TMM 2515_Architecture_BID DOCUMENTS.pdf
PDF 8 MB Posted
- Solicitation number
- 36C25626R0117
About this file
These are architectural bid documents for the ED Drive Suicide Mitigation project at the Southeast Louisiana Veterans Health Care System located at 2400 Canal Street, New Orleans, Louisiana 70119 (Project Number 629-25-104). The documents are prepared by the U.S. Department of Veterans Affairs Office of Construction and Facilities Management with consultation from Cleveland/Mizell/Molinar and dated April 9, 2026.
The project scope encompasses installation of an anti-climb security fence system with wire mesh infill on the second level of the facility. The fence design must be engineered to resist specific live loads including 400 pounds vertical load at midspan, 5 PSF horizontal load or 50 pounds over a 12-inch by 12-inch area, ice loads, wind loads (ultimate design wind speed 153 MPH), and seismic forces (Risk Category IV, Seismic Design Category C). The fence system requires hot-dip galvanized steel construction per ASTM A123/A123M standards followed by zinc phosphate, epoxy powder coat, and polyester color coat finishes. All sections must include UV-stabilized polymer post caps, with rails configured to serve as raceways for communication or video cabling. The fence must be grounded in accordance with NEC Article 250.194, with connections not exceeding 150 feet unless otherwise noted. The contractor must coordinate with the government's separately contracted equipment suppliers, verify all existing conditions prior to commencing work, and obtain COR approval for any post-installed anchors in lieu of cast-in-place anchors. Design codes include the 2024 International Building Code, ANSI/ASCE 7-16, ACI 318-19, and VA Structural Design Manual PG-18-10.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Wage Determination.txt | TXT text file | |
| 629-25-104 Emergency Dept Suicide Risk Mitigation Fence SOW.pdf | ||
| 36C25626R0117 EXHIBIT A Past Performance Relevancy.docx | DOCX document | |
| 36C25626R0117 EXHIBIT C Subcontractor Information Consent.docx | DOCX document | |
| 36C25626R0117.docx | DOCX document | |
| 2515 VA New Orleans ED Fence - SPECIFICATIONS - BD revised 13 July 2026.pdf | ||
| 36C25626R0117 EXHIBIT D Safety Form.docx | DOCX document | |
| DOL Wage Determination LA20260041.pdf | ||
| 36C25626R0117 EXHIBIT E Surety Form.docx | DOCX document | |
| 36C25626R0117 EXHIBIT F Request for Information.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INDEX OF DRAWINGS
GI001
SHEET
NO.
DRAWING TITLE
GENERAL
GI002
ARCHITECTURAL
SHEET
NO.
COVER SHEET
LEGENDS, ABBREVIATIONS AND NOTES
PARTIAL FLOOR PLAN - SECOND LEVEL NORTH ENDAE101
ED DRIVE SUICIDE MITIGATION
PROJECT NUMBER: 629-25-104
BID DOCUMENTS
SOUTHEAST LOUSIANA VETERANS HEALTH CARE SYSTEM
2400 CANAL ST, NEW ORLEANS, LA 70119
LOCATION MAP
NOT TO SCALE
AREA MAP
NOT TO SCALE
PROJECT LOCATION
PROJECT LOCATION
TRUE
NORTH
PLAN
NORTH
PARTIAL FLOOR PLAN - SECOND LEVEL SOUTH ENDAE102
EXTERIOR ELEVATIONS - WEST AND NORTHAE201
EXTERIOR ELEVATIONS - EAST AND SOUTHAE202
INTERIOR ELEVATIONSAE451
DETAILSAE502
TRUE
NORTH
PLAN
NORTH
DRAWING TITLE
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
COVER SHEET
GI001
ARCHITECTURAL ABBREVIATIONSARCHITECTURAL LEGEND
GENERAL ARCHITECTURAL NOTES
GENERAL PROJECT NOTES
A
GA4
A301
A201
A401
ROOM
NAME
+ 0'-6"
F.E.C.
