Item
No.
Qty Unit Description UNIT Price Total Price ea
Conviron model PGW40 Plant Growth Chamber, including installation, as per specifications
Conviron model PGR15 Plant Growth Chamber, including installation, as per specifications
Deduct if completed as a single mobilization of installation for one (x1) model PGW40 Plant Growth Chamber and one
(x1) model PGR15 Plant Growth Chamber
Please refer to attached Technical Proposal
TOTAL PRICE
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
12-May-20 info@conviron.com www.conviron.com
Controlled Environments Inc.
#2 - 572 S 5th Street, PO Box 347
Pembina, ND, 58271, USA tel: +1.701.280.9635 toll free: +1.800.363.6451 fax: +1.204.786.7736
TO: USDA - ARS NO: CP21913-F03
1150 East 1400 North Logan DATE: 12-May-20 Logan, UT 84341 Page 1
Spec. # SPEC-PGW40 I Rev.10165_35 I 23-Apr-2020
QUOTATION & TECHNICAL SPECIFICATIONS
CONVIRON MODEL PGW40 PLANT GROWTH CHAMBER
1.0 Control System - Conviron CMP6060:
1.1 General1: The CMP6060 v6.0 control system is a robust industrial grade control system that is designed specifically for plant growth chambers and rooms. Its intuitive color touch screen interface and limitless scalability make it a reliable, flexible and user friendly system.
1.2 Programming: The CMP6060 is capable of storing up to 16 real-time user-entered programs each containing up to 48 lines with one minute resolution. Each program defines a single 24- hour period.
Programs are then entered into a "Schedule" (a sequence of up to 8 program entries) to create a single day, multi day, or seasonal schedule. Programs are entered via a high resolution color touch-screen display.
1.3 Process Control Mode: All chamber process transitions occur in STEP mode, with the exception of temperature, which can be set to either STEP or global ramp (gRAMP) mode.
1.4 Data Logging and Graphing:
1.4.1 Local Data: The data available at the local display screen includes up to seven chamber variables such as temperature, humidity, lighting and CO2. Parameters are all logged automatically every 30 seconds and can be viewed in the form of Trend graphs. Trend graphs can be viewed, with up to five days of history, directly on the local display screen for both 'set-point' and 'actual' values. Zoom and Pan Functions provide additional visualization tools allowing the User to precisely and accurately view and access the data.
A cursor can be used to display the value and the setpoint at the cursor location.
1.4.2 The data available remotely is more substantial and includes every input and output parameter being monitored and controlled. Data is automatically logged and log rate can be set in multiples of 6 seconds regardless of the number of parameters. This provides unprecedented data resolution for the User while it also benefits service personnel. Log data is accessed in several ways:
• A network-connected PC (Note: Requires WEBCARD option on GEN Series products, sold separately)
• An internet-enabled PC (Note: Requires WEBCARD option on GEN Series products, sold separately)
• Conviron's Central Management™ System (sold separately)
1.4.3 Trend data can also be downloaded through the USB port of the chamber touch screen.
Chamber data archived on the touch screen is logged every 30 seconds with up to fifteen days of history.
1 All performance control tolerances including temperature, humidity, CO2 are based on steady state conditions. Environmental conditions will fluctuate during programmed transitions between set points, and return to control tolerances once steady-state conditions resume.
mailto:info@conviron.com http://www.conviron.com/
CONVIRON REFERENCE: NO. CP21913-F03
MODEL PGW40 PLANT GROWTH CHAMBER
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
1.5 Alarms: Audible and color coded visual alarms are provided. User-settable absolute alarms for all controlled processes and User-settable process tracking alarms for temperature are available for the User to determine how tightly they want to monitor the experiment. In addition, there are also
"built in" alarms available for chamber component monitoring. Alarm history is logged to daily text files easily retrievable from any Ethernet connected computer (either with or without a Central Management™) or through the local control screen (last 15 alarm events).
1.6 Security: Password-protected levels are reserved for users, administrators and service personnel.
The CMP is capable of storing up to 50 unique names and passwords for user and administrator profiles.
1.7 Start-Up Delay: Chambers can be programmed with varying restart times to reduce start-up loads after a power failure.
