TCTO 11957. WMEC-270 CPP FILTRATION SYSTEM REPLACE SOW Parts - Revised.docx
DOCX document 20 KB Posted
- Attached to
- WMEC-270 OEM CPP FILTRATION SYSTEM REPLACE
- Solicitation number
- 52000QR260023877
About this file
This is a Statement of Work (SOW) for TCTO 11957 addressing the replacement of obsolete components in the WMEC-270 fleet's Coordinated Pump and Proportioning (CPP) filtration system. The work encompasses procurement and shipment of 15 line items consisting of Parker Hannifin filtration components and related parts, including duplex filters, tube fittings, weld fittings, process fitting bodies, angle steel, pipe flanges, seal kits, split flange halves, screws, weld socket block connectors, check valves, socket head caps, lock washers, and O-rings. The total quantities range from 1 to 12 units per line item depending on the part type. All materials must be shipped to USCG Yard 2401 Hawkins Point Road, Baltimore, Maryland 21226 with a period of performance from November 1, 2026 to November 30, 2026.
The related solicitation (52000QR260023877) is issued by the Department of Homeland Security US Coast Guard Surface Force Logistics Center as a Request for Quote under FAR Part 12 for commercial items. This is a firm-fixed-price acquisition processed through simplified acquisition procedures. The requirement is restricted to Parker Hannifin products only due to compatibility, standardization, and lifecycle support considerations, with no substitutions permitted. Offerors must be authorized vendors and provide proof of authorized source status through a valid Letter of Authorization from Parker Hannifin. The NAICS code is 336611 with a small business size standard of 1,300 employees, and small business sources are eligible to submit proposals.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Statement of Work (SOW) For parts TCTO 11957. WMEC-270 CPP FILTRATION SYSTEM REPLACE
1. Background and Current Observed Issues Within aging WMEC 270 fleet it was discovered that an indicated the differential relief valve, Parker Hannifin, PN: RDC-40-15a, is no longer supported and ESD Supply is requesting a replacement. After further research, it was determined the CPP filter system as well is no longer supported. This filtration system applies to both A & B class.
2. REFERENCES
N/A
3. REQUIREMENTS
Purchase and shipment of exact items listed in the table below
| Line |
| Part Number |
| Description |
| Quantity |
| UOM |
| 1 |
| 32PD110QBPKG201 |
| PARKER HP IN-LINE DUPLEX FILTER |
| 8 |
| EA |
| 2 |
| 20 A4OEQ1-S |
| PARKER SPECIAL TUBE FITTING NS |
| 12 |
| EA |
| 3 |
| 20 HW-SS |
| PARKER WELDLOK FITTING - NS |
| 6 |
| EA |
| 4 |
| 24-20 TRW-SS |
| PARKER PROCESS FITTING BODY |
| 6 |
| EA |
| 5 |
| 9017K734 |
| MMC LOW CAR STEEL 90 DEG ANGLE (10 FT Length) |
| 3 |
| EA |
| 6 |
| 20W5Q1PSXK |
| PARKER FLAT FACE PIPE FLANGE |
| 12 |
| EA |
| 7 |
| S02373 |
| PARKER SEAL KIT |
| 12 |
| EA |
| 8 |
| 20FCS1S |
| PARKER CD61 SPILT FLNG HALF ZINC |
| 12 |
| EA |
| 9 |
| 91290A516 |
| MCM SCREW SHC M10 X 1.5 X 20 MM (Pack of 25) |
| 1 |
| PK |
| 10 |
| 24W5Q1BSX |
| PARKER FLAT WELD SOCKET BLOCK CONN (1-1/2" Flat Weld Socket) |
1-1/2" FLAT WELD SOCKET BLOCK CONNECTOR PIPE FLAT WELD
SOCKET PIPE CODE 61 BLOCK FLANGE OR PAD O-RING FACE
STEEL OIL DIPPED
| 6 |
| EA |
| 11 |
| C5V12310B1 |
| PARKER VALVE CHECK - IRON |
| 6 |
| EA |
| 12 |
| 24W5Q1PSX |
| PARKER FLAT WELD SOCKET BLOCK CONN (1-1/2" Flat Weld Socket) |
1-1/2" FLAT WELD SOCKET BLOCK CONNECTOR PIPE FLAT WELD
SOCKET PIPE CODE 61 BLOCK FLANGE OR PAD O-RING FACE
STEEL OIL DIPPED
| 6 |
| EA |
| 13 |
| 91251A730 |
| Black-Oxide Alloy Steel Socket Head Cap (Pack of 5) |
| 1 |
| PK |
| 14 |
| 5185N115 |
| MMC STEEL SPLIT LOCK WASHER (Pack of 10) |
| 1 |
| PK |
| 15 |
| 3-924 NBR |
| PARKER 90 DUROMETER O-RING |
| 12 |
| EA |
4. PERIOD OF PERFORMANCE
i. 1NOV26 to 30NOV26
5. PLACE OF PERFORMANCE
The components will be shipped to the location below:
USCG Yard 2401 Hawkins Point Rd Baltimore, MD 21226
Contracting Officer Technical Representative (COR):
Attention: LT. Aaron Benson – TCTO SPEC Writer Office: 206-820-3212 Email: Aaron.D.Benson@uscg.mil
File details come from the government source that posted it. Updated .