This document is a Technical Exhibit #1 Specifications for Evaluation and Submission Sheet for a construction project at the Federal Law Enforcement Training Center (FLETC) Glynco Campus in Georgia. The detailed specification lists extensive materials and requirements for a construction project, including structural, roofing, siding, electrical, plumbing, and bathroom fixtures. Key materials include lumber (spruce, pressure-treated), concrete (3000 PSI pump mix with fiber), rebar, metal siding, roofing components, electrical wiring and conduits, septic system materials, and six complete bathroom installations with ADA-compliant fixtures. The document emphasizes strict delivery requirements, with the government reserving the right to reject materials that do not meet specifications, and requiring replacement within 4 hours of delivery. Delivery is specifically to Track 2 at the FLETC Glynco Campus, with delivery personnel subject to security vetting.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TE 2 PROVISION AND CLAUSES FY25.pdf | ||
| TE 3 SECTION H FLETC LOCAL CLAUSES.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Submission for Meet or Exceeds
(Required for Submission: See TE #2 for Buy Terms)
Technical Exhibit #1: Specifications for Evaluation and Submission Sheet
Vendor must fill out Company’s name, POC, UEI, Date
Company Name:
POC:
Signature of Vendor:
Date:
UEI:
Failure to submit a complete submission sheet with vendor’s signature will be result in a not acceptable rating. The Governme Quantit y Unit of
Measure
IN EACH
Specifications salient characteristics. All specifications must be equal to the following specifications and/or salient characteristics presented
Offeror must reply to all areas in order to be evaluated by the government.
Any specification not addressed will be considered not acceptable.
Any areas deemed not acceptable will result in a overall rating of not acceptable and will not be eligible for award.
Technical
Customer
Evaluation
(Acceptabl e or Not
Acceptable na na Offeror must acknowledge all bullet points as an understanding of scope
• Furnish and deliver all listed supplies in the quantities and specifications described.
• Ensure all products meet or exceed ASTM and
American
Concrete
Institute
(ACI)
standards for structural and finishing materials.
• Provide
Material
Safety Data
Sheets
(MSDS) for all sealants, adhesives, and other chemical products.
• Coordinate all delivery scheduling with the
FLETC
Training
Support
Division to prevent disruption to ongoing training operations.
• All materials shall be delivered and staged to Track 2, FLETC Glynco
Campus, located at:
1131 Chapel
Crossing
Road, Glynco, GA
31524
• Delivery employee must be able to be vetted to gain access to
FLETC.
25 each
#5 rebar, 20′ lengths
42 LBS
Synthetic fiber additive
(polypropylene, 1.5 lb per cubic yard)
1800 SQ FT
Vapor barrier, 6-mil polyethylene
15 each 2×6×16 spruce (Must be straight). The government has the right to reject and require replacement within 4 hours if not acceptable at time of delivery.
50 each 2×4×16 spruce (Must be straight). The government has the right to reject and
100 each Tapcon concrete anchors, 3/8″ × 6″
150 each Tapcon concrete anchors, 1/4″ × 3″
375 each 2×4×104 5/8″ SPF precut studs
(Must be straight). Government has the right to reject and require replacement within 4 hours if not acceptable at time of delivery.
120 each 2×6×16 SPF studs (Must be straight).
Government has the right to reject and
35 each Pressure-treated 2×4 sill plates
160 Linear ft 3-1/2″ rigid insulation foam strips for under sill plates
1 each 4×4 post (treated) (Must be straight).
Government has the right to reject and
30 pounds Paslode 3″ framing nails (collated)
200 each Simpson Strong-Tie 6″ structural truss screws
17 trusses ROOF- Prefabricated wooden trusses, 5/12 pitch
55 sheets Roof sheathing, 5/8″ ZIP System panels, 4×8
8 rolls ROOF-ZIP System seam tape rolls.
54 bundles ROOF- Dimensional shingles, 30-year architectural (gray)
220 Linear ft ROOF- Drip edge (aluminum)
40 pounds ROOF- 2″ galvanized nails (collated)
55 SHEETS ZIP System wall sheathing, 4×10
1650 SQ FT R-panel metal siding, gray finish
200 Linear ft Black metal trim coil
3000 Sq ft Vinyl soffit panels (vented)
80 Linear ft J-channel for siding/windows
4 each Exterior siding corners, black finish
800 each Metal siding screws, #12 × 1-1/2″, gray, self-drilling with neoprene washers
300 each Painted-head trim and soffit screws, #8 × 1″, color-matched
24 TUBES Exterior-grade polyurethane sealant (tubes)
6 EACH Insulated exterior steel doors with locksets
2 EACH Black vinyl windows, 3′×5′
8 SETS Window/door trim kits
12 TUBES Silicone window/door caulk
170 sheets Interior 1/2″ drywall, 4×8
12 each Drywall joint compound -5 gallon
20 pounds Drywall screws
24 tubes construction adhesive (drywall grade, tubes)
25 each interior paint (eggshell, white) gallon
12 each Drywall tape
600 Linear ft base molding, 3-1/4″
280 Linear ft Window/door casing, 2-1/4″
10 pounds 2″ finish nails (collated, 15-gauge)
10 pounds 2-1/2″ finish nails (collated, 15-gauge)
24 tubes interior acrylic latex caulk (paintable)
12 tubes fire-rated sealant (intumescent caulk, red)
6 cans fire-block foam (expanding, orange)
The project include six (6) bathrooms. The following items below must be a package with coordinating colors to each other and eggshell colored walls and present a uniform appearance.
6 each BATHROOMS: ADA-compliant toilets Must fit into 5’X8” bathroom with vanity/sink combos
6 each BATHROOMS: toilet installation kits
6 units BATHROOMS: Vanity/sink combos with faucets
6 units BATHROOMS: Under-sink electric water heaters (2.5–4 gal)
6 units BATHROOMS: Bathroom exhaust fans with duct kits
6 units BATHROOMS: Bathroom mirrors
12 units BATHROOMS: ADA stainless steel grab bars
1 unit BATHROOMS: Bottle filling station with chilled water feature
600 LINEAR
FT
BATHROOMS: PEX supply line, 1/2″
200 Linear ft BATHROOMS: PEX supply line, 3/4″
120 Sets/pieces PEX fittings (elbows, tees, couplings)
300 LINEAR
PVC drain line, 3″
200 LINEAR
PVC drain line, 4”
6 SETS BATHROOMS: Sink traps and supply kits
6 SETS BATHROOMS: Toilet flanges and seals
6 SETS BATHROOMS: Sink traps and supply kits
1 UNIT Septic tank, 1,000-gal polypropylene (poly-pro)
4 RUNS Easy-Flow pipe, 50′ runs
40 TONS Septic sand for drain field
1 UNIT 200-amp breaker panel
20 UNITS 20A breakers
2500 LINEAR
FT
NM-B 12-2 cable (Romex)
500 LINEAR
FT
NM-B 10-2 cable (Romex)
80 UNITS 20A device boxes (new work)
80 UNITS 20A duplex receptacles, tamper-resistant
20 UNITS Switch boxes
20 UNITS Single-pole switches, 20A
100 UNITS Cover plates
20 FIXTURES Interior LED ceiling lights
4 FIXTURES Exterior LED wall-pack lights
500 LINEAR
FT
Conduit, fittings, clamps
6 UNITS Single-gang low-voltage boxes for
CAT6
500 Linear ft CAT6 Ethernet cable (plenum rated
1284 Sq ft Open-cell spray foam insulation – exterior 2×4 walls
1625 Sq ft Open-cell spray foam insulation – roof deck underside
12 Cubic
Yards For continuous footers (24”X12”) 3000 psi pump mix concrete with fiber no air, must arrive onsite at 4-inch slump. Concrete must be accepted by the government. All unacceptable concrete must be redelivered at no cost to the government. The government reserves the right to ask for rework with no extra charge to the government for concrete mix. The government will provide a 2-day notice for the delivery of the concrete mix onsite to the build area. The government will pour the concrete.