1.8 Communications: Ethernet connectivity is delivered with every controller. Controller, mask and Host
IP address are easily settable from the Status screen. The controller is shipped communications-ready.
1.9 Auxiliary and Central Alarm Contacts: Alarm contacts for connection to a building management system or (optional) auto dialer.
1.10 The chamber local display can be mirrored on Conviron's Central Management™ System (sold separately) allowing remote support, training and access to all the local chamber functions remotely.
1.11 Lighting Run Times: The controller tracks the amount of time (in hours) each lighting output has been ON. The run time of each output can be viewed and reset using the local display.
2.0 Construction2: (Note: All dimensions are nominal.)
2.1 Exterior Dimensions: 140"W x 70"D x 102"H (3556mmW x 1780mmD x 2590mmH)
2.2 Interior Dimensions: 96½"W x 62"D x 94"H (2450mmW x 1575mmD x 2385mmH).
2.3 Floor: Perforated aluminum channel floor for uniform upward air flow - Unifloor®.
2.4 Subfloor: Molded resin fiberglass construction with floor drain.
2.5 Growth Area: 41.5ft2 (3.86m2).
2.6 Growth Capacity: 263ft3 (7443 liters).
2.7 Growth Height: 76" (1930mm) from Unifloor® to Lightright™ in the UP position.
2.8 Exterior Finish: White enamel baked on stucco 26ga. galvanized steel.
2.9 Interior Finish: White enamel baked on smooth 24ga. galvanized steel.
2.10 Conditioning Compartment: Stainless steel drain pan for corrosion protection.
2.11 Cabinet Construction: Wall panels of bonded paneling construction with 4" (100mm) of foamed-in-place CFC-free polyurethane insulation.
2.12 Doors: Two reach-in doors with light tight gaskets and keyed magnetic locks, each clear opening 36" x 78" (915mm x 1980mm).
2.13 Control Panel: Left hand (right hand model optional).
2.14 Instrument Ports: Two ports, 2" (50mm) with light tight caps.
3.0 Lighting:
3.1 Intensity : Approximately 1400 micromoles/m2/s
3.2 Programming and Control: Independent, 5 level programming of each light type.
2 Local Regulatory Codes: Equipment design and manufacture may not address all local, state or country-specific regulatory requirements including elements such as seismic anchoring, electrical configuration, or similar. Client to identify and advise of such requirements prior to issuance of a purchase order.
3 Light measurement at 6" (150mm), chamber temperature of 25°C. Light intensities are nominal values measured at the rated chamber supply voltage and (dimmable lighting) with a maximum light output (verified by a LI-190R factory reference Quantum Sensor). With fluorescent lamps, light intensity values may be lower than specified if measured at temperature set points below 25°C.
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
3.3 Lamps: Balanced spectrum for plant growth using T5 fluorescent and halogen incandescent lamps.
3.4 Lamp Fixture: Counterbalanced for adjustable light intensities - Lightright™.
3.5 Lamp Heat: Removed by refrigeration system.
3.6 Ballasts: High efficiency electronic.
3.7 Light Meter: Quantum light meter for display and recording of light output, displayed through user interface.
4.0 Temperature Control: (Maximum design ambient temperature is +35°C)
4.1 Range: +2°C to +40°C lights ON/OFF. Low temperature operation enables the chamber to be operated with lights ON to +2°C (No fresh air below 8°C.) A defrost cycle will occur resulting in a temperature increase (spike) for temperatures set below +8°C lights ON/OFF. Temperature spikes (up to ±5°C) and defrost time are dependent on chamber operating temperature. During this cycle, the lights will be turned off (factory default). Specified light intensity will be reduced when chamber is operating at low temperatures.
Note:
1) Chamber shall include drain pan and drain line. With additive humidity option, chamber shall also include purge function which requires low pressure air supplied to cabinet (35 psi)
2) When combined with SDF option, water cooled condenser shall be located on top of enclosure.
Cabinet height shall increase by 10" (254mm). Control panel to be located on machine compartment side of unit. Width increases by 10" (254mm). Consult factory for recommended clearances required for service and building utility connections.
4.2 Control : ±0.5°C, at control point.
4.3 Temperature Safety Limits:
Primary: A programmable min and max temperature or a limit tracking alarm that automatically follows the programmed set point.
