TP09 Combined DWG 657A4-19-103.pdf

PDF 16 MB Posted

Attached to
Z2DA--657A4-19-103, COVID-19 Medical Gas Correction (VA-20-00086340)
Solicitation number
36C25520R0117
Issued by

View the file

Other files

File Type Posted
TP09 657A4-19-103 Combined Specs.pdf PDF
36C25520R0117_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

PROJECT SITE MAP PROJECT LOCATION MAP

PROJECT IMAGE

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

G-001

COVER

1 2

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901

VA PROJECT #:

657A4-19-103

APOGEE PROJECT #: 19-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

RECERTIFY AND EVALUATE FOR CORRECTION OF MEDICAL GAS,

MEDICAL VACUUM, DENTAL VACUUM, AND OXYGEN SYSTEMS

DRAWING LIST

No. Description Dwg of Dwg

GENERAL

G-001 COVER 1 2

G-100 ICRA DETAILS 2 2

ARCHITECTURAL

A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS, AND NOTES 1 7

A-100 GROUND FLOOR PLAN - OVERALL 2 7

A-101 FIRST FLOOR PLAN- OVERALL 3 7

A-102 SECOND FLOOR PLAN - OVERALL 4 7

A-103 THIRD FLOOR PLAN - OVERALL 5 7

A-104 FOURTH FLOOR PLAN - OVERALL 6 7

A-105 FIFTH FLOOR PLAN - OVERALL 7 7

PLUMBING

P-001 PLUMBING GENERAL INFORMATION 1 27

PD101 GROUND FLOOR MEDICAL GAS DEMOLITION PLAN - AREA A, B & F 2 27

PD102 GROUND FLOOR MEDICAL GAS DEMOLITION PLAN - AREA C, D & E 3 27

PD103 FIRST FLOOR MEDICAL GAS DEMOLITION PLAN - AREA A, B & F 4 27

PD104 FIRST FLOOR MEDICAL GAS DEMOLITION PLAN - AREA C, D & E 5 27

PD105 SECOND FLOOR MEDICAL GAS DEMOLITION PLAN - AREA A, B & F 6 27

PD106 SECOND FLOOR MEDICAL GAS DEMOLITION PLAN - AREA C, D & E 7 27

PD107 THIRD FLOOR MEDICAL GAS DEMOLITION PLAN - AREA A, B & F 8 27

PD108 THIRD FLOOR MEDICAL GAS DEMOLITION PLAN - AREA C, D & E 9 27

PD109 FOURTH FLOOR MEDICAL GAS DEMOLITION PLAN - OVERALL 10 27

PD110 FIFTH FLOOR AND PENTHOUSE - MEDICAL GAS DEMOLITION PLAN - OVERALL 11 27

PG101 GROUND FLOOR MEDICAL GAS PLAN - AREA A, B & F 12 27

PG102 GROUND FLOOR MEDICAL GAS PLAN - AREA C, D & E 13 27

PG103 FIRST FLOOR MEDICAL GAS PLAN - AREA A, B & F 14 27

PG104 FIRST FLOOR MEDICAL GAS PLAN - AREA C, D & E 15 27

PG105 SECOND FLOOR MEDICAL GAS PLAN - AREA A, B & F 16 27

PG106 THIRD FLOOR MEDICAL GAS PLAN - AREA A, B & F 17 27

PG107 THIRD FLOOR MEDICAL GAS PLAN - AREA C, D & E 18 27

PG108 FOURTH FLOOR MEDICAL GAS PLAN - OVERALL 19 27

PG109 FIFTH FLOOR AND PENTHOUSE - MEDICAL GAS PLAN - OVERALL 20 27

P-501 MEDICAL GAS DETAILS 21 27

P-601 EXISTING TYPICAL HEADWALL/OUTLET TYPES 22 27

P-602 EXISTING TYPICAL HEADWALL/OUTLET TYPES 23 27

P-603 HEADWALL/OUTLET SCHEDULE 24 27

P-604 NEW HEADWALL/OUTLET TYPES FOR REFERENCE 25 27

P-901 EXISTING MEDICAL GAS RISER DIAGRAM 26 27

P-902 NEW MEDICAL GAS RISER DIAGRAM 27 27

ELECTRICAL

E-001 ELECTRICAL GENERAL NOTES, SYMBOL LEGENDS, AND ABBREVIATIONS 1 11

EP101 GROUND FLOOR ELECTRICAL PLAN - AREAS A, B, & F 2 11

EP102 CRAWLSPACE AND GROUND FLOOR ELECTRICAL PLAN - AREAS C, D, E, & G 3 11

EP103 FIRST FLOOR ELECTRICAL PLAN - AREAS A, B, & F 4 11

EP104 FIRST FLOOR ELECTRICAL PLAN - AREAS C, D, & E 5 11

EP105 SECOND FLOOR ELECTRICAL PLAN - AREAS A, B, & F 6 11

EP106 SECOND FLOOR ELECTRICAL PLAN - AREAS C, D, & E 7 11

EP107 THIRD FLOOR ELECTRICAL PLAN - AREAS A, B, & F 8 11

EP108 THIRD FLOOR ELECTRICAL PLAN - AREAS C, D, & E 9 11

EP109 FOURTH FLOOR ELECTRICAL PLAN 10 11

EP110 FIFTH AND PENTHOUSE ELECTRICAL PLAN 11 11

24514

LICENSED

ARCHITECT

DocuSign Envelope ID: 06261F59-CC88-4901-B576-B783598B5151

7/30/2020

HEATED DETECTOR CUT-OFF

BASIS OF DESIGN: HEPA

NEGATIVE AIR UNIT INTEGRAL

WITH EDGEGUARD BARRIER

SYSTEM.

FIRE RATED PLYWOOD (TEMP.

REMOVE GLASS PANEL)

EXISTING WINDOW FRAME

ICRA BARRIER ICRA BARRIER

ADJUSTS FROM

7'-8" TO 10'-0" A.F.F

EXISTING CEILING

EXISTING CONCRETE SLAB FLOORING

FINISHED FLOORING TO BE

KEPT CLEAN. FLOORS NOT

BEING REPLACED MUST BE

PROTECTED. COVER WITH

ROSIN PAPER/ FIRE RATED

PLYWOOD.

OUTSIDE OF BUILDING

MONTHLY CHANGED HEPA

FILTER

HEPA NEGATIVE

AIR UNIT

WEEKLY CHANGED (OR MORE AS

NEEDED) PRE FILTER

FIRE RATED PLYWOOD

F L E

X D

U C

T

SUPPLY DUCTS EITHER KEEP

RUNNING OR COVER WHEN

RUNNING TO KEEP DUST OUT.

TAPE ALL SERVICES

TO PROTECT AGAINST

CONTAMINATION

A

O

V

FIRE EXTINGUISHER ON PORTABLE

FLOOR BRACKET (ILSM MAY REQUIRE

MORE THAN ONE)

SUSPENDED PLASTIC ZIPPER

WALL CURTAIN BARRIER

INDICATOR SHALL BE AT -0.01 OR

GREATER (VERIFY DAILY). IF NOT

VERIFY ALL OPENINGS SUCH AS DOOR

ARE CLOSED AND/OR CHANGE OUT

NEGATIVE AIR PRE-FILTER

PROVIDE STICKY MATS

(CHANGED END OF SHIFT

OR MORE IF NECESSARY

TO MAINTAIN CLEANLINESS)

POST ICRA ILSM FIRE

INSPECTION SHEETS

VISIBLE TO PUBLIC

COVER ALL RETURNS AT THE

GRATE/DIFFUSERS

OPTIONAL EXHAUST DUCTS

(COVER THE GRATES AND THE DIFFUSERS)

A

E

A

DOOR OPENING

VENT TO OUTSIDE

ROUTE TO BE

APPROVED BY OWNER

ICRA, ILSM, FIRE WATCH AND

MISC. FORMS

PAPER

CADDY

1'-5"

