TMM 2515_Architecture_BID DOCUMENTS.pdf

PDF 8 MB Posted

Attached to
Y1PZ--Project 629-25-104 ED Suicide Risk Mitigation Fence
Solicitation number
36C25626R0117
Issued by

About this file

These are architectural bid documents for the ED Drive Suicide Mitigation project at the Southeast Louisiana Veterans Health Care System located at 2400 Canal Street, New Orleans, Louisiana 70119 (Project Number 629-25-104). The documents are prepared by the U.S. Department of Veterans Affairs Office of Construction and Facilities Management with consultation from Cleveland/Mizell/Molinar and dated April 9, 2026.

The project scope encompasses installation of an anti-climb security fence system with wire mesh infill on the second level of the facility. The fence design must be engineered to resist specific live loads including 400 pounds vertical load at midspan, 5 PSF horizontal load or 50 pounds over a 12-inch by 12-inch area, ice loads, wind loads (ultimate design wind speed 153 MPH), and seismic forces (Risk Category IV, Seismic Design Category C). The fence system requires hot-dip galvanized steel construction per ASTM A123/A123M standards followed by zinc phosphate, epoxy powder coat, and polyester color coat finishes. All sections must include UV-stabilized polymer post caps, with rails configured to serve as raceways for communication or video cabling. The fence must be grounded in accordance with NEC Article 250.194, with connections not exceeding 150 feet unless otherwise noted. The contractor must coordinate with the government's separately contracted equipment suppliers, verify all existing conditions prior to commencing work, and obtain COR approval for any post-installed anchors in lieu of cast-in-place anchors. Design codes include the 2024 International Building Code, ANSI/ASCE 7-16, ACI 318-19, and VA Structural Design Manual PG-18-10.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INDEX OF DRAWINGS

GI001

SHEET

NO.

DRAWING TITLE

GENERAL

GI002

ARCHITECTURAL

SHEET

NO.

COVER SHEET

LEGENDS, ABBREVIATIONS AND NOTES

PARTIAL FLOOR PLAN - SECOND LEVEL NORTH ENDAE101

ED DRIVE SUICIDE MITIGATION

PROJECT NUMBER: 629-25-104

BID DOCUMENTS

SOUTHEAST LOUSIANA VETERANS HEALTH CARE SYSTEM

2400 CANAL ST, NEW ORLEANS, LA 70119

LOCATION MAP

NOT TO SCALE

AREA MAP

NOT TO SCALE

PROJECT LOCATION

PROJECT LOCATION

TRUE

NORTH

PLAN

NORTH

PARTIAL FLOOR PLAN - SECOND LEVEL SOUTH ENDAE102

EXTERIOR ELEVATIONS - WEST AND NORTHAE201

EXTERIOR ELEVATIONS - EAST AND SOUTHAE202

INTERIOR ELEVATIONSAE451

DETAILSAE502

TRUE

NORTH

PLAN

NORTH

DRAWING TITLE

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

COVER SHEET

GI001

ARCHITECTURAL ABBREVIATIONSARCHITECTURAL LEGEND

GENERAL ARCHITECTURAL NOTES

GENERAL PROJECT NOTES

A

GA4

A301

A201

A401

ROOM

NAME

+ 0'-6"

F.E.C.

