Tech_Data_AA55110A.pdf
PDF 116 KB Posted
- Attached to
- Men's Air Force/Coast Guard All-Weather Coat
- Solicitation number
- SPE1C1-23-R-0031
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF30_SPE1C123R00310006.PDF | ||
| SF30_SPE1C123R00310005.PDF | ||
| SF30_SPE1C123R00310004.PDF | ||
| SF30_SPE1C123R00310003.PDF | ||
| SF30_SPE1C123R00310002.PDF | ||
| SF30_SPE1C123R00310001.PDF.pdf | ||
| AA_55110_AWC_Mens.pdf | ||
| AQAR.pdf | ||
| DLA Labeling and Packaging Requirements.pdf | ||
| BOM_AA55110_Sq__Inches.pdf | ||
| RFID_Guide.PDF |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COAT, ALL‐WEATHER, MAN'S WITH REMOVABLE LINER
RQ009: INSPECTION AND ACCEPTANCE AT ORIGIN
RP001: DLA PACKAGING REQUIREMENTS FOR PROCUREMENT
RA001: THIS DOCUMENT INCORPORATES TECHNICAL AND/OR QUALITY REQUIREMENTS (IDENTIFIED BY
AN 'R' OR AN 'I' NUMBER) SET FORTH IN FULL TEXT IN THE DLA MASTER LIST OF TECHNICAL AND
QUALITY REQUIREMENTS FOUND ON THE WEB AT:
http://www.dla.mil/HQ/Acquisition/Offers/eProcurement.aspx
FOR SIMPLIFIED ACQUISITIONS, THE REVISION OF THE MASTER IN EFFECT ON THE SOLICITATION ISSUE
DATE OR THE AWARD DATE CONTROLS. FOR LARGE ACQUISITIONS, THE REVISION OF THE MASTER IN
EFFECT ON THE RFP ISSUE DATE APPLIES UNLESS A SOLICITATION AMENDMENT INCORPORATES A
FOLLOW‐ON REVISION, IN WHICH CASE THE AMENDMENT DATE CONTROLS.
ADDITIONAL INFORMATION FOR A‐A‐55110A:
PATTERN DATE: 10 JUNE 2013
SAMPLE SIZE: 40 REG
THE FOLLOWING INFORMATION PERTAINS TO CLOTH
USED AS SHELL MATERIAL:
STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER AND
COTTON (WATER REPELLENT), CG BLUE SHADE 3376,
CONFORMING TO A‐A‐50531, IS AVAILABLE ON ROLL
NO. 113220, AND APPLICABLE FOR SHADE.
THE FOLLOWING INFO IS FOR CLOTH LINING MATERIAL
STANDARD SAMPLE FOR NYLON TAFFETA CLOTH, CG BLUE
SHADE 3376 IS AVAILABLE ON ROLL NO. 85018, AND
APPLICABLE FOR SHADE, FINISH AND COLORFASTNESS.
INTERIM CHANGES TO A‐A‐55110A:
PAGE 2, DESCRIPTION:
‐ PARA 1, LINE 2, AFTER "BACK," DELETE "A LINED"
‐ PARA. 1, LINE 3, AFTER "BACK YOKE," ADD "RIGHT
FRONT GUN FLAP,".
‐ PARA. 3, LINE 3, DELETE "STORM YOKE," INSERT "BACK YOKE, GUN FLAP"
PARA.3, AT THE END OF THE PARAGRAPH ADD THE
FOLLOWING: "AS AN ALTERNATE BELTS COULD BE TOP‐
STITCHED WITH A DOUBLE NEEDLE MACHINE. THE EDGE
STITCHING SHALL BE ONE‐SIXTEENTH (1/16) AND FIVE
SIXTEENTH INCH (5/16) FROM THE BELT EDGE."
‐PARA. 5, LINES 1 AND 2, DELETE "SQUARE‐OR
TAPERED END TYPE, "AND SUBSTITUTE "EYELET‐END
SQUARE BAR TYPE"
‐ PARA. 5, LINE 3, AFTER "UNDERSIDE.", ADD "THE
END OF THE BUTTONHOLE SHALL BE BARTACKED IN A
SEPARATE OPERATION FROM BUTTONHOLE MAKING,
SECURELY CATCHING THE ENDS OF THE GIMP COVERING
WIDTH OF THE BAR."
‐ AFTER PARA 5, INSERT THE FOLLOWING NEW PARAGRAPH: "FRONT FACING BAR TACKING ‐ THE FRONT
FACING SHALL BE TACKED USING A 1/2 INCH BARTACK POSITIONED AT THE POCKET BOTTOM (WHERE
POCKET AND FACING MEET) AND SHALL BE TACKED THROUGH THE FACING AND POCKET (NOT TO
INCLUDE THE SHELL).