ILSM SIGNAGE

• THIS EXIT IS CLOSED AND LEADS TO A

CONSTRUCTION AREA

• PLEASE USE ALTERNATE EXITS AS MARKED

INTERIM LIFE SAFETY MEASURES IN EFFECT FOR THE

REMODEL PROJECT

SWIVEL

CASTERS

WITH TWO

LOCKING

BRAKES

PLASTIC

WINDOW

(OPTIONAL)

MOBILE CART

HEPA AIR UNIT

EXISTING WALL

EXISTING CEILING

ADJUSTABLE

PORTION OF CART

SEAL TIGHT TO EXISTING

CEILING

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

G-100

ICRA DETAILS

2 2

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

1/2" = 1'-0"

CROSS SECTION A

1/2" = 1'-0"

ICRA TYPICAL CONSTRUCTION PLAN

LAYOUT

6" = 1'-0"

ILSM SIGNAGE

1/2" = 1'-0"

HEPA CART

24514

LICENSED

ARCHITECT

DEMOLITION NOTES

1. KEY NOTES AND DRAWINGS ARE INTENDED TO GRAPHICALLY REPRESENT

GENERAL WORK AND DO NOT PORTRAY FULL SCOPE OF THE PROJECT. SEE

SPECIFICATIONS FOR DETAILED REQUIREMENTS.

2. REMOVE EXISTING CONSTRUCTION AS DESIGNATED HEREIN AND CLEAR AREA

OF DEBRIS PRIOR TO PROCEEDING WITH NEW CONSTRUCTION.

3. EXISTING EQUIPMENT REMOVED SHALL BE PROPERLY DISPOSED OFF MEDICAL

CENTER GROUNDS.

4. PATCHED WALL OPENING SHALL MATCH THE INTEGRITY OF ADJACENT

CONSTRUCTION UNLESS INDICATED OTHERWISE.

5. NOTIFY COR OF ANY DEMOLITION REQUIRED AND NOT INDICATED FOR

INSTALLATION OF ELECTRICAL OR DATA ITEMS. AFTER SUCH DEMOLITION AND

INSTALLATION, PATCH OR REPLACE MATERIALS AND FINISHES TO MATCH

EXISTING.

6. THE INFORMATION CONTAINED IN THESE DEMOLITION DOCUMENTS DEFINES

GENERAL SCOPE ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF THE

RESPONSIBILITY OF PROVIDING ALL DEMOLITION REQUIRED FOR THE

COMPLETION OF THE PROJECT.

7. REFER TO THE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION

REGARDING DEMOLITION OF ELECTRICAL SYSTEMS.

8. BEFORE THE START OF WORK, IDENTIFY ANY REQUIRED DEMOLITION BEYOND

THE IDENTIFIED PROJECT SCOPE WHETHER ABOVE, BELOW OR OUTSIDE

PROJECT AREA. NOTIFY AND COORDINATE WITH THE COR, PROVIDE

DEMOLITION OF THESE AREAS AND PATCH THE SAME AS A PART OF THE

SCOPE OF THE PROJECT.

9. ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND

DILIGENCE IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION OF

SERVICE OR CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE.

DISCOVERY OF UTILITIES OR CONDITIONS LOCATED DIFFERENTLY FROM THAT

INDICATED OR THAT ARE NOT IDENTIFIED. SHALL BE REPORTED TO THE

CONTRACTING OFFICER.

GENERAL NOTES

1. INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN FOR GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF THE DESIGNER AS TO THE LIMITATIONS OF THE WORK AREA IN AN OCCUPIED AREA. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY AGREEMENT BETWEEN THE COR AND

CONTRACTOR BEFORE THE START OF THE WORK.

2. DRAWINGS ARE PREPARED USING DIMENSIONS AND PRODUCT DRAWINGS ARE PREPARED USING DIMENSIONS. DETAILS AND DIMMENSIONS FOR SPECIFIC PRODUCTS MAY CHANGE BEFORE THEY ARE INCORPORATED INTO THE WORK AS WELL AS OTHER MANUFACTURERS BEING ACCEPTABLE. THEREFORE, ACTUAL INSTALLATION DETAILS AND DIMENSIONS MAY BE DIFFERENT THAN SHOWN. CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL PRODUCTS BEING INCORPORATED INTO THE WORK. SEE

SPECIFICATIONS FOR SUBMITTAL PROCEDURES.

3. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR CONVENIENCE. THE SEPARATIONS USED ARE USED ONLY FOR THE PURPOSES OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS, OR OF THE DRAWINGS AND SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO BE CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED WHOLE.

4. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY SPECIFIC ARCHITECTURAL AND ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATION FROM THE COR PRIOR TO BIDDING. WHERE

INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING.

5. USE OF THE WORD "VERIFY" POINTS OUT A SITUATION WHICH MUST BE CONFIRMED PRIOR TO PROCEEDING WITH THE WORK, FABRICATION OF EQUIPMENT, OR ORDERING MATERIAL. NOTIFY THE COR OF ANY

DISCREPANCY DISCOVERED.

6. THE CONTRACTOR SHALL NOTIFY THE COR IMMEDIATELY SHOULD DISCREPANCIES BE FOUND IN THE

DRAWINGS AND SPECIFICATIONS.

7. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD CONDITIONS AND DIMENSIONS AS THEY RELATE TO THIS PROJECT. SHOULD DISCREPANCIES EXIST BETWEEN THE WORK INDICATED AND ACTUAL FIELD

CONDITIONS NOTIFY THE COR PRIOR TO PROCEEDING WITH THE WORK.

8. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR REFERENCE ONLY AND ARE NOT INTENDED TO ACCURATELY DEPICT ACTUAL OR DESIGNATED CONDITIONS. WRITTEN DIMENSIONS SHALL

GOVERN.

9. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.

10. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE CONTRACTOR

SHALL FURNISH ALL NECESSARY PERMITS.

11. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF THE DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS (DRAWINGS, SPECIFICATIONS, ADDENDA, ETC.)

INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL AND ENGINEERING DESIGN CONCEPTS, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL, MECHANICAL, ELECTRICAL, AND DATA SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE NECESSARY WORK REQUIRED FOR FULL PERFORMANCE OF, AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THEIR WORK. ALL WORK SHALL BE COMPLETE IN EVERY DETAIL AND THE CONTRACTORS SHALL PROVIDE A ONE YEAR WARRANTY FOR THEIR WORK UNLESS

A LONGER WARRANTY IS INDICATED IN THE SPECIFICATIONS.

12. CONTRACTORS SHALL FOLLOW AND OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY

REGULATIONS AND HAZARDOUS WASTE LAWS, ETC.

AFF ABOVE FINISHED FLOOR

ACP/APC ACOUSTIC CEILING PANEL/

ACOUSTIC PANEL CEILING

ACT ACOUSTIC(AL) TILE

ADJ ADJUSTABLE

ADT'L ADDITIONAL

AGG AGGREGATE

ALT ALTERNATE

AL ALUMINUM

APPROX APPROXIMATE(LY)

ASPH ASPHALT

AUTO AUTOMATIC

B/O BOTTOM OF

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BOT BOTTOM

BRG BEARING

CENTERLINE

C/C CENTER TO CENTER

CJ CONTROL JOINT

CLL CONTRACT LIMIT LINE

CEM CEMENT(ITIOUS)

CMU CONCRETE MASONRY UNIT

CLG CEILING

CLR CLEAR

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

COR CONTRACTING OFFICER REPRESENTATIVE

CPT CARPET

CT CERAMIC TILE

CTR CENTER(ED)

DF DRINKING FOUNTAIN

DS DOWNSPOUT

DBL DOUBLE

DEG DEGREE

DEMO DEMOLITION

DET/DTL DETAIL

DIA DIAMETER

DIM DIMENSION

DN DOWN

DWG(S) DRAWING(S)

E EAST

EC ELECTRICAL CONTRACTOR

EHO ELECTRICAL HOLD OPEN

EJ EXPANSION JOINT

EW EACH WAY

EA EACH

EIFS EXTERIOR INSULATION

FINISH SYSTEM

EL ELEVATION

ELEC ELECTRIC(AL)

