T1.1 Structured Cabling System.pdf
PDF 360 KB Posted
- Solicitation number
- RFP - PENN - 240000000864
- Issued by
- Calhoun County, Battle Creek City, Michigan
About this file
This document appears to be a structured cabling plan for the Pennfield Schools North Penn Elementary Classroom Addition project in Battle Creek, Michigan. The project involves the installation of a structured cabling system, including single-mode fiber optic cabling, Category 6 and 6A data outlets, and wireless access point and security camera connections. Key details include the maximum fiber optic cable length of 300 feet, the requirement for the electrical contractor to provide conduits and sleeves, and the structured cabling contractor's responsibility for firestopping. The project is located in Calhoun County and the City of Battle Creek.
The document does not provide specific pricing terms, set-asides, incumbent information, funding requirements, or other salient commercial details. It appears to be a technical specification focused on the cabling infrastructure requirements for the project.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| TP1.1 Public Address System.pdf | ||
| 23-PS-SNP-01 Bid Forms.docx | DOCX document | |
| 23-PS-SNP-01 RFB.pdf | ||
| 23-PS SNP-01 Advertisement for Bid.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURED CABLING PLAN KEYNOTES
CONDUIT TO BACK BOX AT THIS LOCATION IS ROUTED UNDER FLOOR FROM I.T. ROOM C1141
VERIFY EXACT LOCATION OF EQUIPMENT RACK WITH TECHNOLOGY DESIGNER AND OWNER PRIOR
TO INSTALLATION.
THE TOTAL FIBER OPTIC CABLE LENGTH SHALL NOT EXCEED 300 FEET INCLUDING MAINTENANCE LOOPS.3
1. INDICATES CONSTRUCTION DOCUMENT ROOM NUMBERS.
2. ALL CONDUITS, SLEEVES, AND CORES ARE PROVIDED BY THE ELECTRICAL CONTRACTOR. REFER TO
ELECTRICAL PLANS FOR CONDUIT ROUTING AND SLEEVE LOCATIONS.
3. STRUCTURED CABLING CONTRACTOR SHALL FIRESTOP ALL CONDUITS, SLEEVES, AND CORES PROVIDED
FOR STRUCTURED CABLING.
XX
STRUCTURED CABLING GENERAL NOTES
CLASSROOM
C112
CORRIDOR
C101
MUSIC
C102
I.T.
C114
T.
C105
CLASSROOM
C104
CLASSROOM
C110
T.
C111
T.
C113
T.
C103
T.
C109
T.
C107
CLASSROOM
C108
CLASSROOM
C106
+90"
AFF
+90"
AFF
WAP WAP
WAPWAP
WAP WAP
TS
PR
TS
TS
TS
PR
+90"
AFF
TS
PR
+90"
AFFPR
TS
TS TS
+90"
AFFPR
+90"
AFFPR
TS TS
TS TS
CAM
CAM
CAM
CAM
CAMCAM
ER
SINGLE-MODE
FIBER TO MDF
FO
C
FO
C
FO
C
STRUCTURED CABLING SYMBOL LEGEND
WALL MOUNTED DOUBLE DATA OUTLET - TWO (2) CATEGORY 6 UTP
CEILING MOUNTED SINGLE DATA FOR WIRELESS ACCESS POINT - ONE (1) CATEGORY 6A UTP
WAP
CAM
CEILING MOUNTED SINGLE DATA FOR SECURITY CAMERA - ONE (1) CATEGORY 6 UTP
ER EQUIPMENT RACK
TEACHER STATION - SEE DETAIL 2 THIS SHEETTS
PROJECTOR LOCATION - SEE DETAIL 3 THIS SHEETPR
FIBER OPTIC CABLEFOC
2-GANG, 3 1/2" DEEP
BOX BY E.C.
CEILING LINE
1 1/4" CONDUIT
BUSHED ABOVE
ACCESSIBLE
CEILING BY E.C.
FOR AV CABLE
DECORA FRAME WITH
(2) CATEGORY 6 JACKS
DECORA
OPENING FOR
USE BY AV
CONTRACTOR
2-GANG DECORA
FACEPLATE
1 1/4" CONDUIT
BUSHED ABOVE
ACCESSIBLE CEILING
BY E.C.
FOR DATA CABLE
" A
FF
U
O N
2-GANG, 3 1/2" DEEP
BOX BY E.C.
BACK BOX FOR
USE BY AV
CONTRACTOR
" A
FF
U
O N
2-GANG, 3 1/2" DEEP
BOX BY E.C.
CEILING LINE
1 1/4" CONDUIT
BUSHED ABOVE
ACCESSIBLE
CEILING BY E.C.
FOR AV CABLE
DECORA FRAME WITH
(2) CATEGORY 6 JACKS
DECORA
OPENING FOR
USE BY AV
CONTRACTOR
2-GANG DECORA
FACEPLATE
1 1/4" CONDUIT
BUSHED ABOVE
ACCESSIBLE
CEILING BY E.C.
FOR DATA CABLE
2-GANG, 3 1/2" DEEP
BOX BY E.C.
DECORA FRAME WITH
(2) CATEGORY 6 JACKS
DECORA
OPENING FOR
USE BY AV
CONTRACTOR
2-GANG DECORA
FACEPLATE
" A
FF
U
O N
" A
FF
U
O N
Z:\Projects\PennfieldSchools3033\04b_North Elem 6 CR Additions\DRAWINGS\3Arch\EXPORTS\2023_11_28_CAD Export for IT\PS_NORTHPEN_ADDITION_r2023_vmurad5CHPP-logo-5668489.jpg
Z:\Projects\PennfieldSchools3033\04b_North Elem 6 CR Additions\DRAWINGS\3Arch\EXPORTS\2023_11_28_CAD Export for IT\PS_NORTHPEN_ADDITION_r2023_vmurad5CHPP-2015_Kingscott_orange-5668487.tif
KINGSCOTT ASSOCIATES INC. KALAMAZOO, MICHIGAN
JOB NO.
SHEET NO.
ISSUANCES DATE
259 East Michigan Ave., Suite 308 Kalamazoo, MI 49007-6403
P: 269.381.4880 | F:269.382.9110 800.632.7815
KALAMAZOO | GRAND RAPIDS | CHELSEA | ROYAL OAK
N3033.04
STRUCTURED CABLING FIRST
FLOOR PLAN - UNIT C
T1.1
P oo rm an
R oa d Ba ttle C re ek
, M I
Pe nn fie ld
S ch oo ls
N or th P en n
El em en ta ry C la ss ro om
A dd iti on
1/8" = 1'-0"1 FIRST FLOOR PLAN - UNIT C
BID & CONSTRUCTION 01/08/2024
818 West 11 Mile Road Royal Oak, Michigan 48067
TECHNOLOGY ADVISORS
Innovative & Independent
TEL: 248.594.5850
wrighthunter.com
NTS2 TEACHER STATION (TS) DETAIL
NTS3 PROJECTOR LOCATION (PR) DETAIL
AutoCAD SHX Text C6
AutoCAD SHX Text C6
AutoCAD SHX Text C6
AutoCAD SHX Text C6
AutoCAD SHX Text C6
AutoCAD SHX Text C6
AutoCAD SHX Text C
AutoCAD SHX Text C
| Sheets and Views |
| 30x42 |
File details come from the government source that posted it. Updated .