Contractor/driver must be able to be vetted through security. Delays at the gate is at no fault of the Government.
28 CUBIC
YARDS
For continuous footers (30X50) 3000 psi pump mix concrete with fiber no air, must arrive onsite at 4-inch slump. Concrete must be accepted by the government. All unacceptable concrete must be redelivered at no cost to the government. The government reserves the right to ask for rework with no extra charge to the government for concrete mix. The government will provide a 2-day notice for the delivery of the concrete mix onsite to the build area. The government will pour the concrete.
Contractor/driver must be able to be gate is at no fault of the Government.
1 job Finish concrete slab approximately 600 square feet to a smooth, slick finish using power trowel machine equipment.
The government will provide labor and equipment to place and level the concrete during the pour.
Contractor shall supply experienced finishers only for the final finishing application.
Finishers must be equipped with all tools, safety gear, and machine trowels necessary to deliver a high-quality, uniform surface suitable for all-weather exterior use.
This is considered incidental services completed by the Contractor.
Contractor must provide certified concrete finisher to ensure poured concrete is to required codes.
Government will provide oversight.
1 ea 20’ x 30’ red iron lean-to structure kit, complete with all framing hardware, pre-drilled components, and installation brackets
52 YARDS Fifty-two (52) yards of 3000 PSI pump mix concrete, small pea gravel mix. with fiber no air, must arrive onsite at 4-inch slump. Concrete must be accepted by the government. All unacceptable concrete must be redelivered at no cost to the government. The government reserves the right to ask for rework with no extra charge to the government for concrete mix. The government will provide a 2-day notice for the delivery of the concrete mix onsite to the build area. The government will pour the concrete.
Contractor/driver must be able to be gate is at no fault of the Government
15 Ea 2"x2"x16' spruce lumber boards (Must be straight). The government has the right to reject and require replacement within 4 hours if not
20 ea 2"x4"x16' spruce lumber boards the right to reject and require
12 ea 2"x6"x16' spruce lumber boards the right to reject and require
1 EA 25 lb bucket of 3" T25 Star Drive construction screws
16 EA 5/8" diameter x 20' length steel rebar rods
30 EA 3/4" diameter x 12" long threaded rods, Grade 8 steel
60 EA 3/4" nuts, compatible with the Grade 8 threaded rods
120 EA 3/4" washers, compatible with the Grade 8 threaded rods
10 EA 10-foot lengths of 1" EPVC conduit
100 EA 1/2" EPVC Schedule 40 conduit lengths
4 EA 1/2" EPVC male adapters
4 EA 1/2" steel locknuts
4 EA 1/2" plastic bushings
8 EA 1/2" EPVC couplings
3 EA 1/2" EPVC 90-degree elbows
1 EA 1/2" EPVC LB conduit body
1 EA SOD miniature circuit breaker
1 EA 2-gang 5-hole aluminum weatherproof box
1 EA extra-duty dual-gang weatherproof cover (vertical/horizontal configuration)
2 EA 1-gang 3-hole aluminum weatherproof boxes
2 EA extra-duty single-gang weatherproof covers (vertical/horizontal configuration)
100 EA 1/2" non-metallic conduit lengths
50 EA 1/2" EPVC two-hole straps
200 FT 1/4" x 2-1/4" Tap-Con masonry screws
500 FT 12 AWG green THHN stranded wire
500 FT 12 AWG black THHN stranded wire
500 FT 12 AWG white THHN stranded wire
12 EA 1/2" non-metallic straight sealtite connectors
12 EA 1/2" non-metallic 90-degree sealtite connectors
3 EA 4-foot selectable LED vapor-tight fixtures
2 EA wall-mounted AirEye directional fans, 30-inch blade diameter o Yellow blade color finish o 120V operation o OSHA-compliant fan screen o Integrated LED display with
AirEye power and motion detection activation o Noise reduction technology with three precision-balanced airfoils o Rated for wet locations and suitable for outdoor use