Secondary: An independent factory-set high and low temperature limit is also provided for increased assurance.
Audible alarms are included based on user-defined limits.
4.4 Aspirator: Sensors are located in a self-contained portable aspirator. This allows accurate measuring and recording by sensing at top of plant canopy.
5.0 Refrigeration:
5.1 Condensing Unit: Cabinet is supplied with a water-cooled condensing unit with hot gas bypass system for continuous compressor operation and close temperature control. Includes a 3-way water valve and hand operated shut off bypass valve. Maximum pressure drop across the condenser and water valve not to exceed 10psi (0.7 bar). Customer to provide water supply temperature. (Alternate cooling systems available.)
5.2 Valve: Electronic 3-way modulating valve that regulates the temperature function of the chamber.
5.3 Heat Exchanger Coil(s): Copper-tube construction/aluminum fin.
5.4 Refrigerant: Condensing unit is charged with CFC-free refrigerant.
5.5 Monitoring:
Refrigeration system operation monitored by control system, including visual and audible alarm.
Pressure transducers allow for real-time diagnostics for preventative maintenance and repair.
6.0 Air Flow:
6.1 Vertical: Uniformly upward through Unifloor® over the entire growth area.
4 Measured by NIST traceable calibrated temperature sensor without test materials or optional accessories
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
6.2 Fresh Air: Filtered inlet and adjustable exhaust 55ft3/min (1.55m3/min).
7.0 Humidity Control: (Based on +21°C and 50% RH ambient condition5)
7.1 Range: Up to 90% RH lights OFF, 75% RH lights ON, limited by a +25°C maximum dew point
(empty chamber).
7.2 Additive humidity through use of spray nozzles.
7.3 Control: ±3% RH. System uses a dry humidity sensor to directly measure humidity in %RH.
Note: With low temperature operation, no control below 4°C.
8.0 Carbon Dioxide Additive Control: (Optional)
8.1 Range: No control on basic unit.
9.0 Utility Requirements : (Rating increases with some options.)
9.1 Electrical Service: (Alternative services available, consult factory)
60Hz: 120/208-3-60Hz-4 wire plus ground
9.2 Drain: Floor drain must be provided outside footprint of cabinet.
9.3 Disconnect: Main power disconnect switch.
9.4 Spray nozzles require 60 psi (4.2 bar) water supply pressure and must be supplied with reverse osmosis water. Water resistivity must be between 0.01 to 0.02 Meg ohm-cm (MO-cm). Maximum water usage to maintain specified levels is 6 liters/hr. If the above water supply pressure is not available, the CPSNH option is required to supply necessary pressure.
9.5 Provided with a U.S. electrical inspection by an inspection authority accredited by OSHA.
10.0 Warranty and After Sales Service:
10.1 Warranty and after sales service is handled by our dedicated team of service professionals. They provide a 24-hour manned service phone to facilitate any repair emergency. In addition, the team is available, during regular business hours, to assist with any service or warranty repairs, replacement parts or questions. Conviron also offers a fully trained international network of independent third party service providers who can affect repairs wherever your chamber is located.
10.1.1 Two year warranty (extended warranty optional).
10.2 To access this free support, please contact the service group at;
Phone: (204) 786-6451 Fax: (204) 786-7736 Toll Free: 1-800-363-6451 Email info@conviron.com www.conviron.com
11.0 Installation:
The following specifications outline the typical responsibilities of the parties as they pertain to installation of Conviron chambers, rooms and central management (CM).
11.1 Conviron to be responsible for/provide the following:
11.1.1 Receive and off-load equipment. Transport the equipment from the off-loading or storage area to the assembly area.
11.1.2 Uncrate equipment and dispose of crating material in customer supplied disposal bins.
11.1.3 Assemble and make work the supplied equipment using qualified personnel.
11.1.4 Start-up and check equipment performance and operation to factory specifications.
5 Measured by NIST traceable calibrated temperature sensor without test materials or optional accessories.
6 This unit will tolerate ±10% voltage fluctuation from the rated voltage on the serial plate. A voltage stabilizer must be used if the fluctuation is greater than ±10%. Failure to do so can result in serious damage to the compressor and electronic components and will void warranty. Disconnect switch must be sized by a local qualified electrician.
