Text version
AutoCAD SHX Text
AutoCAD SHX Text
S.S. FASTENERS W/EXPANSION
AutoCAD SHX Text
SLEEVES AT NOT TO EXCEED
AutoCAD SHX Text 12" O.C.
AutoCAD SHX Text
METAL CAP
AutoCAD SHX Text
CONT. CLEAT
AutoCAD SHX Text
TAPERED INSUL.
AutoCAD SHX Text
FLASHING
AutoCAD SHX Text
MET. CAP
AutoCAD SHX Text
SPLICE PLATE SET IN SEALANT
AutoCAD SHX Text
6" LONG CONCEALED BENT
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
NO SLOTTED HOLE
AutoCAD SHX Text
@ CENTER - FIXED
AutoCAD SHX Text
POSITION
AutoCAD SHX Text
S.S. SCREWS W/ NEOPRENE
AutoCAD SHX Text
WASHERS IN SLOTTED
AutoCAD SHX Text
HOLE COVERED W/ SEALANT.
AutoCAD SHX Text
DO NOT SET SCREW FOR
AutoCAD SHX Text
EXPANSION
AutoCAD SHX Text
SYMMETRICAL LAYOUT ABOVE EACH ELEVATION
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
W/ SPRAY-ON INSUL.
AutoCAD SHX Text
PIPE. FILL VOID
AutoCAD SHX Text
ROOF PLAN M-1
AutoCAD SHX Text
AS CALLED FOR ON
AutoCAD SHX Text 3"%%c OR 4"%%c PIPE
AutoCAD SHX Text
EXISTING WALL
AutoCAD SHX Text
1/2" LARGER THAN
AutoCAD SHX Text
TO RECEIVE PIPE
AutoCAD SHX Text
CORE DRILL CMU
AutoCAD SHX Text
FOR ON ROOF PLAN
AutoCAD SHX Text
PIPE AS CALLED
AutoCAD SHX Text
#1760 SIZE FOR
AutoCAD SHX Text
NOZZLE J. R.. SMITH
AutoCAD SHX Text
BRASS DOWNSPOUT
AutoCAD SHX Text
ROOF DRAIN SEE MECH.
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
UNDER DECK CLAMP
AutoCAD SHX Text
MIN. 1" SPRAY INSULATION
AutoCAD SHX Text
W/ VAPOR BARRIER 7 FIRE
AutoCAD SHX Text
PROTECTION EXTEND 2'-0"
AutoCAD SHX Text
FROM CENTERLINE OF DRAIN
AutoCAD SHX Text
INSULATED DRAIN PIPE
AutoCAD SHX Text
FLEXIBLE EPDM FLASHING
AutoCAD SHX Text
BAR ANCHOR AND APPROVED
AutoCAD SHX Text
FASTENER
AutoCAD SHX Text
HIGH PROFILE EDGE CAULK
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
TAPERED INSUL.
AutoCAD SHX Text
EXISTING CONC. WALL
AutoCAD SHX Text
FLEXIBLE EPDM FLASHING
AutoCAD SHX Text
BAR ANCHOR AND APPROVED
AutoCAD SHX Text
FASTENER
AutoCAD SHX Text
HIGH PROFILE EDGE CAULK
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
TERMINATION BAR
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
HIGH PROFILE EDGE CAULK
AutoCAD SHX Text
TAPERED INSUL.
AutoCAD SHX Text
S.S. CLAMPING RING
AutoCAD SHX Text
WATERSTOP
AutoCAD SHX Text
PREFAB. PIPE BOOT
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
TYPICAL CONCRETE PARAPET DETAIL
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
TYP. CONC. ROOF/WALL JUNCTION DETAIL
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
PLAN OF CAP FLASHING SPLICE DET.
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
ROOF DRAIN DET.
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
DOWNSPOUT DET.
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
PREFAB. PIPE
AutoCAD SHX Text
WATERSTOP
AutoCAD SHX Text
CLAMPING RING
AutoCAD SHX Text
TAPERED INSUL.
