNEL ENTERING THE CONSTRUCTION SITE AREA MUST WEAR A HARD HAT
AutoCAD SHX Text
AND SAFETY GLASSES ALONG WITH ANY OTHER PPE REQUIRED IN THAT AREA.
AutoCAD SHX Text
CLEAN ALL EXTERIOR SURFACES OF CARTS AND TOOLS AT THE END OF EACH SHIFT.
AutoCAD SHX Text
(WEEKLY REPLACEMENT OF PRE-FILTER OR AS NECESSARY. HEPA FILTER REPLACED MONTHLY.
AutoCAD SHX Text
NEGATIVE PRESSURE MACHINES MUST BE ON AND OPERATIONAL 24/7.
AutoCAD SHX Text
MONITOR NEGATIVE PRESSURE AND POST LOG AT THE END OF EACH SHIFT.
AutoCAD SHX Text
5. CONSTRUCTION CLASS WILL BE DETERMINED BY THE CONSTRUCTION SAFETY COMITY.
AutoCAD SHX Text
6. DURING CONSTRUCTION BE CERTAIN THAT:
AutoCAD SHX Text
BARRIERS ARE INTACT AND MAINTAINED.
AutoCAD SHX Text
PARTICAL COUNT METER IS AVAILABLE.
AutoCAD SHX Text
NEGATIVE INDICATOR IS AVAILABLE.
AutoCAD SHX Text
ICRA REQUIREMENTS ARE INTACT AND
AutoCAD SHX Text
VERIFY ARE BEING MAINTAINED.
AutoCAD SHX Text
LOW RISK
AutoCAD SHX Text
PATIENT RISK GROUPS
AutoCAD SHX Text
MEDIUM RISK
AutoCAD SHX Text
HIGH RISK
AutoCAD SHX Text
HIGHEST RISK
AutoCAD SHX Text
LOW RISK GROUP
AutoCAD SHX Text
CONSTRUCTION PROJECT TYPE
AutoCAD SHX Text
MEDIUM RISK GROUP
AutoCAD SHX Text
HIGH RISK GROUP
AutoCAD SHX Text
HIGHEST RISK GROUP
AutoCAD SHX Text
RISK RELATED GROUP
AutoCAD SHX Text
TYPE A
AutoCAD SHX Text
TYPE B
AutoCAD SHX Text
TYPE C
AutoCAD SHX Text
TYPE D
AutoCAD SHX Text I
AutoCAD SHX Text
II
AutoCAD SHX Text
II
AutoCAD SHX Text
III/IV
AutoCAD SHX Text
II
AutoCAD SHX Text
II
AutoCAD SHX Text
III/IV
AutoCAD SHX Text
III/IV
AutoCAD SHX Text
III
AutoCAD SHX Text
III/IV
AutoCAD SHX Text
IV
AutoCAD SHX Text
IV
AutoCAD SHX Text
IV
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text
II
AutoCAD SHX Text
CONSTRUCTION PROJECT BY PATIENT RISK
AutoCAD SHX Text
IC MATRIX - CLASS OF PRECAUTIONS:
AutoCAD SHX Text
%%UNOTE:
AutoCAD SHX Text
TYPE A
AutoCAD SHX Text
TYPE B
AutoCAD SHX Text
TYPE C
AutoCAD SHX Text
TYPE D
AutoCAD SHX Text
MATRIX OF PRECAUTIONS FOR
AutoCAD SHX Text
CONSTRUCTION & RENOVATION
AutoCAD SHX Text
NFECTION
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text
ONTROL
AutoCAD SHX Text
ISK
AutoCAD SHX Text
SSESSMENT
AutoCAD SHX Text (I
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text A)
AutoCAD SHX Text
CLASS 1V
AutoCAD SHX Text
%%UPRIOR TO ANY CONSTRUCTION
AutoCAD SHX Text
%%UPOST CONSTRUCTION
AutoCAD SHX Text
TEMP. ANTE ROOM
AutoCAD SHX Text
HARD BARRIER
AutoCAD SHX Text
EITHER KEEP RUNNING
AutoCAD SHX Text
COVER ALL RETURNS
AutoCAD SHX Text
HEPA NEGATIVE AIR UNIT
AutoCAD SHX Text
TAPE ALL SERVICES
AutoCAD SHX Text
ABC TYPE FIRE EXTINGUISHER ON
AutoCAD SHX Text
FIRE RETARDANT TREATED PLYWOOD
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text V
AutoCAD SHX Text
WEEKLY CHANGED
AutoCAD SHX Text
(OR MORE AS NEEDED)
AutoCAD SHX Text
MONTHLY CHANGED
AutoCAD SHX Text
HEPA FILTER
AutoCAD SHX Text
PRE-FILTER
AutoCAD SHX Text
SUPPLY DUCTS