ELEV ELEVATOR

EMER EMERGENCY

EQ EQUAL

EQUIP EQUIPMENT

EXIST EXISTING

EXT EXTERIOR

EWC ELECTRIC WATER COOLER

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FFE FINISH FLOOR ELEVATION

FV FIELD VERIFY

FEC FIRE EXTINGUISHER CABINET

FDN FOUNDATION

FIN FINISH

FLSHG FLASHING

FLR FLOOR

FRMG FRAMING

FT FOOT/FEET

FTG FOOTING

GC GENERAL CONTRACTOR

GA GAUGE

GALV GALVANIZED

GEN GENERAL

GYP GYPSUM

HM HOLLOW METAL

HDWR HARDWARE

HOL HOLLOW

HOR HORIZONTAL

HT HEIGHT

HVAC HEATING/VENTILATION/AIR

CONDITIONING

IDPH ILLINOIS DEPARTMENT OF

PUBLIC HEALTH

ID INSIDE DIAMETER

IN INCH

INCL INCLUDING

INSUL INSULATION

INT INTERIOR

JAN JANITOR

JT JOINT

LAV LAVATORY

LB(S) POUND(S)

L/S LANDSCAPE

LT LIGHT

MO MASONRY OPENING

MAS MASONRY

MAT'L MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTD MOUNTED

MTL METAL

N NORTH

NIC NOT IN CONTRACT

NTS NOT TO SCALE

NOM NOMINAL

OC ON CENTER

OD OUTSIDE DIAMETER

O TO O OUT TO OUT

OPNG OPENING

OPP OPPOSITE

OVHD OVERHEAD

PEB PRE-ENGINEERED BUILDING

PJF PREFORMED JOINT FILLER

PT PRESSURE TREATED

PERIM PERIMETER

PL PLATE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PNT PAINT

PR PAIR

PTD PAINTED

PWR POWER

RB RUBBER BASE

RD ROOF DRAIN

RO ROUGH OPENING

RAD RADIUS

REC RECESSED

REINF REINFORCED

REQ'D REQUIRED

REV REVISED (REVISION)

RM ROOM

S SOUTH

SB SPLASH BLOCK

SF SQUARE FEET

SS STAINLESS STEEL

SIM SIMILAR

SPEC SPECIFICATIONS

SQ SQUARE

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

T&G TONGUE AND GROOVE

T/O TOP OF

TELE TELEPHONE

TRTD TREATED

TS TUBE STEEL

TYP TYPICAL

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITION TILE

VIF VERIFY IN FIELD

VERT VERTICAL

W WEST

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WWF WELDED WIRE FABRIC

WD WOOD

WH WATER HEATER

WT WEIGHT

CL

DEMOLITION KEYNOTE

WINDOW TYPE

TOILET ACCESSORY

WALL TYPE

DOOR NUMBER

TYPICAL KEYNOTE CEILING/ SOFFIT

HEIGHT

MATL

1'-0"

-1

WALL SECTION

SYMBOL

INTERIOR ELEVATION

SYMBOL

COLUMN GRID

ELEVATION SYMBOL

REVISION NOTE

ENLARGED DETAIL CALLOUT

ROOM DESIGNATION

SYMBOL

BREAK LINE

ROOF SLOPE

DIRECTION SYMBOL

TYPICAL GRAPHIC SCALE

DETAIL #

PAGE #

DETAIL #

PAGE #

TRUE NORTH ARROW

PROJECT NORTH ARROW

A8.1

EXTERIOR ELEVATION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

A8.1

BUILDING SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

DETAIL SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

WALL GRID

(REPRESENTS

FACE OF EXISTING

WALL)

XX.X

XX.X

ELEVATION

0'-0"

ROOM

NAME

101A

NORTH

PLAN

NORTH

TRUE

0 4 8 16

PRICING NOTES

BASE BID:

1.1 DEMOLITION AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

1.2 REPAIR TO EXISTING SYSTEM AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

1.3 NEW WORK AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

1.3.1 REUSE EXISTING PIPE RISERS AND LATERAL PIPING.

1.3.2 PROVIDE NEW VALVES (SERVICE, ZONE, LINE, RISER) AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

1.3.3 ONLY REPLACE LATERAL PIPING IF UNDERSIZED.

1.3.4 NEW EQUIPMENT AND PIPING AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

1.3.5 MINIMUM PIPING LENGTH REPLACEMENT THAT SHALL BE INCLUDED IN BID:

a. 2" --- 50'

b. 1 1/2" --- 50'

c. 1 1/4" --- 75'

d. 1" --- 75'

e. 3/4" --- 75'

f. 1/2" --- 100'

g. 3/8" --- 50'

DEDUCT ALTERNATES:

2.1 DEMOLITION OF MEDICAL GAS OUTLETS (HEAD WALLS) AND LATERAL PIPING UP TO THE RISER ON FIFTH FLOOR.

2.2 DEMOLITION OF NURSE CALL SYSTEM AND WIRING ON FIFTH FLOOR.

2.3 DEDICATED MEDICAL AIR UNIT AND PIPING FOR ENDOSCOPE STORAGE UNITS.

ALTERNATE BID:

3.1 DEMOLITION AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

3.2 REPAIR TO EXISTING SYSTEM AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

3.3 NEW WORK AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

3.3.1 PROVIDE NEW PIPE RISERS AND LATERAL PIPING.

3.3.2 PROVIDE NEW VALVES (SERVICE, ZONE, LINE, RISER).

3.3.3 NEW EQUIPMENT AND PIPING.

3.3.4 LATERAL PIPE ROUTING TO FOLLOW EXISTING ROUTING.

UNIT PRICING:

4.1 CONTRACTOR SHALL PROVIDE UNIT PRICING FOR BASE BID.

4.1.1 FOURTH FLOOR EACH WING.

4.1.2 FOURTH FLOOR EACH ROOM TYPE.

4.1.3 THIRD FLOOR EACH WING.

4.1.4 THIRD FLOOR EACH ROOM TYPE.

4.1.5 SECOND FLOOR.

4.1.6 FIRST FLOOR EACH WING.

4.1.7 GROUND FLOOR.

ROOM TYPES ARE IDENTIFIED ON SHEET P-501.

VA SHALL DECIDE FLOOR / ROOM PRIORITY LIST AT THE TIME OF CONTRACT FINALIZATION.

1.

2.

3.

4.

5.

6.

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

A-001

ARCHITECTURAL SYMBOLS,

ABBREVIATIONS, AND NOTES

1 7

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

ABBREVIATIONS

ARCHITECTURAL SYMBOL LEGEND

GENERAL SYMBOL LEGEND

24514

LICENSED

ARCHITECT

R A

M P

FE

FE

FE

FE

FE

FE

FE

422' - 0"

420' - 0"

422' - 0"

420' - 0"

422' - 0"

422' - 0"

DN

UP

UP

UP

UP

UP

UP

UP

UP

UP

01A

01C

07A

07B

07C

07D

07E

07F

07G

07H

07I

07J

07K

07L

07M

07N

07O

07P

07Q

07R

07S

09A

18 18A

17A

17B

17C

GSTAIR

GSTAIR

09B

10A

10B

10C

11A

14A

15A

16A

GB

GSTAIR

01B

GSTAIR

44A

44B

45A

47A

01D

GD

GA1

60A

60B

60C

GG/GP1

66A

68A

GSTAIR

78 79

79A

GE

07T

1. WHERE MEDICAL "HEADWALL" UNIT WAS

REMOVED THIS ROOM: PATCH WALL

OPENING WITH 1/2" GYPSUM BOARD

AND/OR PLASTER AS REQUIRED TO INFILL

THE OPENING AND CREATE A SMOOTH

SURFACE. FINISH AND PAINT TO MATCH

EXISTING ADJACENT WALL. PAINT ENTIRE

WALL.

2. REMOVE AND REPLACE EXISTING

ACOUSTICAL CEILING TILES IN THIS AREA

AS REQUIRED TO COMPLETE MEDICAL GAS

WORK.