PAGE 2, MATERIAL:
AT THE END OF THE PARAGRAPH ADD THE FOLLOWING SENTENCE:
'AS AN ALTERNATE, CLOTH SHALL BE SINGLE PLY,
65 PERCENT POLYESTER 35 COTTON POPLIN CLOTH
TESTED IN ACCORDANCE WITH TABLE II OF A‐A‐50531"
PAGE 3, AFTER PARA."BASIC MATERIAL" ADD
"TOXICITY. THE CLOTH SHALL SHOW NO TOXICITY WHEN
TESTED USING THE METHODS BELOW:
A) TITLE 40, CODE OF FEDERAL REGULATIONS, 1994
EDITION
SECTION 798.4100 ‐ DERMAL SENSITIZATION
SECTION 798.4470 ‐ PRIMARY DERMAL IRRITATION
SECTION 798.4500 ‐ PRIMARY EYE IRRITATION
MARZULLI, F & H. MAIBACH "CONTACT ALLERGY:
PREDICTIVE TESTING IN HUMANS",
ADVANCES IN MODERN TOXICOLOGY, VOLUME 4,
PG. 353‐372, 1977
B) AS AN ALTERNATIVE TO ANIMAL AND HUMAN TESTING
CERTIFIES THAT THE CLOTH IS COMPOSED OFCHEMICALS
AND/ORMATERIALS WHICH HAVE BEEN SAFELY USED
COMMERCIALLY WHERE PROLONGED SKIN CONTACT HAS
OCCURRED
PAGE 3, MATERIAL:
‐ PARA. 1, LINE 1, AFTER "THE MATERIAL FOR THE",
ADD "BACK SLEEVE LINING, FRONT SLEEVE LINING AND
THE".
‐ PARA. 2, AFTER "THE MATERIAL" INSERT "FOR THE REMOVABLE LINER"
‐ PARA. 2, LINE 2, DELETE "80 YARNS PER INCH
(MIN)" AND SUBSTITUTE "68 YARNS PER INCH (MIN)".
‐ PARA. 2, LINE 5, DELETE THE SENTENCE BEGINNING
WITH "THE FINISHED MATERIAL....." ENTIRELY AND
SUBSTITUTE THE FOLLOWING:
"THE FINISHED MATERIAL SHALL MATCH BLUE 3376 AND 'GOOD' FASTNESS TO PERSPIRATION
ACCORDING TO AATCC TEST METHOD 15
(THE TEST FOR COLORFASTNESS FOR ACID & ALKALINE
SOLUTION SHALL APPLY); WET DRY‐CLEANING ACCORD‐
ING TO FED‐STD‐191 METHOD 5622; LAUNDERING
ACCORDING TO AATCC TEST METHOD 61‐TEST 3A 1/ 2/;
AND A CROCKING RATING NOT LOWER THAN 3.0 ACCORD‐
ING TO AATCC‐TEST METHOD 8.
1/ THE SPECIMEN MUST BE DRIED AFTER EACH OF THE
THREE LAUNDERING CYCLES. THE SOAP SOLUTION
SHALL CONTAIN 0.5 PERCENT BY WEIGHT P‐D‐245
DETERGENT, LAUNDRY, AND HAND DISHWASHING
(GRANULAR) TYPE II, IN WATER HARDNESS NOT OVER
50 PARTS PER MILLION. THE WEIGHT OF THE
SPECIMEN SHALL BE 4.0 +/‐ 0.5 GRAMS AND THE
ROTATING TIME SHALL BE 30 MINUTES WITH TEN
STAINLESS STEEL BALLS IN EACH CYLINDER.
2/ FOR THE COLOR TRANSFER CLOTH EVALUATION,
ONLY THE STAIN ON THE COTTON FIBERS OF THE COLOR
TRANSFER CLOTH SHALL BE EVALUATED."
BEFORE "FUSIBLE INTERLINING" INSERT THE FOLLOWING PARAGRAPH, "Color matching. The color and appearance of the cloth shall match the standard sample when viewed using AATCC Evaluation
Procedure 9, Option A. Filtered tungsten lamps that approximate artificial daylight D75 illuminant having a color temperature of 7500 ± 200 K with illumination of 100 ± 20 foot candles shall be used. The color and appearance shall be a good match to the standard sample under Incandescent A light having a color temperature of 2854 ± 200 K."2
PAGE 3, FUSIBLE INTERLINING (NON‐WOVEN).LINE 1;
AFTER "THE TOP COLLAR", ADD "COLLAR STAND".
PAGE 3, FUSIBLE INTERLINING (NON‐WOVEN), PARA 1,
LINE 10, AFTER "BLACK" ADD "OR, AS AN ALTERNATE,
CHARCOAL".
PAGE 4:
‐ "FUSIBLE INTERLINING (WOVEN)". DELETE ITS ENTIRE
CONTENTS WITH NO SUBSTITUTION.
‐ "BUTTONS" PARAGRAPH, DELETE ENTIRELY AND
SUBSTITUTE THE FOLLOWING:
"BUTTONS. THE BUTTONS SHALL BE TYPE II, STYLE
20/21, PEARLESCENT‐POLYESTER COMPOSITION, 30 AND
40 LINE OF V‐B‐871 OR EQUAL. AS AN ALTERNATE, THE BUTTONS SHALL CONFORM TO TYPE II, CLASS D, MELAMINE FORMELDAHYDE COMPOSITION, STYLE 20/21, 30 AND 40 LINE, OF V‐B‐871.
THE COLOR SHALL BE BLUE BU, CABLE NO. 62002 AS SHOWN IN DEPARTMENT OF DEFENSE SHADES FOR
BUTTONS, 1966.
THE BUTTONS SHALL HAVE A GLOSSY FINISH.
THE REINFORCEMENT BUTTONS SHALL BE 18 LINE, TYPE II, STYLE 15, SHADE BLACK
OF V‐B‐871 OR EQUAL."