AutoCAD SHX Text
HIGH PROFILE EDGE
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
COL. EXTENSION DEMO AT ROOF F
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
VAPOR BARRIER
AutoCAD SHX Text
TAPERED INSUL.
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
REMOVE EXIST. CONC
AutoCAD SHX Text
CAP, COLUMN BARS,
AutoCAD SHX Text
& 4 T.C. FLUSH TO
AutoCAD SHX Text
CONC. DECK
AutoCAD SHX Text 2A
AutoCAD SHX Text A3
AutoCAD SHX Text
REGLET
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
VERIFY EXISTING
AutoCAD SHX Text
CONC. PARAPET
AutoCAD SHX Text
VARIES - IF MORE THAN 3' SEE DET. 2/A3 FOR ROOFING
AutoCAD SHX Text
TERMINATION DEATILS, AND PROVIDE CAP FLASHING
AutoCAD SHX Text
EXISTING CONC.
AutoCAD SHX Text
WALL
AutoCAD SHX Text
W/S.S. ANCHORS
AutoCAD SHX Text
NOT TO EXCEED
AutoCAD SHX Text
12" 0.C. TYP.
AutoCAD SHX Text
VAPOR BARRIER
AutoCAD SHX Text
TURN UP WALL & OVER
AutoCAD SHX Text
TOP OF INSULATION
AutoCAD SHX Text
MINIMUM 12" TYPICAL
AutoCAD SHX Text
EXISTING CONC. DECK
AutoCAD SHX Text
EPDM
AutoCAD SHX Text
FLASHING
AutoCAD SHX Text
ADHESIVE
AutoCAD SHX Text
WATER STOP
AutoCAD SHX Text
FILL VOIDS COMPLETELY
AutoCAD SHX Text
W/ SPRAY-ON URETHANE
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
BACKER ROD (PCEFS) PRECOMPRESSED EXPANDING
AutoCAD SHX Text
FOAM SEALANTS.
AutoCAD SHX Text
EXIST. REGLET, REMOVE EXIST. REGLET FILLER & FLASHING
AutoCAD SHX Text
TERMINATION BAR
AutoCAD SHX Text
S.S. SCREWS W/ EXPAN. SLEEVE, SIZE AND
AutoCAD SHX Text
SPACING AS RECOMMENDED BY ROOFING
AutoCAD SHX Text
MEMBRANE MANUFACTURER.
AutoCAD SHX Text
CAULKING AS RECOMMENDED BY
AutoCAD SHX Text
ROOFING MEMBRANE MANUF.
AutoCAD SHX Text
EXISTING CONC. DECK
AutoCAD SHX Text
BAR ANCHOR NOT TO EXCEED
AutoCAD SHX Text 48" 0.C.
AutoCAD SHX Text
TOP OF PARAPET
AutoCAD SHX Text
MATCH SIZE OF
AutoCAD SHX Text
EXISTING AND NEW
AutoCAD SHX Text
PARAPETS. ALUMINUM
AutoCAD SHX Text
OR STAINLESS STEEL
AutoCAD SHX Text
BACKSIDE OF
AutoCAD SHX Text
PARAPET
AutoCAD SHX Text
PROVIDE CONTINUOUS CLEAT
AutoCAD SHX Text
1/4" X 8" SQ. ALUM. BASE PLATE WELDED
AutoCAD SHX Text
TO PIPE
AutoCAD SHX Text
(4) 1/2" BOLTS W/ EXPANSION SLEEVES
AutoCAD SHX Text
EXISTING CONC. DECK
AutoCAD SHX Text
VAPOR BARRIER
AutoCAD SHX Text
4" ROUND ALUMINUM OR
AutoCAD SHX Text
S.S. PIPE SUPPORT
AutoCAD SHX Text
EXIST. CONDENSER ANGLE LEG OR STAIR ANGLE
AutoCAD SHX Text
LEG, PROVIDE 3/8" BASE PLATE WELDED TO
AutoCAD SHX Text
BOTTOM OF ANGLE LEGS, BOLT W/ 3/4" BOLT
AutoCAD SHX Text
3/8" ALUMINUM CAP
AutoCAD SHX Text
WELD WATER TIGHT
AutoCAD SHX Text
TO PIPE, TACK
AutoCAD SHX Text
WELD 3/4" NUT
AutoCAD SHX Text
TO BOTTOM SIDE
AutoCAD SHX Text
VARIES
AutoCAD SHX Text 2"
AutoCAD SHX Text
PIPE SUPPORT DET. AT EXIST.