3. REMOVE AND REPLACE EXISTING GYPSUM

BOARD CEILING IN THIS AREA AS REQUIRED

TO COMPLETE MEDICAL GAS WORK.

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

A-100

GROUND FLOOR PLAN - OVERALL

2 7

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

A. SEE SHEET A-001 FOR GENERAL NOTES

1/16" = 1'-0"

GROUND FLOOR PLAN- OVERALL

24514

LICENSED

ARCHITECT

FE

FE

FE

FE

FE

FE

433' - 0"

433' - 0"

433' - 0"

10001001 1002

1007A

1STAIR

1009A

1011 1012

1STAIR

1STAIR

B

1025A

1027A

1030 1031 1032

1B

1STAIR

1STAIR

C

10621063

1060A

1064A106410651065A

1A

1STAIR

1003A

1068A

1075A

10811082

1STAIR

11011102110311041105110611071108

1110A

1110B

11151116

1115A

1E1129

1STAIR

1147 11491A1

1STAIR

1166A

1F

1A3

1D2

1D

1STAIR

A

1C

1130A

DN

DN

DN

DN

DN

DN

DN

DN

UP

UP

FE

FE

FE

FE

FE

FE

FE

01A

01C

07A

07B

07C

07D

07E

07F

07G

07H

07I

07J

07K

07L

07M

07N

07O

07P

07Q

07R

07S

09A

18 18A

17A

17B

17C

GSTAIR

GSTAIR

09B

10A

10B

10C

11A

14A

15A

16A

GB

GSTAIR

01B

GSTAIR

44A

44B

45A

47A

01D

GD

GA1

60A

60B

60C

GG/GP1

66A

68A

GSTAIR

78 79

79A

GE

07T

1 1

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

A-101

FIRST FLOOR PLAN- OVERALL

3 7

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

1/16" = 1'-0"

FIRST FLOOR PLAN - OVERALL

A. SEE SHEET A-001 FOR GENERAL NOTES

24514

LICENSED

ARCHITECT

FE

FE

FE

FE

FOLDING

PARTITION

445' - 7 1/4"

445' - 7 1/4"

446' - 1 1/4"

445' - 7 1/4"

445' - 7 1/4"

445' - 7 1/4"

445' - 7 1/4"

2002A

2005 2006

2STAIR

2018A

2036 2037

2037A 2037B

2STAIR

2C

2042A

2055A

2054A

20592060

206420652000A

2STAIR

2C

2STAIR

2070C

2070A

2074A

2D

2075A

2075B

2077A

2077B

2077C

2078A

2078B

2078C

2000B

2D2081

2097B

2098A

2098B

2E

2109B

2STAIR

2113 21142113A

2A1

2STAIR

21282127A

2131 2132

2A

2B

2F

2F

2STAIR

A

2STAIR

BDN

UP

DN

UP

1. WHERE MEDICAL "HEADWALL" UNIT WAS

REMOVED THIS ROOM: PATCH WALL

OPENING WITH 1/2" GYPSUM BOARD

AND/OR PLASTER AS REQUIRED TO INFILL

THE OPENING AND CREATE A SMOOTH

SURFACE. FINISH AND PAINT TO MATCH

EXISTING ADJACENT WALL. PAINT ENTIRE

WALL.

2. REMOVE AND REPLACE EXISTING

ACOUSTICAL CEILING TILES IN THIS AREA

AS REQUIRED TO COMPLETE MEDICAL GAS

WORK.

3. REMOVE AND REPLACE EXISTING GYPSUM

BOARD CEILING IN THIS AREA AS REQUIRED

TO COMPLETE MEDICAL GAS WORK.

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

A-102

SECOND FLOOR PLAN - OVERALL

4 7

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

1/16" = 1'-0"

SECOND FLOOR PLAN - OVERALL

A. SEE SHEET A-001 FOR GENERAL NOTES

24514

LICENSED

ARCHITECT

FE

FE

FE

FE

456' - 7 1/4"

456' - 7 1/4"

456' - 7 1/4"

3003 3004

3005A

3STAIR

3024A

3B

3026A

3029 3030

3034A 3035

3037A

3STAIR

3040A

3041A

30413042

3041C

3041B

3042A

3C

3054A

3054B

3STAIR

3072A

30763078

3STAIR

3085A

3094A

3094B

3000A

30983100

31063107

3110A

3111A 3111B

3111C

3E

3STAIR

3116A 3118 3119

3STAIR

A

3STAIR

31523153

3154 3155

3A

3D

3F

DN

UP

DN

UP

1 1

1 1

1. WHERE MEDICAL "HEADWALL" UNIT WAS

REMOVED THIS ROOM: PATCH WALL

OPENING WITH 1/2" GYPSUM BOARD

AND/OR PLASTER AS REQUIRED TO INFILL

THE OPENING AND CREATE A SMOOTH

SURFACE. FINISH AND PAINT TO MATCH

EXISTING ADJACENT WALL. PAINT ENTIRE

WALL.

2. REMOVE AND REPLACE EXISTING

ACOUSTICAL CEILING TILES IN THIS AREA

AS REQUIRED TO COMPLETE MEDICAL GAS

WORK.

3. REMOVE AND REPLACE EXISTING GYPSUM

BOARD CEILING IN THIS AREA AS REQUIRED

TO COMPLETE MEDICAL GAS WORK.

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

A-103

THIRD FLOOR PLAN - OVERALL

5 7

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

1/16" = 1'-0"

THIRD FLOOR PLAN - OVERALL

A. SEE SHEET A-001 FOR GENERAL NOTES

24514

LICENSED

ARCHITECT

FE

FE

467' - 7 1/4"

467' - 7 1/4"

467' - 7 1/4"

4003A

4B

4STAIR

4032 4033

4034A4031A

4STAIR

4037A

4038A

4038B

4038C4040

4C

40474048

4STAIR

4054A

4054B

4054C

4056A

4056B

4D

4A

40654066

4073 4073A

4074A

4074B

4076A

4STAIR

4080A

4A1

4STAIR

4109 4110

4109A

4E

4F

4B

DN

DN

UPUP

1. WHERE MEDICAL "HEADWALL" UNIT WAS

REMOVED THIS ROOM: PATCH WALL

OPENING WITH 1/2" GYPSUM BOARD

AND/OR PLASTER AS REQUIRED TO INFILL

THE OPENING AND CREATE A SMOOTH

SURFACE. FINISH AND PAINT TO MATCH

EXISTING ADJACENT WALL. PAINT ENTIRE

WALL.

2. REMOVE AND REPLACE EXISTING

ACOUSTICAL CEILING TILES IN THIS AREA

AS REQUIRED TO COMPLETE MEDICAL GAS

WORK.

3. REMOVE AND REPLACE EXISTING GYPSUM

BOARD CEILING IN THIS AREA AS REQUIRED

TO COMPLETE MEDICAL GAS WORK.

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

A-104

FOURTH FLOOR PLAN - OVERALL

6 7

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

3/32" = 1'-0"

FOURTH FLOOR PLAN - OVERALL

A. SEE SHEET A-001 FOR GENERAL NOTES

24514

LICENSED

ARCHITECT

FE

FOLDING

PARTITION

479' - 6 1/4"

479' - 6 1/4"

479' - 6 1/4"

5004 5005 5006 5007

5011A

5011B

5STAIR

5STAIR

5025A

502950305031

503450355037

5A2

5STAIR

5043A

5A1

5047504850495051

5STAIR

5067 5068

5066A

5A1

5074A

5D

5A

5B

5C

5E

5F

5STAIR

DNDN

UP

1 1 1 1 1 1 1 1 1 1 1

1. WHERE MEDICAL "HEADWALL" UNIT WAS

REMOVED THIS ROOM: PATCH WALL

OPENING WITH 1/2" GYPSUM BOARD

AND/OR PLASTER AS REQUIRED TO INFILL

THE OPENING AND CREATE A SMOOTH

SURFACE. FINISH AND PAINT TO MATCH

EXISTING ADJACENT WALL. PAINT ENTIRE

WALL.