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
a) Verification and function testing of building power, all input devices, all controlled devices, all non controlled devices, refrigeration and safety components and if applicable all special control sequences and devices; and
b) A 24-hour test to demonstrate performance of all controlled parameters to their specified limits.
11.1.5 Provide four hours of instruction on use and maintenance of the equipment. Additional instruction and/or training available by agreement.
11.1.6 Installation Instruction: Electronically provided to customer upon project completion.
Printed copy available (optional), consult factory.
11.2 Customer to be responsible for/provide the following:
11.2.1 If there will be a delay between the receipt and building utility connections of the equipment, the customer is responsible for providing adequate and secure storage. Customer must provide forklift type equipment to remove equipment from common carrier highway transport truck/s.
11.2.2 The customer must prepare a clean and unobstructed route, including sufficient clearance through doorways, openings, elevators, etc. between the off-loading or storage area and the location of chamber assembly.
11.2.3 The customer must ensure that installers have adequate on-site storage and staging areas.
If no such space is available, Conviron may arrange for storage containers at the customer's expense.
11.2.4 Supply and connection of building services to the equipment in accordance with local codes, restrictions and legislation. These services must be fully functional and sized in accordance with the equipment specifications in a timely manner. The customer shall supply and connect all building services to the equipment, including any cutting, penetrations, or patching required.
Building services may include some or all of the following:
-Electrical service (more than one may be required)
-Condenser water (supply and return)
-Purified water for humidity system
-Compressed air for humidity system
-Fresh air and/or exhaust air connections
-Carbon dioxide supply
-Floor drain connections
-Conduit or cable trays or other special requirements for Ethernet support (applicable to
CM only)
11.2.5 Equipment must be installed on level floors. The customer shall ensure that all floors are level to within ½ inch.
11.2.6 The quotation for installation services assumes that all on-site responsibilities of the customer have been fulfilled upon Conviron commencing the installation such that
Conviron can complete the installation in a single mobilization. This includes the provision of all building services, operating as specified. Should site delays result in Conviron having to suspend its installation work, the customer shall reimburse Conviron for all downtime, including the cost of return visits and associated expenses. Expenses shall be charged on a cost plus 15% basis, and time shall be charged at Conviron's standard installation rates.
11.3 General: Conviron understands there is no requirement to provide unionized labor in the performance of its work. As such, Conviron may supply non-union or unionized trade labor at its sole discretion.
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
11.4 Local Regulatory Codes: No allowances have been made in the equipment design or manufacture to consider local regulatory codes including seismic requirements. Building code requirements for your area should be investigated prior to equipment installation.
11.5 Conviron provides installation services with the understanding that said services are to install and make work, within a given period of time, the Conviron supplied equipment. In no way does Conviron guarantee, or imply to guarantee, to supply a minimum number of man-hours and/or installation personnel at any time during the process of this installation.
ISO 9001 Registered
CONFIDENTIAL
Controlled Environments Limited, Controlled Environments Inc., Conviron Europe Ltd., Conviron Science and Technology
(Shanghai) Co. Ltd., Conviron Asia Pacific PTY Ltd. and/or Argus Control Systems Ltd. (herein referred to collectively as
"Conviron") claims full ownership, property, design and marketing rights to the information and material herein disclosed. It is supplied in confidence and any reproduction, fabrication or re-communication of any nature or kind of the contents without the express prior written consent of Conviron is strictly prohibited.
