SUBMIT A QUOTE PROVIDE, INSTALL, AND MAINTAIN, 10GB ETHERNET BETWEEN BLDG 5130, DCO ROOM, 5130 CATHEDRAL DRIVE, USAF ACADEMY, CO 80840 AND BLDG 1038, ROOM 35A, 175 EAST STEWART AVENUE, PETERSON AFB, CO 80914-1650. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This solicitation is issued as a request for quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-83. The provisions that apply to this acquisition are identified in the DITCO Basic Agreements and Section M of the attached document. The associated North American Industrial Classification System (NAICS) code for this procurement is 517311 with a small business size standard of 1500. All quoted prices shall be identified in CLIN 0001 and applicable SLINs 0001AA, 0001AB, etc. as applicable for monthly recurring charges and CLIN 0002 and applicable SLINs 0002AA, 0002AB, etc. as applicable for non-recurring charges. CLIN/SLINs shall include item descriptions, quantities and units of measure. The requested service date and acceptance criteria are outlined in the attached inquiry. The product and service code for this telecommunications requirement is DG11. The selected company must comply with the following commercial item terms and conditions, which are incorporated herein by reference and as outlined in existing basic agreements: FAR 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition; FAR 52.212-3, Offeror Representations and Certifications - Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications if there is no existing basic agreement; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the selected clauses in paragraph (b) in the existing basic agreement. Quotes are due 16 AUG 2021, by 4:00 PM (CST) at DITCO Scott AFB, IL 62225-5406 Point of Contact(s): CASSANDRA Y. COOPER (618) 418-6862, EMAIL: CASSANDRA.Y.COOPER.CIV@MAIL MIL.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| HC101321QA263-0003_v3.zip | ZIP file | |
| HC101321QA263 0002.pdf | ||
| HC101321QA263_v1.zip | ZIP file | |
| MAPS FOR DIVERSE Vendor Block Diagram Sample and Maps.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TESTING REQUIREMENTS HC101321QA263
THIS REQUIREMENT MUST BE ENGINEERED AND PROVISIONED TOTALLY DIVERSE END
TO END TO GOVERNMENT'S SERVICE DELIVERY POINTS (SDP'S) FROM TSR
RU17FEB216985, MEANING THAT PHYSICAL PATHS ARE TOTALLY SEPARATE INCLUDING
MAN HOLES, CONDUIT, (CENTRAL K. REMARKS CONTINUED: OFFICE LOCATIONS), AND
FIBER BUILDS. ADDITIONALLY AS A MINIMUM THERE MUST BE A 50 METER PHYSICAL
SEPARATION FROM TSR RU17FEB216986. ***THE 50 METER SEPARATION IS WAIVED
INSIDE BLDG 5130 FOR USAF ACADEMY LOCATION.*** 9. THE TELECOM PROVIDER MUST
PROVIDE DITCO COLOR POWERPOINT DRAWI NGS FOR TECHNICAL REVIEW SHOWING
THE ROUTES FROM THE COMMERCIAL D EMARCS TO THE SUPPORTING CENTRAL
OFFICES AND/OR WIRING CENTERS. D RAWINGS MUST INCLUDE SEPARATION DISTANCES
BETWEEN DIVERSE REQUIRE MENTS, TOTAL FIBER MILES AND ROUND TRIP DELAY (RTD),
AND FIBER RO UTES RED LINED END TO END SO THE GOVERNMENT CAN CONFIRM
PHYSICAL END TO END DIVERSITY REQUIREMENTS ARE MET. ADDITIONALLY, THE VEND
OR IS TO PROVIDE DITCO WITH DETAILED CIRCUIT/PATH CONNECTIVITY DI AGRAMS, IN
KMZ OR KML FORMAT, IDENTIFYING ALL POINTS OF PRESENCE (POP) FOR EVALUATION
AND AS A FINAL RECORD OF THE INSTALLED PATH. THESE DIAGRAMS MUST BE
PROVIDED TO DISA HQ IE16 (DISA.MEADE.IE.M BX.IE16-PROVISIONING-TEAM@MAIL.MIL)
FOR HISTORICAL PURPOSES. 10. THE VENDOR MUST PROVIDE LIGHT LEVEL READINGS
(SIGNAL STRENGTH IN DBM) ON THE EXTENSION FROM COMMERCIAL POP TO THE
GOVERNMENT SERVICE DELIVERY POINT (SDP) AT THE "A" AND "Z" LOCATION PRIOR TO
CIRCUIT TURN OVER TO THE GOVERNMENT ENSURING LEVELS ARE WITHIN SPECS. LIGHT
LEVELS MUST BE ADJUSTED TO -3 TO -9 DBM. 11. THE VENDOR MUST TERMINATE 10GB
ETHERNET SERVICE AT SERVICE DELIVERY LOCATIONS, IAW UNIQUE INSTALLATION
FACTORS. 12. THE VENDOR MUST CONDUCT WALK-THROUGH SITE SURVEY PRIOR TO
INSTALLATION AT BOTH LOCATIONS. 13. THE VENDOR MUST CONTACT DISA GOC IP
BACKBONE ENGINEERING AND IMPLEMENTATION GROUP UPON RECEIPT OF A VALID TSO
TO ESTABLISH THE COORDINATION AND ACTIVATION PROCESS. PHONE: C618-418-8627,
D418-8627. 14. THE VENDOR MUST CONTACT DISA GOC TIER-II ENGINEERING 48 HOURS
PRIOR TO BEGINNING THEIR END-TO-END TESTING. PHONE: C618-418-8627, D418-8627. 15.
