This document provides special packaging instructions for an alternator. It specifies how the part is to be cleaned, preserved, wrapped, cushioned, blocked, and packed within various containers for shipment. The alternator is to be preserved on unpainted metallic surfaces, wrapped securely with tape, and cushioned and blocked within containers according to detailed instructions. The unit container is to be marked per military standards and is designated as a reusable container. Packing is to be accomplished using either a cleated plywood box or the sealed and reinforced unit container, with palletization required for shipments over 125 pounds.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Tab 10 - CSS SP3300-23-Q-0174.pdf | ||
| Tab 29 - SPI AK13089191 DWG.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DD FORM 2169, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page1 of 4 Pages
SPECIAL PACKAGING INSTRUCTION Form Approved OMB No. 0704-0188
-EW
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12358709-1 (19207) ALTERNATOR, 200 AMP 19207 AK12922993
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2920-01-292-2993 08-18-2015
7. QUP 8. ICQ 9. UNIT PACK WT. (LB) 10. UNIT PACK CU (CU FT) 11. UNIT PACK SIZE (INCHES)
1 EA NONE 82.7 2.026 17.0 X 14.8 X 13.9
12. MILITARY PRESERVATION (METHOD) 18.
STEPS
19.
REQ’D
20.
DESCRIPTION
MIL-STD-2073-1D, METHOD 42 1B PRESERVATIVE: MIL-PRF-21260
13. CLEANING 2C 1 WRAP: MIL-B-121, TYPE II, GRADE A, 46 X 26
MIL-STD-2073-1D, PROCESS 1 3D CUSHIONING: SEE NOTES
14. DRYING 4 1 CONTAINER: ASTM-D5118, STYLE RSC, TYPE CF,
MIL-STD-2073-1D CLASS DOM, VERITY SW, 13-5/8 X 12-3/4 X 14-3/4
5 CLOSEURE: ASTM D1974, METHOD 2B3 OR 2B4
15. PACKING
a. LEVEL A 6E BARRIER: MIL-DTL-117, STYLE 1, TYPE I, CLASS E
MIL-STD-2073-1D AND NOTE G SIZE 29 X 34
b. LEVEL B 7 CONTAINER: ASTM-D5118, STYLE RSC, TYPE CF, MIL-STD-2073-1D AND NOTE G CLASS WR, VERITY DW, GRADE V13C
16. MARKING SIZE 13-5/8 X 12-3/4 X 14-3/4
MIL-STD-129 AND NOT F 8 CLOSEURE: ASTM D1974, METHOD 2B3 OR 2B4
17. NOTES / DRAWING
A. INSPECT THE PRESERVATION, THE UNIT PACK AND THE PACKING IN ACCORDANCE WITH
MIL-STD-2073-1D AND THE APPLICABLE CONTAINER SPECIFICATION.
B. APPLY PRESERVATIVE TO UNPAINTED AND UNPRESERVED EXTERIOR METALLIC SURFACES.
C. WRAP ALTERNATOR AND SECURE WRAP WITH TAPE
D. FOR DETAILS OF CUSHIONING, BLOCKING, AND PLACEMENT OF ITEM WITHIN CONTAINER; SEE SHEETS 2
THROUGH 4.
E. CLOSE BAG BY HEAT SEALING
F. THE UNIT CONTAINER SHALL BE MARKED ON TOP AND ONE SID IAW MIL-STD-129 SPECIAL MARKINGS, "REUSABLE CONTAINER AND CUSHIONING, DO NOT DESTROY. OPEN ALONG TOP SEAMS USING A
SHALLOW BLADE KNIFE.
G. LEVEL A: PACKING SHALL BE ACCOMPLISHED USING A CLEATED PLYWOOD BOX, CONFORMING TO
ASTM-D6251, TYPE III, CLASS 1.
LEVEL B: THE UNIT CONTAINER IS AN ACCEPTABLE LEVEL B SHIPPING CONTAINER WHEN SEALED AND
REINFORCED IN ACCORDANCE WITH ASTM-D1974, METHOD 2C OR 2D.
FOR BOTH LEVEL A AND LEVEL B, WHEN THE TOTAL QUANTITY TO BE SHIPPED TO THE SAME
DESTINATION EXCEEDS 125 POUNDS, EXTERIOR PACKS WITHOUT SKIDS SHALL BE PALLETIZED.
MIL-HDBK-774 MAY BE USED FOR GUIDANCE.
2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page2of 4 Pages
OMB No. 0704-0188
-EW
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12358709-1 (19207) ALTERNATOR, 200 AMP 19207
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
08-18-20152920-01-292-2993
AK12922993
2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page3of 4 Pages
OMB No. 0704-0188
-EW
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12358709-1 (19207) ALTERNATOR, 200 AMP 19207
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
2169C, JUN 1997 (EG) WCT 9-99 PREVIOUS EDITIONS ARE OBSOLETE Page4of 4 Pages
OMB No. 0704-0188
-EW
The public reporting burden for this collection of information is estimated to average 30 days per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THIS ADDRESS
1. PART OR DRAWING NO. (CAGE) NOMENCLATURE 2. CODE IDENT 3. SPI NO.
12358709-1 (19207) ALTERNATOR, 200 AMP 19207
4. NATIONAL STOCK NUMBER 5. DATE OF DRAWING 6. REVISION
File details come from the government source that posted it. Updated .