TL-3_Crash_Cushion.pdf
PDF 498 KB Posted
- Attached to
- Crash rated traffic barrier del to MN DOT
- Solicitation number
- 2000016254
- Issued by
- Morrison County, Minnesota
About this file
This document appears to be a technical specification or drawing for a TL-3 Crash Cushion product by Barrier Systems Inc. The document provides detailed part numbers, descriptions, quantities, and installation instructions for the various components that make up the TL-3 Crash Cushion system. Key details include the overall dimensions of the system, part numbers for the end panels, sliding panels, cable assemblies, energy absorbing cartridges, and required hardware such as bolts, nuts, and washers. The document also includes several detailed drawings and diagrams to illustrate the assembly and installation of the crash cushion system.
The document does not appear to be directly related to a state or local contract opportunity. It seems to be an internal technical specification or drawing provided by the manufacturer. There are no details included about a solicitation, bid process, award information, or contract terms.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| rfb_bid_attachments_crash_rated_traffice_barrier.docx | DOCX document | |
| rfb_Crash_Rated_Traffic_barrier.docx | DOCX document | |
| Crash_rated_traffic_barrier_del_to_MN_DOT.pdf | ||
| rfb_sample_contract_crash_rated_traffic_barrier.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
06/13/183777A
Tel: 888-800-3691
BARRIER SYSTEMS
180 River Road
Rio Vista, CA 94571 www.barriersystemsinc.com
06/13/18PRELIM1
* 18'-8"
23'-4 1/2"
32 5/8"
34 1/2"
23'-11 1/4"
A
A
APPROVALSA
B
C
D
A
B
C
D
1234Doc. B100108
REV ECN# DATE
APPR'D BY:
La st
S av ed b y:
ja so n.
lim ; M on d ay , A ug us t 2 7, :4 2:
A
M
SHEET 1 OF 2SCALE
TITLE
BSI-1708040-US A
REV.
6/13/2018
PROHIBITED.
6/13/2018
APPR'D DATE:
DRAWN DATE:
GAD
DRAWN BY: DPDL
DO NOT SCALE DRAWING
PERMISSION OF BARRIER SYSTEMS INC. IS
IN PART OR WHOLE WITHOUT THE WRITTEN
TOLERANCES ARE:
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES.
1/16
THE INFORMATION CONTAINED IN THIS
FRACTIONSBARRIER SYSTEMS INC. ANY REPRODUCTION
2017 BARRIER SYSTEMS INC.
DRAWING IS THE SOLE PROPERTY OF
.010.XXX =
.03 1/2
Y14.5-1994
THIRD ANGLE PROJECTION
DWG NO.
1:36 B
SIZE
DECIMAL
.XX =
ANGLES
INTERPRET DIMENSIONS AND
TOLERANCES PER ASME UNIVERSAL TAU-M TL-3
ITEM PART NO. DESCRIPTION QTY.
1 BSI-1708032-00 END PANEL MOUNT, GALVANIZED, TAU-M 4
2 BSI-1708019-00 SLIDING PANEL, GALVANIZED, TAU-M 14
3 BSI-1708030-00 END PANEL, THRIE-BEAM, GALVANIZED, TAU-M 2
4 BSI-1708018-00 GALVANIZED CABLE ANCHOR, TAU-M, PARALLEL 1
5 BSI-1707032-00 GALVANIZED CABLE GUIDE, TAU-M 12
6 BSI-1708027-00 BRACKET, DELINEATION TAU-M 1
7 BSI-1706001-00 CABLE ASSEMBLY, 7 BAY, TAU-M 2
8 BSI-2001956 C-Scr HH 3/4-10 x 3 1/2, Gr5 Geomet, PARTIALLY THREADED 4
9 BSI-2001957 C-Scr HH 1/2-13 x 3 1/4, Gr5 Geomet, PARTIALLY THREADED 48
10 B030703 MIDDLE SUPPORT ASSEMBLY 6
11 B010722 CARTRIDGE, TAU-II, TYPE B, ENERGY ABSORBING 7
12 B030704 FRONT SUPPORT 1
13 K001005 TAU-II FRONT SUPPORT LEG KIT 1
14 K001003 TAU II SLIDER KIT 14
15 2001791 WASHER SL, 1/2" STANDARD, FINISH: GEOMET 48
16 2001797 NUT HN, 1/2-13, GR5, FINISH: GEOMET 48
17 2001789 NUT HN, 3/4-10, GR5, FINISH: GEOMET 8
18 2001790 WASHER FLAT, 3/4" STD, FINISH: GEOMET 12
19 2001795 C-SCR HH, 3/4-10 X 2, GR5, FINISH: GEOMET 4
20 2001810 WASHER FLAT, 3/8" STANDARD, FINISH: GEOMET 4
21 2001811 WASHER SL, 3/8" STANDARD FINISH: GEOMET 2
22 2001809 NUT HN, 3/8-16, GR5, FINISH: GEOMET 2
23 2001816 C-SCR HH, 3/8-16 X 1 1/2, GR5 FINISH: GEOMET 2
24 BSI-1709083-00 TETHER KIT, TAU-M 1
25 BSI-1711051-00 TOW HOOK, GALVANIZED, TAU-M 4
26 BSI-1803016-00 SLIDER SHIM, GEOMET, TAU-M 28
27 BSI-1707034-00 COMPACT BACKSTOP, GALVANIZED 1
28 B011001 THREADED ANCHOR 3/4-10 X 8 1/4 Gr2 25
29 2001399 NUT HN 3/4-10 HVY A563 HD GALV 25
30 2001380 WSHR 3/4 F436 FLAT RD STRUCT 25
31 4004301 EPXY ULTBD, A22+1 NOZL 2
* NOT SHOWN
** NOT INSTALLED IN TESTS 3-30 AND 3-36
2X20
23 2X
20 2X
2X21
22 2X
DETAIL B
SCALE 1 : 10
*NOTE: ORIENTATION OF CLAMP
IS TO HAVE U-BOLT ON THE SIDE
OF THE CUT END OF WIRE ROPE.
OVERLAP WIRE ROPE
A MINIMUM OF 3 3/4"
BOTH SIDES
8X15
8X9
2X 5
16 8XDETAIL C
SCALE 1 : 10
6 PLACES
2 OF 2SCALE
A
A
B
C
D
A
B
C
D
1234Doc. B100108
SHEET1:30
B
SIZE REV.
BSI-1708040-US
DWG NO.
La st
S av ed b y:
ja so n.
lim ; M on d ay , A ug us t 2 7, :4 2:
A
M
4X4X
8 17
4X
4X
ITEM 14
SECTION A-A
SCALE 1 : 20
C
D
INSTALLATION DETAILS
SEE SECTION A-A FOR
2 14X
2X3
14X14
4X
7X 11
*SEE NOTE 4 24
4X19
4X25
7 2X
6X
28X
4X
4X
PASS THROUGH BOTTOM
C-CHANNEL OF FRONT BULKHEAD
28X, DETAIL D
SCALE 1 : 15
ITEM 26 TO BE NESTED IN PANEL SLOT.
ITEM 14 TO BOLT THROUGH ITEM 26.
FRONT BULKHEAD
PLATE NOT SHOWN
FOR CLARITY
File details come from the government source that posted it. Updated .