Text version
SCOPE OF WORK
Joint Base Lewis - McCord (JBLM)
1. PROJECT DATA:
TITLE: Purchase and Install 1 ea. Vertical Carousel BUILDING/FACILITY: Joint Base Lewis McCord (JBLM) CONSTRUCTION DURATION: 90-120 days
2. GENERAL SCOPE:
The Contractor shall provide all supervision, labor, materials and equipment to purchase and install 1 each Vertical Carousels to support this requirement. The contractor shall install the Carousel system at Joint Base Lewis McCoord. The end user is responsible for providing electrical power to the unit. The contractor will provide final electrical hookup connections from the unit motor to the electrical disconnect.
3. DETAILED REQUIREMENTS (Vertical Carousels):
· Vertical Carousel must be of Ergonomic Design
· All Vertical Carousels must be “Clip System” panel concept for fast assemble/disassemble and for maintenance purposes allowing for high operator security in the event that stored goods fall inside the unit.
· All Vertical Carousels shall come with a lifetime warranty of the motor to assure years of reliable usage. All other components carry a 2-year warranty, including transportation, parts and labor.
· Vertical Carousels shall come equipped with an Emergency Power Crank for access to parts in case of power failure
· Vertical Carousels shall come equipped with a multifunctional profile allowing flexible fitment and positioning of operator panel, lighting and accessories above access opening.
· Vertical Carousels shall come equipped with a stainless-steel table surface at a standing position.
· Vertical Carousel shall have an imbalance indicator located on the operator station display that will alert the operator to any imbalance load.
· Vertical Carousels shall come equipped with a lockable lightweight one piece sliding door. Self-counterbalanced sliding door can be opened and closed with minimal effort. Two-piece sliding doors without counterbalance are not acceptable.
· Vertical Carousels must have 100% Reliable Safety Security System
· Vertical Carousels shall come equipped with finger protection safety buffer at rear of posting board.
· Vertical Carousels must come with transport rollers for fast and easy repositioning in the case of internal moves, providing maximum flexibility for unit positioning with minimum downtime and reinstallation costs.
· Vertical Carousels must have standard manual override systems allowing for the unit to be used until service technician’s repair.
· Vertical Carousels must have a standard manual override that can be operated with the door open, so parts can be located using “drive and view”, without having to know what carrier the part is stored on.
· The contactor must ensure the equipment complies with DIN EN 15095 “Power-operated mobile racking and shelving, carousels and storage lifts” and has been tested and certified by TÜV (Technical Observation & Control), a USA NRTL and a Canadian CB.
· The manufacture must be certified ISO 9001.
· The manufacture must be certified ISO 14001.
4. DETAILED VENDOR REQUIREMENTS:
· Contractor services shall be offered through an office that has a 24-hour turn-around time and must be assured and guaranteed on all requests for service. The installation and service must be performed by factory trained and authorized qualified individuals.
· Contractor must include Preventive Maintenance Services every 6 months for the duration of the 2-year warranty period in the price of the contract for the equipment.
5. OVERALL EQUIPMENT SPECIFICATION:
Vertical Carousel Shop Area (1 each):
· Overall Unit Height: 234.70”
· Minimum Room Height for Installation: 236.70”
· Overall Unit Width: 121.1”
· Overall Unit Depth: 78.40”
· Includes 12.6” - Work Counter
· Cubic Storage per Unit: 486.1 ft³
· Storage Area per Unit: 364.2 ft²
· Power Supply: 3/PE 230V (50/60 Hz)
· Rated Operating Current: 12 A
· Motor Power: 3 HP ; 2.2 KW
· Fuse Protection: 2 A t
· Control Generation C3000
· Power Consumption: 4. kVA
· Controller Location: End Frame, Right Side
· E‐Stop Location: (1) per Side Panel (2 Total)
· Controller: OPLogicontrol
· Table Height 39.37 in, Stainless Steel / Fixed Work Counter
· Access Opening Light
· Door Type: Automatic w/Electronic Lock
· Carriers per Unit: (22) Multipurpose Carriers
· Spacing (Pitch): 18”
· Carrier Clear Height: 16.02”/ Includes: 0.31 in. front lip
· Carrier Clear Width: 96.5”
· Carrier Clear Depth: 24.7 in.
· Carrier Capacity (max): 772 lbs.
END OF SCOPE OF WORK