‐ "BUCKLES" PARAGRAPH, LINE 3, AFTER "EDGE.",
DELETE THE FOLLOWING SENTENCE AND SUBSTITUTE
"THE COLOR SHALL BE BLUE BU, CABLE NO. 62002,
WITH A MATTE FINISH." DELETE LAST SENTENCE OF
PARAGRAPH AND ALL BUCKLE DIMENSIONS & SUBSTITUTE
"THE NOMINAL DIMENSIONS SHALL BE IN INCHES AS
SPECIFIED BELOW:
. BELT SLEEVE STRAP
LENGTH (OUTSIDE) 2 1/2 1 1/2
WIDTH (OUTSIDE) 1 3/8 1 1/8
LENGTH (INSIDE) 1 7/8 1
WIDTH (INSIDE) 7/8 5/8
CENTER BAR WIDTH 1/4 1/8"
PAGES 6 & 7, MEASUREMENTS., IN "BELT LENGTH"
COLUMN FOR "SHORTS, REGULARS, & LONGS", OPPOSITE
SIZES 34 THROUGH 48, SUBTRACT 2 INCHES FROM EACH
MEASUREMENT.
PAGES 6 & 7, MEASUREMENTS, "SHORT" AT THE BOTTOM OF THE COLUMNS, ADD THE FOLLOWING
SIZES AND MEASUREMENTS:
50‐‐‐‐‐‐58‐‐‐‐‐‐17‐‐‐‐‐‐41‐1/4‐‐‐‐‐‐31‐1/4‐‐‐‐‐‐60‐1/2
52‐‐‐‐‐‐60‐‐‐‐‐‐17‐‐‐‐‐‐41‐1/2‐‐‐‐‐‐31‐1/2‐‐‐‐‐‐62‐1/2
54‐‐‐‐‐‐62‐‐‐‐‐‐17‐‐‐‐‐‐41‐3/4‐‐‐‐‐‐31‐3/4‐‐‐‐‐‐64‐1/2
"REGULAR" AT THE BOTTOM OF THE COLUMNS, ADD THE FOLLOWING SIZES AND MEASUREMENTS:
50‐‐‐‐‐‐58‐‐‐‐‐‐18‐‐‐‐‐‐43‐1/4‐‐‐‐‐‐33‐1/4‐‐‐‐‐‐60‐1/2
52‐‐‐‐‐‐60‐‐‐‐‐‐18‐‐‐‐‐‐43‐1/2‐‐‐‐‐‐33‐1/2‐‐‐‐‐‐62‐1/2
54‐‐‐‐‐‐62‐‐‐‐‐‐18‐‐‐‐‐‐43‐3/4‐‐‐‐‐‐33‐3/4‐‐‐‐‐‐64‐1/2
"LONG" AT THE BOTTOM OF THE COLUMNS, ADD THE FOLLOWING SIZES AND MEASUREMENTS:
50‐‐‐‐‐‐58‐‐‐‐‐‐19‐1/4‐‐45‐1/4‐‐‐‐‐‐35‐1/4‐‐‐‐‐‐60‐1/2
52‐‐‐‐‐‐60‐‐‐‐‐‐19‐1/4‐‐45‐1/2‐‐‐‐‐‐35‐1/2‐‐‐‐‐‐62‐1/2
54‐‐‐‐‐‐62‐‐‐‐‐‐19‐1/4‐‐45‐3/4‐‐‐‐‐‐35‐3/4‐‐‐‐‐‐64‐1/2
"EXTRA‐LONG" AT THE BOTTOM OF THE COLUMNS, ADD THE FOLLOWING SIZES AND MEASUREMENTS:
50‐‐‐‐‐‐58‐‐‐‐‐‐20‐‐‐‐‐‐47‐1/4‐‐‐‐‐‐37‐1/4‐‐‐‐‐‐60‐1/2
52‐‐‐‐‐‐60‐‐‐‐‐‐20‐‐‐‐‐‐47‐1/2‐‐‐‐‐‐37‐1/2‐‐‐‐‐‐62‐1/2
54‐‐‐‐‐‐62‐‐‐‐‐‐20‐‐‐‐‐‐47‐3/4‐‐‐‐‐‐37‐3/4‐‐‐‐‐‐64‐1/2
PAGE 9, UNDER "COMPONENT TESTING", DELETE ALL
REFERENCE TO "WOVEN INTERLINING FUSED TO BASIC
CLOTH" AND ITS ENTIRE CONTENTS.
PAGE 11, UNDER COLLAR, LAPEL, EPAULET, OR SLEEVE
STRAPS. ADD "EPAULET POINT MORE THAN 1/2 INCH
FROM GORGE OF NECK.
PAGE 14‐15, DELETE "PACKAGING," AND "PACKING" PARAGRAPHS IN THEIR ENTIRETY. AND INSERT THE
FOLLOWING: PACKAGING AND MARKING INSRUCTIONS
EACH COAT SHALL BE FOLDED TO APPROXIMATELY 14
INCHES BY 22‐1/2 INCHES. EACH FOLDED COAT SHALL
BE INSERTED INTO A CLOSE FITTING FLAT STYLE
CLEAR POLYETHYLENE BAG CONFORMING TO A‐A‐50083
THE BAG SHALL BE AT LEAST 1 INCH LONGER THAN THE
FOLDED COAT. THE UNSEALED OPENING OF THE BAG
SHALL BE AT THE SMALLER DIMENSION OF THE BAG
TEN COATS OF ONE SIZE ONLY, PACKAGED AS SPEC‐
IFIED, SHALL BE PACKED IN A SHIPPING CONTAIN‐
ER THAT IS ASSEMBLED AND CLOSED TO MIL‐B‐17757.