AutoCAD SHX Text
OR COVER WITH FIRE
AutoCAD SHX Text
AT THE GRATE/DIFFUSERS
AutoCAD SHX Text
TO PROTECT AGAINST
AutoCAD SHX Text
PORTABLE FLOOR BRACKET
AutoCAD SHX Text
CONTAMINATION
AutoCAD SHX Text
(REFER TO ELEVATION)
AutoCAD SHX Text
FLEX DUCT
AutoCAD SHX Text
EXISTING WINDOW FRAME
AutoCAD SHX Text
FIRE RATED PLYWOOD
AutoCAD SHX Text
(TEMP. REMOVE
AutoCAD SHX Text
HEPA NEGATIVE AIR UNIT
AutoCAD SHX Text
EXISTING FIRE
AutoCAD SHX Text
SPRINKLER SYSTEM
AutoCAD SHX Text
EXISTING CONCRETE SLAB FLOORING
AutoCAD SHX Text
FIRE/U.L. RATED PLASTIC
AutoCAD SHX Text
TO PREVENT DUST
AutoCAD SHX Text
GLASS PANEL)
AutoCAD SHX Text E
AutoCAD SHX Text
OPTIONAL EXHAUST DUCTS
AutoCAD SHX Text
(COVER THE GRATES
AutoCAD SHX Text
AND THE DIFFUSERS)
AutoCAD SHX Text
EXISTING WALL
AutoCAD SHX Text
EXISTING WALL
AutoCAD SHX Text
INDICATOR MUST BE AT -0.01 OR MORE NEGATIVE
AutoCAD SHX Text
(VERIFY DAILY), IF NOT VERIFY ALL OPENING
AutoCAD SHX Text
SUCH AS DOORS ARE CLOSED AND/OR CHANGE
AutoCAD SHX Text
OUT NEGATIVE AIR PRE-FILTER.
AutoCAD SHX Text
(LOCKED AT ALL TIMES)
AutoCAD SHX Text
BLUE CORE LOCKSET
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
OUTSIDE OF BUILDING
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
AutoCAD SHX Text
FINISHED FLOORING TO BE KEPT CLEAN.
AutoCAD SHX Text
FLOORS NOT BEING REPLACED TO BE
AutoCAD SHX Text
WITH FIRE RATED PLASTIC
AutoCAD SHX Text
SHEETING AND SECURE
AutoCAD SHX Text
WITH DUCT TAPE.
AutoCAD SHX Text
RATED PLASTIC SHEETING
AutoCAD SHX Text
AND SECURE WITH DUCT
AutoCAD SHX Text
TAPE TO KEEP DUST OUT.
AutoCAD SHX Text
(ILSM MAY REQUIRE MORE
AutoCAD SHX Text
THAN ONE OR WALL MOUNTED).
AutoCAD SHX Text
PROVIDE STICKY MATS
AutoCAD SHX Text
(CHANGED END OF SHIFT
AutoCAD SHX Text
OR MORE IF NECESSARY
AutoCAD SHX Text
TO MAINTAIN CLEANLINESS).
AutoCAD SHX Text
(TYPICAL REGULATOR INSTALLATION).
AutoCAD SHX Text
PRIOR TO CONSTRUCTION).
AutoCAD SHX Text
FLEX DUCT
AutoCAD SHX Text
CART WITH CANVAS/
AutoCAD SHX Text
1-1/4" SQUARE
AutoCAD SHX Text
TUBE FRAME AND
AutoCAD SHX Text
ZIPPER SIDE ENTRY
AutoCAD SHX Text
PLASTIC WINDOW
AutoCAD SHX Text
HEPA NEGATIVE AIR UNIT
AutoCAD SHX Text
MOBILE CONTAINMENT
AutoCAD SHX Text
FLEX DUCT
AutoCAD SHX Text
NEED INSPECTION TAG AND
AutoCAD SHX Text
MONTHLY INSPECTION).
AutoCAD SHX Text
(INITIALS/DATED).
AutoCAD SHX Text
INFILTRATION (INSTALL
AutoCAD SHX Text
(REFER TO
AutoCAD SHX Text
ELEV. DETAIL)
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
PROTECTED OR COVERED WITH ROSEN
AutoCAD SHX Text
PAPER/FIRE RATED PLYWOOD.
AutoCAD SHX Text
THE REQUIRED INFECTION CONTROL RISK ASSESSMENT FORMS
AutoCAD SHX Text
MUST BE COMPLETED AND POSTED IN THE PROPER AREA.
AutoCAD SHX Text
%%UINTERIM LIFE SAFETY MEASURES:
AutoCAD SHX Text
%%UINFECTION CONTROL RISK ASSESSMENT:
AutoCAD SHX Text
THE REQUIRED INTERIM LIFE SAFETY MEASURES FORMS
AutoCAD SHX Text
MUST BE COMPLETED AND POSTED IN THE PROPER AREA.