AIR CONDITIONING

ACOUSTICAL CEILING TILE

ABOVE FINISH FLOOR

ALUMINUM

BATT INSULATION

BOTTOM OF

CEMENTITIOUS BACKER BOARD

CEMENTITIOUS CRYSTALLINE WATERPROOFING

COLD-FORMED METAL FRAMING

CORNER GUARD

CENTERLINE

CONCRETE MASONRY UNIT

CASED OPENING

COMMUNICATION

CONCRETE

SEALED CONCRETE

CONTINUOUS

CONTRACTING OFFICER'S REPRESENTATIVE

CERAMIC TILE

CERAMIC TILE BASE

CARPET

DIAMETER

EXPANSION JOINT

ELECTRICAL

EPOXY FLOORING

EXPOSED STRUCTURE

ET CETERA

EXISTING

EXPOSED

FACTORY FINISH

FLOOR DRAIN

FIRE EXTINGUISHER CABINET

FIRE HOSE CABINET

FINISHED FLOOR

FINISH

FLOOR

FACE OF

FIELD VERIFY

FABRIC WALLCOVERING

GAGE

GRANITE

GYPSUM (WALL) BOARD

HANDICAPPED

HOLLOW METAL

HANDRAIL

HEATING VENTILATION AND AIR-CONDITIONING

MATERIAL

MAXIMUM

MECHANICAL

MANUFACTURER

MINIMUM

MASONRY OPENING

METAL

NOT IN CONTRACT

NOT TO SCALE

ON CENTER

OPPOSITE HAND

PLASTER

PLASTIC LAMINATE

PORCELAIN TILE

PAIR

PAINT

QUARRY TILE

RESILIENT BASE

REFRIGERATOR

REQUIRED

RESINOUS FLOORING

RESINOUS EPOXY WALL-CEILING

ROUGH OPENING

RUBBER FLOORING

RECESSED PAPER HOLDER

SEALED HIGH BUILD GLAZED COATING

SOLID CORE WOOD

SIMILAR

SPECIAL FACED

STAINLESS STEEL

STEEL

SUBSTRATE

SHEET VINYL

SOLID VINYL TILE

TELEPHONE

TOP OF

TYPICAL

UNLESS NOTED OTHERWISE

VINYL COMPOSITION TILE

VINYL WALL COVERING

WALL COVERING

WALL PROTECTION

WOOD

WELDED SEAM SHEET FLOORING

AC

AT

AFF

AL

BATT

BO

CBB

CCW

CFMF

CG

C

CMU

CO

COMM

CONC

SCONC

CONT

COR

CT

CTB

CP

DIA

EJ

ELEC

EPY

ES

ETC

EXIST

EXP

FAC FIN

FD

FEC

FHC

FF

FIN

FLR

FO

FV

FWC

GA

GRA

GYP BD/GWB

HC

HM

HR

HVAC

MATL

MAX

MECH

MFR

MIN

MO

MTL

NIC

NTS

OC

OH

PLS

PL

PT

PR

P

QT

RB

REF

REQ'D

RES

RES-W

RO

RF

RPH

SC

SCW

SIM

SP

SS

STL

SUBS

SV

SVT

TELE

TO

TYP

UNO

VCT

VWC

WC

WP

WD

WSF

L

FIRE EXTINGUISHER CABINET

ROOM NAME AND NUMBER

DOOR NUMBER

KEY NOTE

WINDOW TYPE

PARTITION TYPE

DETAIL CALLOUT

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

SECTION CALLOUT

VERTICAL ELEVATION

COLUMN CENTERLINE DESIGNATION

DEMOLITION KEY NOTE

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

INTERIOR FENCE ELEVATION CALLOUT

DETAIL NUMBER

SHEET WHERE DETAIL IS DRAWN

CARD READERCR

HIGH-PRESSURE LAMINATEHPL

LUXURY VINYL TILELVT

EDGE OF DECKEOD

DOWNSPOUTDS

CONTROL JOINTCJ

DRINKING FOUNTAINDF

FIRE RETARDANT TREATEDFRT

EXTERIOR INSULATION FINISHING SYSTEMEIFS

WATER RESISTANTWR

J1

SECTION CUT

HEAD/JAMB/SILL DETAIL NUMBER EQUALEQ

CARPET TILECPT

REFLECTED CEILING PLANRCP

SOLID SURFACE MATERIALSSM

X1045 EQUIPMENT JSN NUMBER

ALUMINUM COMPOSITE METAL PANELSACMP

A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO:

• FACE OF EXISTING WALL SURFACE

• FACE OF MASONRY

• FACE OF WALL STUDS

• TOP OF SLAB

• TOP OF MASONRY

B. COORDINATE WITH ALL DISCIPLINES DRAWINGS FOR ADDITIONAL REQUIREMENTS.

COORDINATE OPENINGS IN SLABS, ROOF, AND WALLS. WHERE HOLES IN EXISTING WALLS

AND SLABS ARE CREATED FOR PENETRATIONS, COORDINATE SIZE AND LOCATION. PATCH

HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLES, ETC.

WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE, MATERIAL,

THICKNESS, ALIGNMENT, GRADES, AND QUALITY.

C. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING,

INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED.

D. SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT REQUIRE PAINTING.

E. REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND AS

REQUIRED FOR CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS SHALL BE

REPAIRED TO ACCEPT NEAT INSTALLATION OF CONSTRUCTION OR FINISHES. WHERE

EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION, FLOORING, ETC.)

EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES

SHALL BE PREPARED AS INDICATED OR SPECIFIED PRIOR TO INSTALLATION OF

MATERIALS.

F. PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. REPAIR DAMAGES FROM

CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST

WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED.

A. THE CONTRACTOR SHALL BE PREPARED TO STOP ANY WORK AND CLEAN UP THE WORK AREA

AS DIRECTED IN MEDICAL SITUATIONS REQUIRING SUCH ACTION.

B. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR EQUIPMENT UNTIL

SUBMITTALS FOR SUCH HAVE BEEN APPROVED.

C. ALL TOOLS AND MATERIALS USED IN THIS PROJECT SHALL BE PROPERLY SECURED AT ALL

TIMES BY THE CONTRACTOR TO PREVENT THE POSSIBILITY OF ANY OF THESE TOOLS BEING A

HAZARD TO PATIENTS, VISITORS AND STAFF.

D. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR EACH MEMBER OF

HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED TO RECEIVE BADGES. COORDINATE

WITH COR.

E. THE CONTRACTOR, AT HIS EXPENSE, WILL BE RESPONSIBLE FOR TRAINING EACH MEMBER OF

HIS WORK FORCE ON VA POLICIES FOR ON-SITE WORK BEFORE ANY MEMBER WILL BE

ALLOWED TO PERFORM WORK ON VA PREMISES.

F. ABSOLUTELY NO VA TOOLS, MATERIALS OR EQUIPMENT WILL BE LOANED OR GIVEN BY THE VA

TO ANY MEMBER OF THE CONTRACTOR'S WORK FORCE AT ANY TIME.

G. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE,

DUST AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL ALARM DURING

CONSTRUCTION. ALL SUCH ACTION MUST BE FIRST COORDINATED AND CLEARED WITH THE

COR AND THE VA SAFETY OFFICER. ALL FUNCTIONAL FIRE ALARM DEVICES SHALL BE ACTIVE

WHENEVER THE CONTRACTOR'S FORCES ARE NOT PRESENT IN THE WORK AREA.

H. THE CONTRACTOR MUST PROVIDE WRITTEN FIRE SAFETY CHECKLIST AT THE END OF EVERY

WORK DAY TO THE COR CERTIFYING THAT ALL WORK AREAS HAVE BEEN SURVEYED AND

FOUND TO BE SECURE, SAFE AND FREE OF ANY FLAMMABLE LIQUIDS.

I. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING OFFICER.

J. SEE SPECIFICATIONS SECTIONS 01 00 00 AND 01 35 26 FOR INTERIM LIFE SAFETY MEASURES.

K. ALL FINISH COLORS TO BE SELECTED BY COR/ VA INTERIOR DESIGNER WHERE NOT

OTHERWISE INDICATED. CONTRACTOR SHALL SUBMIT COLORS FROM THE MANUFACTURER'S

FULL RANGE OF COLORS.

L. THE CONTRACTOR SHALL NOT OPERATE ANY EXISTING VA EQUIPMENT WITHOUT

AUTHORIZATION FROM VAMC ENGINEERING SERVICE UNLESS AN EMERGENCY SITUATION

OCCURS.

M. CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL REQUIRED EXIT LIGHTING AND SIGNAGE

REQUIRED FOR EGRESS WITHIN AND ADJACENT TO THE PROJECT AREA DURING

PERFORMANCE OF THE WORK.

N. INDICATED EXISTING CONDITIONS ARE BASED UPON LIMITED FIELD INVESTIGATION AND DID

NOT INCLUDE DESTRUCTIVE INVESTIGATION OR TESTING. CONTRACTOR SHALL VERIFY ALL

EXISTING CONDITIONS INCLUDING DIMENSIONS OF THE INSTALLED CONSTRUCTION PRIOR TO

COMMENCING WITH THE WORK. IF DISCREPANCIES ARE DISCOVERED, THE CONTRACTOR

SHALL NOTIFY THE COR FOR INTERPRETATION AND DIRECTION PRIOR TO PROCEEDING WITH

THE WORK.

O. COORDINATE WORK WITH EQUIPMENT SUPPLIER/ INSTALLER CONTRACTED SEPARATELY WITH

THE GOVERNMENT.

P. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST TO MAINTAIN LEVEL LINE

ALONG TOP OF FENCE.

Q. FIELD VERIFY EXISTING CONDITIONS. GROUT THICKNESS UNDER FENCE TUBE FRAME BASE

PLATES TO BE 1/2" MINIMUM, 1-1/2" MAXIMUM.

A ACCESSORY TYPE

DESIGN CODES

1.01 2024 INTERNATIONAL BUILDING CODE (IBC) AS MODIFIED BY:

A. ANSI/ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER

STRUCTURES

B. VA STRUCTURAL DESIGN MANUAL PG-18-10, JULY 1, 2023

C. VA SEISMIC DESIGN REQUIREMENTS H-18-8, 2020 EDITION

1.02 AMERICAN CONCRETE INSTITUTE (ACI)

A. ACI 318-19, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE

DESIGN LOADS

1.01 DESIGN LOADS ARE AS FOLLOWS:

A. FLOOR:

1. DEAD LOADS:

a. SELF WEIGHT OF MATERIALS

2. LIVE LOADS:

a. SEE ORIGINAL CONSTRUCTION DOCUMENTS

B. OTHER LOADS:

1. ANTI-CLIMB FENCING:

a. DESIGN ANTI-CLIMB FENCE SYSTEM TO RESIST THE FOLLOWING LIVE LOADS

IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE REQUIREMENTS.

• FENCE PANELS SHALL BE CAPABLE OF SUPPORTING A 400 LB. (882 KG)

VERTICAL LOAD APPLIED AT MIDSPAN WITHOUT PERMANENT

DEFORMATION.