THE FIBERBOARD FOR THE LINERS SHALL CONFORM TO
TYPE CF, CLASS DOMESTIC, VARIETY DW, GRADE 275
OF PPP‐F‐320. EACH BAGGED COAT SHALL BE PACKED
FLAT, WITH EVERY OTHER COAT REVERSED TOP TO
BOTTOM WITHIN THE CONTENTS OF THE SHIPPING
CONTAINER. THE TOP AND THE BOTTOM OF THE CON‐
ENTS OF THE SHIPPING CONTAINER SHALL BE COM‐
PLETELY COVERED WITH WITH A SHEET OF 30 POUND
(MIN) BASIS WEIGHT PAPER CONFORMING TO A‐A‐203
PAGE 15, "MARKING," AFTER "MIL‐STD‐129," DELETE THE REMAINDER OF THE PARAGRAPH.
(Ref. W1958)
DELETE CURRENT "BARCODE LABEL/TAG" REQUIREMENTS AND SUBSTITUTE THE FOLLOWING:
LABEL TAG: EACH ITEM SHALL BE INDIVIDUALLY BAR‐CODED WITH A PAPER TAG FOR PERSONAL
CLOTHING ITEMS. THE PAPER USED FOR THE TAGS SHALL BE STANDARD BLEACHED SULFATE HAVING A
BASIS WEIGHT OF 100 POUNDS WITH A SMOOTH FINISH TO ACCEPT THERMAL TRANSFER AND DIRECT
PRINTING. THE TAGS SHALL HAVE A HOLE AND SHALL BE ATTACHED TO EACH ITEM BY A FASTENER, CLEARLY LEGIBLE AND READABLE BY SCANNER. THE BAR CODING ELEMENT SHALL BE A 13 DIGIT
NATIONAL STOCK NUMBER (NSN). THERE SHALL BE A 12 DIGIT UNIVERSAL PRODUCT CODE (UPC)
ASSIGNED FOR ALL NSNS BY THE GOVERNMENT. THE INITIAL "UPC" MUST APPEAR BENEATH THE CODE.
THE BAR CODES FOR NSN AND UPC SHALL BE A MEDIUM TO HIGH DENSITY AND SHALL BE LOCATED SO
THAT THEY ARE COMPLETELY VISIBLE ON THE ITEM WHEN IT IS FOLDED AND PACKAGED AS SPECIFIED.
THE LABEL'S LOCATION SHALL CAUSE NO DAMAGE TO THE ITEM.
NOTE: UNIVERSAL PRODUCT CODE INFORMATION THE GOVERMENT ASSIGNED UNIVERSAL PRODUCT
CODE (UPC) MUST BE PLACED ON ALL SHIPPING CARTONS ON WHICH THE NSN APPEARS.
THE FOLLOWING DEFECTS APPLY FOR BARCODE LABELS/TAGS:
BAR CODE OMITTED OR NOT READABLE BY SCANNER
HUMAN‐READABLE INTERPRETATION (HRI) OMITTED OR ILLEGIBLE
NOT VISIBLE ON FOLDED, PACKAGED ITEM CAUSES DAMAGE TO THE ITEM
NOTE: IF THE END ITEM IS PLACED IN A PLASTIC BAG ‐ USE TYPE VII (PRESSURE SENSTIVE LABEL) OF MIL‐
DTL‐32075.
IF THE END ITEM IS TIED IN A BUNDLE OR LEFT AS AN INDIVIDUAL ITEM, USE TYPE VIII (TAG, PAPER) OF
MIL‐DTL‐32075.
AQLS FOR COMMERCIAL ITEM DESCRIPTION (CIDS)
END ITEM DIMENSIONAL 2.5
VISUAL 4.0
PALLETIZATION 6.5
ACCEPTABILITY OF LOTS WILL BE DETERMINED BY THE
USE OF "SAMPLING PROCEDURES AND TABLE FOR
INSPECTION BY ATTRIBUTES". ANSI/ASQC Z1.4
GENERAL INSPECTION LEVEL II
(Ref. T7520)
ADDITIONAL INFORMATION FOR A‐A‐50531:
STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER
AND COTTON (WATER REPELLENT), ARMY BLACK 385
CONFORMING TO A‐A‐50531, IS AVAILABLE ON ROLL
NO. 3814, AND APPLICABLE FOR SHADE, FINISH AND
COLORFASTNESS.
STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER AND
COTTON (WATER REPELLENT), MARINE CORPS PEWTER
2246 CONFORMING TO A‐A‐50531, IS AVAILABLE ON
ROLL NO. 1208‐06, AND APPLICABLE FOR SHADE, FINISH
AND COLORFASTNESS.
STANDARD SAMPLE FOR CLOTH, POPLIN, POLYESTER
AND COTTON (WATER REPELLENT), COAST GUARD BLUE
3376 CONFORMING TO A‐A‐50531, IS AVAILABLE ON
ROLL NO. 113220 APPLICABLE FOR SHADE,
FINISH, AND COLORFASTNESS.
