TESTING REQUIREMENTS HC101321QA300.pdf
PDF 66 KB Posted
- Solicitation number
- HC101321QA300
- Issued by
-
Defense Information Systems Agency
About this file
SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN A 10GB ETHERNET IP BACKBONE CIRCUIT BETWEEN HANGAR 1, TELCO ROOM, ROUTE 547, 1 LANSDOWN ROAD HANGAR 1, LAKEHURST NAWCAD, NJ 08640 AND BLDG 6910, RM C3J50, 6910 COOPER AVENUE, FT GEORGE G MEADE, MD 20755. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-83. The provisions that apply to this acquisition are identified in the DITCO Basic Agreements and Section M of the attached document. The associated North American Industrial Classification System (NAICS) code for this procurement is 517311 with a small business size standard of 1500. All quoted prices shall be identified in CLIN 0001 and applicable SLINs 0001AA, 0001AB, etc. as applicable for monthly recurring charges and CLIN 0002 and applicable SLINs 0002AA, 0002AB, etc. as applicable for non-recurring charges. CLIN/SLINs shall include item descriptions, quantities and units of measure. The requested service date and acceptance criteria are outlined in the attached inquiry. The product and service code for this telecommunications requirement is DG11. The selected company must comply with the following commercial item terms and conditions, which are incorporated herein by reference and as outlined in existing basic agreements: FAR 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition; FAR 52.212-3, Offeror Representations and Certifications - Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications if there is no existing basic agreement; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the selected clauses in paragraph (b) in the existing basic agreement. Quotes are due 2 AUG 2021, by 4:00 PM (CST) at DITCO Scott AFB, IL 62225-5406 Point of Contact(s): CASSANDRA Y. COOPER (618) 418-6862, EMAIL: CASSANDRA.Y.COOPER.CIV@MAIL MIL.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101321QA300_v1.zip | ZIP file | |
| MAPS FOR DIVERSE Vendor Block Diagram Sample and Maps.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TESTING REQUIREMENTS HC101321QA300
6. ***ATTENTION LAKEHURST LOCATION*** THIS REQUIREMENT MUST BE ENGINEERED
AND PROVISIONED TOTALLY DIVERSE END TO END TO GOVERNMENT'S SERVICE
DELIVERY POINTS (SDP'S) FROM CJON: SF30MAR215825, MEANING THAT PHYSICAL PATHS
ARE TOTALLY SEPARATE INCLUDING MAN HOLES, CONDUIT, (CENTRAL OFFICE
LOCATIONS), AND FIBER BUILDS. ADDITIONALLY AS A MINIMUM THERE MUST BE A 50
METER PHYSICAL SEPARATION FROM CJON: SF30MAR215825. 7. THE TELECOM PROVIDER
MUST PROVIDE DITCO COLOR POWERPOINT DRAWINGS FOR TECHNICAL REVIEW
SHOWING THE ROUTES FROM THE COMMERCIAL DEMARCS TO THE SUPPORTING
CENTRAL OFFICES AND/OR L. REMARKS CONTINUED: WIRING CENTERS. DRAWINGS MUST
INCLUDE SEPARATION DISTANCES BETWEEN DIVERSE REQUIREMENTS, TOTAL FIBER
MILES AND ROUND TRIP DELAY (RTD), AND FIBER ROUTES RED LINED END TO END SO
THE GOVERNMENT CAN CONFIRM PHYSICAL END TO END DIVERSITY REQUIREMENTS
ARE MET. ADDITIONALLY, THE VENDOR IS TO PROVIDE DITCO WITH DETAILED
CIRCUIT/PATH CONNECTIVITY DIAGRAMS, IN KMZ OR KML FORMAT, IDENTIFYING ALL
POINTS OF PRESENCE (POP) FOR EVALUATION AND AS A FINAL RECORD OF THE
INSTALLED PATH. THESE DIAGRAMS MUST BE PROVIDED TO DISA HQ IE16
(DISA.MEADE.IE.MBX.IE16-PROVISIONING-TEAM@MAIL.MIL) FOR HISTORICAL PURPOSES.
8. THE VENDOR MUST PROVIDE LIGHT LEVEL READINGS (SIGNAL STRENGTH IN DBM) ON
THE EXTENSION FROM COMMERCIAL POP TO THE GOVERNMENT SERVICE DELIVERY
POINT (SDP) AT THE "A" AND "Z" LOCATION PRIOR TO CIRCUIT TURN OVER TO THE
GOVERNMENT ENSURING LEVELS ARE WITHIN SPECS. LIGHT LEVELS MUST BE ADJUSTED
TO -3 TO -9 DBM. 9. THE VENDOR MUST TERMINATE 10GB ETHERNET SERVICE AT
SERVICE DELIVERY LOCATIONS, IAW UNIQUE INSTALLATION FACTORS. 10. THE VENDOR
MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO INSTALLATION AT BOTH
LOCATIONS. 11. THE VENDOR MUST CONTACT DISA GOC IP BACKBONE ENGINEERING
AND IMPLEMENTATION GROUP UPON RECEIPT OF A VALID TSO TO ESTABLISH THE
COORDINATION AND ACTIVATION PROCESS. PHONE: (C) 618-418-8627, (D) 418-8627. 12.
THE VENDOR MUST CONTACT DISA GOC TIER-II ENGINEERING 48 HOURS PRIOR TO
BEGINNING THEIR END-TO-END TESTING. PHONE: (C) 618-418-8627, (D) 418-8627. 13. THE
PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST FROM THE DROP SIDE OF
THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT
THE "A" LOCATION TO THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN THEIR
EQUIPMENT SUITE AT THE "Z" LOCATION AND MUST INCLUDE THE EXTENSION BETWEEN
THE COMMERCIAL DEMARC AND THE GOVERNMENT'S SDP. VENDOR MUST ENSURE TEST
SETS ARE PLACED AT THE DROP SIDE M. REMARKS CONTINUED: AT THE "A" LOCATION
AND AT THE "Z" LOCATION. TESTING MUST BE SATISFACTORY PRIOR TO TURN OVER TO
THE GOVERNMENT FOR ACCEPTANCE TESTING. THE VENDOR MUST TEST THE CIRCUIT
FOR 24 HOURS IAW THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR
NETWORK INTERCONNECT DEVICES STANDARD, AND AT THE COMMITTED INFORMATION
RATE (CIR) IAW ITU-T-Y.1564.
REMARKS: 1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS: (A) FIBER TERMINATION:
FRAME FORMAT: 10GB ETHERNET (OPTICAL HANDOFF-10GB ETHERNET-LAN-PHY-SINGLE
MODE FIBER), 1310NM. "SC" OR "LC" CONNECTORS AS DETERMINED BY SITE SURVEY.
NOTE: WHEN EXTENDED REACH OPTICS ARE USED THAT CHANGE THE TX/RX
WAVELENGTH OF THE OPTIC, THE VENDOR WILL NOTIFY THE GOVERNMENT 30 DAYS
PRIOR TO DELIVERY. (B) COMMITTED INFORMATION RATE (CIR): 10GB. (C) ETHERNET
FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION UNIT (MTU) OF
9000 OCTETS (BYTES) JUMBO FRAMES. (D) NO NETWORK INTERFACE UNIT, DEDICATED
PATH. (E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO
CIRCUIT. (F) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW
THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR NETWORK INTERCONNECT
DEVICES STANDARD, AND AT THE COMMITTED INFORMATION RATE (CIR) IAW ITU-T-
Y.1564. NOTE: ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU) IS EQUAL TO 9000 BYTES.
(G) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, MONTHLY PERFORMANCE OF 99.5% AVAILABILITY OR BETTER.
(H) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECEIPT OF TROUBLE. (I)
VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. (J)
VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER. (K) TELECOM PROVIDER
MUST MAINTAIN OPERATIONS, MAINTENANCE AND ADMINISTRATION MONITORING OF
ETHERNET CIRCUIT. (L) THE COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF
THE N. REMARKS CONTINUED: GOVERNMENT BY THE DISA GOC IP BACKBONE
ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. (C) 618-418-8627, (D) 418-
8627. 2. VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND
MAINTENANCE OF THE SERVICE IAW THE UNIQUE INSTALLATION FACTORS. 3. INSIDE
WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION FACTORS. 4. VENDOR MUST
COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING
ACCESS TO FACILITIES AT BOTH USER LOCATIONS. 5. VENDOR MUST CONTACT DISA GOC
TIER-II ENGINEERING 48 HOURS PRIOR TO BEGINNING THEIR END-TO-END TESTING. 6.
ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO THE DISA
GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL.
PRIMARY: (C) 618-418-9950, (D) 418-9950 TOLL FREE: 855-868-9950. 7. DD FORM 1368 WILL
BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL.
GUIDANCE ON SUBMISSION IS AVAILABLE AT
<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO
CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE RATE:
10.3125 GIGABITS/S, +- 100 PPM LINE CODE: OPTICAL 1. TEST AND ACCEPTANCE: THIS
CIRCUIT SHALL PASS A FULLY DOCUMENTED, SATISFACTORY, 72 HOUR SOAK TEST BY
DISA GOC AT SCOTT AFB, IL. PRIMARY: (C) 618-418-8627 (D) 418-8627. 2. ERROR
PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING
PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN
99.5% OR BETTER. FRAME LOSS SHALL BE EQUAL TO ZERO WHEN TESTING AT 10 GIGABIT
HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564 STANDARDS. JITTER SHALL BE
LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 10 MSEC. 3. MEAN TIME TO LOSS OF
BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER THAN 24 HOURS. 4. ROUND TRIP
DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK WILL O. REMARKS CONTINUED: BE
MEASURED IN MILLISECONDS FROM THE CUSTOMER'S SERVICE DELIVERY POINT (SDP)
SITE-A TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE
LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE
GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE
RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE
CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.
(**UNIQ INSTALL FACTORS**) (SP A) EL BLDG 120, ROOM 107 TO THE LINE SIDE OF THE
SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG HANGAR 1, SWITCH ROOM,
USING EXISTING ON-BASE SINGLE-MODE FIBER.(SP D) CH PANEL BLDG 26-2, WALLACE
ROOM. F. DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR MAINTENANCE
OF SINGLE MODE FIBER FROM DROP SIDE OF DISA IE1 PROVIDED FIBER TERMINATING
PATCH PANEL INSTALLED IN CISCO ASR-9006 ROUTER SUITE TO OPTICAL INTERFACE
CARD INSTALLED IN CISCO ROUTER. COORDINATE TYPE OF CONNECTORS. G. DISA IE4 IS
RESPONSIBLE FOR INSTALLATION AND GSM-O FOR MAINTENANCE OF CISCO ASR-9006
ROUTER, OPTICAL INTERFACE CARD BLDG 26-2, WALLACE ROOM. (** DIVERSITY INFO **)