2. REMOVE AND REPLACE EXISTING

ACOUSTICAL CEILING TILES IN THIS AREA

AS REQUIRED TO COMPLETE MEDICAL GAS

WORK.

3. REMOVE AND REPLACE EXISTING GYPSUM

BOARD CEILING IN THIS AREA AS REQUIRED

TO COMPLETE MEDICAL GAS WORK.

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:3

:5

A

M

A-105

FIFTH FLOOR PLAN - OVERALL

7 7

DONALD WRIGHT

MK

JOHN J. PERSHING VAMC

1500 N WESTWOOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

RC

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

3/32" = 1'-0"

FIFTH FLOOR PLAN - OVERALL

A. SEE SHEET A-001 FOR GENERAL NOTES

24514

LICENSED

ARCHITECT

L L

ELECTRICAL ABBREVIATIONS LIST

SR SURFACE RACEWAY

SS STAINLESS STEEL

SSW SELECTOR SWITCH

STD STANDARD

SURF SURFACE MOUNTED

SW SWITCH

SWBD SWITCHBOARD

SYM SYMMETRICAL

SYS SYSTEM

TC TIMECLOCK

TEL TELEPHONE

TEL/DATA TELEPHONE/DATA

TERM TERMINAL

TP TW ISTED PAIR

TPS TW ISTED PAIR SHIELDED

TR TAMPER RESISTANT

T-STAT THERMOSTAT

TTB TELEPHONE TERMINAL BOARD

TTC TELEPHONE TERMINAL

CABINET

TV TELEVISION

TYP TYPICAL

UC UNDER COUNTER

UE UNDERGROUND ELECTRICAL

UG UNDERGROUND

UH UNIT HEATER

UL UNDERW RITER'S LABORATORY

UT UNDERGROUND TELEPHONE

UTP UNSHIELDED TWISTED PAIR

UTIL UTILITY

UV UNIT VENTILATOR OR

ULTRAVIOLET

V VOLT

VA VOLT-AMPERES

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

W WATT

W/ WITH

WH WATER HEATER

W/O WITHOUT

WP WEATHERPROOF

XFMR TRANSFORMER

XFR TRANSFER

ANGLE

@ AT

DELTA

' FEET

" INCHES

# NUMBER

Φ PHASE

C CENTER LINE

P PLATE

MTR MOTOR, MOTORIZED

MTS MANUAL TRANSFER SWITCH

NA NOT APPLICABLE

NC NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURER'S ASSOCIATION

NFDS NON-FUSED SAFETY DISCONNECT

SWITCH

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OH OVERHEAD

OL OVERLOAD

PA PUBLIC ADDRESS

PB PULL BOX OR PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT

UNIT

PCB POLYCHLORINATED BYPHENYL

PC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PIV POST INDICATING VALVE

PNL PANEL

POE POWER-OVER-ETHERNET

PR PAIR

PRI PRIMARY

PROJ PROJECTION

PRV POWER ROOF VENTILATOR

PT POTENTIAL TRANSFORMER

PVC POLYVINYL CHLORIDE (CONDUIT)

PWR POWER

QTY QUANTITY

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RTU ROOF TOP UNIT

SC SURFACE CONDUIT

SEC SECONDARY

SF SQUARE FEET/FOOT

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SIM SIMILAR

S/N SOLID NEUTRAL

SPEC SPECIFICATION

SPKR SPEAKER

SP SPARE

1P 1 POLE (2P, 3P, 4P, ETC.)

1PH 1 PHASE

2/C TWO-CONDUCTOR (3/C, 4/C, ETC.)

W2 TWO-WIRE (3W, 4W, ETC.)

3PH 3 PHASE

A AMPERE

AAP ALARM ANNUNCIATOR PANEL

AC ABOVE COUNTER

AIR CONDITIONER

ALTERNATING CURRENT

ACC ACCESSIBLE

ACLG ABOVE CEILING

ADO AUTOMATIC DOOR OPENER

A/E ARCHITECT/ENGINEER

AF AMP FRAME

AFC AVAILABLE FAULT CURRENT (KILOAMPS)

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFI ARC FAULT CIRCUIT INTERRUPTER

AHJ AUTHORITY HAVING JURISDICTION

AHU AIR HANDLING UNIT

AIC AMPERE INTERRUPTING CAPACITY

AL ALUMINUM

ALT ALTERNATE

AMP AMPERE

APPROX APPROXIMATELY

ARCH ARCHITECT, ARCHITECTURAL

AT AMP TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AWG AMERICAN WIRE GAUGE

BAS BUILDING AUTOMATION SYSTEM

BATT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISHED FLOOR

BLDG BUILDING

BMS BUILDING MANAGEMENT SYSTEM

BYP BYPASS

C CONDUIT

CAB CABINET

CALC CALCULATED

CAP CAPACITY

CAT CATALOG, CATEGORY

CATV COMMUNITY ANTENNA TELEVISION

CB CIRCUIT BREAKER

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR-FURNISHED

CKT CIRCUIT

CLG CEILING

CO CONTRACTING OFFICER

COAX COAXIAL CABLE

COMM COMMUNICATION

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUATION OR CONTINUOUS

CONTR CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER'S

REPRESENTATIVE

CPT CONTROL POW ER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CTR CENTER

CU COPPER

CU FT CUBIC FEET

dB DECIBEL

DB DIRECT BURIAL

DC DIRECT CURRENT

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLISH/DEMOLITION

DEPT DEPARTMENT

DIA DIAMETER

DISC DISCONNECT

DIST DISTRIBUTION

DN DOW N

DS SAFETY DISCONNECT SWITCH

DT DOUBLE THROW

DWG DRAWING

EC ELECTRICAL CONTRACTOR

EG EQUIPMENT GROUND

ELEC ELECTRIC, ELECTRICAL

ELEV ELEVATOR

EM EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMS ENERGY MANAGEMENT SYSTEM

EMT ELECTRICAL METALLIC TUBING

EPO EMERGENCY POWER OFF

EQUIP EQUIPMENT

ESMT EASEMENT

ETR EXISTING TO REMAIN

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WALL HEATER

ELECTRIC WATER HEATER

EX EXISTING

EXP EXPLOSION PROOF

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FCU FAN COIL UNIT

FIXT FIXTURE

FLR FLOOR

FLUOR FLUORESCENT

FU FUSE

FUDS FUSED SAFETY DISCONNECT SWITCH

FVR FULL VOLTAGE REVERSING

FVNR FULL VOLTAGE NON-REVERSING

GAL GALLON

GALV GALVANIZED

GC GENERAL CONTRACTOR

GEN GENERATOR

GFI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

GRS GALVANIZED RIGID STEEL (CONDUIT)

GYP BDGYPSUM BOARD

HID HIGH-INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HTR HEATER

HV HIGH VOLTAGE

HVAC HEATING, VENTILATING AND AIR

CONDITIONING

IES ILLUMINATION ENGINEERING SOCIETY

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

IR INFRARED

I/W INTERLOCK WITH

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

KV KILOVOLT

KVA KILOVOLT-AMPERE

KVAR KILOVOLT-AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

LED LIGHT-EMITTING DIODE

LF LINEAR FEET/FOOT

LM LUMEN

LRA LOCKED ROTOR AMPS

LT LIGHT

LTG LIGHTING

LTNG LIGHTNING

LV LOW VOLTAGE

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC MECHANICAL CONTRACTOR

METAL-CLAD (CONDUIT)

MCA MINIMUM CIRCUIT AMPACITY

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MFR MANUFACTURER

MFS MAIN FUSED DISCONNECT SWITCH

MH MANHOLE

MIC MICROPHONE

MIN MINIMUM

MISC MISCELLANEOUS

MLO MAIN LUGS ONLY

MOA MULTIOUTLET ASSEMBLY

MSBD MAIN SW ITCHBOARD

MT MOUNT

A1 b

E1 c d

T1

'LPN'

ELECTRICAL SYMBOL NOTES

THE LIGHTING FIXTURE TYPE IS INDICATED BY AN UPPER CASE LETTER OR AN UPPER

CASE LETTER AND NUMBER.