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
CONDENSER & EXIST. STEEL STAIR
AutoCAD SHX Text 1 1/2"=1'-0"
AutoCAD SHX Text
NOTE: 4, PIPE SUPPORTS REQUIRED AT EXIST. CONDENSER.
AutoCAD SHX Text
4, PIPE SUPPORTS REQUIRED AT EXISTING STEEL STAIR.
AutoCAD SHX Text
MODIFY LENTGH OF ANGLE LEGS AT STAIR TO SUIT NEW
AutoCAD SHX Text
ROOF HEIGHTS, AND UPPER LANDING LOCATION.
AutoCAD SHX Text 1"
AutoCAD SHX Text
SPRAY ON INSUL. (1" MIN.
AutoCAD SHX Text
THICK) W/ VAPOR BARRIER
AutoCAD SHX Text
& PROTECTION EXTEND
AutoCAD SHX Text
CENTERLINE OF PIPE
AutoCAD SHX Text
SET FLANGE
AutoCAD SHX Text
IN CAULKING
AutoCAD SHX Text
MIN 3" THICK TAPERED
AutoCAD SHX Text
INSUL. AT ROOF
AutoCAD SHX Text
DRAIN UNLESS
AutoCAD SHX Text
NOTED OTHERWISE
AutoCAD SHX Text
PROVIDED 5/8"
AutoCAD SHX Text
W/R GWB AT ROOF
AutoCAD SHX Text
D EXISTING PLYWOOD
AutoCAD SHX Text
DECK AND AT ROOF
AutoCAD SHX Text
H, I, AND J EXISTING
AutoCAD SHX Text
METAL DECK
AutoCAD SHX Text
OVERFLOW DRAIN AND
AutoCAD SHX Text
VAPOR
AutoCAD SHX Text
BARRIER
AutoCAD SHX Text
EXISTING STRUCTURAL
AutoCAD SHX Text
CONC. DECK ROOF A, B, C,
AutoCAD SHX Text E, F & G
AutoCAD SHX Text
NOTE: OVERFLOW DRAIN SIMILAR.
AutoCAD SHX Text
LOCATE OVERFLOW DRAIN UP
AutoCAD SHX Text
SLOPE 2" HIGHER THAN ROOF
AutoCAD SHX Text
DRAINS.
AutoCAD SHX Text
BOOT
AutoCAD SHX Text
CAULK
AutoCAD SHX Text
EXIST. VENT THRU
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
EXIST. STAND PIPE
AutoCAD SHX Text
FOR SIAMESE FIRE
AutoCAD SHX Text
CONNECTION
AutoCAD SHX Text
VAPOR BARRIER
AutoCAD SHX Text
EXIST. STRUCTURAL
AutoCAD SHX Text
DECK
AutoCAD SHX Text
NOTE: STAND PIPE FOR EXISTING SIAMESE
AutoCAD SHX Text
FIRE CONNECTION SIMILAR DETAIL.
AutoCAD SHX Text
EXISTING CONC.
AutoCAD SHX Text
DECK
AutoCAD SHX Text
KEYED NOTES A-3
AutoCAD SHX Text
1. ROUTE OSB BOARD W/ROUTER TO RECIEVE DRAIN,
AutoCAD SHX Text
TO PROVIDE SMOOTH TRANSITION FROM THE ROOF
AutoCAD SHX Text
SURFACE TO THE CLAMPING RING
AutoCAD SHX Text
3/4" HEMED
AutoCAD SHX Text
EDGE
AutoCAD SHX Text
VAPOR BARRIER
AutoCAD SHX Text %%p37.67 ELEV.