INTERIM SPECIFICATION CHANGES
TO A‐A‐50531:
PAGE 1, PARA. 1.1, GENERAL, AT THE END OF THE
PARAGRAPH, ADD THE FOLLOWING SENTENCE:
"AN ALTERNATE CLOTH SHALL BE A 1 PLY, 65 +/‐ 3
PERCENT POLYESTER AND 35 +/‐ 3 PERCENT
COTTON POPLIN CLOTH.
PARAGRAPH 1.2, PHYSICAL REQUIREMENTS, SECOND
LINE, AFTER "I", DELETE THE PERIOD AND ADD "AND
TABLE II."
TABLE I. CHANGE TITLE OF TABLE FROM "PHYSICAL
REQUIREMENTS" TO "BASIC CLOTH PHYSICAL
REQUIREMENTS" (2 PLY).
PAGE 2, TABLE I, BASIC CLOTH PHYSICAL REQUIRE‐
MENTS (2 PLY), UNDER TEST METHODS, DELETE "5550"
AND SUBSTITUTE "5556" FOR DIMENSIONAL STABILITY
TEST.
PAGE 3, BEFORE TABLE I FOOTNOTES, ADD THE
FOLLOWING NEW TABLE:
TABLE II. ALTERNATE CLOTH PHYSICAL REQUIREMENTS
(1 PLY)
CHARACTERISTICS REQUIREMENTS TEST METHOD
FIBER CONTENT 65% +/‐ 3% POLYESTER 2100 4/
. 35% +/‐ 3% COTTON 2100 4/
YARN PLY
. WARP SINGLES OR 2 PLY VISUAL 2/
. FILLING SINGLES VISUAL 2/
WEIGHT, OZ./SQ.
YD. 5.3‐6.8 ASTM D 3776 3/
YARNS PER INCH (MIN.)
. WARP 107 ASTM D 3775 3/
. FILLING 68 ASTM D 3775 3/
WEAVE PLAIN VISUAL 2/
AIR PERMEABILITY
(MAX.) 10 ASTM D 737.75 3/
BREAKING STRENGTH, LBS. (MIN.)
. WARP 185 ASTM D 1682 3/
. FILLING 70 ASTM D 1682 3/
TEARING STRENGTH, LBS. (MIN.)
. WARP 5.0 ASTM D 5034 3/
. FILLING 2.0 ASTM D 5034 3/
DIMENSIONAL STABILITY, PERCENT (MAX.)
. WARP 2.0 5556 4/
. FILLING(1 PLY) 3.0 5556 4/
COLORFASTNESS TO:
LAUNDERING
(3 CYCLES) GOOD 5610 4/ 5/
PERSPIRATION GOOD 5680
CROCKING
. WET 2.5 5651 AND
. DRY 2.5 AATCC 8 4/ 8/
LIGHT
(40 HOURS) GOOD 5660 4/
PH 5.0‐8.0 2811 4/
SPRAY RATING:
. INITIAL 100,100,90 5526 4/
. AFTER 3
LAUNDERINGS 70,70,70 5526 4/
. 1 DRY‐
CLEANING 70,70,70 5508 AND 5526 4/
DYNAMIC ABSORPTION, PERCENT (MAX.)
. INITIAL 18 5500 4/
. AFTER 3
. LAUNDERINGS 18 5556 AND 5500 4/ 7/
HYDROSTATIC PRESSURE
. CM. (MIN.)
. INITIAL 30 5514 4/
. AFTER 3
LAUNDERINGS
(COTTON METHOD) 25 5556 AND 5514 4/ 7/
. AFTER 1
DRY CLEANING 25 5508 ABD 5514 4/
RESISTANCE TO ORGANIC
LIQUID (MIN.)
. INITIAL NO WETTING AATCC 118 8/
. (N‐TETRADECANE)
. AFTER 3
LAUNDERINGS
(COTTON METHOD) NO WETTING 5556 AND 7/
. AATCC 118 8/
WATER REPELLENT 9/
THE FOLLOWING FOOTNOTES SHALL APPLY TO BOTH
TABLE I AND TABLE II."
PAGE 4, PARAGRAPH 1.3, PUT UP., LINE 2, DELETE
"50 AND SUBSTITUTE "40".
PAGE 8, UNDER "REVIEW ACTIVITY", ADD THE
FOLLOWING: "NAVY ‐ NU".
(Ref. T0495)
LIST OF APPROVED WATER REPELLENT TREATMENTS FOR MILITARY FABRICS 1/
THE FOLLOWING FLUOROCHEMICALS ARE APPROVED "DURABLE" TYPE WATER REPELLENT TREATMENTS
FOR USE ON MILITARY FABRICS. THEY MAY BE USED ALONE OR COMBINED WITH AN APPROVED
EXTENDER COMPONENT TO PRODUCE A "QUARPEL" TYPE OF WATER REPELLENT TREATMENT
REPELLENT TREATMENTS:
TRADE NAME SUPPLIER
AURAPEL FC‐340 AURALUX DIV OF SYBRON
CHEMICAL CO.
P.O. BOX 113
YANTIC, CT 06389
TEL: 860‐886‐2626
BARPEL 1700 APOLLO CHEMICAL CORP.