THE SW ITCH DESIGNATION (IF NEEDED) IS INDICATED BY A LOWER CASE LETTER.

EXAMPLE: LIGHTING FIXTURE TYPE 'A1' IS CONTROLLED BY SWITCH 'b'.

EXIT SIGNS: STEM INDICATES W ALL MOUNTING. NO STEM INDICATES CEILING

MOUNTING. SHADED AREA INDICATES ILLUMINATED FACE(S). ARROW INDICATES

DIRECTIONAL ARROW ON ILLUMINATED FACE(S).

DEVICES: THE SWITCH DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

THE CONTROL DEVICE DESIGNATION IS INDICATED BY A LOWER CASE LETTER.

TRANSFORMERS: THE TRANSFORMER TYPE IS INDICATED BY A NUMBER

FOLLOWING THE UPPER CASE LETTER 'T'. SEE THE TRANSFORMER SCHEDULE OR

THE SINGLE LINE DIAGRAM FOR THE TRANSFORMER DESCRIPTION AND

REQUIREMENTS.

PANELBOARDS: PANELBOARD DOORS MAY BE SHOWN TO INDICATE OPENING

SIDE OF RECESSED PANELBOARDS. SEE PANELBOARD IDENTIFICATION FOR

DESIGNATION CODES.

SHEET KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE NOTE

NUMBER INDICATED IN THE HEXAGON.

HOME RUN TO BRANCH CIRCUIT PANEL: THE PANEL DESIGNATION AND CIRCUIT

DESIGNATION ARE SHOWN ADJACENT TO THE HOME RUN ARROW .

CIRCUIT BREAKER SIZES (AMPS/NUMBER OF POLES) ARE SHOWN IN THE PANEL

SCHEDULE WITH THE CORRESPONDING PANEL AND CIRCUIT DESIGNATION.

SYMBOL NOTATIONS: UPPER CASE LETTERS ADJACENT TO SYMBOLS INDICATE

A UNIT TYPE. SEE APPROPRIATE SCHEDULE OR SPECIFICATIONS.

'LPN'-1,3,5

EXAMPLE 1: W ALL MOUNTED EXIT SIGN TYPE 'E1' WITH SINGLE FACE

AND DIRECTIONAL ARROW.

EXAMPLE 2: CEILING MOUNTED EXIT SIGN TYPE 'E2' W ITH DOUBLE

FACE AND DIRECTIONAL ARROWS.

E2

EXAMPLE: SPLIT DUPLEX RECEPTACLE; ONE RECEPTACLE OUTLET IS

CONTROLLED BY SWITCH 'c'.

EXAMPLE: SINGLE POLE SWITCH 'd' TO CONTROL LIGHTING FIXTURES INDICATED BY 'd'.

EXAMPLE: TRANSFORMER TYPE 'T1'.

EXAMPLE: HOME RUN TO PANELBOARD 'LPN'; CIRCUITS 1, 3, 5.

# DEMOLITION KEY NOTE: SEE THE SHEET KEY NOTES ON THAT SHEET FOR THE

NOTE NUMBER INDICATED IN THE SQUARE.

GENERAL ELECTRICAL NOTES

1. ALL ELECTRICAL DEVICES, FIXTURES, EQUIPMENT AND FEEDERS SHALL BE INSTALLED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, THE MANUFACTURER'S RECOMMENDED PROCEDURES, ALL APPLICABLE LOCAL AND STATE CODES, AMERICANS WITH DISABILITIES ACT AND WITH THE LATEST EDITION OF THE NATIONAL

ELECTRICAL CODE AND VA STANDARDS.

2. PROVIDE ADDITIONAL SUPPORT FOR DEVICES, FIXTURES, EQUIPMENT AND FEEDERS WHERE THE BUILDING

CONSTRUCTION IS NOT SUITABLE FOR DIRECT MOUNTING.

3. FIRESTOP, DRAFTSTOP, SMOKESTOP AND/OR PROTECT THE ANNULAR SPACE AROUND ALL PENETRATIONS THROUGH WALLS, PARTITIONS, FLOORS, CEILING, AND ROOFS IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, UL LISTING REQUIREMENT AND THE APPLICABLE BUILDING CODES.

4. VERIFY CEILING SYSTEMS AND PROVIDE MOUNTING ACCESSORIES, TRIMS AND ALL REQUIRED MOUNTING

HARDWARE TO SUIT THE PARTICULAR INSTALLATION.

5. PROTECT EXISTING UNDERGROUND AND BUILDING INTERIOR UTILITIES DURING CONSTRUCTION.

6. BRANCH CIRCUIT CONDUCTORS SHALL BE 12 AWG COPPER MINIMUM.

7. COORDINATE ANY AND ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION SO AS TO AVOID CONFLICT

DURING CONSTRUCTION.

8. ALL PANELS SHALL HAVE TYPED, COMPLETED DIRECTORIES INDICATING EQUIPMENT SERVED AND ROOM NUMBER (AS INDICATED ON FINAL BUILDING ROOM SIGNAGE) OF EQUIPMENT LOCATION, OR SPARE, OR SPACE.

9. MANUFACTURER'S NAME AND MODEL NUMBER ARE GIVEN FOR DESCRIPTIVE PURPOSES, TO INDICATE A QUALITY STANDARD, AND ARE NOT INTENDED TO LIMIT PRODUCTS TO A PARTICULAR MANUFACTURER.

PRODUCTS DEEMED EQUAL AND APPROVED BY THE DESIGNER WILL BE ACCEPTED. ALL PRODUCTS MUST

COMPLY WITH "BUY AMERICAN ACT".

10. ALL FEEDERS AND CIRCUITRY SHALL BE TORQUED PER THE PANEL, BREAKER, AND/OR PARTICULAR EQUIPMENT

MANUFACTURER'S SPECIFICATIONS.

11. CIRCUITRY TO SW ITCHES, RECEPTACLES, AND ALL OTHER DEVICES SHALL BE TERMINATED ON THE DEVICE'S

SCREW TERMINALS.

12. MOUNTING HEIGHTS INDICATED ARE TO CENTER OF DEVICE, OUTLET, FIXTURE, OR EQUIPMENT UNLESS NOTED

OTHERWISE.

13. ALL WIRE TERMINATIONS SHALL BE RATED FOR 75 DEGREES C.

14. ALL CONDUCTORS SHALL HAVE THHN/THWN INSULATION, UNLESS OTHERWISE NOTED.

15. ALL CONDUIT SHALL BE RGS OR EMT UNLESS OTHERWISE NOTED. FMC CONDUIT SHALL BE USED ON VIBRATING EQUIPMENT (MAXIMUM LENGTH OF 6 FEET). PVC SHALL BE USED FOR UNDERGROUND CONDUIT OR WHERE CONCRETE-ENCASED. WHERE VIBRATING EQUIPMENT IS LOCATED OUTSIDE, LFMC CONDUIT SHALL BE USED

(MAXIMUM SIX FEET) FOR FINAL CONNECTIONS.

16. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LABEL LISTED BY AN APPROVED

THIRD PARTY TESTING AGENCY.

17. FOR ALL LED FIXTURES, THE FIXTURE MUST BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY W HERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, WILL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY. PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

18. IN CASE OF CONFLICTS OR DISCREPANCIES WITHIN OR AMONG THE CONTRACT DRAWINGS, THE BETTER QUALITY, MORE STRINGENT REQUIREMENTS OR GREATER QUANTITY OF WORK , AS DETERMINED BY THE

GOVERNMENT, SHALL BE PROVIDED.