AIR CONDITIONING
ACOUSTICAL CEILING TILE
ABOVE FINISH FLOOR
ALUMINUM
BATT INSULATION
BOTTOM OF
CEMENTITIOUS BACKER BOARD
CEMENTITIOUS CRYSTALLINE WATERPROOFING
COLD-FORMED METAL FRAMING
CORNER GUARD
CENTERLINE
CONCRETE MASONRY UNIT
CASED OPENING
COMMUNICATION
CONCRETE
SEALED CONCRETE
CONTINUOUS
CONTRACTING OFFICER'S REPRESENTATIVE
CERAMIC TILE
CERAMIC TILE BASE
CARPET
DIAMETER
EXPANSION JOINT
ELECTRICAL
EPOXY FLOORING
EXPOSED STRUCTURE
ET CETERA
EXISTING
EXPOSED
FACTORY FINISH
FLOOR DRAIN
FIRE EXTINGUISHER CABINET
FIRE HOSE CABINET
FINISHED FLOOR
FINISH
FLOOR
FACE OF
FIELD VERIFY
FABRIC WALLCOVERING
GAGE
GRANITE
GYPSUM (WALL) BOARD
HANDICAPPED
HOLLOW METAL
HANDRAIL
HEATING VENTILATION AND AIR-CONDITIONING
MATERIAL
MAXIMUM
MECHANICAL
MANUFACTURER
MINIMUM
MASONRY OPENING
METAL
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OPPOSITE HAND
PLASTER
PLASTIC LAMINATE
PORCELAIN TILE
PAIR
PAINT
QUARRY TILE
RESILIENT BASE
REFRIGERATOR
REQUIRED
RESINOUS FLOORING
RESINOUS EPOXY WALL-CEILING
ROUGH OPENING
RUBBER FLOORING
RECESSED PAPER HOLDER
SEALED HIGH BUILD GLAZED COATING
SOLID CORE WOOD
SIMILAR
SPECIAL FACED
STAINLESS STEEL
STEEL
SUBSTRATE
SHEET VINYL
SOLID VINYL TILE
TELEPHONE
TOP OF
TYPICAL
UNLESS NOTED OTHERWISE
VINYL COMPOSITION TILE
VINYL WALL COVERING
WALL COVERING
WALL PROTECTION
WOOD
WELDED SEAM SHEET FLOORING
AC
AT
AFF
AL
BATT
BO
CBB
CCW
CFMF
CG
C
CMU
CO
COMM
CONC
SCONC
CONT
COR
CT
CTB
CP
DIA
EJ
ELEC
EPY
ES
ETC
EXIST
EXP
FAC FIN
FD
FEC
FHC
FF
FIN
FLR
FO
FV
FWC
GA
GRA
GYP BD/GWB
HC
HM
HR
HVAC
MATL
MAX
MECH
MFR
MIN
MO
MTL
NIC
NTS
OC
OH
PLS
PL
PT
PR
P
QT
RB
REF
REQ'D
RES
RES-W
RO
RF
RPH
SC
SCW
SIM
SP
SS
STL
SUBS
SV
SVT
TELE
TO
TYP
UNO
VCT
VWC
WC
WP
WD
WSF
L
FIRE EXTINGUISHER CABINET
ROOM NAME AND NUMBER
DOOR NUMBER
KEY NOTE
WINDOW TYPE
PARTITION TYPE
DETAIL CALLOUT
DETAIL NUMBER
SHEET WHERE DETAIL IS DRAWN
SECTION CALLOUT
VERTICAL ELEVATION
COLUMN CENTERLINE DESIGNATION
DEMOLITION KEY NOTE
DETAIL NUMBER
SHEET WHERE DETAIL IS DRAWN
INTERIOR FENCE ELEVATION CALLOUT
DETAIL NUMBER
SHEET WHERE DETAIL IS DRAWN
CARD READERCR
HIGH-PRESSURE LAMINATEHPL
LUXURY VINYL TILELVT
EDGE OF DECKEOD
DOWNSPOUTDS
CONTROL JOINTCJ
DRINKING FOUNTAINDF
FIRE RETARDANT TREATEDFRT
EXTERIOR INSULATION FINISHING SYSTEMEIFS
WATER RESISTANTWR
J1
SECTION CUT
HEAD/JAMB/SILL DETAIL NUMBER EQUALEQ
CARPET TILECPT
REFLECTED CEILING PLANRCP
SOLID SURFACE MATERIALSSM
X1045 EQUIPMENT JSN NUMBER
ALUMINUM COMPOSITE METAL PANELSACMP
A. DIMENSIONS, UNLESS OTHERWISE INDICATED, ARE TO:
• FACE OF EXISTING WALL SURFACE
• FACE OF MASONRY
• FACE OF WALL STUDS
• TOP OF SLAB
• TOP OF MASONRY
B. COORDINATE WITH ALL DISCIPLINES DRAWINGS FOR ADDITIONAL REQUIREMENTS.
COORDINATE OPENINGS IN SLABS, ROOF, AND WALLS. WHERE HOLES IN EXISTING WALLS
AND SLABS ARE CREATED FOR PENETRATIONS, COORDINATE SIZE AND LOCATION. PATCH
HOLES CAUSED BY THE REMOVAL OF EQUIPMENT, PIPING, CONDUIT, DUCT, GRILLES, ETC.
WITH MATERIALS MATCHING EXISTING SLAB OR WALL IN STRUCTURE, MATERIAL,
THICKNESS, ALIGNMENT, GRADES, AND QUALITY.
C. `PROVIDE' IS DEFINED AS PROVIDING MATERIALS, DELIVERY, STORAGE, HANDLING,
INSTALLATION, ADJUSTMENT, AND CLEANING FOR THE ITEM INDICATED.
D. SKIM COAT ALL DAMAGED EXISTING WALL SURFACES THAT REQUIRE PAINTING.
E. REMOVE COMPLETELY ALL MATERIALS AS INDICATED ON THE DRAWINGS AND AS
REQUIRED FOR CONSTRUCTION. EDGES AND FACES OF DEMOLISHED AREAS SHALL BE
REPAIRED TO ACCEPT NEAT INSTALLATION OF CONSTRUCTION OR FINISHES. WHERE
EXISTING MATERIALS ARE TO BE REPLACED (WALLS, INSULATION, FLOORING, ETC.)
EXISTING MATERIALS, ADHESIVES, ETC. SHALL BE REMOVED AND EXPOSED SURFACES
SHALL BE PREPARED AS INDICATED OR SPECIFIED PRIOR TO INSTALLATION OF
MATERIALS.
F. PREVENT DAMAGE TO MATERIALS AND FINISHES TO REMAIN. REPAIR DAMAGES FROM
CONSTRUCTION ACTIVITIES TO EXISTING ITEMS TO REMAIN, AT NO ADDITIONAL COST
WHERE SUCH EXPOSED MATERIALS OR FINISHES TO REMAIN ARE DAMAGED.
A. THE CONTRACTOR SHALL BE PREPARED TO STOP ANY WORK AND CLEAN UP THE WORK AREA
AS DIRECTED IN MEDICAL SITUATIONS REQUIRING SUCH ACTION.