PO BOX 2176
BURLINGTON, NC 27215
TEL: 910‐226‐1161
CHEMSHIELD 939 CHEM‐TEX INC.
WR 930 P.O. BOX 1105
1891 N. COLUMBIA ST.
BLDG 106, MILLEDGEVILLE, GA 31061
TEL: 336‐578‐5476
FABRIC GUARD ML TANNER CHEMICAL CO., INC.
PO BOX 1967, FURMAN HALL
COURT, GREENVILLE, NC 29602
TEL: NO LISTING IN NC ON 800#
ZONYL B CIBA‐GEIGY CORP.
ZONYL D P.O. BOX 11422
ZONYL RN 2/ HIGHPOINT, NC 27409
ZONY 6700 TEL: 888‐396‐2488
ZONYL 6700 GF
ZONYL 7040
ZONYL 8300
ZONYL 8070
ZONYL DWR
ZONYL MIL
FC‐232 3M CORPORATION,
FC‐251 PROTECTIVE PRODUCTS DIV.
FC‐461 ST. PAUL, MN. 02895
FC‐831 TEL: 612‐737‐0098
REPEARL F‐14N MITSUBISHI INTERNATIONAL
REPEARL F‐35 520 MADISON AVE.
REPEARL F‐31 NEW YORK, NY 10022
TEL: 212‐605‐2440
800‐851‐5765
NK GUARD FG‐280 NICCA USA, INC.
P.O. BOX 1600
5000 NELSON ROAD
FOUNTAIN INN, SC 29644
TEL: 864‐862‐1426
SEQUAPEL CQR SEQUA CHEMICAL CORP.
SEQUAPEL NRL ONE SEQUA DRIVE
SEQUAPEL WOR CHESTER, SC 29807‐0070
SEQUAPEL WOR‐46 TEL: 803‐385‐5181
TEX‐TEL NI‐40 AUTO CHEMICAL CO.
THREE PARKWAY
PHILADELPHIA, PA 19102
TEL: 215‐419‐7000
UNIGUARD‐5061 UNICHEM INC.
P.O. BOX 612
916 W. MAIN ST.
HAW RIVER, NC 27258
TEL: 336‐578‐5476
FLUOROGARD 1700 PUTNAM INDUSTRIES, INC
197 RIDGEWOOD AVE.
GLEN RIDGE, NJ 07028
TEL: NOT LISTED
FLO CHEM EXTRA 17‐4 EMCO SERVICES INC.
P.O. BOX 2191
TAUNTON, MA 02780
TEL: 508‐823‐8852
1/ A SEPARATE LIST OF APPROVED WATER REPELLENT TREATMENTS EXISTS FOR FABRICS CONFORMING
TO CLOTH, CAMOUFLAGE PATTERN; WOODLAND, COTTON AND NYLON, CLASS 2, MIL‐C‐44031 AND
CLOTH, TWILL, CAMOUFLAGE PATTERN, COTTON AND NYLON FOR DESERT UNIFORM, CLASS 1A, MIL‐C‐
44034.
2/ FOR POLYESTER, NYLON AND BLENDS OF MANMADE FIBERS ONLY.
ADDITIONAL INFORMATION FOR A‐A‐55634A, 23 MARCH 2004:
SPECIAL NOTE!! ALL SLIDE FASTENERS USED ARE TO BE MEASURED FROM "STOP TO STOP".
RECOMMEND THAT THIS MEASUREMENT BE TAKEN RANDOMLY BEFORE SLIDE FASTENERS ARE SEWN
TO THE ITEMS, COVERALL, OR ANY ITEM REFERRED TO IN THE SOLICITATION. "THE QAR WILL REJECT
ANY SLIDE THAT IS NOT LAYING FLAT AFTER IT IS SEWN INTO/ONTO AN ITEM." SPECIAL INFO ON ITEMS
THAT UTILIZE SLIDE FASTENERS IS GIVEN BY "ALL USING MILITARY PERSONNEL".
V‐B‐871F Button, Sewing Hole, and Button, Staple, (plastic) has been canceled and is superseded by A‐
A‐59994 Button, Sewing Hole, and Button, Staple, (Plastic) dated 04 Dec 2018
No Information Follows
ADDITIONAL INFO FOR NN‐P‐71: NO ADDITIONAL INFORMATION FOLLOWS..
(Ref. T0829 ‐ 9/11/06)
"MIL‐DTL‐32075: LABEL FOR CLOTHING, EQUIPAGE,
AND TENTAGE, GENERAL USE REPLACES DDD‐L‐20
(Ref. T0451 ‐ June 19, 2007)
INTERIM SPECIFICATION CHANGES TO MIL‐DTL‐32075:
PAGE 6, TABLE I, "PHYSICAL REQUIREMENTS OF THE
TYPE VI FINISHED LABEL." UNDER "TEARING
STRENGTH" DELETE: "(LB.) MINIMUM" AND
SUBSTITUTE: "(GNS) MINIMUM."
PAGE 12, PARA 3.3.2.17, AFTER "NSN" ADD
"AND THE UNIVERSAL PRODUCT CODE (UPC)
SUPPLIED BY THE GOVERNMENT, FOR ALL NSNs."
ADDITIONAL INFORMATION FOR MIL‐P‐15011:
NO ADDITIONAL INFORMATION FOLLOWS.
(ref. T1368 ‐ 6/15/06)
ADDITIONAL INFORMATION FOR MIL‐I‐45208:
NOTE: MIL‐I‐45208 HAS BEEN CANCELLED AND REPLACED BY THE FOLLOWING: INTERNATIONAL
STANDARDS ISO 9001:2008
OR AMERICAN SOCIETY FOR QUALITY ASQ 2008 VERSION.
(ref. T1286 )
ADDITIONAL INFORMATION FOR FED‐STD‐191:
FED‐STD‐191A NOTICE 7, DATED AUGUST 9, 2000 IS HEREBY INACTIVE FOR NEW DESIGN. WHEN NOT
USING FED‐STD‐191, SEE INTERIM CHANGES TO END ITEM SPECIFICATION FOR REPLACEMENT ASTM.
INTERIM CHANGES TO FED‐STD‐191A:
TEST METHOD 5202, PARA. 5.3, DELETE FIRST SENTENCE AND SUBSTITUTE: "THE SPECIMEN SHALL BE
CLAMPED FIRMLY, WITH ONE END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT ONE INCH
OF SPECIMEN LIES WITHIN THE CLAMP AND ONE INCH OF THE SPECIMEN EXTENDS BEYOND THE
CENTER OF ROTATION (FACE OF THE VISE), AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE
DIAL PLATE".
TEST METHOD 5309.1 ABRASION RESISTANT OF TEXTILE WEBBING. PAGE 1, PARA 4.1.2,LINE 4: DELETE
"B‐97" AND SUBSTITUTE "B‐91".
THE FOLLOWING METHODS ARE IDENTIFIED AS SPECIFYING OZONE DEPLETING SUBSTANCES: 1100, 1200, 1240, 1400, 1410, 1500, 1510,1520,1530, 1540, AND 1550. PARA 5.1 OF THESE TEST METHODS
REQUIRE THE USE OF 1,1,1‐ TRICHLOROETHANE, ALCOHOL OR ETHER. 1,1,1‐TRICHLORETHANE IS AN
OZONE DEPLETING SUBSTANCE (METHYL CHLOROFORM) AND IS THEREFORE PROHIBITED. THE USE OF
EITHER ALCOHOL OR ETHER IS REQUIRED WHEN THESE METHODS ARE IN BASIC OR ANY REFERENCED
DOCUMENT.
METHOD 5202, STIFFNESS OF CLOTH, DIRECTIONAL; CANTILEVER BENDING METHOD. PAGE 2, PARA. 5.3
DELETE FIRST SENTENCE AND SUBSTITUTE WITH THE FOLLOWING: "THE SPECIMEN SHALL BE CLAMPED
FIRMLY, WITH 1 END FLUSH WITH THE OUTER EDGE OF THE VISE, SUCH THAT 1" OF THE SPECIMEN LIES
WITHIN THE CLAMP AND 1" OF THE SPECIMEN EXTENDS BEYOND THE CENTER OF ROTATION (INNER
FACE OF THE VISE) AND WITH THE LONG EDGE PARALLEL TO THE FACE OF THE DIAL PLATE."
METHOD 5556.1, MOBILE LAUNDRY EVALUATION FOR TEXTILE MATERIALS, PAGE 5, PARA. 5.2.2, LINE 8:
DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS ENTIRETY AND SUBSTITUTE
WITH THE FOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE SEPARATED, OPENED TO FULL WIDTH
AND PLACED IN A PRE‐HEATED DRYER HAVING A STACK TEMPERATURE OF 140‐180 DEG. F. THIS
TEMPERATURE RANGE CORRESPONDS TO A SETTING OF "HIGH" ON THE TEMPERATURE INDICATOR ON
THE DRYER. DRYING SHALL CONTINUE FOR 45‐60 MINUTES OR UNTILSAMPLES ARE DRY IN A ROTATING
TUMBLE DRYER."
PAGE 5, PARA. 5.2.3, LINE 8: DELETE SENTENCE BEGINNING WITH "THE SPECIMENS AND BALLAST" IN ITS
ENTIRETY AND SUBSTITUTE WITH THEFOLLOWING: "THE SPECIMENS AND BALLAST SHALL BE
SEPARATED, OPENED TO FULL WIDTH AND PLACED IN A PRE‐HEATED DRYER HAVING A
STACKTEMPERATURE OF 140‐180 DEG. F. THIS TEMPERATURE RANGE CORRESPONDS TO A SETTING OF
"HIGH" ON THE TEMPERATURE INDICATOR ON THE DRYER. DRYING SHALL CONTINUE FOR 35‐40
MINUTES OR UNTIL SAMPLES ARE DRY."
METHOD 5931, ELECTROSTATIC DECAY OF FABRICS; DETERMINATION OF PAGE 1, PARA. 3: AFTER
NUMBER OF DETERMINATIONS ADD "PER SAMPLE UNIT". PAGE 1, PARA. 4: DELETE "APPARTUS" AND
SUBSTITUTE "APPARATUS". PAGE 1, PARA. 5.1, LINE 3: AFTER "AT" DELETE"APPROXIMATELY".
PAGE 2, PARA. 5.2, LINES 2, AND 5: AFTER "OF" ADD "+‐". LINE 6: AFTER "TO" ADD "+‐".