AutoCAD SHX Text
DAILY FIRE WATCH INSPECTIONS MUST BE PROVIDED DAILY BY THE
AutoCAD SHX Text
PROJECT ENGINEER OR PERSON(S) ASSIGNED BY THE PROJECT
AutoCAD SHX Text
ENGINEER. THIS MUST BE LOGGED IN WITH DOCUMENTATION.
AutoCAD SHX Text
PICRA:
AutoCAD SHX Text
%%UUTILITIES SHUT-DOWNS:
AutoCAD SHX Text
THE AREA. PROJECT ENGINEER TO HAVE DOCUMENTED PROOF OF
AutoCAD SHX Text
THE PROJECT ENGINEER SHALL NOTIFY THE PROPER SHOP
AutoCAD SHX Text
PERSONNEL AND STAFF MEMBERS WITH A MIN. OF 21 DAYS
AutoCAD SHX Text
IN ADVANCE FOR ANY UTILITIES SHUT-DOWN(S) THAT WILL EFFECT
AutoCAD SHX Text
ICRA
AutoCAD SHX Text
ILSM
AutoCAD SHX Text
REQUIREMENT. (NOT APPLICABLE ON SOME PROJECTS).
AutoCAD SHX Text
TO BE PROVIDED WHEN APPLICABLE WITH PROJECT
AutoCAD SHX Text
THIS ACTION.
AutoCAD SHX Text
LOGGED IN WITH DOCUMENTATION.
AutoCAD SHX Text
INTERIM LIFE SAFETY MEASURES FORM WILL BE SIGNED BY
AutoCAD SHX Text
THE COR AND SAFETY REPRESENTATIVE.
AutoCAD SHX Text
SITE TO BE INSPECTED ON A DAILY BASES AND MUST BE
AutoCAD SHX Text
SITE AREA PLASTIC WALL AND/OR ANTE ROOM ENCLOSURE WILL
AutoCAD SHX Text
BE INSPECTED BY INFECTION CONTROL PREVENTION COORDINATOR,
AutoCAD SHX Text
SAFETY REPRESENTATIVE AND CONTRACT OFFICER REPRESENTATIVE
AutoCAD SHX Text
(COR) FOR APPROVAL PRIOR TO PROJECT START/RELEASE DATE.
AutoCAD SHX Text
REMOVAL OF PLASTIC WALLS AND ENCLOSURES TO BE REMOVED
AutoCAD SHX Text
UPON THEIR APPROVAL.
AutoCAD SHX Text Work can be completed in a single shift, not to exceed 10 hours. Patients and/or employees may be in the area depending on the activity & location, excluding patient care rooms. Work that does not create dust or debris. Removal of ceiling tile or access to mechanical or electrical chase for visual inspection limited to 1 tile per 50 square feet with limited exposure time (not to exceed an hour for each tile) within the shift. Minor interior updates (e.g., replacing up to 2 floor or ceiling tiles, carpentry work to include hanging signage, and painting without sanding) that do not create dust or debris. Limited building system maintenance such as plumbing on potable systems limited to faucet replacement etc. and electrical work such as replacement of bulbs, receptacles, or switches.
AutoCAD SHX Text
INSPECTION AND/OR FACILITY UPKEEP GENERALLY DEFINED AS FOLLOWS:
AutoCAD SHX Text Prolonged inspection and work that may take longer than a single shift but not exceeding a week. Patients and employees are not to be in the area until activity is completed. Work that creates minimal dust and debris. Interior finish or surface repairs, updates, or modifications such as repair of firewalls and barriers, and new flooring that produces minimal dust and debris. Controlled sanding activities (e.g., wet or HEPA vacuum dry sanding) that produce minimal dust and debris. Access to chase spaces using doors and hatches (not cutting). Plumbing work such as installation or replacement of a single fixture or piping for a single fixture. Any work on sanitary plumbing including snaking of drains. Electrical work such as installation of cabling/wiring/conduit for a single device, installation of new device such as a light fixture that produces minimal dust and debris. Air Handler and/or fan shutdown/startup and HVAC work such as replacement of a single diffuser, single terminal unit or a single device that produces minimal dust and debris.
AutoCAD SHX Text
GENERAL MAINTENANCE AND REPAIR WORK GENERALLY DEFINED AS FOLLOWS:
AutoCAD SHX Text
FIRE/U.L. RATED PLASTIC TO PREVENT DUST (INSTALL PRIOR TO CONSTRUCTION).
AutoCAD SHX Text SMALL-SCALE CONSTRUCTION, RENOVATION, OR MAINTENANCE GENERALLY DEFINED AS FOLLOWS:
AutoCAD SHX Text Patients and employees are not to be in the area until activity is completed. Demolition/removal of preexisting floor covering, casework, lay-in ceiling, or other architectural elements.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .