SWVCC 260-18721-002 Project Drawings 2026-03-20.pdf
PDF 6 MB Posted
- Attached to
- Russell Hall and Tazewell Hall Lab Renovations at Southwest Virginia Community College PC#260-18721. 002
- Solicitation number
- DBB-117307
- Issued by
- Brunswick County, Chatham Town, Virginia
About this file
This project drawing document pertains to renovation work at Southwest Virginia Community College (SWVCC) in Cedar Bluff, Virginia, involving two campus buildings under project code 260-18721-002. The project encompasses the renovation of an existing Anatomy Lab in Tazewell Hall to enhance functionality and the conversion of an existing classroom in Russell Hall into an immersive learning environment for interactive healthcare education. The renovations are Level 2 alterations under the 2021 Virginia Existing Building Code and must comply with the 2021 Virginia Construction Code, 2021 International Fire Code, 2021 International Building Code, 2020 NFPA 70 National Electrical Code, the 2025 Commonwealth of Virginia Construction and Professional Service Manual, ADA Title II standards, and the Virginia Energy Conservation Code. The project includes architectural, mechanical, electrical, and plumbing work across both buildings' second floors, with detailed specifications for HVAC systems, lighting controls with occupancy sensors, emergency safety equipment, and interior finishes including new flooring, ceiling treatments, and casework modifications.
Tazewell Hall requires asbestos abatement by a licensed contractor under a separate contract prior to the general contractor's notice to proceed, with no asbestos-containing materials found during inspection of that building; Russell Hall had asbestos-containing materials identified that must be abated before work commences. Lead-containing components were identified in both buildings, and the contractor is responsible for compliance with Virginia Occupational Safety and Health regulations and recycling of lead materials. The project design includes new electrical circuits, pop-up tower receptacles, updated HVAC equipment including an energy recovery unit with demand control ventilation based on CO2 sensors, ductless mini-split systems, emergency eye wash and shower stations, and new lighting with occupancy sensors and dimming controls. Existing electrical panels at both locations have available capacity to accommodate the added loads from the renovations. The project was issued for bids on March 20, 2026, with project management oversight by SWVCC's VCCS Project Manager Mike Wagner, and drawings prepared by T-L architecture firm located in Radford, Virginia.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SWVCC 260-18721-002 Notice of Invitation for Bids.pdf | ||
| SWVCC 260-18721-002 Project Manual 2026-03-20.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT DESCRIPTION:
THIS PROJECT INVOLVES THE RENOVATION OF AN EXISTING ANATOMY LAB IN
TAZEWELL HALL TO ENHANCE ITS FUNCTIONALITY. ADDITIONALLY, THIS PROJECT
INCLUDES THE CONVERSION OF AN EXISTING CLASSROOM IN RUSSELL HALL INTO AN
IMMERSIVE LEARNING ENVIRONMENT FOR AN INTERACTIVE EXPERIENCE WITH
STUDENTS.
CODES & REGULATIONS
2021 VIRGINIA EXISTING BUILDING CODE, (VEBC) - THIS IS A LEVEL 2 ALTERATION
2021 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM STATEWIDE
BUILDING CODE (VUSBC)
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
2021 INTERNATIONAL FIRE CODE
CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION.
2021 INTERNATIONAL BUILDING CODE
2021 VIRGINIA MECHANICAL CODE
2021 VIRGINIA PLUMBING CODE
2020 NFPA 70 NATIONAL ELECTRICAL CODE
2025 COMMONWEALTH OF VIRGINIA CONSTRUCTION AND PROFESSIONAL SERVICE MANUAL (CPSM), REVISION 0, MARCH 17, 2025
ADA90-TITLE II (ASAD Chapter 2 for Scoping, A117.1-2017 Chapters 1 and 3 through 11 for Technical
Requirements)
HIGH PERFORMANCE BUILDINGS ACT
IN ACCORD WITH THE HIGH PERFORMANCE BUILDINGS ACT, THE BUILDING IS EXEMPT FROM
COMPLIANCE BECAUSE THE COST OF THE RENOVATIONS DOES NOT EXCEED 50% OF THE VALUE OF THE
BUILDING.
ASBESTOS DISCLOSURE STATEMENT
TAZEWELL HALL
AN ASBESTOS INSPECTION WAS PERFORMED AND NO ACM WAS FOUND. THE ASBESTOS INSPECTION
REPORT IS INCLUDED AS AN APPENDIX TO THE PROJECT SPECIFICATIONS.