MODEL PGR15 PLANT GROWTH CHAMBER
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
Spec. # SPEC-PGR15 I Rev.10165_35 I 23-Apr-2020
QUOTATION & TECHNICAL SPECIFICATIONS
CONVIRON MODEL PGR15 PLANT GROWTH CHAMBER
1.0 Control System - Conviron CMP6060: As detailed on page 1-2.
2.0 Construction7: (Note: All dimensions are nominal.)
2.1 Exterior Dimensions: 104"W x 35"D x 88"H (2640mmW x 890mmD x 2235mmH)
2.1.1 Split machine compartment for convenience and flexibility for installation with reduced or limited access. Cabinet component dimensions become;
1) Growth Section - 82½"W x 35"D x 88½"H
2) Control Section - approximately 36"W x 35"D x 78½"H
2.2 Interior Dimensions: 73¼"W x 31 ¾"D x 65¼"H (1870mmW x 805mmD x 1655mmH)
2.3 Floor: Perforated aluminum channel floor for uniform upward air flow - Unifloor®.
2.4 Growth Area: 16.1ft2 (1.5m2).
2.5 Growth Capacity: 78ft3 (2220 liters).
2.6 Growth Height: 57" (1450mm) from Unifloor® to Lightright™ in the UP position.
2.7 Cabinet Construction: Bonded paneling using CFC-free insulation.
2.8 Exterior Finish: Blue-green enamel baked on patterned aluminum.
2.9 Interior Finish: Reflective white enamel baked on smooth aluminum.
2.10 Drain Pan: 22 gauge stainless steel drain pan under the entire growth area, sloped the full length toward the machine compartment. A drain fitting is installed and connected to an external drain tube.
2.11 Condensing Unit Access: Easy access to compressor and refrigeration components through an exterior panel on the end of the chamber.
2.12 Doors: Two reach-in doors with keyed magnetic locks, each clear opening 30"W x 54"H (760mmW x 1375mmH).
2.13 Observation Window: Dual pane with light tight cover 11" x 15" (280mm x 380mm). Note: With Ultra
Low Temperature (ULT) option, observation window is unavailable.
2.14 Shelf: Corrosion resistant wire adjustable on ½" (12mm) centers.
2.15 Control Panel: Left hand (right hand model optional).
2.16 Instrument Ports: Two ports, 1" (25mm) with light tight caps.
2.17 Convenience Receptacle: Electrical receptacle located within growth area (2 amp allowance).
(Consult factory for additional amperage, if required).
2.18 Factory assembled, tested and fully crated.
3.0 Lighting:
3.1 Intensity : Light intensity approximately 1,000 micromoles/m2/s at a distance of 12"
3.2 Programming and Control: Light fixtures incorporate high efficiency electronic power drivers and dimming drivers. Automatic adjustment of light intensity within the programmed range as low as
10% with LEDs, up to 100% of maximum intensity. Supplemental far red LED's are controlled in light levels.
7 Local Regulatory Codes: Equipment design and manufacture may not address all local, state or country-specific regulatory requirements including elements such as seismic anchoring, electrical configuration, or similar. Client to identify and advise of such requirements prior to issuance of a purchase order.
8 Light measurement at 12" (300mm), chamber temperature of 25°C. Light intensities are nominal values measured at the rated chamber supply voltage and (dimmable lighting) with a maximum light output (verified by a LI-190R factory reference Quantum Sensor). With fluorescent lamps, light intensity values may be lower than specified if measured at temperature set points below 25°C.
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
3.3 Fixtures: Broadband spectrum for plant growth using LED fixtures and supplemental far red
LED (730nm).
3.4 Canopies: Counterbalanced for adjustable light intensities - Lightright™.
3.5 Heat: Removed by refrigeration system.
3.6 Ballasts: High efficiency electronic.
3.7 Light Meter: The LI-190R replaces the traditional Quantum sensor, providing improved performance, high stability and greater sensitivity.
4.0 Temperature Control: (Maximum design ambient temperature is +35°C)
4.1 Range: -10°C to +35°C lights ON/OFF. Ultra low temperature operation enables the chamber to be operated with lights ON to -10°C (No fresh air below 8°C.) A defrost cycle will occur resulting in a temperature increase (spike) for temperatures set below +8°C lights ON/OFF. Temperature spikes (up to ±5°C) and defrost time are dependent on chamber operating temperature. During this cycle, the lights will be turned off (factory default). Reference section 4.5 below. Specified light intensity will be reduced when chamber is operating at low temperatures.
Note:
1) Chamber shall include drain pan, drain line and door heater(s). With additive humidity option, chamber shall also include purge function which requires low pressure air supplied to cabinet (35 psi)
2) With Ultra Low Temperature (ULT) option, observation window is unavailable.
3) For temperatures below +10°C, programming and control of fluorescent lighting shall be by independent, 4 level programming of light levels (8 level with M10T5 option).