AutoCAD SHX Text
REF. NO.
AutoCAD SHX Text
STATE:
AutoCAD SHX Text
CITY:
AutoCAD SHX Text
STREET:
AutoCAD SHX Text
GS-
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REGION 10 - AUBURN, WA.
AutoCAD SHX Text
DESIGN & CONSTRUCTION DIVISION
AutoCAD SHX Text
PUBLIC BUILDINGS SERVICE
AutoCAD SHX Text
GENERAL SERVICES ADMINISTRATION
AutoCAD SHX Text Electrical
AutoCAD SHX Text Mechanical
AutoCAD SHX Text Structural
AutoCAD SHX Text Architectural
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
NAME
AutoCAD SHX Text
ADDRESS
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CKD.BY
AutoCAD SHX Text
DRAWN BY
AutoCAD SHX Text
TITLE
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
DRAWING
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
SEQUENCE
AutoCAD SHX Text
SERIES
AutoCAD SHX Text
TYPE
AutoCAD SHX Text A-E
AutoCAD SHX Text
GS-
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
CONTRACT
AutoCAD SHX Text
CONSTRUCTION
AutoCAD SHX Text A-3
AutoCAD SHX Text 27-177
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
ARCHITECTURAL
AutoCAD SHX Text
DETAILS I
AutoCAD SHX Text 10/10/92
AutoCAD SHX Text
WH
AutoCAD SHX Text
SJB
AutoCAD SHX Text
RAK 21393A
AutoCAD SHX Text
ROOFING REPLACEMENT
AutoCAD SHX Text
FEDERAL BUILDING
AutoCAD SHX Text
BLDG. # AK0005AK
AutoCAD SHX Text
KETCHIKAN
AutoCAD SHX Text
AK
AutoCAD SHX Text
MILL ST & STEDMAN ST
AutoCAD SHX Text
FEDERAL BUILDING, KETCHIKAN
AutoCAD SHX Text
EXIST. CONC. DECK
AutoCAD SHX Text
TAPERED INSUL.
AutoCAD SHX Text
EXIST. CONC. WALL
AutoCAD SHX Text
EPDM MEMBRANE
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
AutoCAD SHX Text A3
AutoCAD SHX Text
ALTERNATE CONCRETE ROOF/WALL JUNCTION DETAIL
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
APPROVED FASTENER, TYP
AutoCAD SHX Text
SEALANT, AS RECOMENDED BY ROOFING MANUFACTURER
AutoCAD SHX Text
STAINLESS STEEL FASTENER W/ NEOPRENE WASHER
AutoCAD SHX Text
REGLET
AutoCAD SHX Text
FLASHING
AutoCAD SHX Text
CANT STRIP, AS RECOMENDED BY ROOFING MANUFACTURER
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
NOTE: EXISTING REGLET DETAIL UNKNOWN. SEE DET. 7/A3 IF REGLET IS NOT
AutoCAD SHX Text
CONSTRUCTED AS SHOWN.
AutoCAD SHX Text
AutoCAD SHX Text
OSB BOARD
AutoCAD SHX Text
AS-BUILT DRAWINGS
AutoCAD SHX Text 9/22/94
AutoCAD SHX Text
USED CARLISLE U9D
AutoCAD SHX Text
TERMINATION DETAIL
AutoCAD SHX Text
USED CARLISLE U9D
AutoCAD SHX Text
TERMINATION DETAIL
AutoCAD SHX Text 6-1/2"
AutoCAD SHX Text
DRAINS
AutoCAD SHX Text
TECH SPECIALTIES UNIFLEX
AutoCAD SHX Text
ALL OTHER ROOFS USED
AutoCAD SHX Text
ROOF F: ROOF DRAIN ONLY
AutoCAD SHX Text
ROOF A: ROOF DRAIN
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .