TE 20 - Cathodic Protection System Preventive Maintenance Checklist.xlsx
XLSX spreadsheet 21 KB Posted
- Solicitation number
- W5168W23R0004
- Issued by
-
Department of the Army
About this file
This document contains a cathodic protection system preventive maintenance checklist template. It lists various buildings and structures across a military base and includes fields to record outputs, settings, potentials, manufacturers, and water levels during routine maintenance checks of cathodic protection systems. Related to this is a solicitation from the Department of the Army seeking base operation support services at Yuma Proving Ground in Arizona. The support services solicitation includes requirements for general base operations and facility management, maintenance, engineering, environmental services, and other functions to support the military mission at the base. The response deadline and anticipated award date are not provided.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Table 1
| TECHNICAL EXHIBIT 20 | |||||
| CPS PREVENTIVE MAINTENANCE CHECKLIST | |||||
| SATISFACTORY | |||||
| YES | NO | ||||
| OUTPUT DC VOLTS | |||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | |||
| LOCATION | HCA | SET POTENTIAL | |||
| MANUFACTURE | REFERENCE POTENTIAL | ||||
| BUILDING | |||||
| NUMBER | 460 | WATER LEVEL AT TIME OF |
READING
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | HCA | SET POTENTIAL | ||
| MANUFACTURE | REFERENCE POTENTIAL | |||
| BUILDING NUMBER | 461 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | HCA | SET POTENTIAL | ||
| MANUFACTURE | UNIVERSAL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 1098 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | HCA | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 1099 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | MTD | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 2350 | WATER LEVEL AT TIME OF READING |
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | UST FUEL | RECTIFIER TAP SETTING | ||
| LOCATION | LAAF | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 3003 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | UST FUEL | RECTIFIER TAP SETTING | ||
| LOCATION | LAAF | SET POTENTIAL | ||
| MANUFACTURE | UNIVERSAL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 3004 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | LAAF | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 3006 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | LAAF | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | WT 280 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | LAAF | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | WT 281 | WATER LEVEL AT TIME OF READING |
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | KFR | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 3480 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | KFR | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 3526 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | KFR | SET POTENTIAL | ||
| MANUFACTURE | UNIVERSAL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 3563 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | CDA | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | WT 600/6002 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | CDH | SET POTENTIAL | ||
| MANUFACTURE | REFERENCE POTENTIAL | |||
| BUILDING NUMBER | 6082 | WATER LEVEL AT TIME OF READING |
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | CDH | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 6086 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | W.T.O | RECTIFIER TAP SETTING | ||
| LOCATION | AIR CARGO | SET POTENTIAL | ||
| MANUFACTURE | GOODALL | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | 2957 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | BIN WALLS | RECTIFIER TAP SETTING | ||
| LOCATION | KFR | SET POTENTIAL | ||
| MANUFACTURE | GALVANIC | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | GP 23.1 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | BIN WALLS | RECTIFIER TAP SETTING | ||
| LOCATION | KFR | SET POTENTIAL | ||
| MANUFACTURE | GALVANIC | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | HEX 11.1 | WATER LEVEL AT TIME OF READING | ||
| SATISFACTORY | ||||
| YES | NO | |||
| OUTPUT DC VOLTS | ||||
| CRAFT | BIN WALLS | RECTIFIER TAP SETTING | ||
| LOCATION | KFR | SET POTENTIAL | ||
| MANUFACTURE | GALVANIC | REFERENCE POTENTIAL | ||
| BUILDING NUMBER | GP 5 | WATER LEVEL AT TIME OF READING |