4) Option adds 10" (255mm) to overall height of chamber (removable to pass through doorways).
4.2 Control : ±0.5°C, at control point.
4.3 Temperature Safety Limits:
Primary: A programmable min and max temperature or a limit tracking alarm that automatically follows the programmed set point.
Secondary: An independent factory-set high and low temperature limit is also provided for increased assurance.
Audible alarms are included based on user-defined limits.
4.4 Aspirator: Located in the growth area for accurate controlling and recording of chamber conditions.
4.5 Sequential Defrost. Sequential defrost, provided in conjunction with the LT or ULT option minimizes the temperature spike experienced with the standard defrost method used during low temperature operation. This is achieved by sequentially defrosting the evaporator coil in stages. Sequential Defrost does not require the chamber lights to turn OFF during the defrost cycle. Note: Machine compartment width increases by nominally 12" (305mm).
5.0 Refrigeration:
5.1 Condensing Unit: Cabinet is supplied with a water-cooled condensing unit with hot gas bypass system for continuous compressor operation and close temperature control. Condensing unit is located in the machine compartment, and includes a 3-way water modulating valve and hand operated shut off bypass valve. Maximum pressure drop across the condenser and water valve not to exceed 10psi (0.7 bar). Customer to provide water supply temperature. (Alternate cooling systems available)
9 Measured by NIST traceable calibrated temperature sensor without test materials or optional accessories
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
5.2 Valve: Electronic modulating 2-way stepper valve that smoothly regulates the temperature function of the chamber.
5.3 Heat Exchanger Coil(s): Copper-tube construction.
5.4 Refrigerant: Condensing unit is charged with CFC-free refrigerant.
5.5 Monitoring:
Refrigeration system operation monitored by control system, including visual and audible alarm.
Pressure transducers allow for real-time diagnostics for preventative maintenance and repair.
6.0 Air Flow:
6.1 Vertical: Uniform upward through Unifloor® less than 50ft/min (15.2m/min).
6.2 Fresh Air: Filtered inlet and adjustable exhaust to 20ft3/min (0.57m3/min).
7.0 Humidity Control: (Based on +21°C and 50% RH ambient condition10)
7.1 Range: Up to 90% RH lights OFF and 85% RH lights ON, limited by a +25°C maximum dew point (empty chamber).
7.2 Additive humidity through use of spray nozzles.
7.3 Control: ±3% RH. System uses a dry humidity sensor to directly measure humidity in %RH. Note:
When combined with high light option, maximum humidity level with lights ON is 75%RH. When combined with low temperature control, no control below 4°C.
8.0 Carbon Dioxide Additive Control: (Optional)
8.1 Range: No control on basic unit.
9.0 Utility Requirements : (rating increases with some options.)
9.1 Electrical Service: (Alternative services available, consult factory)
60Hz: 120/208-3-60Hz-4 wire plus ground
9.2 Drain: Floor drain must be provided outside footprint of cabinet.
9.3 Humidity System: Spray nozzles require a 60 psi (4.2 bar) pressure and must be supplied with reverse osmosis water. Water resistivity must be between 0.01 to 0.02 Meg ohm-cm (MO-cm).
Maximum water usage to maintain specified levels is 4 liters/hr. If the above water pressure is not available the CPSNH option is required to supply necessary pressure.
9.4 Provided with a U.S. electrical inspection by an inspection authority accredited by OSHA.
10.0 Warranty and After Sales Service:
10.1 Warranty and after sales service is handled by our dedicated team of service professionals. They provide a 24-hour manned service phone to facilitate any repair emergency. In addition, the team is available, during regular business hours, to assist with any service or warranty repairs, replacement parts or questions. Conviron also offers a fully trained international network of independent third party service providers who can affect repairs wherever your chamber is located.
10.1.1 Two year warranty (extended warranty optional).
10.2 To access this free support, please contact the service group at;
Phone: (204) 786-6451 Fax: (204) 786-7736 Toll Free: 1-800-363-6451
Email info@conviron.com www.conviron.com
11.0 Installation: As detailed on page 5-6.
10 Measured by NIST traceable calibrated temperature sensor without test materials or optional accessories.
11 This unit will tolerate ±10% voltage fluctuation from the rated voltage on the serial plate. A voltage stabilizer must be used if the fluctuation is greater than ±10%. Failure to do so can result in serious damage to the compressor and electronic components and will void warranty.