B. THE CONTRACTOR SHALL NOT ORDER OR INSTALL ANY MATERIALS OR EQUIPMENT UNTIL
SUBMITTALS FOR SUCH HAVE BEEN APPROVED.
C. ALL TOOLS AND MATERIALS USED IN THIS PROJECT SHALL BE PROPERLY SECURED AT ALL
TIMES BY THE CONTRACTOR TO PREVENT THE POSSIBILITY OF ANY OF THESE TOOLS BEING A
HAZARD TO PATIENTS, VISITORS AND STAFF.
D. THE CONTRACTOR WILL BE RESPONSIBLE FOR ACQUIRING I.D. BADGES FOR EACH MEMBER OF
HIS WORK FORCE. VALID FORMS OF I.D. ARE REQUIRED TO RECEIVE BADGES. COORDINATE
WITH COR.
E. THE CONTRACTOR, AT HIS EXPENSE, WILL BE RESPONSIBLE FOR TRAINING EACH MEMBER OF
HIS WORK FORCE ON VA POLICIES FOR ON-SITE WORK BEFORE ANY MEMBER WILL BE
ALLOWED TO PERFORM WORK ON VA PREMISES.
F. ABSOLUTELY NO VA TOOLS, MATERIALS OR EQUIPMENT WILL BE LOANED OR GIVEN BY THE VA
TO ANY MEMBER OF THE CONTRACTOR'S WORK FORCE AT ANY TIME.
G. ANY SMOKE DETECTORS HAVING ANY POTENTIAL FOR EXPOSURE TO CONSTRUCTION SMOKE,
DUST AND DEBRIS SHALL BE SUITABLY PROTECTED TO PREVENT ACCIDENTAL ALARM DURING
CONSTRUCTION. ALL SUCH ACTION MUST BE FIRST COORDINATED AND CLEARED WITH THE
COR AND THE VA SAFETY OFFICER. ALL FUNCTIONAL FIRE ALARM DEVICES SHALL BE ACTIVE
WHENEVER THE CONTRACTOR'S FORCES ARE NOT PRESENT IN THE WORK AREA.
H. THE CONTRACTOR MUST PROVIDE WRITTEN FIRE SAFETY CHECKLIST AT THE END OF EVERY
WORK DAY TO THE COR CERTIFYING THAT ALL WORK AREAS HAVE BEEN SURVEYED AND
FOUND TO BE SECURE, SAFE AND FREE OF ANY FLAMMABLE LIQUIDS.
I. CONTRACTOR SHALL COORDINATE ONLY WITH THE COR AND CONTRACTING OFFICER.
J. SEE SPECIFICATIONS SECTIONS 01 00 00 AND 01 35 26 FOR INTERIM LIFE SAFETY MEASURES.
K. ALL FINISH COLORS TO BE SELECTED BY COR/ VA INTERIOR DESIGNER WHERE NOT
OTHERWISE INDICATED. CONTRACTOR SHALL SUBMIT COLORS FROM THE MANUFACTURER'S
FULL RANGE OF COLORS.
L. THE CONTRACTOR SHALL NOT OPERATE ANY EXISTING VA EQUIPMENT WITHOUT
AUTHORIZATION FROM VAMC ENGINEERING SERVICE UNLESS AN EMERGENCY SITUATION
OCCURS.
M. CONTRACTOR SHALL PROVIDE AND MAINTAIN ALL REQUIRED EXIT LIGHTING AND SIGNAGE
REQUIRED FOR EGRESS WITHIN AND ADJACENT TO THE PROJECT AREA DURING
PERFORMANCE OF THE WORK.
N. INDICATED EXISTING CONDITIONS ARE BASED UPON LIMITED FIELD INVESTIGATION AND DID
NOT INCLUDE DESTRUCTIVE INVESTIGATION OR TESTING. CONTRACTOR SHALL VERIFY ALL
EXISTING CONDITIONS INCLUDING DIMENSIONS OF THE INSTALLED CONSTRUCTION PRIOR TO
COMMENCING WITH THE WORK. IF DISCREPANCIES ARE DISCOVERED, THE CONTRACTOR
SHALL NOTIFY THE COR FOR INTERPRETATION AND DIRECTION PRIOR TO PROCEEDING WITH
THE WORK.
O. COORDINATE WORK WITH EQUIPMENT SUPPLIER/ INSTALLER CONTRACTED SEPARATELY WITH
THE GOVERNMENT.
P. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST TO MAINTAIN LEVEL LINE
ALONG TOP OF FENCE.
Q. FIELD VERIFY EXISTING CONDITIONS. GROUT THICKNESS UNDER FENCE TUBE FRAME BASE
PLATES TO BE 1/2" MINIMUM, 1-1/2" MAXIMUM.
A ACCESSORY TYPE
DESIGN CODES
1.01 2024 INTERNATIONAL BUILDING CODE (IBC) AS MODIFIED BY:
A. ANSI/ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES
B. VA STRUCTURAL DESIGN MANUAL PG-18-10, JULY 1, 2023
C. VA SEISMIC DESIGN REQUIREMENTS H-18-8, 2020 EDITION
1.02 AMERICAN CONCRETE INSTITUTE (ACI)
A. ACI 318-19, BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
DESIGN LOADS
1.01 DESIGN LOADS ARE AS FOLLOWS:
A. FLOOR:
1. DEAD LOADS:
a. SELF WEIGHT OF MATERIALS
2. LIVE LOADS:
a. SEE ORIGINAL CONSTRUCTION DOCUMENTS
B. OTHER LOADS:
1. ANTI-CLIMB FENCING:
a. DESIGN ANTI-CLIMB FENCE SYSTEM TO RESIST THE FOLLOWING LIVE LOADS
IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE REQUIREMENTS.
• FENCE PANELS SHALL BE CAPABLE OF SUPPORTING A 400 LB. (882 KG)
VERTICAL LOAD APPLIED AT MIDSPAN WITHOUT PERMANENT
DEFORMATION.
• HORIZONTAL LOAD OF 5 PSF, OR 50 LBS OVER A 12 IN X 12 IN AREA NOT
CONCURRENTLY
• ICE LOADS DUE TO FREEZING RAIN: SEE ASCE 7
• WIND LOAD: SEE ASCE 7 AND CRITERIA BELOW
• WIND ON ICE-COVERED STRUCTURES: SEE ASCE 7 AND CRITERIA BELOW
• SEISMIC: WHEN REQUIRED, SEE EARTHQUAKE CRITERIA BELOW
C. WIND LOADS:
1. ULTIMATE DESIGN WIND SPEED Vult = 153 MPH
2. IMPORTANCE FACTOR Iw = 1.0
3. RISK CATEGORY IV
4. WIND EXPOSURE = B
D. SNOW LOADS:
1. GROUND SNOW LOAD, Pg: 10 psf
E. EARTHQUAKE LOADS:
1. SEISMIC IMPORTANCE FACTOR I = 1.5
2. RISK CATEGORY = IV
3. MAPPED SPECTRAL RESPONSE ACCELERATIONS
a. Ss = 0.11g
b. S1 = 0.06g
4. SITE CLASS = D
5. SPECTRAL RESPONSE COEFFICIENTS (FOR SITE CLASS D)
a. Sds = 0.098
b. Sd1 = 0.066
6. SEISMIC DESIGN CATEGORY = C
7. BASIC SEISMIC-FORCE-RESISTING SYSTEM:
a. BUILDING FRAME SYSTEM
• ORDINARY REINFORCED CONCRETE MOMENT FRAMES
8. ANALYSIS PROCEDURE - EQUIVALENT LATERAL FORCE PROCEDURE
1.02 DEFLECTION CRITERIA: REFER TO TABLE 1604.3 FOR DEFLECTION LIMITS.
GENERAL STRUCTURAL NOTES
EXISTING CONDITIONS
1.01 AS WITH ANY WORK AFFECTING EXISTING CONSTRUCTION, UNFORESEEN CONDITIONS ARE UNAVOIDABLE WITHOUT DEMOLISHING OTHERWISE SERVICEABLE CONSTRUCTION, DISRUPTING OCCUPIED OPERATIONS AND INCURRING SIGNIFICANT COST FOR CLOSE UP EXAMINATION AND NON-DESTRUCTIVE TESTING DURING
THE DESIGN STAGE.
1.02 WITH THE PASSAGE OF TIME SINCE THE CREATION OF AS-BUILT DRAWINGS AND/OR THE DESIGNERS SURVEY, BOTH CONCEALED AND VISIBLE CONDITIONS MAY HAVE CHANGED DUE TO ALTERATIONS, ADDITIONS, RENOVATIONS AND DETERIORATION.
1.03 PRIOR TO THE COMMENCEMENT OF ANY WORK IN PREPARATION OF CONSTRUCTION RELATED ACTIVITIES, INCLUDING BUT NOT LIMITED TO SHOP DRAWING PREPARATION, ALL BURIED, EMBEDDED, AND CONCEALED ITEMS LIKELY TO BE ENCOUNTERED DURING CONSTRUCTION SHALL BE LOCATED AND MARKED ON THE SURFACE. THIS WORK SHALL BE ACCOMPLISHED BY DESTRUCTIVE AND/OR NON-DESTRUCTIVE MEANS WITHOUT IMPAIRING THE STRUCTURAL INTEGRITY OF THE ASSOCIATED MEMBERS. SHORING AS REQUIRED SHALL BE DESIGNED BY A PROFESSIONAL STRUCTURAL ENGINEER, LICENSED IN THE STATE OF THE
PROJECT, AND FURNISHED AND INSTALLED AT NO ADDITIONAL COST.
1.04 EXISTING CONDITIONS THAT INTERFERE OR OTHERWISE AFFECT THE DESIGN, CONSTRUCTION OR SERVICEABILITY OF THE WORK SHALL BE BROUGHT TO THE ATTENTION OF THE COR, INCLUDING PLAN AND SECTION SKETCHES, IMMEDIATELY FOR RESOLUTION. THE CONTRACTOR SHALL ALLOW TWO CALENDAR WEEKS IN THE SCHEDULE FOR DESIGN RESOLUTION THE INTERFERENCE AFTER ALL INFORMATION ABOUT THE INTERFERENCE, INCLUDING SIZE, LOCATION AND FUNCTION OF THE EMBEDMENT, HAS BEEN RECEIVED
BY THE STRUCTURAL ENGINEER.
ANTI-CLIMB FENCE DESIGN
1.01 THE VENDOR SHALL SUPPLY A TOTAL ARCHITECTURAL FENCE SYSTEM INCORPORATING AN ANTI-CLIMB DESIGN THAT INCLUDES ALL COMPONENTS (I.E. BRACKETS, PANELS, POSTS, AND HARDWARE) AS
REQUIRED FOR A COMPLETE INSTALLATION.
1.02 ENGINEERING RESPONSIBILITY: ENGAGE A FABRICATOR WHO ASSUMES UNDIVIDED RESPONSIBILITY FOR ENGINEERING FENCING, AND ALL ASSOCIATED CONNECTIONS TO NEW AND EXISTING STRUCTURE NOT SHOWN IN THESE DRAWINGS BY EMPLOYING A QUALIFIED PROFESSIONAL ENGINEER TO PREPARE AND
SEAL DESIGN CALCULATIONS, SHOP DRAWINGS, AND OTHER STRUCTURAL DATA.
1.03 HORIZONTAL MEMBERS THAT ARE ACCESSIBLE FROM THE OCCUPIED SIDE OF FENCE AND MIGHT BE USED AS FOOT- OR HAND-HOLDS SHALL EITHER BE SPACED AT A MINIMUM 8 FEET (2400 MM) APART OR DESIGNED
WITH ANTI-CLIMB FEATURES.
1.04 DESIGN FRAMING SYSTEMS TO PROVIDE FOR MOVEMENT OF FRAMING MEMBERS WITHOUT DAMAGE OR OVERSTRESSING, FABRIC FAILURE, CONNECTION FAILURE, UNDUE STRAIN ON FASTENERS AND ANCHORS, OR OTHER DETRIMENTAL EFFECTS WHEN SUBJECT TO BUILDING MOVEMENT, INCLUDING DRIFT AND DEFLECTION, OR THERMAL LOADS CAUSED BY A MAXIMUM AMBIENT TEMPERATURE CHANGE (RANGE) OF
67 DEGREES C (120 DEGREES F).
1.05 ALL SECTIONS AND PIECES OF THE FENCE MATERIAL, RAILS, FRAMING, ETC. WILL BE HOT DIP GALVANIZED.
THE GALVANIZING PROCESS MUST MEET ASTM A123/A123M STANDARDS. GALVANIZING COATING SHALL BE FOLLOWED BY A ZINC PHOSPHATE COAT, AND EPOXY POWDER COAT, AND A POLYESTER COLOR COAT.
SEE ARCHITECTURAL FOR ANY ADDITIONAL FINISH OR COLOR REQUIREMENTS.
1.06 FENCE PANELS WILL BE PROVIDED SO THAT LIMITED FIELD CUTTING AND FIELD FINISH PATCHING WORK IS REQUIRED. SUPPLY ADDITIONAL GALVANIZING MATERIAL FOR TOUCHING UP THE FENCE SYSTEM ON SITE.
ENSURE ALL AREAS AND COMPONENTS OF THE FENCE AND GATES ARE PROPERLY COATED.
1.07 EVERY POST OR OPENING IN THE TOP OF THE FENCE STRUCTURE WILL BE SEALED WITH A UV-STABILIZED
POLYMER POST CAP.
1.08 RAILS SHALL BE CONFIGURED AS TO ALLOW USE AS A RACEWAY FOR COMMUNICATION OR VIDEO
CABLING.
1.09 PROVIDE GUARDS AS REQUIRED TO PREVENT BEAMS, COLUMNS, OR OTHER HORIZONTAL PROJECTIONS
TO BE USED AS STEPS OR HAND-HOLDS.
1.10 BEFORE ANY CONCRETE DRILLING, LOCATE AND AVOID ALL REINFORCING, CONDUIT, OR OTHER ITEMS EMBEDDED IN CONCRETE BY GPR OR OTHER NON-DESTRUCTIVE MEANS AS APPROVED BY THE COR.
POST-INSTALLED ANCHORS
1.01 POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE COR PRIOR TO INSTALLING POST- INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST-IN-PLACE ANCHORS. CARE SHALL BE TAKEN IN PLACING POST-INSTALLED ANCHORS TO AVOID CONFLICTS WITH EXISTING REBAR. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS.
SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE COR ALONG WITH CALCULATIONS THAT ARE PREPARED & SEALED BY A
REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL DEMONSTRATE THAT THE
SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERTINENT EQUIVALENT PERFORMANCE VALUES
(MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR
STANDARD(S) AS REQUIRED BY THE BUILDING CODE.
1.02 CONCRETE ANCHORS
A. MECHANICAL ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED
AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC-ES AC193. PRE-APPROVED
MECHANICAL ANCHOR MANUFACTURERS:
1. SIMPSON STRONG-TIE ANCHORING SYSTEMS
2. HILTI
3. POWERS
B. ADHESIVE ANCHORS FOR USE IN CRACKED AND UNCRACKED CONCRETE SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC-ES AC308. PRE-APPROVED ADHESIVE ANCHOR
MANUFACTURERS
1. SIMPSON STRONG-TIE ANCHORING SYSTEMS
2. HILTI
3. POWERS
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
LEGENDS, ABBREVIATIONS AND NOTES
GI002
DN
A
M
B
U
L
A
N
C
E
O N L Y
P A T I E N T
D R O P - O F F
N
A
M
B
U
L
A
N
C
E
O N L YN
A
M
B
U
L
A
N
C
2E250
2E252
2D255
2E254
2E256
2E258
2E258A
2E258B
2E182
2E183
2E178
2E180
2E181
2E176
90SF
130SF
501SF
821SF
112SF
149SF
105SF
296SF
358SF
HVC
COPY/WORK
AOD
OFFICE
DECONTAM
CONSULT
NURSE
MANAGER
ENTRANCE
VESTIBULE
ENTRANCE
VESTIBULE
CORR
2D-C12
ENTRANCE
VESTIBULE
2E184
ELEV
DP-10
ELEV
DP-09
2E-C12
CORR
2E182
2E181
2E -C
2E183
E- E2
-1
.2
2E180
2E
2E181
/4
T .I
A
M
B
U
L
A
N
C
E
O N
L Y
N L
Y
FLOOR PLAN LEGEND
EXISTING CONSTRUCTION TO REMAIN
CONSTRUCTION
FLOOR PLAN GENERAL NOTES
A. PATCH EXISTING RETAINED CONSTRUCTION ADJACENT TO INSTALLED CONSTRUCTION.
B. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS.
FLOOR MOUNTED FENCE WITH WIRE MESH.
FLOOR PLAN KEY NOTES
GROUNDING ROD, SEE SHEET AE502 FOR DETAILS.2
AE201
ed5 ed1 ed4 ed3 ed2 edDedF edC edAedB
FI
E
LD
V
E R
IF
Y
2'
4"
FIELD VERIFY
24' - 0"
FIELD VERIFY
56' - 6 1/8"
AE4515
AE451
AE502
MATCHLINE
AE101
AE502
Sim
AE502
Sim
AE451
AE4518
AE201
AE451
2 2
PROJECT AREA
KEY PLAN
NTS
MATCHLINE
ed1 edA
AE451
19' - 10" +/-
6" 14'-0"1
1'
3" 3'
8"
3'
4"
AE451
4"
6" 14'-0"
AE451 12
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
PARTIAL FLOOR PLAN - 2ND LEVEL NORTH END
AE101
TRUE
NORTH
PLAN
NORTH
0' 4' 8' 16' 24'
SCALE: 1/8" = 1' - 0"
1/8" = 1'-0"AE101
1 2ND LEVEL - NORTH END
1/4" = 1'-0"AE101
2 ENLARGED PLAN - STAIR 2ND LEVEL NORTH END
E
O N L YN
A
M
B
U
L
A
N
C
E
O N L YN
2E260
2E262
2E258B
2F317
2F315
2F313
2F311
2F309 2F307
2E175
2E174
2E176
358SF
227SF
24SF
294SF
120SF
138SF
118SF
279SF
236SF
F E
C
MULTI-PURPOSE
EC
ENTRANCE
VESTIBULE
STAIR
STF-04
EQUIP
CALIB
(NM)
2F180
RAD
RES
CONF
2F178
LINEN
ROOM
2F181
PACS
ADMIN
2F183A
BIO-MED
WORK
2F179
RAD
WASTE
2F177
DN
UP
2E174
2E175
2F
2F180
2F
2F181
2F183
2F179
ST
P
A
M
B
U
L
A
N
C
E
O N
L Y
N
A
M
B
U
L
A
N
C
E
O N
L Y
N
A
M
B
U
L
A
N
C
E
O N
L Y
N
A
M
B
U
L
A
N
C
E
O N
L Y
N
FLOOR PLAN LEGEND
EXISTING CONSTRUCTION TO REMAIN
CONSTRUCTION
FLOOR PLAN GENERAL NOTES
A. PATCH EXISTING RETAINED CONSTRUCTION ADJACENT TO INSTALLED CONSTRUCTION.
B. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS.
FLOOR MOUNTED FENCE WITH WIRE MESH.
FLOOR PLAN KEY NOTES
GROUNDING ROD, SEE SHEET AE502 FOR DETAILS.2
AE202
AE202
ed5 ed9 ed10 ed6 ed7 ed8 edDedF edC edA edBedGedHedIedJedKedL edB1edB2
FIELD VERIFY
111' - 8"
FI
E
LD
V
E R
IF
Y
AE451 2
AE451
AE451
FI
E
LD
V
E R
IF
Y
/4
FIELD VERIFY
178' - 2 1/4"
FIELD VERIFY
15' - 1"
F.V.
4' - 0"
F.V.
3' - 2"
MATCHLINE
AE201
AE451
AE201
AE451
2 2
2 2 2
AE451
PROJECT AREA
KEY PLAN
NTS
MATCHLINE
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
PARTIAL FLOOR PLAN - 2ND LEVEL SOUTH END
AE102
TRUE
NORTH
PLAN
NORTH
0' 4' 8' 16' 24'
SCALE: 1/8" = 1' - 0"
1/8" = 1'-0"AE102
1 2ND LEVEL - SOUTH END
LEVEL 1
0"
LEVEL 2
18'-10"
LEVEL 3
38'-0"
LEVEL 1 i 11'-8"
LEVEL 2 i 30'-8"
LEVEL 2 D
18'-4" ed5ed1 ed9 ed10ed6 ed7 ed8ed4ed3ed2 27 28293031323334353637
WIRE MESH
FENCE
LEVEL 1
0"
LEVEL 2
18'-10"
LEVEL 3
38'-0"
LEVEL 1 i 11'-8"
LEVEL 2 i 30'-8"
LEVEL 2 D
18'-4" edD edFedCedB edG edH edI edJ edK edLedB1 edB2
WIRE MESH
FENCE
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
EXTERIOR ELEVATIONS - WEST AND NORTH
AE201
0' 4' 8' 16' 24'
SCALE: 1/8" = 1' - 0"
1/8" = 1'-0"AE201
1 WEST ELEVATION
1/8" = 1'-0"AE201
2 NORTH ELEVATION
LEVEL 1
0"
LEVEL 2
18'-10"
LEVEL 3
38'-0"
LEVEL 1 i 11'-8"
LEVEL 2 i 30'-8"
LEVEL 2 D
18'-4" ed9ed10 ed7ed82728
WIRE MESH FENCE
LEVEL 1
0"
LEVEL 2
18'-10"
LEVEL 3
38'-0"
LEVEL 1 i 11'-8"
LEVEL 2 i 30'-8"
LEVEL 2 D
18'-4" edDedF edC edAedBedGedHedIedJedKedL edB1edB2
WIRE MESH FENCE
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
EXTERIOR ELEVATIONS - EAST AND SOUTH
AE202
0' 4' 8' 16' 24'
SCALE: 1/8" = 1' - 0"
1/8" = 1'-0"AE202
1 EAST ELEVATION
1/8" = 1'-0"AE202
2 SOUTH ELEVATION
AE502
AE502
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
AE502
Sim
AE502
TYP.
