This document is a Technical Exhibit #1: Specifications for Evaluation and Submission Sheet for a federal contract opportunity involving construction materials and building services for the Federal Law Enforcement Training Center (FLETC). The procurement requires furnishing and delivering various construction materials including 30 premium spruce 2"x4"x16' lumber, moisture barrier, deck screws, nails, concrete sealant, threaded rods, nuts, and washers. Additional requirements include concrete services with 3000 psi pump mix concrete, concrete finishing services for 2,625 square feet, and the construction of a 35'x75' red-iron enclosed building with specific components.
The submission requires a comprehensive package including an HVAC package, electrical package, 10 gallons of fire retardant paint, and spray foam insulation for full building coverage. Contractors must meet ASTM and American Concrete Institute standards, provide Material Safety Data Sheets, coordinate delivery with FLETC Training Support Division, and ensure all materials and services meet government specifications. The document emphasizes that any unaddressed specifications or unacceptable materials will result in a non-acceptable rating and disqualification from the contract award. Vendors must complete the submission sheet with company details and vendor signature to be considered for evaluation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TE 2 PROVISION AND CLAUSES FY25.pdf | ||
| TE 3 SECTION H FLETC LOCAL CLAUSES.pdf | ||
| TE4 Additional Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Submission for Meet or Exceeds (Required for Submission: See TE #2 for Buy Terms)
Technical Exhibit #1: Specifications for Evaluation and Submission Sheet
Vendor must fill out Company’s name, POC, UEI, Date Company Name:
POC:
Signature of Vendor:
Date:
UEI:
Failure to submit this a complete submission sheet with vendor’s signature will be result in a not acceptable rating.
Line Item
Quantity & Unit of Measure
IN EACH
Specifications salient characteristics. All specifications must be equal to the following specifications and/or salient characteristics presented
Offeror must reply to all areas in order to be evaluated by the government. Any specification not addressed will be considered not acceptable. Any areas deemed not acceptable will result in a overall rating of not acceptable and will not be eligible for award.
Technical Customer Evaluation (Acceptable or Not Acceptable) na na Offeror must acknowledge all bullet points as an understanding of scope
• Furnish and deliver all listed supplies in the quantities and specifications described.
• Ensure all products meet or exceed ASTM and American Concrete Institute (ACI) standards for structural and finishing materials.
• Provide Material Safety Data Sheets (MSDS) for all sealants, adhesives, and other chemical products.
• Coordinate all delivery scheduling with the FLETC Training Support Division to prevent disruption to ongoing training operations.
30 each 2”x4”x16’ premium #2 & better spruce
1 ROLL
Moisture Barrier
• Film Poly Black, 6 mil, 40’ x 100’
1 BOX
Deck Screws, 3”, 25 lb, at least 300 in box
2 BOX Nails, Bright 30D, 0.12” x 3”, at least 2000 per box
6 each Concrete Sealant Drylok Wet Look High Gloss, 5 gallons each
40 each Grade 8 threaded rods, ¾” x 12”
80 each Grade 8 nuts, ¾”
160 Grade 8 washers, ¾”
70 Hull Design: Deep “V” with minimum 24-Degree deadrise Minimum
3000 psi pump mix concrete with fiber no air, must arrive onsite at 4-inch slump. Concrete must be accepted by the government. All unacceptable concrete must be redelivered at no cost to the government. The government reserves the right to ask for rework with no extra charge to the government for concrete mix. The government will provide a 2-day notice for the delivery of the concrete mix onsite to the build area. The government will pour the concrete.
Contractor/driver must be able to be vetted through security. Delays at the gate is at no fault of the Government.
1 job Concrete finishing services covering 2,625 square feet. This is considered incidental services completed by the Contractor. Contractor must provide certified concrete finisher to ensure poured concrete is to required codes.
Government will provide oversight.
1 ea Red-Iron Enclosed building 35’X75’ single slope.
2 walk doors:3/0-7/0 1 Insulated roll-up door 8x10. Seen additional details. TE#4 HVAC package. Seen additional details.
TE#4 for more details
1 Ea HVAC PACKAGE MUST BE INCLUDED. Contractor must provide all specifications and parts for evaluation. Seen additional details.
TE#4 HVAC package
1 Ea Electrical Package must be included.
Contractor must provide all specifications and parts for evaluation.
Seen additional details. TE#4 electrical package
10 ea Fire retardant paint 5 gallons. Uniform gray finish
1 ea Spray Foam Insulation. Contractor must provide all material, tools, equipment, and labor to fully insulate building. Installation is considered incidental.