TE 1 List of Facilities with Range Hoods.xlsx
XLSX spreadsheet 24 KB Posted
- Solicitation number
- W9124M22R0019
About this file
This document is a solicitation for cleaning and inspection services of kitchen hood exhaust systems and fire suppression systems at Fort Stewart and Hunter Army Airfield in Georgia. The solicitation seeks quarterly cleaning and semiannual inspections of various kitchen hoods and fire suppression systems as detailed in an attached technical exhibit. Quotes are due by September 7, 2022 and shall be submitted electronically. The contract will be a firm-fixed price agreement with a one year base period and four one-year options exercisable by the Army. The solicitation is set aside entirely for small businesses classified under NAICS code 561790 with a size standard of $8 million. The Department of the Army Materiel Command Mission and Installation Contracting Command is the contracting agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W9124M22R0019P00001 Solicitation Amendment SF 30.pdf | ||
| W9124M22R0019P00001 Solicitation Comformed SF 1449.pdf | ||
| TE3 Range Hoods CLINs Summary.xlsx | XLSX spreadsheet | |
| TE1 List of Facilities with Range Hoods -Update1.xlsx | XLSX spreadsheet | |
| TE 4 Accident form.pdf | ||
| W9124M22R0019 Range Hood Solicitation Combined.pdf | ||
| TE 5 FSGA Spill Plan.pdf | ||
| TE 2 Sample Form.pdf | ||
| TE 6 Pass Form.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Technical Exhibit #1
| TECHNICAL EXHIBIT # 1 | |||||||||||||||||
| Bldg | Description | Small | Medium | Frequency Interval for Cleaning | Frequency Interval for Inspection | Fire Suppression System Type | MFG | Model | Ser. No. | Last hydro test | Due hydro test | Fans | Horizontal Runs | Side Wall Fans | Pitched roof section | Legend: | column A lists the building number of the facility. Column B lists the type of facility. Columns C & D list the number and approx. size of the range hood systems present in that facility. Column G lists the type of fire suppression system, and column L lists when each FSS is due for hydrstatic testing. |
| FORT STEWART | |||||||||||||||||
| 207 | Dining Facility | 1 | 4 | Quarterly | 6 mos | 4 | |||||||||||
| 8.5 X 4.5 | wet 3 gal | Puro chem | PCL 300 | 283585 | 2016 | 2027 | |||||||||||
| 16.5 X 4.5 | wet 4.6 gal | Puro chem | PCL 460 | 280012 | 2016 | 2027 | |||||||||||
| 26.0 X 4.5 | wet 3 gal | Puro chem | PCL 300 | 283608 | 2019 | 2030 | |||||||||||
| 26.0 X 4.5 | wet 3 gal | Puro chem | PCL 300 | 215310 | 2015 | 2026 | |||||||||||
| 11.5 X 4.5 | wet 3 gal | Puro chem | PCL 300 | 276523 | 2016 | 2027 | |||||||||||
| 512 | Dining Facility | 5 | 4 | Quarterly | 6 mos | 7 | x | ||||||||||
| 5 X 7 | wet 3 gal | Ansul | R102 | S060321 | 2015 | 2026 | |||||||||||
| 5 X 7 | wet 3 gal | Ansul | R102 | S104137 | 2015 | 2026 | |||||||||||
| 5 X 7 | wet 3 gal | Ansul | R102 | S069428 | 2015 | 2026 | |||||||||||
| 5 X 7 | wet 3 gal | Ansul | R102 | S104131 | 2015 | 2026 | |||||||||||
| 5 X 7 | wet 3 gal | Ansul | R102 | S104363 | 2015 | 2026 | |||||||||||
| 4 X 15.5 | wet 3 gal | Ansul | R102 | S104127 | 2015 | 2026 | |||||||||||
| 4 X 15.5 | wet 3 gal | Ansul | R102 | S074352 | 2015 | 2026 | |||||||||||
| 4 X 15.5 | wet 3 gal | Ansul | R102 | R371397 | 2015 | 2026 | |||||||||||
| 4 X 15.5 | NONE | ||||||||||||||||
| 726 | Dining Facility | 4 | 5 | Quarterly | 6 mos | 8 | |||||||||||
| 16 X 4 | wet 3 gal | Puro chem | PCL 300 | 352951 | 2018 | 2029 | |||||||||||
| 16 X 4 | wet 3 gal | Puro chem | PCL 300 | 253009 | 2018 | 2029 | |||||||||||
| 16 X 4 | wet 6 gal | Puro chem | PCL 600 | 343455 | 2018 | 2029 | |||||||||||
| 16 X 4 | wet 3 gal | Puro chem | PCL 300 | 343460 | 2018 | 2029 | |||||||||||
| 16 X 4 | wet 6 gal | Puro chem | PCL 600 | 356887 | 2015 | 2026 | |||||||||||
| 4 X 8 | wet 3 gal | Puro chem | PCL 300 | 352981 | 2018 | 2029 | |||||||||||
| 4 X 8 | wet 3 gal | Puro chem | PCL 300 | 353013 | 2018 | 2029 | |||||||||||
| 4 X 8 | wet 3 gal | Puro chem | PCL 300 | 352992 | 2018 | 2029 | |||||||||||
| 4 X 8 | wet 3 gal | Puro chem | PCL 300 | 352985 | 2018 | 2029 | |||||||||||
| 3003 | Dining Facility | 5 | 5 | Quarterly | 6 mos | 7 | |||||||||||
| 5 X 7 | wet 1.5 gal | Ansul | R102 | 101838 | 2017 | 2028 | |||||||||||
| 5 X 10 | NONE | ||||||||||||||||
| 5 X 10 | NONE | ||||||||||||||||
| 5 X 7 | wet 1.5 gal | Ansul | R102 | 103157 | 2017 | 2028 | |||||||||||
| 5 X 4.5 | NONE | ||||||||||||||||
| 5 X 12 | wet 3 gal | Ansul | R102 | 103132 | 2017 | 2028 | |||||||||||
| 5 X 12 | wet 3 gal | Ansul | R102 | 2019 | 2030 | ||||||||||||
| 5 X 12 | wet 3 gal | Ansul | R102 | 103075 | 2019 | 2030 | |||||||||||
| 5 X 12 | wet 3 gal | Ansul | R102 | 100711 | 2017 | 2028 | |||||||||||
| 13 X 5 | NONE | ||||||||||||||||
| 8439 | Dining Facility | 6 | 5 | Quarterly | 6 mos | 10 | x | ||||||||||
| 5 X 7 | NONE | ||||||||||||||||
| 5 X 7 | NONE | ||||||||||||||||
| 5 X 7 | NONE | ||||||||||||||||
| 5 X 5 | wet 3 gal | Ansul | R102 | 154039 | 2022 | 2033 | |||||||||||
| 5 X 5 | wet 3 gal | Ansul | R102 | 154042 | 2022 | 2033 | |||||||||||
| 5 X 5 | wet 3 gal | Ansul | R102 | 154035 | 2022 | 2033 | |||||||||||
| 10 X 5 | NONE | ||||||||||||||||
| 11 X 5 | NONE | ||||||||||||||||
| 11 X 5 | NONE | ||||||||||||||||
| 28 X 5 | wet 3 gal | Ansul | R102 | 154044 | 2022 | 2033 | |||||||||||
| 28 X 5 | wet 3 gal | Ansul | R102 | 154043 | 2022 | 2033 | |||||||||||
| 19225 | Dining Facility | 2 | 2 | Quarterly | 6 mos | x | |||||||||||
| 4 X 4.5 | wet 3 gal | Ansul | R102 | R503940 | 2018 | 2029 | |||||||||||
| 4.5 X 5.5 | |||||||||||||||||
| 17.5 X 4.75 | wet 3 gal | Ansul | R102 | R503943 | 2018 | 2029 | |||||||||||
| 17.5 X 4.75 | |||||||||||||||||
| 19104 | Dining Facility | 6 | Semi | 6 mos | 4 | x | |||||||||||
| 4.5 X 10 | *used for exercises only | wet 3 gal | Ansul | R102 | 2021 | 2031 | |||||||||||
| 4.5 X 10 | wet 3 gal | Ansul | R102 | 2021 | 2031 | ||||||||||||
| 4.5 X 10 | wet 3 gal | Ansul | R102 | 2021 | 2031 | ||||||||||||
| 4.5 X 10 | NONE | ||||||||||||||||
| 4.5 X 5.5 | wet 3 gal | Ansul | R102 | 2021 | 2031 | ||||||||||||
| 4.5 X 5.5 | wet 3 gal | Ansul | R102 | 2021 | 2031 | ||||||||||||
| 455 | Burger King | 2 | Monthly | 6 mos | 2 | ||||||||||||
| 4 X 4 | wet 3 gal | Ansul | R102 | S108579 | 2014 | 2025 | |||||||||||
| 3 X 7 | wet 3 gal | Ansul | R102 | S219533 | 2014 | 2025 | |||||||||||
| 703 | Popeye's | 2 | Monthly | 6 mos | 2 | ||||||||||||
| 5 X 3 | wet 3 gal | Ansul | R102 | S135519 | 2016 | 2027 | |||||||||||
| 5 X 3 | wet 3 gal | Ansul | R102 | S135510 | 2016 | 2027 | |||||||||||
| 71 | PX Food Court | 6 | Monthly | 6 mos | 6 | ||||||||||||
| 5 X 4 | wet 3 gal | Ansul | R102 | 150243 | 2014 | 2025 | |||||||||||
| 5 X 4 | wet 3 gal | Pyro chem | PCL 300 | 180163 | 2014 | 2025 | |||||||||||
| 5 X 2 | NONE | ||||||||||||||||
| 5 X 4 | wet 3 gal | Pyro chem | PCL 300 | 180184 | 2014 | 2025 | |||||||||||
| 4 X10 | NONE | ||||||||||||||||
| 2 X 3 | |||||||||||||||||
| 419 | Panda Express | 1 | Monthly | 6 mos | 1 | ||||||||||||
| 8 x 8 | wet 3 gal | Ansul | R102 | 143000 | 2014 | 2025 | |||||||||||
| 402 | Marne Lanes | 1 | Monthly | 6 mos | 1 | ||||||||||||
| 14 x 5.5 | wet 4.6 gal | Puro Chem | PCL 460 | 238797 | 2015 | 2026 | |||||||||||
| 450 | Stewart Lanes | 1 | Monthly | 6 mos | 1 | x | |||||||||||
| 15 x 5.5 | wet 3 gal | Ansul | R102 | 128538 | 2020 | 2031 | |||||||||||
| 405 | Club Stewart | 6 | Quarterly | 6 mos | 2 | x | |||||||||||
| 12 x 4.5 | wet 3 gal | Ansul | R102 | 2022 | 2033 | ||||||||||||
| 12 x 4.5 | wet 3 gal | Ansul | R102 | 2022 | 2033 | ||||||||||||
| 12 x 4.5 | wet 3 gal | Ansul | R102 | 2022 | 2033 | ||||||||||||
| 12 x 4.5 | wet 3 gal | Ansul | R102 | 2022 | 2033 | ||||||||||||
| 12 x 4.5 | wet 3 gal | Ansul | R102 | 2022 | 2033 | ||||||||||||
| 12 x 4.5 | wet 3 gal | Ansul | R102 | 2022 | 2033 | ||||||||||||
| 403 | CDC | 1 | 6 mos | 6 mos | 1 | x | |||||||||||
| 6 x 4 | wet 3 gal | Puro chem | PCL 300 | 276515 | 2016 | 2027 | |||||||||||
| 475 | CDC | 1 | 6 mos | 6 mos | 1 | x | |||||||||||
| 4 x 10 | wet 3 gal | Ansul | R102 | 222776 | 2019 | 2030 | |||||||||||
| 5500 | CDC | 1 | 6 mos | 6 mos | 1 | x | |||||||||||
| 4.5 x 7 | wet 1.5 gal | Ansul | R102 | S269754 | 2013 | 2024 | |||||||||||
| 5655 | Youth center | 1 | 6 mos | 6 mos | 1 | x | x | ||||||||||
| 8.5 x 4.5 | wet 3 gal | Ansul | R102 | 20101028347 | 2021 | 2031 | |||||||||||
| 2 x 3 | Dry 1 gal | Gaurdian III | GIII | 2021 | 2031 | ||||||||||||
| 7100 | CDC | 1 | 6 mos | 6 mos | 1 | x | |||||||||||
| 4 x 7 | wet 1.5 gal | Ansul | R102 | S268691 | 2013 | 2024 | |||||||||||
| 7160 | Youth Center | 2 | 6 mos | 6 mos | 2 | x | |||||||||||
| 5.5 x 7 | wet 3 gal | Ansul | R102 | 20101028347 | 2021 | 2031 | |||||||||||
| 2 x 3 | Dry 1 gal | Gaurdian III | GIII | 2021 | 2031 | ||||||||||||