Disconnect switch must be sized by a local qualified electrician.
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
ISO 9001 Registered
CONFIDENTIAL
Controlled Environments Limited, Controlled Environments Inc., Conviron Europe Ltd., Conviron Science and Technology
(Shanghai) Co. Ltd., Conviron Asia Pacific PTY Ltd. and/or Argus Control Systems Ltd. (herein referred to collectively as
"Conviron") claims full ownership, property, design and marketing rights to the information and material herein disclosed. It is supplied in confidence and any reproduction, fabrication or re-communication of any nature or kind of the contents without the express prior written consent of Conviron is strictly prohibited.
PRICING INFORMATION
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
$ 111,840.00
$ 92,380.00
$ <17,200.00>
$ 3,160.00 ..........$ 3,470.00
$ 6,105.00 ..........$ 6,700.00
$ 9,515.00 ..........$ 10,445.00
Pricing for one (x1) only Conviron model PGW40 Plant Growth Chamber, including installation, as per specifications;
F.O.B. Destination: Logan, UT
Pricing for one (x1) only Conviron model PGR15 Plant Growth Chamber, including installation, as per specifications;
F.O.B. Destination: Logan, UT
Deduct if completed as a single mobilization of installation for one (x1) model PGW40 Plant Growth Chamber and one (x1) model PGR15 Plant Growth Chamber
Extended Warranty Options:
Conviron offers extended warranties on all its products. Extended warranties must be purchased at the time of the original product purchase to be eligible for the discounted warranty price shown.
Extended Warranties may be purchased at a later date for a non-discounted price provided it is within the
Standard Warranty period.
The following are prices for Extended Warranty offerings for the products forming the subject of this quotation (without Optional Accessories). For Extended Warranty pricing when Optional Accessories are included, please contact Conviron.
Model PGW40 Model PGR15
Standard 2-year warranty:............ Included................ Included
Warranty for 3rd year only:
Warranty for 3rd and 4th years only:
Warranty for 3rd, 4th and 5th years only:
Further details regarding Conviron's Standard Warranty and Extended Warranty are available on
Conviron's website at www.conviron.com, or by calling 1-800 363-6451 or 1-204-786-6451.
Preventative Maintenance & Service Program - GroGuardian™:
Conviron offers comprehensive preventative maintenance and service programs for its equipment.
Program frequency and structure are customized based on your requirements and desired level of service.
To learn more about GroGuardian™, please contact us at info@conviron.com
PRICING INFORMATION
© 2019 by Controlled Environments Limited. All rights reserved. Specifications Subject To Change Without Notice; E & OE
Shipping: Approximately 120-150 days from receipt of signed approval drawings (Model
PGW40). Approximately 120-150 days from receipt of order (Model PGR15).
Firm shipping date to be determined at time of order placement.
Note: Please ensure that a loading dock or fork lift is available for the delivery of this order. If neither is available, a lift gate truck12 can be arranged for an additional fee.
Order Submittal: Order processing, inquiries or additional questions may be forwarded through your account manager directly or through info@conviron.com.
Warranty and Terms and Conditions of Sale: This quotation, and any contract or purchase order resulting from this quotation, are deemed to incorporate, and in all circumstances are subject to, Conviron's 2 year warranty provisions (1-year on retrofits) and standard terms and conditions of sale. In the event that copies of these two documents are not enclosed with this quotation, they are available on Conviron's website at www.conviron.com, or by calling 1-800-363-6451 or (204) 786-6451.
BY:
CONTROLLED ENVIRONMENTS INC.
Graham Willson, C.I.M.
Account Manager
Lift Gate Availability: Customer supplied forklift required for lift gate assistance of crated dimensions greater than 6' (1.8m) in length or 2,000lbs
(907kg). Lift gate not available with full trailer load delivery.
mailto:info@conviron.com http://www.conviron.com/
| Specs 1 |
| Specs 2 |
File details come from the government source that posted it. Updated .