DEPARTMENT OF THE ARMY

Project Manager, Mission Command

6560 Surveillance Loop Aberdeen Proving Ground, Maryland 21005-1848

SFAE-CCC-MC 4 June 2019

MEMORANDUM FOR U.S. Army Communications Electronics Command (CECOM) C3T Directorate, Director (Mr. Joe Cattelona), 6590 Reconnaissance St. Aberdeen Proving Ground, MD 21005.

SUBJECT: Standardized Integrated Command Post Systems (SICPS) Trailer Mounted Support System (TMSS) Tent/Shelter Interchangeabilty & Substituability (I&S) Recommendation

1. References:

a. Offering of Substitutes DLA Policy, dtd 30 September 1997

b. AMC R 700-30 Elimination of Duplicate Management I&S

c. AMMCI 20-101 Elimination of Duplicate I&S

d. MIL-STD-461E Requirements for Control of Electromagnetic Interference

Characteristics Subsystems and Equipment

e. MIS-PRF-54581C Command Post Platform (CPP) Development and Integration

Program

f. MIS-PRF-961E Tent, Extendable, Modular, Personnel (TEMPER)

g. MIL-STD-1472F Human Engineering

h. MIL-STD-882 Performing Hazard Analyses

i. MIL-STD-40015-2B Military Publications

j. TM 11-6115-742-13-1, -13-2, and -23P; Utility Power Plant [TMSS-Med

Analog/Digital]

k. TM 11-6115-743-13-1, -13-2, and -23P; Utility Power Plant [TMSS-Med Analog]

l. TM 11-6115-748-13-1, -13-2, and -23P; Utility Power Plant [TMSS-Med Analog]

m. TM 11-6115-774-13-1, -13-2, and -23P; Utility Power Plant [TMSS-Med Digital]

n. TM 11-6115-775-13-1, -13-2, and -23P; Utility Power Plant [TMSS-Lrg Digital]

o. Network Integration Evaluation (NIE) 14.2 Annex B. Command Post Operational

Energy System (CPOES), dtd 20 June 2014

p. Final Report for the Developmental Test (DT) of the HDT 32 Series AirBeam

Shelter, ATEC Project No. 2013-DT-ATC-RDECO-F4871, Report No. ATC- 11337, dtd April 2015

q. MFR: New Air Supported (AS) Command Post (CP) Configurations added to the Army Standard Tent, Extendable, Modular, Personnel (TEMPER) Family of Shelters”, dtd 18 November 2016

2. Product Manager Command Post Infrastructure Integration (PdM CPI2) approves the following HDT AirBeam tent/shelters for SICPS Program of Record (POR) and requests that the tent/shelter I&S relationship is established to ensure ongoing

SFAE-CCC-MC

Subject: SICPS TMSS Tent/Shelter interchangeabilty & Substituability (I&S) Recommendation

TMSS supportability. Current DRASH models are nearing their 12 year life cycle and are subject to extended procurement lead times:

a. AirBeam model Series 32, NSN 8340-01-657-0010 (large green)

b. AirBeam model Series 32, NSN 8340-01-657-0038 (large tan)

c. AirBeam model Series 20, NSN 8340-01-656-3890 (medium green)

d. AirBeam model Series 20, NSN 8340-01-656-3894 (medium tan)

3. The change affects the SICPS Family of the TMSS Medium and Large products

(LINs P63394 and P63462) TMSS-Large models PU-824A/T, PU-824B/T, and PU- 824C/T Utility Power Plants DRASH J series Tent and the TMSS-Medium models PU-821/T, PU-821A/T, PU- 822A/T, and PU-822B/T Utility Power Plants.

4. These AirBeam model tent/shelters are compliant as "drop-in" replacement that should be integrated into the current TMSS configurations and replace the DRASH tents through attrition. They comply with I&S standards and meet configuration management form, fit, and function requirements. TMSS systems are required to operate on the battlefield and integrate with DRASH, AirBeam, and Base-X tents.

This has been verified during independent testing by ATEC on behalf of Product Manager Force Sustainment Systems (PdM FSS) and during the Network Integration Evaluation (N.I.E) 14.2 event at Ft. Bliss, TX. The MIL-PRF-961E standards governing tentage has been met.

5. The NSNs are DLA managed and readily available using the DoD supply system, along with required support component parts. When the new AirBeam tent is requisitioned, the user will receive all required ancillary items to raise the tent.

6. PdM CPI2 requests all DLA databases to be updated to reflect this I&S mission performance and Army readiness for unit replacement when DRASH tents are not mission capable (NMC), not economically repairable, or missing. A Mil-Std 1432A compliant manual is to be prepared for the AirBeam tent/shelters by PdM FSS from the existing HDT Global COTS manual. The TMSS technical manuals will list these AirBeam items as Additional Authorized Items (AAI) list.

7. The Point of Contact (POC) for this request is David Meickle, 443-395-2642, david.w.meickle.civ@mail.mil.

Rodney G. Bilbrew

LTC, SC

Product Manager, CPI2