• HORIZONTAL LOAD OF 5 PSF, OR 50 LBS OVER A 12 IN X 12 IN AREA NOT

CONCURRENTLY

• ICE LOADS DUE TO FREEZING RAIN: SEE ASCE 7

• WIND LOAD: SEE ASCE 7 AND CRITERIA BELOW

• WIND ON ICE-COVERED STRUCTURES: SEE ASCE 7 AND CRITERIA BELOW

• SEISMIC: WHEN REQUIRED, SEE EARTHQUAKE CRITERIA BELOW

C. WIND LOADS:

1. ULTIMATE DESIGN WIND SPEED Vult = 153 MPH

2. IMPORTANCE FACTOR Iw = 1.0

3. RISK CATEGORY IV

4. WIND EXPOSURE = B

D. SNOW LOADS:

1. GROUND SNOW LOAD, Pg: 10 psf

E. EARTHQUAKE LOADS:

1. SEISMIC IMPORTANCE FACTOR I = 1.5

2. RISK CATEGORY = IV

3. MAPPED SPECTRAL RESPONSE ACCELERATIONS

a. Ss = 0.11g

b. S1 = 0.06g

4. SITE CLASS = D

5. SPECTRAL RESPONSE COEFFICIENTS (FOR SITE CLASS D)

a. Sds = 0.098

b. Sd1 = 0.066

6. SEISMIC DESIGN CATEGORY = C

7. BASIC SEISMIC-FORCE-RESISTING SYSTEM:

a. BUILDING FRAME SYSTEM

• ORDINARY REINFORCED CONCRETE MOMENT FRAMES

8. ANALYSIS PROCEDURE - EQUIVALENT LATERAL FORCE PROCEDURE

1.02 DEFLECTION CRITERIA: REFER TO TABLE 1604.3 FOR DEFLECTION LIMITS.

GENERAL STRUCTURAL NOTES

EXISTING CONDITIONS

1.01 AS WITH ANY WORK AFFECTING EXISTING CONSTRUCTION, UNFORESEEN CONDITIONS ARE UNAVOIDABLE WITHOUT DEMOLISHING OTHERWISE SERVICEABLE CONSTRUCTION, DISRUPTING OCCUPIED OPERATIONS AND INCURRING SIGNIFICANT COST FOR CLOSE UP EXAMINATION AND NON-DESTRUCTIVE TESTING DURING

THE DESIGN STAGE.

1.02 WITH THE PASSAGE OF TIME SINCE THE CREATION OF AS-BUILT DRAWINGS AND/OR THE DESIGNERS SURVEY, BOTH CONCEALED AND VISIBLE CONDITIONS MAY HAVE CHANGED DUE TO ALTERATIONS, ADDITIONS, RENOVATIONS AND DETERIORATION.

1.03 PRIOR TO THE COMMENCEMENT OF ANY WORK IN PREPARATION OF CONSTRUCTION RELATED ACTIVITIES, INCLUDING BUT NOT LIMITED TO SHOP DRAWING PREPARATION, ALL BURIED, EMBEDDED, AND CONCEALED ITEMS LIKELY TO BE ENCOUNTERED DURING CONSTRUCTION SHALL BE LOCATED AND MARKED ON THE SURFACE. THIS WORK SHALL BE ACCOMPLISHED BY DESTRUCTIVE AND/OR NON-DESTRUCTIVE MEANS WITHOUT IMPAIRING THE STRUCTURAL INTEGRITY OF THE ASSOCIATED MEMBERS. SHORING AS REQUIRED SHALL BE DESIGNED BY A PROFESSIONAL STRUCTURAL ENGINEER, LICENSED IN THE STATE OF THE

PROJECT, AND FURNISHED AND INSTALLED AT NO ADDITIONAL COST.

1.04 EXISTING CONDITIONS THAT INTERFERE OR OTHERWISE AFFECT THE DESIGN, CONSTRUCTION OR SERVICEABILITY OF THE WORK SHALL BE BROUGHT TO THE ATTENTION OF THE COR, INCLUDING PLAN AND SECTION SKETCHES, IMMEDIATELY FOR RESOLUTION. THE CONTRACTOR SHALL ALLOW TWO CALENDAR WEEKS IN THE SCHEDULE FOR DESIGN RESOLUTION THE INTERFERENCE AFTER ALL INFORMATION ABOUT THE INTERFERENCE, INCLUDING SIZE, LOCATION AND FUNCTION OF THE EMBEDMENT, HAS BEEN RECEIVED

BY THE STRUCTURAL ENGINEER.

ANTI-CLIMB FENCE DESIGN

1.01 THE VENDOR SHALL SUPPLY A TOTAL ARCHITECTURAL FENCE SYSTEM INCORPORATING AN ANTI-CLIMB DESIGN THAT INCLUDES ALL COMPONENTS (I.E. BRACKETS, PANELS, POSTS, AND HARDWARE) AS

REQUIRED FOR A COMPLETE INSTALLATION.

1.02 ENGINEERING RESPONSIBILITY: ENGAGE A FABRICATOR WHO ASSUMES UNDIVIDED RESPONSIBILITY FOR ENGINEERING FENCING, AND ALL ASSOCIATED CONNECTIONS TO NEW AND EXISTING STRUCTURE NOT SHOWN IN THESE DRAWINGS BY EMPLOYING A QUALIFIED PROFESSIONAL ENGINEER TO PREPARE AND

SEAL DESIGN CALCULATIONS, SHOP DRAWINGS, AND OTHER STRUCTURAL DATA.

1.03 HORIZONTAL MEMBERS THAT ARE ACCESSIBLE FROM THE OCCUPIED SIDE OF FENCE AND MIGHT BE USED AS FOOT- OR HAND-HOLDS SHALL EITHER BE SPACED AT A MINIMUM 8 FEET (2400 MM) APART OR DESIGNED

WITH ANTI-CLIMB FEATURES.