| 7338 | Youth Center | 2 | 6 mos | 6 mos | 2 | x | |||||||||||
| 5.5 x 7 | wet 3 gal | Ansul | R102 | 20101028347 | 2021 | 2031 | |||||||||||
| 2 x 3 | Dry 1 gal | Gaurdian III | GIII | 2022 | 2033 |
| HAAF | |||||||||||||||
| Bldg | Description | Small | Medium | Frequency Interval for Cleaning | Frequency Interval for Inspection | Fire Suppression System | MFG | Model | Ser. No. | Last hydro test | Due hydro test | ||||
| 110 | Dining Facility | 3 | 2 | Quarterly | 6 mos | 5 | x | ||||||||
| 9.5 x 4.5 | wet 3 gal | Pyro chem | PCL 300 | 166832 | 2014 | 2025 | |||||||||
| 4.5 x 5.5 | wet 3 gal | Pyro chem | PCL 300 | 193263 | 2014 | 2025 | |||||||||
| 4 x 7 | wet 3 gal | Puro chem | PCL 300 | ||||||||||||
| 30.5 x 4.5 | wet 4.6 gal | Puro chem | PCL 460 | 157840 | 2013 | 2024 | |||||||||
| 30.5 x 4.5 | wet 4.6 gal | Pyro chem | PCL 460 | 165878 | 2014 | 2025 | |||||||||
| 931 | Popeye's | 1 | Monthly | 6 mos | 1 | x | |||||||||
| 12 x 3 | wet 3 gal | Ansul | R102 | S117723 | 2016 | 2027 | |||||||||
| 148 | CDC | 1 | 6 mos | 6 mos | 1 | x | |||||||||
| 4.5 x 7 | wet 1.5 gal | Ansul | R 102 | 284577 | 2020 | 2031 | |||||||||
| 8805 | CDC | 1 | 6 mos | 6 mos | 1 | x | |||||||||
| 4.5 x 8 | wet 3 gal | Ansul | R102 | 205587 | 2019 | 2030 | |||||||||
| 8807 | YDC | 2 | 6 mos | 6 mos | 2 | x | |||||||||
| 2 x 3 | Dry 1 gal | Gaurdian III | GIII | 2022 | 2033 | ||||||||||
| 4.5 x 8 | wet 3 gal | Ansul | R102 | s264519 | 2021 | 2031 | |||||||||
| 6054 | Youth Center | 2 | 6 mos | 6 mos | 2 | x | |||||||||
| 2 x 4 | wet 1.5 gal | Ansul | R102 | s305966 | 2021 | 2031 | |||||||||
| 5 x 7 | wet 3 gal | Ansul | R102 | 20101233605 | 2021 | 2031 | |||||||||
| CURRENTLY CLOSED | |||||||||||||||
| 642 | Dining Facility | 4 | 4 | Quarterly | 6 mos | 8 | |||||||||
| 4 X 10 | wet 3 gal | Ansul | R102 | S223184 | 2019 | 2030 | |||||||||
| 4 X 11 | |||||||||||||||
| 4 X 10 | wet 3 gal | Ansul | R102 | S223183 | 2019 | 2030 | |||||||||
| 4 X 11 | |||||||||||||||
| 4 X 15.5 | wet 3 gal | Ansul | R102 | S223177 | 2019 | 2030 | |||||||||
| 4 X 15.5 | |||||||||||||||
| 4 X 15.5 | wet 3 gal | Ansul | R102 | S223174 | 2019 | 2030 | |||||||||
| 4 X 15.5 | |||||||||||||||
| 1280 | Bowling Alley | 1 | Monthly | ||||||||||||
| 5 x 16 | wet 3 gal | Ansul | R 102 | 126722 | 2020 | 2031 | 1 | ||||||||
| 6020 | Empty | 2 | Monthly | 2 | x | ||||||||||
| 7 x 3 | wet 3 gal | Ansul | R102 | 51966 | 2014 | 2025 | |||||||||
| 4 x 4 | wet 3 gal | Ansul | R102 | 69826 | 2014 | 2025 | |||||||||
| 6020 | Empty | 1 | Monthly | 1 | |||||||||||
| 4 x 5 | NONE | ||||||||||||||
| 1284 | CDC | 2 | 6 mos | 6 mos | x | ||||||||||
| 4 x 8 | wet 3 gal | Ansul | R 102 | 346905 | 2010 | 2021 | 1 | ||||||||
| 3.5 x 6 | NONE | ||||||||||||||
| Hunter club has been removed until that system is replaced. | x | x | |||||||||||||
| This is a list of the buildings with range hoods and their approximate sizes. |