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
AE502
TYP.
AE502
Sim
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
AE502
Sim
AE502
Sim
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
ACCESS PANEL FOR
LIGHT POLE BEYOND
AE502
AE502
Sim
LEVEL 1
0"
LEVEL 2
18'-10"
6' -1
0" 6'
-1 0"
5' -2
3'
-8
5' -4
3'-6" 3'-6" 3'-6" 3'-6"
'-1
0"
14'-0" 6"
7'-0"7'-0"
AE502
1'-4"5'-8"
'-8
5'
-2
LEVEL 1
0"
LEVEL 2
18'-10"
'-1
0"
14'-0"
3'-6" 3'-6" 3'-6" 3'-6"
4' -8
/2
4'
-8
/2
4' -8
/2
4'
-8
/2
AE502
AE502
TYP.
AE502
TYP.
3'-11" 3'-8"
8' -9
AE502
TYP.
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
INTERIOR ELEVATIONS
AE451
0' 4' 8' 16' 24'
SCALE: 1/8" = 1' - 0"
1/8" = 1'-0"AE451
1 INTERIOR ELEVATION 1
1/8" = 1'-0"AE451
5 INTERIOR ELEVATION 3
1/8" = 1'-0"AE451
2 INTERIOR ELEVATION 2
1/8" = 1'-0"AE451
7 INTERIOR ELEVATION 4
1/8" = 1'-0"AE451
10 INTERIOR ELEVATION 5
1/8" = 1'-0"AE451
14 INTERIOR ELEVATION AT STAIRS
1/8" = 1'-0"AE451
13 INTERIOR ELEVATION AT STAIRS
1/8" = 1'-0"AE451
3 INTERIOR ELEVATION 6
1/8" = 1'-0"AE451
4 INTERIOR ELEVATION 7
1/8" = 1'-0"AE451
6 INTERIOR ELEVATION 8
1/8" = 1'-0"AE451
8 INTERIOR ELEVATION 9
1/8" = 1'-0"AE451
11 INTERIOR ELEVATION 10
1/8" = 1'-0"AE451
12 INTERIOR ELEVATION 11
1/8" = 1'-0"AE451
9 INTERIOR ELEVATION 12
9'
0" 3' - 9"
4"4"
8" 5'
0"
9'
0"
3' - 9"
AE502
STAINLESS STEEL
WIRE MESH
EXISTING
CONCRETE WALL
AE502
AE502
VENDOR-DESIGNED STEEL BASE
PLATE ON MIN 1/2", MAX 1-1/2" GROUT
AND CORROSION RESISTANT
FASTENERS
MIN 2" SPACE
TUBE FRAME
VERTICALS TO
ALIGN WITH THE
VERTICALS FROM
INFILL PANELS
BELOW, MAX. 4'-0"
O.C., SEE
ELEVATIONS
VENDOR-DESIGNED,
POWDER COATED
CARBON STEEL, MIN" 2"
SQUARE TUBE FRAME
VENDOR-DESIGNED WELDED PLATE
AT TOP OF POWDER COATED
CARBON STEEL TUBE VERTICALS AS
NEEDED TO PREVENT WATER
PENETRATION (TYP.)
ANCHOR VERTICALS TO INSIDE OF
EXISTING CONCRETE WALL, 6"
BELOW TOP OF WALL AND 6" ABOVE
FLOOR SLAB USING CORROSION
RESISTANT FASTENERS
AE502
VENDOR-DESIGNED
MIN 2" TUBE FRAME
WIRE MESH
COVER PLATE
6"
VENDOR-DESIGNED
MIN 2" TUBE FRAME
PLATE
COVER PLATE
WIRE MESH
1' - 0"
1'
0"
EXISTING CONCRETE WALL
VENDOR-DESIGNED,
POWDER COATED
CARBON STEEL, MIN 2"
SQUARE TUBE FRAME
VENDOR-DESIGNED STEEL
BASE PLATE ON MIN 1/2", MAX
1-1/2" GROUT AND CORROSION
RESISTANT FASTENERS
MIN 2" SPACE TUBE FRAME
VERTICALS TO ALIGN WITH
THE VERTICALS FROM INFILL
PANELS BELOW, MAX. 4'-0"
O.C., SEE ELEVATIONS
WALL FOOTING BEYOND
BACK FACE OF WALL PIER
GRADE LEVEL
WALL
COLUMN PIER
FOOTING STEEL
3/4" CONDUIT
GROUND ROD /
TEST WELL
CONCRETE SLAB
BOLTED CONNECTION TO BARE METAL
METAL FENCE
1/0 CU CABLE
1/0 CU CABLE
GROUNDING BUSHING
GROUNDING BUSHING
8' (MAX)
3' (MIN)
(M
IN
TO IMPROVE SYSTEM RESISTANCE, ERICO GEM MAY BE USED AS A BACKFILL
MATERIAL IN AN AUGURED HOLE. PROVIDE GROUND RODS TO ACHIEVE MAXIMUM
10 OHMS RESISTANCE.
1"x4" SLOT IN
12" PVC PIPE
GROUND CONDUCTOR, SIZE
AS NOTED ON PLANS
DRIVEN COPPER CLAD
GROUND ROD 5/8" x 10'
(SEE NOTE)
NOTE:
TEST WELL AND COVER
CADWELD TYPE GT
CLEAN SAND FILL
#2 AWG BCW TINNED PIGTAIL
24"
30" MIN
2"
2"
12" MIN
AE502
VENDOR-DESIGNED STEEL
BASE PLATE ON MIN 1/2", MAX
1-1/2" GROUT AND CORROSION
RESISTANT FASTENERS ON
SLOPE
MIN 2" SPACE TUBE FRAME
VERTICALS TO ALIGN WITH
THE VERTICALS FROM INFILL
PANELS BELOW, MAX. 4'-0"
O.C., SEE ELEVATIONS
VENDOR-DESIGNED
MIN 2" TUBE FRAME
VENDOR-DESIGNED STEEL
BASE PLATE ON MIN 1/2",
MAX 1-1/2" GROUT AND
CORROSION RESISTANT
FASTENERS
6"
9' -6
AE502
Sim
VA FORM 08-6231
1 2 3 4 5 6 7 8 9
DATE:
Drawing Title:
Approved Project Director
Project Title:
1 2 3 4 5 6 7 8 9
BID DOCUMENTS
512 MEANS ST NW
Phase Project Number
Building Number
Drawing NumberLocation
Issue Date Checked
STAMP
STE. 400
ATLANTA, GA 30318
ARCHITECT/ENGINEER OF RECORDCONSULTANT
A
B
C
D
E
F
U.S. Department of Veterans Affairs
Office of Construction and
Facilities Management
Drawn
SV SV,ZN
629-25-104
04-09-2026REVISIONS:
A
B
C
D
E
F
ED DRIVE SUICIDE MITIGATION
NEW ORLEANS, LA
DETAILS
AE502
3/8" = 1'-0"AE502
12 TYPICAL LIGHT POLE ACCESS PANEL ELEVATION
3/8" = 1'-0"AE502
11 TYPICAL FENCING ELEVATION
3/4" = 1'-0"AE502
6 TYPICAL SCURITY FENCE SECTION
3" = 1'-0"AE502
1 SECURITY FENCE WALL ANCHOR DETAIL
3" = 1'-0"AE502
3 DETAIL INTEGRATED ANGLED RETURN
1 1/2" = 1'-0"AE502
2 TYPICAL SECURITY FENCE ANCHORAGE DETAIL - PLAN VIEW
3" = 1'-0"AE502
4 SECURITY FENCE POST FLOOR ANCHOR DETAIL
12" = 1'-0"AE502
13 GND - COLUMN GROUNDING DETAIL
12" = 1'-0"AE502
5 GND - GROUND ROD INSPECTION WELL
GROUNDING ROD NOTE:
FENCE SHALL BE GROUNDED IN ACCORDANCE WITH NEC ARTICLE
250.194. ALL CORNERS SHALL BE GROUNDED TO THE EXISTING
GROUNDING SYSTEM OR BUILDING STEEL. FIELD VERIFY EXACT
CONNECTION LOCATION. NEW GROUND TEST WELL AND GROUND ROD
SHALL BE INSTALLED AS NEEDED. FENCE GROUNDING CONNECTIONS
SHALL NOT EXCEED 150'-0" UNLESS OTHERWISE NOTED.
3/8" = 1'-0"AE502
8 TYPICAL FENCING ELEVATION ON SLOPE
3" = 1'-0"AE502
9 SECURITY FENCE POST FLOOR ANCHOR DETAIL ON SLOPE
3" = 1'-0"AE502
10 SECURITY FENCE WALL AND FLOOR ANCHOR DETAIL
GENERAL NOTE:
1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST
TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.
2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.
GENERAL NOTE:
1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST
TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.
2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.
GENERAL NOTE:
1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST
TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.
2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.
GENERAL NOTE:
1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST
TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.
2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.
GENERAL NOTE:
1. SHIMS TO BE INSTALLED AS NEEDED UNDER BASE OF FENCE POST
TO MAINTAIN LEVEL LINE ALONG TOP OF FENCE.
2. VERIFY SLOPE WITH EXISTING CONDITONS PRIOR TO FABRICATION.
GENERAL NOTE:
1. SHIMS TO BE INSTALLED AS NEEDED UNDER
BASE OF FENCE POST TO MAINTAIN LEVEL
LINE ALONG TOP OF FENCE.
2. VERIFY SLOPE WITH EXISTING CONDITONS
PRIOR TO FABRICATION.
GENERAL NOTE:
1. SHIMS TO BE INSTALLED AS NEEDED UNDER
BASE OF FENCE POST TO MAINTAIN LEVEL
LINE ALONG TOP OF FENCE.
2. VERIFY SLOPE WITH EXISTING CONDITONS
PRIOR TO FABRICATION.
3/8" = 1'-0"AE502
7 TYPICAL FENCING ELEVATION AT SKYLIGHT WALL
| Sheets |
| AE101 - PARTIAL FLOOR PLAN - 2ND LEVEL NORTH END |
| AE102 - PARTIAL FLOOR PLAN - 2ND LEVEL SOUTH END |
| AE201 - EXTERIOR ELEVATIONS - WEST AND NORTH |
| AE202 - EXTERIOR ELEVATIONS - EAST AND SOUTH |
| AE451 - INTERIOR ELEVATIONS |
| AE502 - DETAILS |
| GI001 - COVER SHEET |
| GI002 - LEGENDS, ABBREVIATIONS AND NOTES |
File details come from the government source that posted it. Updated .