1.04 DESIGN FRAMING SYSTEMS TO PROVIDE FOR MOVEMENT OF FRAMING MEMBERS WITHOUT DAMAGE OR OVERSTRESSING, FABRIC FAILURE, CONNECTION FAILURE, UNDUE STRAIN ON FASTENERS AND ANCHORS, OR OTHER DETRIMENTAL EFFECTS WHEN SUBJECT TO BUILDING MOVEMENT, INCLUDING DRIFT AND DEFLECTION, OR THERMAL LOADS CAUSED BY A MAXIMUM AMBIENT TEMPERATURE CHANGE (RANGE) OF

67 DEGREES C (120 DEGREES F).

1.05 ALL SECTIONS AND PIECES OF THE FENCE MATERIAL, RAILS, FRAMING, ETC. WILL BE HOT DIP GALVANIZED.

THE GALVANIZING PROCESS MUST MEET ASTM A123/A123M STANDARDS. GALVANIZING COATING SHALL BE FOLLOWED BY A ZINC PHOSPHATE COAT, AND EPOXY POWDER COAT, AND A POLYESTER COLOR COAT.

SEE ARCHITECTURAL FOR ANY ADDITIONAL FINISH OR COLOR REQUIREMENTS.

1.06 FENCE PANELS WILL BE PROVIDED SO THAT LIMITED FIELD CUTTING AND FIELD FINISH PATCHING WORK IS REQUIRED. SUPPLY ADDITIONAL GALVANIZING MATERIAL FOR TOUCHING UP THE FENCE SYSTEM ON SITE.

ENSURE ALL AREAS AND COMPONENTS OF THE FENCE AND GATES ARE PROPERLY COATED.

1.07 EVERY POST OR OPENING IN THE TOP OF THE FENCE STRUCTURE WILL BE SEALED WITH A UV-STABILIZED

POLYMER POST CAP.

1.08 RAILS SHALL BE CONFIGURED AS TO ALLOW USE AS A RACEWAY FOR COMMUNICATION OR VIDEO

CABLING.

1.09 PROVIDE GUARDS AS REQUIRED TO PREVENT BEAMS, COLUMNS, OR OTHER HORIZONTAL PROJECTIONS

TO BE USED AS STEPS OR HAND-HOLDS.

1.10 BEFORE ANY CONCRETE DRILLING, LOCATE AND AVOID ALL REINFORCING, CONDUIT, OR OTHER ITEMS EMBEDDED IN CONCRETE BY GPR OR OTHER NON-DESTRUCTIVE MEANS AS APPROVED BY THE COR.

POST-INSTALLED ANCHORS

1.01 POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE COR PRIOR TO INSTALLING POST- INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REBAR. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS.

SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE COR ALONG WITH CALCULATIONS THAT ARE PREPARED & SEALED BY A

REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL DEMONSTRATE THAT THE

SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERTINENT EQUIVALENT PERFORMANCE VALUES

(MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR

STANDARD(S) AS REQUIRED BY THE BUILDING CODE.

1.02 CONCRETE ANCHORS

A. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED

AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. PRE-APPROVED

MECHANICAL ANCHOR MANUFACTURERS:

1. SIMPSON STRONG-TIE ANCHORING SYSTEMS

2. HILTI

3. POWERS

B. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC308. PRE-APPROVED ADHESIVE ANCHOR

MANUFACTURERS

1. SIMPSON STRONG-TIE ANCHORING SYSTEMS

2. HILTI

3. POWERS

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

LEGENDS, ABBREVIATIONS AND NOTES

GI002

DN

A

M

B

U

L

A

N

C

E

O N L Y

P A T I E N T

D R O P - O F F

N

A

M

B

U

L

A

N

C

E

O N L YN

A

M

B

U

L

A

N

C

2E250

2E252

2D255

2E254

2E256

2E258

2E258A

2E258B

2E182

2E183

2E178

2E180

2E181

2E176

90SF

130SF

501SF

821SF

112SF

149SF

105SF

296SF

358SF

HVC

COPY/WORK

AOD

OFFICE

DECONTAM

CONSULT

NURSE

MANAGER

ENTRANCE

VESTIBULE

ENTRANCE

VESTIBULE

CORR

2D-C12

ENTRANCE

VESTIBULE

2E184

ELEV

DP-10

ELEV

DP-09

2E-C12

CORR

2E182

2E181

2E -C

2E183

E- E2

-1

.2

2E180

2E

2E181

/4

T .I

A

M

B

U

L

A

N

C

E

O N

L Y

N L

Y

FLOOR PLAN LEGEND

EXISTING CONSTRUCTION TO REMAIN

CONSTRUCTION

FLOOR PLAN GENERAL NOTES

A. PATCH EXISTING RETAINED CONSTRUCTION ADJACENT TO INSTALLED CONSTRUCTION.

B. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS.

FLOOR MOUNTED FENCE WITH WIRE MESH.

FLOOR PLAN KEY NOTES

GROUNDING ROD, SEE SHEET AE502 FOR DETAILS.2

AE201

ed5 ed1 ed4 ed3 ed2 edDedF edC edAedB

FI

E

LD

V

E R

IF

Y

2'

4"

FIELD VERIFY

24' - 0"

FIELD VERIFY

56' - 6 1/8"

AE4515

AE451

AE502

MATCHLINE

AE101

AE502

Sim

AE502

Sim

AE451

AE4518

AE201

AE451

2 2

PROJECT AREA

KEY PLAN

NTS

MATCHLINE

ed1 edA

AE451

19' - 10" +/-

6" 14'-0"1

1'

3" 3'

8"

3'

4"

AE451

4"

6" 14'-0"

AE451 12

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

PARTIAL FLOOR PLAN - 2ND LEVEL NORTH END

AE101

TRUE

NORTH

PLAN

NORTH

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

1/8" = 1'-0"AE101

1 2ND LEVEL - NORTH END

1/4" = 1'-0"AE101

2 ENLARGED PLAN - STAIR 2ND LEVEL NORTH END

E

O N L YN

A

M

B

U

L

A

N

C

E

O N L YN

2E260

2E262

2E258B

2F317

2F315

2F313

2F311

2F309 2F307

2E175

2E174

2E176

358SF

227SF

24SF

294SF

120SF

138SF

118SF

279SF

236SF

F E

C

MULTI-PURPOSE

EC

ENTRANCE

VESTIBULE

STAIR

STF-04

EQUIP

CALIB

(NM)

2F180

RAD

RES

CONF

2F178

LINEN

ROOM

2F181

PACS

ADMIN

2F183A

BIO-MED

WORK

2F179

RAD

WASTE

2F177

DN

UP

2E174

2E175

2F

2F180

2F

2F181

2F183

2F179

ST

P

A

M

B

U

L

A

N

C

E

O N

L Y

N

A

M

B

U

L

A

N

C

E

O N

L Y

N

A

M

B

U

L

A

N

C

E

O N

L Y

N

A

M

B

U

L

A

N

C

E

O N

L Y

N

FLOOR PLAN LEGEND

EXISTING CONSTRUCTION TO REMAIN

CONSTRUCTION

FLOOR PLAN GENERAL NOTES

A. PATCH EXISTING RETAINED CONSTRUCTION ADJACENT TO INSTALLED CONSTRUCTION.

B. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS.

FLOOR MOUNTED FENCE WITH WIRE MESH.

FLOOR PLAN KEY NOTES

GROUNDING ROD, SEE SHEET AE502 FOR DETAILS.2

AE202

AE202

ed5 ed9 ed10 ed6 ed7 ed8 edDedF edC edA edBedGedHedIedJedKedL edB1edB2

FIELD VERIFY

111' - 8"

FI

E

LD

V

E R

IF

Y

AE451 2

AE451

AE451

FI

E

LD

V

E R

IF

Y

/4

FIELD VERIFY

178' - 2 1/4"

FIELD VERIFY

15' - 1"

F.V.

4' - 0"

F.V.

3' - 2"

MATCHLINE

AE201

AE451

AE201

AE451

2 2

2 2 2

AE451

PROJECT AREA

KEY PLAN

NTS

MATCHLINE

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

PARTIAL FLOOR PLAN - 2ND LEVEL SOUTH END

AE102

TRUE

NORTH

PLAN

NORTH

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

1/8" = 1'-0"AE102

1 2ND LEVEL - SOUTH END

LEVEL 1

0"

LEVEL 2

18'-10"

LEVEL 3

38'-0"

LEVEL 1 i 11'-8"

LEVEL 2 i 30'-8"

LEVEL 2 D

18'-4" ed5ed1 ed9 ed10ed6 ed7 ed8ed4ed3ed2 27 28293031323334353637

WIRE MESH

FENCE

LEVEL 1

0"

LEVEL 2

18'-10"

LEVEL 3

38'-0"

LEVEL 1 i 11'-8"

LEVEL 2 i 30'-8"

LEVEL 2 D

18'-4" edD edFedCedB edG edH edI edJ edK edLedB1 edB2

WIRE MESH

FENCE

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

EXTERIOR ELEVATIONS - WEST AND NORTH

AE201

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

1/8" = 1'-0"AE201

1 WEST ELEVATION

1/8" = 1'-0"AE201

2 NORTH ELEVATION

LEVEL 1

0"

LEVEL 2

18'-10"

LEVEL 3

38'-0"

LEVEL 1 i 11'-8"

LEVEL 2 i 30'-8"

LEVEL 2 D

18'-4" ed9ed10 ed7ed82728

WIRE MESH FENCE

LEVEL 1

0"

LEVEL 2

18'-10"

LEVEL 3

38'-0"

LEVEL 1 i 11'-8"

LEVEL 2 i 30'-8"

LEVEL 2 D

18'-4" edDedF edC edAedBedGedHedIedJedKedL edB1edB2

WIRE MESH FENCE

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

EXTERIOR ELEVATIONS - EAST AND SOUTH

AE202

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

1/8" = 1'-0"AE202

1 EAST ELEVATION

1/8" = 1'-0"AE202

2 SOUTH ELEVATION

AE502

AE502

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

AE502

Sim

AE502

TYP.

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

AE502

TYP.

AE502

Sim

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

AE502

Sim

AE502

Sim

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

ACCESS PANEL FOR

LIGHT POLE BEYOND

AE502

AE502

Sim

LEVEL 1

0"

LEVEL 2

18'-10"

6' -1

0" 6'

-1 0"

5' -2

3'

-8

5' -4

3'-6" 3'-6" 3'-6" 3'-6"

'-1

0"

14'-0" 6"

7'-0"7'-0"

AE502

1'-4"5'-8"

'-8

5'

-2

LEVEL 1

0"

LEVEL 2

18'-10"

'-1

0"

14'-0"

3'-6" 3'-6" 3'-6" 3'-6"

4' -8

/2

4'

-8

/2

4' -8

/2

4'

-8

/2

AE502

AE502

TYP.

AE502

TYP.

3'-11" 3'-8"

8' -9

AE502

TYP.

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

INTERIOR ELEVATIONS

AE451

0' 4' 8' 16' 24'

SCALE: 1/8" = 1' - 0"

1/8" = 1'-0"AE451

1 INTERIOR ELEVATION 1

1/8" = 1'-0"AE451

5 INTERIOR ELEVATION 3

1/8" = 1'-0"AE451

2 INTERIOR ELEVATION 2

1/8" = 1'-0"AE451

7 INTERIOR ELEVATION 4

1/8" = 1'-0"AE451

10 INTERIOR ELEVATION 5

1/8" = 1'-0"AE451

14 INTERIOR ELEVATION AT STAIRS

1/8" = 1'-0"AE451

13 INTERIOR ELEVATION AT STAIRS

1/8" = 1'-0"AE451

3 INTERIOR ELEVATION 6

1/8" = 1'-0"AE451

4 INTERIOR ELEVATION 7

1/8" = 1'-0"AE451

6 INTERIOR ELEVATION 8

1/8" = 1'-0"AE451

8 INTERIOR ELEVATION 9

1/8" = 1'-0"AE451

11 INTERIOR ELEVATION 10

1/8" = 1'-0"AE451

12 INTERIOR ELEVATION 11

1/8" = 1'-0"AE451

9 INTERIOR ELEVATION 12

9'

0" 3' - 9"

4"4"

8" 5'

0"

9'

0"

3' - 9"

AE502

STAINLESS STEEL

WIRE MESH

EXISTING

CONCRETE WALL

AE502

AE502

VENDOR-DESIGNED STEEL BASE

PLATE ON MIN 1/2", MAX 1-1/2" GROUT

AND CORROSION RESISTANT

FASTENERS

MIN 2" SPACE

TUBE FRAME

VERTICALS TO

ALIGN WITH THE

VERTICALS FROM

INFILL PANELS

BELOW, MAX. 4'-0"

O.C., SEE

ELEVATIONS

VENDOR-DESIGNED,

POWDER COATED

CARBON STEEL, MIN" 2"

SQUARE TUBE FRAME

VENDOR-DESIGNED WELDED PLATE

AT TOP OF POWDER COATED

CARBON STEEL TUBE VERTICALS AS

NEEDED TO PREVENT WATER

PENETRATION (TYP.)

ANCHOR VERTICALS TO INSIDE OF

EXISTING CONCRETE WALL, 6"

BELOW TOP OF WALL AND 6" ABOVE

FLOOR SLAB USING CORROSION

RESISTANT FASTENERS

AE502

VENDOR-DESIGNED

MIN 2" TUBE FRAME

WIRE MESH

COVER PLATE

6"

VENDOR-DESIGNED

MIN 2" TUBE FRAME

PLATE

COVER PLATE

WIRE MESH

1' - 0"

1'

0"

EXISTING CONCRETE WALL

VENDOR-DESIGNED,

POWDER COATED

CARBON STEEL, MIN 2"

SQUARE TUBE FRAME

VENDOR-DESIGNED STEEL

BASE PLATE ON MIN 1/2", MAX

1-1/2" GROUT AND CORROSION

RESISTANT FASTENERS

MIN 2" SPACE TUBE FRAME

VERTICALS TO ALIGN WITH

THE VERTICALS FROM INFILL

PANELS BELOW, MAX. 4'-0"

O.C., SEE ELEVATIONS

WALL FOOTING BEYOND

BACK FACE OF WALL PIER

GRADE LEVEL

WALL

COLUMN PIER

FOOTING STEEL

3/4" CONDUIT

GROUND ROD /

TEST WELL

CONCRETE SLAB

BOLTED CONNECTION TO BARE METAL

METAL FENCE

1/0 CU CABLE

1/0 CU CABLE

GROUNDING BUSHING

GROUNDING BUSHING

8' (MAX)

3' (MIN)

(M

IN

TO IMPROVE SYSTEM RESISTANCE, ERICO GEM MAY BE USED AS A BACKFILL

MATERIAL IN AN AUGURED HOLE. PROVIDE GROUND RODS TO ACHIEVE MAXIMUM

10 OHMS RESISTANCE.

1"x4" SLOT IN

12" PVC PIPE

GROUND CONDUCTOR, SIZE

AS NOTED ON PLANS

DRIVEN COPPER CLAD

GROUND ROD 5/8" x 10'

(SEE NOTE)

NOTE:

TEST WELL AND COVER

CADWELD TYPE GT

CLEAN SAND FILL

#2 AWG BCW TINNED PIGTAIL

24"

30" MIN

2"

2"

12" MIN

AE502

VENDOR-DESIGNED STEEL

BASE PLATE ON MIN 1/2", MAX

1-1/2" GROUT AND CORROSION

RESISTANT FASTENERS ON

SLOPE

MIN 2" SPACE TUBE FRAME

VERTICALS TO ALIGN WITH

THE VERTICALS FROM INFILL

PANELS BELOW, MAX. 4'-0"

O.C., SEE ELEVATIONS

VENDOR-DESIGNED

MIN 2" TUBE FRAME

VENDOR-DESIGNED STEEL

BASE PLATE ON MIN 1/2",

MAX 1-1/2" GROUT AND

CORROSION RESISTANT

FASTENERS

6"

9' -6

AE502

Sim

VA FORM 08-6231

1 2 3 4 5 6 7 8 9

DATE:

Drawing Title:

Approved Project Director

Project Title:

1 2 3 4 5 6 7 8 9

BID DOCUMENTS

512 MEANS ST NW

Phase Project Number

Building Number

Drawing NumberLocation

Issue Date Checked

STAMP

STE. 400

ATLANTA, GA 30318

ARCHITECT/ENGINEER OF RECORDCONSULTANT

A

B

C

D

E

F

U.S. Department of Veterans Affairs

Office of Construction and

Facilities Management

Drawn

SV SV,ZN

629-25-104

04-09-2026REVISIONS:

A

B

C

D

E

F

ED DRIVE SUICIDE MITIGATION

NEW ORLEANS, LA

DETAILS

AE502

3/8" = 1'-0"AE502

12 TYPICAL LIGHT POLE ACCESS PANEL ELEVATION

3/8" = 1'-0"AE502

11 TYPICAL FENCING ELEVATION

3/4" = 1'-0"AE502

6 TYPICAL SCURITY FENCE SECTION

3" = 1'-0"AE502

1 SECURITY FENCE WALL ANCHOR DETAIL

3" = 1'-0"AE502

3 DETAIL INTEGRATED ANGLED RETURN

1 1/2" = 1'-0"AE502

2 TYPICAL SECURITY FENCE ANCHORAGE DETAIL - PLAN VIEW

3" = 1'-0"AE502

4 SECURITY FENCE POST FLOOR ANCHOR DETAIL

12" = 1'-0"AE502

13 GND - COLUMN GROUNDING DETAIL

12" = 1'-0"AE502

5 GND - GROUND ROD INSPECTION WELL

GROUNDING ROD NOTE:

FENCE SHALL BE GROUNDED IN ACCORDANCE WITH NEC ARTICLE

250.194. ALL CORNERS SHALL BE GROUNDED TO THE EXISTING

GROUNDING SYSTEM OR BUILDING STEEL. FIELD VERIFY EXACT

CONNECTION LOCATION. NEW GROUND TEST WELL AND GROUND ROD

SHALL BE INSTALLED AS NEEDED. FENCE GROUNDING CONNECTIONS

SHALL NOT EXCEED 150'-0" UNLESS OTHERWISE NOTED.

3/8" = 1'-0"AE502

8 TYPICAL FENCING ELEVATION ON SLOPE

3" = 1'-0"AE502

9 SECURITY FENCE POST FLOOR ANCHOR DETAIL ON SLOPE

3" = 1'-0"AE502

10 SECURITY FENCE WALL AND FLOOR ANCHOR DETAIL

GENERAL NOTE:

1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST

TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.

2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.

GENERAL NOTE:

1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST

TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.

2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.

GENERAL NOTE:

1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST

TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.

2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.

GENERAL NOTE:

1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST

TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.

2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.

GENERAL NOTE:

1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST

TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.

2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.

GENERAL NOTE:

1. SHIMS TO BE INSTALLED AS NEEDED UNDER

BASE OF FENCE POST TO MAINTAIN LEVEL

LINE ALONG TOP OF FENCE.

2. VERIFY SLOPE WITH EXISTING CONDITONS

PRIOR TO FABRICATION.

GENERAL NOTE:

1. SHIMS TO BE INSTALLED AS NEEDED UNDER

BASE OF FENCE POST TO MAINTAIN LEVEL

LINE ALONG TOP OF FENCE.

2. VERIFY SLOPE WITH EXISTING CONDITONS

PRIOR TO FABRICATION.

3/8" = 1'-0"AE502

7 TYPICAL FENCING ELEVATION AT SKYLIGHT WALL

Sheets
AE101 - PARTIAL FLOOR PLAN - 2ND LEVEL NORTH END
AE102 - PARTIAL FLOOR PLAN - 2ND LEVEL SOUTH END
AE201 - EXTERIOR ELEVATIONS - WEST AND NORTH
AE202 - EXTERIOR ELEVATIONS - EAST AND SOUTH
AE451 - INTERIOR ELEVATIONS
AE502 - DETAILS
GI001 - COVER SHEET
GI002 - LEGENDS, ABBREVIATIONS AND NOTES

File details come from the government source that posted it. Updated .