Tab3-Crash Barrier Specs.pdf
PDF 41 KB Posted
- Attached to
- Mobile Crash Barrier - Brand Name Only
- Solicitation number
- FA462626Q0027
About this file
This document specifies the equipment requirements for a mobile crash barrier system to be procured for Malmstrom Air Force Base. The primary requirement is one MP5000 hydraulically operated mobile surface-mounted barrier system tested in accordance with ASTM F 2656-07 M40 standards. The basic system includes a 16-foot standard clear opening barrier structure, a battery-operated hydraulic pump with control station, a barrier trailer assembly with spare tire and utility box, a quick deployment mobile barrier assembly, a hinged rigid crash plate assembly, trailer hitch assembly, standard white/yellow or black/yellow paint options, and complete operational instructions and troubleshooting manual.
The document also identifies optional system components available for additional procurement, including a remote open/close push button station with 20-foot cable, barricade fully down auxiliary limit switch, 12VDC booster pack, external stop-go signal lights, 48-inch tall traffic light mounting post with 24-inch square base, cable kit with jumper cable and utility outlet connection, and a barrier turn table. The specifications establish the baseline configuration and enhancement options for the mobile crash barrier system required at the installation.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TESTED IN ACCORDANCE WITH ASTM F 2656-07 M40 STANDARDS
1 MP5000 BASIC STRUCTURE, -16 FT. (STANDARD) CLEAR OPENING
1 H4050
1 MP5000TA BARRIER TRAILER ASSEMBLY - INCLUDES SPARE TIRE,
UTILITY BOX, AND VIN NUMBER
BASIC SYSTEM CONSISTS OF:
* QUICK DEPLOYMENT MOBILE BARRIER ASSEMBLY
* HINGED, RIGID CRASH PLATE ASSEMBLY
* TRAILER HITCH ASSEMBLY
* STANDARD WHITE/YELLOW OR BLACK/YELLOW PAINT (OPTIONS AVAILABLE)
* COMPLETE INSTRUCTIONS, START UP AND TROUBLE-SHOOTING MANUAL
MP5000 SYSTEM OPTIONS: (NOT INCLUDED WITH BASIC SYSTEM)
1 MPL-4050 REMOTE OPEN/CLOSE PUSH BUTTON STATION W/20' CABLE
1 B2010 BARRICADE FULLY DOWN AUXILIARY LIMIT SWITCH
1 B1154 BOOSTER PAK 12VDC
1 MPL-10 STOP GO SIGNAL LIGHT(S) (EXTERNAL POWER REQUIRED)
1 MPL-20W 48" TALL TRAFFIC LIGHT MOUNTING POST WITH 24" SQ BASE
1 CAB KIT CABLE KIT (JUMPER CABLE, UTILITY OUTLET CONNECTION)
1 MP5K-TT1 BARRIER TURN TABLE
BATTERY OPERATED HYDRAULIC PUMP / W CONTROL STATION
MP5000 MOBILE CRASH BARRIER OR EQUIVILENT
MALSTROM AFB
MP5000 HYDRAULICALLY OPERATED MOBILE SURFACE MOUNTED BARRIER SYSTEM
File details come from the government source that posted it. Updated .