19. COMPRESSION COUPLINGS SHALL BE USED. NO SET SCREW FITTINGS ARE ALLOWED.

20. ONLY ONE OR TW O ROOM SHALL BE AVAILABLE FOR CONTRACTOR TO DO THE W ORK AT A TIME.

SHORT CIRCUIT CURRENT CALCULATIONS SHALL BE

PERFORMED ON THE ELECTRICAL SYSTEM USING A

BOLTED THREE PHASE FAULT CONDITION FOR

CALCULATIONS TO ACHIEVE MAXIMUM THERMAL AND

MECHANICAL STRESS TO THE SYSTEM FOR

CALCULATIONS PURPOSES. EXISTING SHORT CIRCUIT

VALUES WILL BE USED OUTSIDE THE WORK AREA, FOR

THE STARTING POINT OF THE CALCULATIONS.

METHOD OF SHORT CIRCUIT

CURRENT CALCULATIONS

USING OHM'S LAW AND THE KNOWN RESISTIVITY

CONSTANT OF CONDUCTOR METAL (CIRCULAR MIL-OHM

PER FOOT) FOR COPPER CONDUCTORS, CALCULATE THE

REQUIRED WIRE SIZE NECESSARY SO AS NOT TO EXCEED

THE RECOMMENDED VOLTAGE DROP OF 3% FOR BRANCH

CIRCUIT CONDUCTORS.

METHOD OF VOLTAGE DROP

CALCULATIONS

ELECTRICAL SYMBOL LEGEND

120V DUPLEX RECEPTACLE

RECEPTACLE MODIFIERS:

AC: 3" ABOVE COUNTERTOP/BACKSPLASH

GFI: GROUND FAULT CURRENT INTERRUPTER

WP: WEATHERPROOF ENCLOSURE

DED: DEDICATED CIRCUIT

120V DUPLEX RECEPTACLE EMERGENCY OUTLET

AND COVER PLATE SHALL BE RED IN COLOR

120V QUADRUPLEX RECEPTACLE

120V QUADRUPLEX RECEPTACLE EMERGENCY

OUTLET AND COVER PLATE SHALL BE RED IN COLOR

JUNCTION BOX, WALL MOUNTED, PURPOSE AS NOTED

DISCONNECT SWITCH NON-FUSED

DISCONNECT SW ITCH FUSED

SINGLE POLE WALL SWITCH: 48" AFF STANDARD UNO

SYMBOL HEIGHT DESCRIPTION

18"

18"

18"

18"

AS

NOTED

72" TOP

72" TOP

SWITCH MODIFIERS:

M: MOTOR-RATED

48"

ALL HEIGHTS ARE TO CENTER OF DEVICE UNLESS NOTED OTHERWISE.

TOP: HEIGHT TO TOP OF DEVICE

ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE LISTED HERE.

SPECIAL RECEPTACLE

EQUIPMENT CONNECTION

AS

NOTED

E

208V DUPLEX RECEPTACLE18"

18"

120V DUPLEX RECEPTACLE FLOOR BOX

120V DUPLEX RECEPTACLE EMERGENCY FLOOR BOX

OUTLET AND COVER PLATE SHALL BE RED IN COLOR

120V QUADUPLEX RECEPTACLE FLOOR BOX

120V QUADUPLEX RECEPTACLE EMERGENCY

FLOOR BOX OUTLET AND COVER PLATE SHALL BE

RED IN COLOR

CLNG

J

J

J

JUNCTION BOX, CEILING MOUNTED, PURPOSE AS

NOTED

JUNCTION BOX, FLOOR MOUNTED, PURPOSE AS

NOTED

LIGHTING SYMBOL LEGEND

2' X 2' RECESSED DIRECT/INDIRECT TROFFER

2' X 4' RECESSED DIRECT/INDIRECT TROFFER

SYMBOL

HEIGHT

AFF * DESCRIPTION

--- 2' X 4' RECESSED FLAT PRISMATIC LENS TROFFER

WALL SCONCE

6'-0"

CENTER

6" DIAMETER RECESSED DOWNLIGHT---

EXIT SIGN - WALL MOUNTED

EXIT SIGN - CEILING MOUNTED---

7'-5"

BOTTOM

SINGLE POLE WALL SWITCH

SWITCH MODIFIERS:

OS: OCCUPANCY SENSOR, DUAL TECHNOLOGY

VS: VACANCY SENSOR, DUAL TECHNOLOGY

LV: LOW VOLTAGE

LVD: LOW VOLTAGE DIMMER

D: LINE VOLTAGE DIMMER

T: DIGITAL TIMER

K: KEYED

3: 3 WAY

48"

CENTER

OCCUPANCY SENSOR, DUAL

TECHNOLOGY - CEILING MOUNTED

--- LOW VOLTAGE LIGHTING CONTROL DEVICE

OCCUPANCY SENSOR, DUAL

TECHNOLOGY - WALL/CORNER MOUNTED

2' LINEAR - W ALL MOUNTED

7'-0"

CENTER

EMERGENCY LIGHT BATTERY

OPERATED - WALL MOUNTED

7'-6"

CENTER

RC

* - ANY HEIGHTS INDICATED IN PLANS SHALL SUPERCEDE THOSE

LISTED HERE.

LIGHT LEVEL SENSOR, SINGLE ZONE

DIMMING CLOSED LOOP - CEILING MOUNTED

--- LOW VOLTAGE LIGHTING CONTROL

DEVICE WITH 0-10V DIMMING

RCD

4' LINEAR - W ALL MOUNTED

7'-0"

CENTER

OS

OS

LS

DEDUCT ALTERNATES:

1. DEMOLITION OF MEDICAL GAS OUTLETS (HEAD WALLS) ON FIFTH FLOOR.

2. DEMOLITION OF NURSE CALL SYSTEM ON FIFTH FLOOR.

3. DEDICATED MEDICAL AIR UNIT FOR ENDOSCOPY SUITE.

PRICING NOTES

BASE BID:

1.1 DEMOLITION AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

1.2 NEW WORK AS IDENTIFIED IN CONSTRUCTION DOCUMENTS.

1.2.1 REUSE EXISTING EQUIPMENT WHERE INDICATED ON DRAWINGS.

1.2.2 REPLACE EXISTING EQUIPMENT WITH NEW WHERE INDICATED ON DRAWINGS.

1.2.3 REMOVE EXISTING EQUIPMENT WHERE INDICATED ON DRAW INGS.

1.2.4 RELOCATE EXISTING EQUIPMENT WHERE INDICATED ON DRAWINGS.

1.2.5 SEE SHEET NTOES AND KEY NOTES FOR DETAILS AS INDICATED ON DRAWINGS.

DEDUCT ALTERNATES:

2.1 DEMOLITION OF NURSE CALL SYSTEM AND WIRING ON FIFTH FLOOR.

UNIT PRICING:

3.1 CONTRACTOR SHALL PROVIDE UNIT PRICING FOR BASE BID.

3.1.1 FOURTH FLOOR EACH WING.

3.1.2 FOURTH FLOOR EACH ROOM TYPE.

3.1.3 THIRD FLOOR EACH WING.

3.1.4 THIRD FLOOR EACH ROOM TYPE.

3.1.5 SECOND FLOOR.

3.1.6 FIRST FLOOR EACH WING.

3.1.7 GROUND FLOOR.

VA SHALL DECIDE FLOOR / ROOM PRIORITY LIST AT THE TIME OF CONTRACT FINALIZATION.

1.

2.

3.

4.

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:1

:0

A

M

E-001

ELECTRICAL GENERAL NOTES,

SYMBOL LEGENDS, AND

ABBREVIATIONS

1 11

DONALD WRIGHT

JWB

JOHN J. PERSHING VAMC

1500 N W ESTW OOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

DS

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

M P

FEFE

422' - 0" 422' - 0"

420' - 0"

422' - 0"

DN

UP

UP

UP

UP

UP

MATCHLINE MATCHLINE MATCHLINE

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:1

:1

A

M

EP101

GROUND FLOOR ELECTRICAL PLAN -

AREAS A, B, & F

2 11

DONALD WRIGHT

JWB

JOHN J. PERSHING VAMC

1500 N W ESTW OOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

DS

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

0 105 20

NORTH

PLAN

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

Scale: 1" = 10'-0"

GROUND FLOOR ELECTRICAL PLAN - AREAS A, B, & F

A. NO ELECTRICAL WORK .

M P

FE

FE

FE

FE

FE

422' - 0"

420' - 0"

422' - 0"

420' - 0"

422' - 0"

UP

UP

UP

UP

UP

GN₁

GN₁

GN₁

UP

MATCHLINE MATCHLINE MATCHLINE

EXISTING MEDICAL AIR

EXISTING VACUUM PUMP

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:1

:1

A

M

EP102

CRAW LSPACE AND GROUND FLOOR

ELECTRICAL PLAN - AREAS C, D, E, & G

3 11

DONALD WRIGHT

JWB

JOHN J. PERSHING VAMC

1500 N W ESTW OOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

DS

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

0 105 20

NORTH

PLAN

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

Scale: 1" = 10'-0"

GROUND FLOOR ELECTRICAL PLAN - AREAS C, D, E, & G

Scale: 1" = 10'-0"

CRAWLSPACE ELECTRICAL PLAN 0 105 20

NORTH

PLAN

A. SOME ROOMS WILL HAVE THE HEADWALL

REMOVED ENTIRELY. IF SO THE HEADW ALL

RECEPTACLES WILL BECOME WALL

RECEPTACLES.

B. REMOVE RECEPTACLES WILL BECOME THE

PROPERY OF THE CONTRACTOR AND WILL BE

DISPOSED OF.

C. RECEPTACLE COVER PLATES SHALL BE

MARKED WITH PANEL NUMBER AND CIRCUIT

NUMBER. BLACK RECEPTACLES ARE LOCATED

IN OR NEAR OR FED FROM HEADWALL.

D. ILLUMINATED RED RECEPTACLES SHALL BE

REPLACED WITH SAME KIND.

E. THE CONTRACTOR IS RESPONSIBLE FOR

TEMPORARILY REMOVING EXISTING LIGHTING

FIXTURES DURING THE REMOVAL OF THE

CEILING. THE CONTRACTOR IS THEN

RESPONSIBLE FOR THE REINSTALLATION OF

THE LIGHT FIXTURES W HEN THE CEILING HAS

BEEN RETURNED TO ITS ORIGINAL

CONFIGURATION.

FE

FE

FE

433' - 0"

433' - 0"

DN

DN

DN

DN

UP

UP

1NT₆

1NT₆

1NT₆ 1NT₆

1NT₁1NT₁

MATCHLINE MATCHLINE MATCHLINE

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:1

:1

A

M

EP103

FIRST FLOOR ELECTRICAL PLAN -

AREAS A, B, & F

4 11

DONALD WRIGHT

JWB

JOHN J. PERSHING VAMC

1500 N W ESTW OOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

DS

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

0 105 20

NORTH

PLAN

1 HEADWALL RECEPTACLES IN THIS ROOM TO

BE REPLACED WITH SAME KIND. REUSE

COVERPLATES. 5 RECEPTACLES TOTAL, 2

RED, 3 IVORY.

2 HEADWALL RECEPTACLES IN THIS ROOM TO

BE REPLACED WITH SAME KIND. REUSE

COVERPLATES. 1 RECEPTACLE TOTAL, 1

RED.

3 HEADWALL RECEPTACLES IN THIS ROOM TO

BE REPLACED WITH SAME KIND. REUSE

COVERPLATES. 4 RECEPTACLES TOTAL, 4

RED.

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

Scale: 1" = 10'-0"

FIRST FLOOR ELECTRICAL PLAN - AREAS A, B, & F

A. SOME ROOMS WILL HAVE THE HEADWALL

REMOVED ENTIRELY. IF SO THE HEADW ALL

RECEPTACLES WILL BECOME WALL

RECEPTACLES.

B. REMOVE RECEPTACLES WILL BECOME THE

PROPERY OF THE CONTRACTOR AND WILL BE

DISPOSED OF.

C. RECEPTACLE COVER PLATES SHALL BE

MARKED WITH PANEL NUMBER AND CIRCUIT

NUMBER. BLACK RECEPTACLES ARE LOCATED

IN OR NEAR OR FED FROM HEADWALL.

D. ILLUMINATED RED RECEPTACLES SHALL BE

REPLACED WITH SAME KIND.

E. SEE "MEDICAL GAS AND ELECTRICAL OUTLET

SCHEDULE", SHEET P-603, FOR ADDITIONAL

INFORMATION ON OUTLET COUNT.

F. THE CONTRACTOR IS RESPONSIBLE FOR

TEMPORARILY REMOVING EXISTING LIGHTING

FIXTURES DURING THE REMOVAL OF THE

CEILING. THE CONTRACTOR IS THEN

RESPONSIBLE FOR THE REINSTALLATION OF

THE LIGHT FIXTURES W HEN THE CEILING HAS

BEEN RETURNED TO ITS ORIGINAL

CONFIGURATION.

FE

433' - 0"

433' - 0"

DN

DN

DN

DN

DN

UP

1NT₂

1NT₄

1NT₄

1NT₃

1NT₅

1NT₃

1NT₃

MATCHLINE MATCHLINE MATCHLINE

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:1

:1

A

M

EP104

FIRST FLOOR ELECTRICAL PLAN -

AREAS C, D, & E

5 11

DONALD WRIGHT

JWB

JOHN J. PERSHING VAMC

1500 N W ESTW OOD BLVD

POPLAR BLUFF, MO 63901 July 30, 2020

100% CONSTRUCTION DOCUMENTS

657A4-19-10319-065

DS

RECERTIFY AND EVALUATE FOR CORRECTION

OF MEDICAL GAS, MEDICAL VACUUM, DENTAL

VACUUM, AND OXYGEN SYSTEMS

0 105 20

NORTH

PLAN

N

KEY PLAN

SCALE: NO SCALE

A

C

B

D

E

F

G

Scale: 1" = 10'-0"

FIRST FLOOR ELECTRICAL PLAN - AREAS C, D, & E

1 HEADWALL RECEPTACLES IN THIS ROOM TO

BE REPLACED WITH SAME KIND. REUSE

COVERPLATES. 4 RECEPTACLES TOTAL, 4

RED.

A. SOME ROOMS WILL HAVE THE HEADWALL

REMOVED ENTIRELY. IF SO THE HEADW ALL

RECEPTACLES WILL BECOME WALL

RECEPTACLES.

B. REMOVE RECEPTACLES WILL BECOME THE

PROPERY OF THE CONTRACTOR AND WILL BE

DISPOSED OF.

C. RECEPTACLE COVER PLATES SHALL BE

MARKED WITH PANEL NUMBER AND CIRCUIT

NUMBER. BLACK RECEPTACLES ARE LOCATED

IN OR NEAR OR FED FROM HEADWALL.

D. ILLUMINATED RED RECEPTACLES SHALL BE

REPLACED WITH SAME KIND.

E. SEE "MEDICAL GAS AND ELECTRICAL OUTLET

SCHEDULE", SHEET P-603, FOR ADDITIONAL

INFORMATION ON OUTLET COUNT.

F. THE CONTRACTOR IS RESPONSIBLE FOR

TEMPORARILY REMOVING EXISTING LIGHTING

FIXTURES DURING THE REMOVAL OF THE

CEILING. THE CONTRACTOR IS THEN

RESPONSIBLE FOR THE REINSTALLATION OF

THE LIGHT FIXTURES W HEN THE CEILING HAS

BEEN RETURNED TO ITS ORIGINAL

CONFIGURATION.

FE

FE

FE

FE

FOLDING

PARTITION

445' - 7 1/4"

446' - 1 1/4"

445' - 7 1/4"

445' - 7 1/4"

DN

UP

DN

UP

2NT₁2NT₁

MATCHLINE MATCHLINE MATCHLINE

## KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

W ALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RESISTIVE HAZARDOUS AREA

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 © COPYRIGHT Apogee Consulting Group, P.A.

/3

/2

:1

:1

A

M

EP105

SECOND FLOOR ELECTRICAL PLAN -

A…