THE PROVIDER MUST CONDUCT A SATISFACTORY 24-HOUR TEST L. REMARKS
CONTINUED: FROM THE DROP SIDE OF THEIR OR LOCAL EXCHANGE CARRIERS FDP
INSTALLED IN THEIR EQUIPMENT SUITE AT THE "A" LOCATION TO THEIR OR LOCAL
EXCHANGE CARRIERS FDP INSTALLED IN THEIR EQUIPMENT SUITE AT THE "Z" LOCATION
AND MUST INCLUDE THE EXTENSION BETWEEN THE COMMERCIAL DEMARC AND THE
GOVERNMENT'S SDP. VENDOR MUST ENSURE TEST SETS ARE PLACED AT THE DROP
SIDE AT THE "A" LOCATION AND AT THE "Z" LOCATION. TESTING MUST BE SATISFACTORY
PRIOR TO TURN OVER TO THE GOVERNMENT FOR ACCEPTANCE TESTING. THE VENDOR
MUST TEST THE CIRCUIT FOR 24 HOURS IAW THE FULL ITU-T.Y.1564 BENCH MARKING
METHODOLOGY FOR NETWORK INTERCONNECT DEVICES STANDARD, AND AT THE
COMMITTED INFORMATION RATE (CIR) IAW ITU-T-Y.1564.
REMARKS: 1. CIRCUIT REQUIRES THE FOLLOWING PARAMETERS: (A) FIBER
TERMINATION: FRAME FORMAT: 10GB ETHERNET (OPTICAL HANDOFF-10GB ETHERNET-
LAN-PHY-SINGLE MODE FIBER), 1310NM. "SC" OR "LC" CONNECTORS AS DETERMINED BY
SITE SURVEY. NOTE: WHEN EXTENDED REACH OPTICS ARE USED THAT CHANGE THE
TX/RX WAVELENGTH OF THE OPTIC, THE VENDOR WILL NOTIFY THE GOVERNMENT 30
DAYS PRIOR TO DELIVERY. (B) COMMITTED INFORMATION RATE (CIR): 10GB. (C)
ETHERNET FRAME SIZE WILL BE CONFIGURED TO SUPPORT MAXIMUM TRANSMISSION
UNIT (MTU) OF 9000 OCTETS (BYTES) JUMBO FRAMES. (D) NO NETWORK INTERFACE UNIT,
DEDICATED PATH. (E) GFE CLOCKING: VENDOR ESFU (OR EQUIVALENT) NOT TO BE
ENGINEERED INTO CIRCUIT. (F) TESTING CRITERIA: VENDOR MUST TEST THE CIRCUIT
FOR 24 HOURS IAW THE FULL ITU-T.Y.1564 BENCH MARKING METHODOLOGY FOR
NETWORK INTERCONNECT DEVICES STANDARD, AND AT THE COMMITTED INFORMATION
RATE (CIR) IAW ITU-T-Y.1564. NOTE: ETHERNET FRAME SIZE DESIGNATOR 'H' (MTU) IS
EQUAL TO 9000 BYTES. (G) LINE MUST REMAIN FULLY OPERATIONAL AND AVAILABLE TO
USERS 24 HOURS A DAY, SEVEN DAYS PER WEEK, MONTHLY PERFORMANCE OF 99.5%
AVAILABILITY OR BETTER. (H) 1 HOUR RESPONSE TIME TO RESPOND TO CUSTOMER
UPON RECEIPT OF TROUBLE. M. REMARKS CONTINUED: (I) VENDOR REQUIRED TO HAVE
CIRCUIT VISIBILITY TO ASSIST IN ANY CIRCUIT OUTAGES. (J) VENDOR MUST HAVE A 24X7
NETWORK OPERATIONS CENTER. (K) TELECOM PROVIDER MUST MAINTAIN OPERATIONS,
MAINTENANCE AND ADMINISTRATION MONITORING OF ETHERNET CIRCUIT. (L) THE
COMMERCIAL CIRCUIT WILL BE ACCEPTED ON BEHALF OF THE GOVERNMENT BY THE
DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP, SCOTT AFB, IL.