PAGE 2, PARA. 5.3: DELETE IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:"5.3 MOUNT A
SPECIMEN TIGHTLY ACROSS THE ELECTRODES, CENTERING IT OVER THE SENSOR OPENING. THE
SURFACE OF THE TEST SPECIMEN (BACK OR FRONT) SHALL FACE THE SENSOR. RECORD (OPTIONAL) THE
RESIDUAL CHARGE LEVEL ON THE SAMPLE AS SEEN BY THE SENSOR, INCLUDING POLARITY.
NOTE THAT TEST SAMPLES WITH THE RESIDUAL CHARGE LEVELS OF LESS +500 VOLTS YIELD THE BEST
RESULTS. APPLY +5000 VOLTS TO THEELECTRODES FOR A PERIOD OF 20 SECS. AT THE END OF THE 20
SECOND PERIOD, THE HIGH VOLTAGE (5000 VOLTS) SHALL BE TURNED OFF ANDTHE SPECIMENS
IMMEDIATELY GROUNDED. THE VOLTAGE BEHAVIOR OF THE SPECIMEN WITH RESPECT TO TIME SHALL
BE PLOTTED ON THE RECORDER. NOTE: IN SOME CASES, THE TEST EQUIPMENT WILL DISPLAY VOLTAGE
AND DECAY TIME INFORMATION AND A CHART RECORDER IS NOT NECESSARY."
PAGE 2, PARA. 5.4, LINE 3: DELETE SENTENCE BEGINNING WITH "IF THE SPECIMEN DID" IN ITS ENTIRETY.
PAGE 2, PARA. 5.5: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING:
"RECORD THE MAXIMUM VOLTAGE LEVEL(INCLUDING POLARITY) AND DECAY TIME TO 10% OF THE
MAXIMUM VOLTAGE LEVEL ACHIEVED."
PAGE 2, PARA. 5.6, LINE 1: ADD THE FOLLOWING PRIOR TO 1ST SENTENCE: "REVERSE VOLTAGE
POLARITY REPEAT MEASUREMENT, ANDRECORD RESULTS."
PAGE 3, PARA. 6.6: DELETE PARAGRAPH IN ITS ENTIRETY AND SUBSTITUTE WITH THE FOLLOWING: "THE
AVERAGE TIME TO DECAY TO 10%OF THE MAX VOLTAGE SHALL BE INCLUDED FOR EACH OF THE WARP
& FILLING DIRECTIONS, AS WELL AS THE OVERALL AVERAGE, FOR EACHFABRIC TESTED. THESE WILL BE
OBTAINED BY AVERAGING THE TEST RESULTS (ABSOLUTE VALUE OF) TOGETHER FOR BOTH
VOLTAGEPOLARITIES. UNLESS OTHERWISE STATED IN THE REQUIREMENTS DOCUMENT, THE FABRIC
SHALL BE CONSIDERED ACCEPTABLE IF THEAVERAGE MAXIMUM VOLTAGE IN BOTH THE WARP AND
FILLING DIRECTIONS IS LESS THAN 4000 VOLTS, AND THE AVERAGE DECAY TIME (TO 10% MAXVOLTAGE)
IS GREATER THAN 0.5 SECONDS IN BOTH THE WARP AND FILLING DIRECTIONS. IT SHALL BE INDICATED
WHETHER THE FABRIC ISACCEPTABLE OR NON‐ACCEPTABLE."
PAGE 3, PARA. 7.1, SECOND COLUMN, LINE 2: DELETE 406C AND SUBSTITUTE WITH "406D".
AFTER PARA. 7.1, ADD THE FOLLOWING: "7.2 NOTE: IF THE MODEL 406D STATIC DECAY METER, OR
EQUIVALENT, IS USED, A CHART RECORDER ISNOT MANDATORY FOR THE TEST."
(Ref. T0215)
MIL‐STD‐129R w/CHANGE 2 ‐ DEPARTMENT OF DEFENSE STANDARD PRACTICE MILITARY MARKING FOR
SHIPMENT AND STORAGE
DATED: 27 SEPTEMBER 2019
INTERIM CHANGES:
OMISSION OF MARKINGS ON EXTERIOR SHIPPING CONTAINERS OF ITEMS
IN THE DLA TROOP SUPPORT CLOTHING AND TEXTILE (C&T) DIRECTORATE:
THE NOMENCLATURE AND MANUFACTURER'S NAME (WHEN THE NAME IDENTIFIES THE MATERIAL)
SHALL BE OMITTED FROM ALL EXTERIOR SHIPPING CONTAINERS OF DLA TROOP SUPPORT C&T ITEMS, REGARDLESS OF MODE OF SHIPMENT.
IF THE MANUFACTURER'S NAME DOES NOT IDENTIFY THE MATERIAL AS BEING CLOTHING, IT MAY
REMAIN. NSNS SHALL BE SHOWN ON ALL SHIPPING CONTAINERS OF C&T ITEMS, THE PACKING LIST
SHALL BE PLACED INSIDE THE LAST CONTAINER TO BE LOADED FOR EACH SHIPMENT. THE WORDS
"PACKING LIST HERE" SHALL BE STENCILED, NOT HAND LETTERED, ON THE CONTAINER.
MIL‐STD‐147E w/CHANGE 2
27 JUNE 2019
DEPARTMENT OF DEFENSE
STANDARD PRACTICE
PALLETIZED UNIT LOADS
File details come from the government source that posted it. Updated .