SERVICE DIVERSITY REQUESTED; DUAL HOMING CCSD: TBD1; DUAL HOMING REMARKS:
TBD1 IS PLACE HOLDER FOR CCSD OF DIVERSE CIRCUIT.; (** ADDITIONAL PROVISIONING
INFORMATION **) (ORG ACCT) DISA (DISN IP ROUTER NETWORK BACKBONE AND
BACKBONE HOSTS)(CONUS AND OCONUS) P. REMARKS CONTINUED: FUNDING TCO APL:
DEFENSE INFORMATION SYSTEMS AGENCY (DISA) FUNDING APPROVAL: THIS
REQUIREMENT IS A BONA FIDE NEED OF FY21 AND DISA FY21 FUNDING INFORMATION IS
AVAILABLE IN DISA'S TELECOMMUNICATIONS INVENTORY AND BILLING INFORMATION
(TIBI) APPLICATION. Q. REMARKS CONTINUED: ANY ADDRESSEE ON THE (TSO) WILL
NOTIFY ALL ADDRESSEES IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES,
PROBLEMS, OR SITUATIONS WHICH MAY PREVENT OR DELAY THE IMPLEMENTATION OF
THIS TELECOMMUNICATIONS SERVICE ORDER (TSO). ALL STATIONS WILL REVIEW THE
CONFIGURATION, EQUIPMENT, CONTACT NUMBERS AND ADDRESSES CONTAINED IN THIS
(TSO) AND PROVIDE UPDATES TO ORIGINATOR OF (TSO) ANY ERRORS SO THAT
SUBSEQUENT (TSOS) MAY BE UPDATED. R. SATELLITE OBJECTION: DIVERSITY: DISA
MANDATE S. COMPLETION REPORT: DISA GOC IP B/D312-770-8627,C001-618-220-86 FOR
STATION DESIGNATED IN PARAGRAPH 2H AS CCO/CMO, FOR THIS ACTION COMPLETION
REPORTS WILL BE SUBMITTED IAW DISAC 310-130-1, CHAPTER 2 BY DISA GLOBAL IP, DSN
312-418-8627; COML 618-418-8627. ALL OTHER CCO/CMO RESPONSIBILITIES REMAIN WITH
THE DESIGNATED CCO/CMO IAW DISAC 310-70-1, CHAPTER 8. T. THIS TSO IS IN SUPPORT
OF EXERCISE/PROJECT: DISA MPLS IMPLEMENTATION PROJECT (D300) U. JUSTIFICATION
OF SERVICE REQUESTED: THIS ACTION SUPPORTS DISN IP BACKBONE IMPLEMENTATION
V. IMPLEMENTATION ASSISTANCE: IMPLEMENTATION ASSISTANCE: FOR SERVICE
ACTIVATION INQUIRIES/SCHEDULING/ASSISTANCE, NAVIGATE TO THE DISA GLOBAL
SERVICE ACTIVATIONS CUSTOMER ACCESS PORTAL:
HTTPS://DISA.DEPS.MIL/DISA/COP/GSM-O/BACKBONE/CUSTOMER%20ACCESS%2
0SITE/SITEPAGES/SAM%20CUSTOMER%20HOMEPAGE.ASPX, OR CONTACT DSN 312-418-
8627, CMCL 001-618-418-8627. FOR EMAIL SUPPORT, PLEASE CONTACT THE APPROPRIATE
TEAM BELOW: DEDICATED/NIPRNET/SIPRNET/VPN SERVICE ACTIVATIONS: EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL SIPRNET ACCESS
MIGRATION (SAM) PROJECTS (D508, D710, D806, D910): EMAIL:
DISA.SCOTT.GLOBAL.MBX.IMPACT-TEAM@MAIL.MIL FOR ALL OTHER PROJECT RELATED
EFFORTS: EMAIL:DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL DISN
BACKBONE ACTIVATIONS: EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-
INTEGRATION-LEAS E-BB-T@MAIL.MIL W. IMPLEMENTATION ASSISTANCE CONTINUED:
FOR CIRCUIT INSTALLATION ASSISTANCE WITH THE COMMERCIAL LEASED PATH,
CONTACT DCP COMMERCIAL ACTIVATION TEAM (CAT) AT D312-850-0820, C614-692-0820. X.
DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF LEASED COMMUNICATION
FACILITIES), OR EMAIL EQUIVALENT, WILL BE SUBMITTED, AS REQUIRED, ON THIS CIRCUIT
IAW DISAC-DITCO 350-135-1 BY THE STATION DESIGNATED IN PARAGRAPH 2H AS
CCO/CMO. GUIDANCE ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON "350-135-1,
DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES." Y.
UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY SERVICE
OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED
TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT
CENTER (DCCC) TOLL FREE NUMBER IS 1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML