SUBMIT A QUOTE TO PROVIDE, INSTALL, AND MAINTAIN, 10GB ETHERNET BETWEEN BLDG 5130, DCO ROOM, 5130 CATHEDRAL DRIVE, USAF ACADEMY, CO 80840 AND BLDG 1551, DCO, 6151 SPECKER AVENUE, FT CARSON, CO 80913-4143. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-83. The provisions that apply to this acquisition are identified in the DITCO Basic Agreements and Section M of the attached document. The associated North American Industrial Classification System (NAICS) code for this procurement is 517311 with a small business size standard of 1500. All quoted prices shall be identified in CLIN 0001 and applicable SLINs 0001AA, 0001AB, etc. as applicable for monthly recurring charges and CLIN 0002 and applicable SLINs 0002AA, 0002AB, etc. as applicable for non-recurring charges. CLIN/SLINs shall include item descriptions, quantities and units of measure. The requested service date and acceptance criteria are outlined in the attached inquiry. The product and service code for this telecommunications requirement is DG11. The selected company must comply with the following commercial item terms and conditions, which are incorporated herein by reference and as outlined in existing basic agreements: FAR 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition; FAR 52.212-3, Offeror Representations and Certifications - Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications if there is no existing basic agreement; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the selected clauses in paragraph (b) in the existing basic agreement. Quotes are due 16 AUG 2021, by 4:00 PM (CST) at DITCO Scott AFB, IL 62225-5406 Point of Contact(s): CASSANDRA Y. COOPER (618) 418-6862, EMAIL: CASSANDRA.Y.COOPER.CIV@MAIL MIL.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101321QA265-0003_v1.zip | ZIP file | |
| SOL QA265 PDF.pdf | ||
| HC101321QA265_v1.zip | ZIP file | |
| MAPS FOR DIVERSE Vendor Block Diagram Sample and Maps.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TESTING REQUIREMENTS HC101321QA265
THE VENDOR MUST CONTACT DISA GOC TIER-II ENGINEERING 48 HOURS PRIOR TO
BEGINNING THEIR END-TO-END TESTING. PHONE: C618-418-8627, D418-8627. 15. THE
PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST M. REMARKS CONTINUED:
FROM THE DROP SIDE OF THEIR OR LOCAL EXCHANGE CARRIERS FDP INSTALLED IN
THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THEIR OR LOCAL EXCHANGE
CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE "Z" LOCATION AND MUST
INCLUDE THE EXTENSION BETWEEN THE COMMERCIAL DEMARC AND THE
GOVERNMENT'S SDP. VENDOR MUST ENSURE TEST SETS ARE PLACED AT THE DROP
SIDE AT THE "A" LOCATION AND AT THE "Z" LOCATION. TESTING MUST BE SATISFACTORY
PRIOR TO TURN OVER TO THE GOVERNMENT FOR ACCEPTANCE TESTING. THE VENDOR
MUST TEST THE CIRCUIT FOR 24 HOURS IAW THE FULL ITU-T.Y.1564 BENCH MARKING
METHODOLOGY FOR NETWORK INTERCONNECT DEVICES STANDARD, AND AT THE
COMMITTED INFORMATION RATE (CIR) IAW ITU-T-Y.1564.
REMARKS: 1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS: (A) FIBER TERMINATION:
FRAME FORMAT: 10GB ETHERNET, 1310NM. "SC" OR "LC" CONNECTORS AS DETERMINED
BY SITE SURVEY. (B) COMMITTED INFORMATION RATE (CIR): 10GB. (C) ETHERNET FRAME
SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION UNIT (MTU) OF 9000
OCTETS (BYTES) JUMBO FRAMES. (D) NO NETWORK INTERFACE UNIT, DEDICATED PATH.
(E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE ENGINEERED INTO
CIRCUIT. (F) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT FOR 24 HOURS IAW
THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR NETWORK INTERCONNECT
DEVICES STANDARD, AND AT THE COMMITTED INFORMATION RATE (CIR) IAW ITU-T-
Y.1564. NOTE: ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU) IS EQUAL TO 9000 BYTES.
(G) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO USERS 24 HOURS A DAY,
SEVEN DAYS PER WEEK, MONTHLY PERFORMANCE OF 99.5% AVAILABILITY OR BETTER.
(H) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER UPON RECEIPT OF TROUBLE. N.
REMARKS CONTINUED: (I) VENDOR REQUIRED TO HAVE CIRCUIT VISIBILITY TO ASSIST IN
ANY CIRCUIT OUTAGES. (J) VENDOR MUST HAVE A 24X7 NETWORK OPERATIONS CENTER.
(K) TELECOM PROVIDER MUST MAINTAIN OPERATIONS, MAINTENANCE AND
ADMINISTRATION MONITORING OF ETHERNET CIRCUIT. (L) THE COMMERCIAL CIRCUIT
WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY THE DISA GOC IP BACKBONE
ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. C618-418-8627, D418-8627. 2.
VENDOR WINNING AWARD IS RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF
THE SERVICE IAW THE UNIQUE INSTALLATION FACTORS. 3. INSIDE WIRING IS
AUTHORIZED IAW THE UNIQUE INSTALLATION FACTORS. 4. VENDOR MUST COORDINATE
SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO REQUIRING ACCESS TO
FACILITIES AT BOTH USER LOCATIONS. 5. VENDOR MUST CONTACT DISA GOC TIER-II
ENGINEERING 48 HOURS PRIOR TO BEGINNING THEIR END-TO-END TESTING. 6. ALL
EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY PHONE TO THE DISA GOC IP
BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL. PRIMARY: C618-
418-9950, D418-9950 TOLL FREE: 855-868-9950. 7. DD FORM 1368 WILL BE SUBMITTED ON
THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT AFB, IL. GUIDANCE ON
SUBMISSION IS AVAILABLE AT <HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>.
CLICK ON "DISA-DITCO CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS
ACQUISITION PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE RATE:
10.3125 GIGABITS/S, +- 100 PPM LINE CODE: OPTICAL 1. TEST AND ACCEPTANCE: THIS
CIRCUIT SHALL PASS A FULLY DOCUMENTED, SATISFACTORY, 72 HOUR SOAK TEST BY
DISA GOC AT SCOTT AFB, IL. PRIMARY: C618-418-8627 D418-8627. 2. ERROR
PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING
PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN
99.5% OR BETTER. O. REMARKS CONTINUED: FRAME LOSS SHALL BE EQUAL TO ZERO
WHEN TESTING AT 10 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564
STANDARDS. JITTER SHALL BE LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 10
MSEC. 3. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER
THAN 24 HOURS. 4. ROUND TRIP DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK WILL BE
MEASURED IN MILLISECONDS FROM THE CUSTOMER'S SERVICE DELIVERY POINT (SDP)
SITE-A TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE
LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE
GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE
RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE
CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.
**UNIQ INSTALL FACTORS: (SP D) E4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR
MAINTENANCE OF SINGLE MODE FIBER FROM DROP SIDE OF DISA IE1 PROVIDED FIBER
TERMINATING PATCH PANEL INSTALLED IN CISCO ASR-9010 ROUTER SUITE TO OPTICAL
INTERFACE CARD INSTALLED IN CISCO ROUTER. COORDINATE TYPE OF CONNECTORS. G.
DISA IE4 IS RESPONSIBLE FOR INSTALLATION AND GSM-O FOR MAINTENANCE OF CISCO
ASR-9010 ROUTER, OPTICAL INTERFACE CARD BLDG 7475, ONE ROOM. ** DIVERSITY INFO:
SERVICE DIVERSITY REQUESTED; DUAL HOMING CCSD: TBD2; DUAL HOMING REMARKS:
TBD2 IS A PLACE HOLDER FOR THE CCSD OF THE DIVERSE REQUIREMENT. ** ADDITIONAL
PROVISIONING INFORMATION: DISA (DISN IP ROUTER NETWORK BACKBONE AND
BACKBONE HOSTS)(CONUS AND OCONUS) FUNDING TCO APL: DEFENSE INFORMATION
SYSTEMS AGENCY (DISA) FUNDING APPROVAL: THIS REQUIREMENT IS A BONA FIDE NEED
OF FY21 AND DISA FY21 FUNDING INFORMATION IS AVAILABLE IN DISA'S
TELECOMMUNICATIONS INVENTORY AND BILLING INFORMATION (TIBI) APPLICATION. P.
REMARKS CONTINUED: ANY ADDRESSEE ON THE (TSO) WILL NOTIFY ALL ADDRESSEES
IMMEDIATELY BY MESSAGE IDENTIFYING ANY ISSUES, PROBLEMS, OR SITUATIONS
WHICH MAY PREVENT OR DELAY THE IMPLEMENTATION OF THIS TELECOMMUNICATIONS
SERVICE ORDER (TSO). ALL STATIONS WILL REVIEW THE CONFIGURATION, EQUIPMENT,
CONTACT NUMBERS AND ADDRESSES CONTAINED IN THIS (TSO) AND PROVIDE UPDATES
TO ORIGINATOR OF (TSO) ANY ERRORS SO THAT SUBSEQUENT (TSOS) MAY BE UPDATED.
Q. OVERTIME/EXPEDITING CHARGES: YES, $0.00 R. SATELLITE OBJECTION: DIVERSITY:
DISA MANDATED; S. COMPLETION REPORT: FOR STATION DESIGNATED IN PARAGRAPH 2H
AS CCO/CMO, FOR THIS ACTION COMPLETION REPORTS WILL BE SUBMITTED IAW DISAC
310-130-1, CHAPTER 2 BY DISA GLOBAL IP, DSN 312-418-8627; COML 618-418-8627. ALL
OTHER CCO/CMO RESPONSIBILITIES REMAIN WITH THE DESIGNATED CCO/CMO IAW
DISAC 310-70-1, CHAPTER 8. T. DD FORM 1368: DD FORM 1368'S (MODIFIED USE OF
LEASED COMMUNICATION FACILITIES), OR EMAIL EQUIVALENT, WILL BE SUBMITTED, AS
REQUIRED, ON THIS CIRCUIT IAW DISAC-DITCO 350-135-1 BY THE STATION DESIGNATED IN
PARAGRAPH 2H AS CCO/CMO. GUIDANCE ON SUBMISSION IS AVAILABLE AT
HTTP://WWW.DITCO.DISA.MIL/CORPORATELIBRARY/HOME.ASP. CLICK ON "350-135-1,
DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION PROCEDURES." U. THIS TSO IS
IN SUPPORT OF EXERCISE/PROJECT: DISA MPLS IMPLEMENTATION PROJECT (D300) V.
JUSTIFICATION OF SERVICE REQUESTED: THIS ACTION SUPPORTS DISN IP BACKBONE
IMPLEMENTATION. W. IMPLEMENTATION ASSISTANCE: IMPLEMENTATION ASSISTANCE:
FOR SERVICE ACTIVATION INQUIRIES/SCHEDULING/ASSISTANCE, NAVIGATE TO THE DISA
GLOBAL SERVICE ACTIVATIONS CUSTOMER ACCESS PORTAL:
HTTPS://DISA.DEPS.MIL/DISA/COP/GSM-O/BACKBONE/CUSTOMER%20ACCESS%2
0SITE/SITEPAGES/SAM%20CUSTOMER%20HOMEPAGE.ASPX, OR CONTACT DSN 312-418-
8627, CMCL 001-618-418-8627. FOR EMAIL SUPPORT, PLEASE CONTACT THE APPROPRIATE
TEAM BELOW: DEDICATED/NIPRNET/SIPRNET/VPN SERVICE ACTIVATIONS: EMAIL:
DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL SIPRNET ACCESS
MIGRATION (SAM) PROJECTS (D508, D710, D806, D910): EMAIL:
DISA.SCOTT.GLOBAL.MBX.IMPACT-TEAM@MAIL.MIL FOR ALL OTHER PROJECT RELATED
EFFORTS: EMAIL:DISA.SCOTT.GLOBAL.MBX.RF-CIRCUIT-ACTIVATIONS@MAIL.MIL DISN
BACKBONE ACTIVATIONS: EMAIL: DISA.SCOTT.GLOBAL.MBX.CASA-INFRASTRUCTURE-
INTEGRATION-LEAS E-BB-T@MAIL.MIL X. IMPLEMENTATION ASSISTANCE CONTINUED: FOR
CIRCUIT INSTALLATION ASSISTANCE WITH THE COMMERCIAL LEASED PATH, CONTACT
DCP COMMERCIAL ACTIVATION TEAM (CAT) AT D312-850-0820, C614-692-0820. Y.
UNSATISFACTORY SERVICE REPORTING INSTRUCTIONS: FOR UNSATISFACTORY SERVICE
OR TO REPORT EQUIPMENT AND/OR CIRCUIT PROBLEMS INVOLVING DISA PROVIDED
TRANSPORT AND/OR EQUIPMENT, PLEASE CONTACT THE DISN CUSTOMER CONTACT
CENTER (DCCC) TOLL FREE NUMBER IS 1-844-347-2457 (1-844-DISA HLP) OPTION 2, COML
1-614-692-0032 OPTION 2, DSN 312-850-0032 OPTION 2.
UNIQUE INST FACT: (1) COMMERCIAL FIBER POINT OF PRESENCE (2) FIBER CABLE X-
CONNECT, IN-HOUSE, INSIDE WIRE, SINGLE-MODE, 1310NM, TELCO (3) FIBER
TERMINATING PATCH PANEL (SITE PROVIDED) (4) FIBER CABLE, ON-BASE, SINGLE-MODE,
1310NM, FT CARSON PERSONNEL AMPLIFYING INFO: A. VENDOR IS RESPONSIBLE FOR
INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM COMMERCIAL FIBER
POINT OF PRESENCE FIBER DISTRIBUTION PANEL BLDG 1551, DCO ROOM TO DROP SIDE
OF SITE PROVIDED FIBER TERMINATING PANEL BLDG 1551, DCO ROOM. COORDINATE
TYPE CONNECTORS FOR TERMINATION TO SITE PROVIDED FIBER PATCH PANEL. B.
VENDOR MUST COORDINATE WITH GOVERNMENT SITE PERSONNEL TO CONDUCT WALK
THROUGH SITE SURVEY FOR THE EXACT CABLE FT. FROM COMMERCIAL POP (FDP)
INSTALLED IN THEIR EQUIPMENT SUITE TO SITE PROVIDED FIBER PATCH ALL IN BLDG
1551, DCO ROOM. C. VENDOR MUST PROVIDE FIBER STRANDS FROM DROP SIDE OF
COMMERCIAL POINT OF PRESENCE (FIBER DISTRIBUTION PANEL) TO GOVERNMENT SITE
PATCH PANEL ALL IN BLDG 1551, DCO ROOM WITHOUT SPLICING AND OR USE OF
CONNECTORS TO CONNECT 2 OR MORE FIBER STRANDS MEANING THE FIBER CANNOT
BE BROKEN IN THE MIDDLE AND MUST BE CONTINUOUS. D. CIRCUIT MUST BE TAGGED
WITH LOCAL CIRCUIT ID AND LONG HAUL CIRCUIT NO. AT DROP SIDE OF COMMERCIAL
DEMARC AND SITE PROVIDED FIBER PATCH PANEL BLDG 1551, DCO ROOM.
ADDITIONALLY, VENDOR MUST SHOW SITE PERSONNEL LISTED ON THIS ORDER THE
EXACT TERMINATION POINT WHEN INSTALLATION IS COMPLETE. E. VENDOR MUST
SCHEDULE/COORDINATE WITH POC'S LISTED ON THIS ORDER 72 HOURS IN ADVANCE
PRIOR TO SITE SURVEYS OR INSTALLATIONS. F. FT CARSON PERSONNEL ARE
RESPONSIBLE FOR INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER FROM
LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 1551, DCO ROOM
TO LINE SIDE OF SITE PROVIDED FIBER TERMINATING PATCH PANEL BLDG 7475, ONE
ROOM.