C618-418-8627, D418-8627. 2. VENDOR WINNING AWARD IS RESPONSIBLE FOR
INSTALLATION AND MAINTENANCE OF THE SERVICE IAW THE UNIQUE INSTALLATION
FACTORS. 3. INSIDE WIRING IS AUTHORIZED IAW THE UNIQUE INSTALLATION FACTORS. 4.
VENDOR MUST COORDINATE SITE VISIT WITH POC'S 72 HOURS IN ADVANCE PRIOR TO
REQUIRING ACCESS TO FACILITIES AT BOTH USER LOCATIONS. 5. VENDOR MUST
CONTACT DISA GOC TIER-II ENGINEERING 48 HOURS PRIOR TO BEGINNING THEIR END-
TO-END TESTING. 6. ALL EQUIPMENT AND CIRCUIT PROBLEMS WILL BE REPORTED BY
PHONE TO THE DISA GOC IP BACKBONE ENGINEERING AND IMPLEMENTATION GROUP,
SCOTT AFB, IL. PRIMARY: C618-418-9950, D418-9950 TOLL FREE: 855-868-9950. 7. DD FORM
1368 WILL BE SUBMITTED ON THIS TRUNK IAW DISAC-DITCO 350-135-1 BY RNSOC, SCOTT
AFB, IL. GUIDANCE ON SUBMISSION IS AVAILABLE AT
<HTTP://WWW.DITCO.DISA.MIL/ASP/PUBLICATIONS.ASP>. CLICK ON "DISA-DITCO
CIRCULAR, 350-135-1, DEFENSE COMMERCIAL COMMUNICATIONS ACQUISITION
PROCEDURES."
MINIMUM TECHNICAL SPECIFICATIONS: SPECIFIC FORMAT TO BE USED IS: LINE RATE:
10.3125 GIGABITS/S, +- 100 PPM LINE CODE: OPTICAL 1. TEST AND ACCEPTANCE: THIS
CIRCUIT SHALL PASS A FULLY DOCUMENTED, SATISFACTORY, 72 HOUR SOAK TEST BY
DISA GOC AT SCOTT AFB, IL. PRIMARY: C618-418-8627 D418-8627. 2. ERROR
PERFORMANCE: ERROR PERFORMANCE SHALL BE BETTER THAN THE FOLLOWING
PARAMETER THRESHOLDS TO BE ACCEPTABLE: AVAILABILITY SHALL BE GREATER THAN
99.5% OR BETTER. N. REMARKS CONTINUED: FRAME LOSS SHALL BE EQUAL TO ZERO
WHEN TESTING AT 10 GIGABIT HIGHEST FRAME RATE, AND SHALL MEET ITU-T-Y.1564
STANDARDS. JITTER SHALL BE LESS THAN 3 MSEC. DELAY SHALL BE BETTER THAN 10
MSEC. 3. MEAN TIME TO LOSS OF BIT COUNT INTEGRITY (MTTLBCI) SHALL BE GREATER
THAN 24 HOURS. 4. ROUND TRIP DELAY (RTD) FOR THIS DISA TRANSPORT TRUNK WILL BE
MEASURED IN MILLISECONDS FROM THE CUSTOMER'S SERVICE DELIVERY POINT (SDP)
SITE-A TO THE CUSTOMER'S SERVICE DELIVERY POINT (SDP) SITE-Z. THE RTD SHALL BE
LESS THAN OR EQUAL TO 10 MILLISECONDS TO EFFECTIVELY SUPPORT THE
GOVERNMENT'S MISSION. THE GOVERNMENT ACCEPTING AUTHORITY WILL CONFIRM THE
RTD DURING THE TURN-UP AND TEST PHASE AND IF IT DOES NOT ALIGN WITH THE
CONTRACTORS PROPOSAL, DISA IE161 WILL NOTIFY DITCO IMMEDIATELY IN WRITING.