LEAD DISCLOSURE STATEMENT
TAZEWELL HALL
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS BEEN
CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS REPORT IS PROVIDED FOR THE
CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY
PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS
SHALL BE RECYCLED TO THE EXTENT POSSIBLE.
ASBESTOS DISCLOSURE STATEMENT
RUSSELL HALL
AN ASBESTOS INSPECTION WAS PERFORMED AND ACM WAS FOUND GENERALLY IN THE AREA
INDICATED. THE ASBESTOS INSPECTION REPORT IS INCLUDED AS AN APPENDIX TO THE PROJECT
SPECIFICATIONS. THE OWNER SHALL SUBMIT AN APPLICATION FOR PERMIT TO HAVE THE ASBESTOS-
CONTAINING MATERIALS ABATED BY A LICENSED ASBESTOS CONTRACTOR UNDER A SEPARATE
CONTRACT USING APPROVED PROCEDURES PRIOR TO ISSUING A NOTICE TO PROCEED TO THE GENERAL
CONTRACTOR. ANY ACM THAT IS TO REMAIN AND THE NEW NON ASBESTOS-CONTAINING MATERIAL
SHALL BE LABELED ACCORDINGLY. THE ASBESTOS ABATEMENT CONTRACTOR SHALL MARK UP THE AS-
BUILT DRAWINGS RESULTING FROM ITS WORK TO INCLUDE AREAS WHERE ASBESTOS WAS ABATED, AREAS WHERE ASBESTOS WAS ENCAPSULATED, AND AREAS WHERE ACM EXIST BUT WERE LEFT IN
PLACE. THE GENERAL CONTRACTOR SHALL REVIEW AND CERTIFY THE LOCATIONS WHERE ACM WAS
ABATED, AREAS WHERE ACM WAS ENCAPSULATED AND AREAS WHERE ACM WAS LEFT IN PLACE AS
MARKED ON THE AS-BUILT DRAWINGS AND WILL PROVIDE THE DRAWINGS TO THE ARCHITECT.
LEAD DISCLOSURE STATEMENT
RUSSELL HALL
AN INSPECTION TO IDENTIFY LEAD CONTAINING OR COATED BUILDING COMPONENTS HAS BEEN
CONDUCTED AND CAN BE FOUND IN THE PROJECT SPECIFICATIONS. THIS REPORT IS PROVIDED FOR THE
CONTRACTOR’S USE AND MAY NOT BE ALL INCLUSIVE. IT IS THE CONTRACTOR’S RESPONSIBILITY TO
COMPLY WITH ALL VIRGINIA OCCUPATIONAL SAFETY AND HEALTH (VOSH) REGULATIONS AS THEY
PERTAIN TO EMPLOYEE EXPOSURES TO LEAD. ALL LEAD AND LEAD-COATED BUILDING COMPONENTS
SHALL BE RECYCLED TO THE EXTENT POSSIBLE.
POINT OF CONTACT
SOUTHWEST VIRGINIA COMMUNITY COLLEGE
VCCS PROJECT MANAGER: MIKE WAGNER
P: 804-258-8802
635 COMMUNITY COLLEGE RD
CEDAR BLUFF, VA 24609
VIRGINIA ENERGY CONSERVATION CODE
COMPLIANCE STATEMENT
IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE BUILDING SHALL COMPLY
WITH VECC SECTIONS C402 THROUGH C405 AND C408.
PREPARED FOR
NORTH CAROLINA
VIRGINIA
WEST
VIRGINIA
WASHINGTON D.C.
RICHMOND
RALEIGH
ROANOKE
ABINGDONBRISTOL
BIG STONE GAP
NORTON RICHLANDS
GRUNDY
PRINCETON
N
FARMVILLE
TAZEWELL
PROJECT LOCATION
PROJECT LOCATIONS
FOR ELECTRICAL ONLYFOR ARCHITECTURAL &
LIFE SAFETY ONLY
FOR PLUMBING,
FIRE PROTECTION AND MECHANICAL ONLY
Sheet No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
F il e
N a m e
VICINITY MAP
726 Auburn Avenue
Radford, Virginia 24141
P: (540) 633-1897, F: (540) 633-1896 www.T-L.com
EST. 1956
LOCATION MAP
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:2
:4
A
M C
U se rs
\T Y
LE
R
M
C D
A N
IE
L\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a lls v tm cd a n ie lZ
LN
U
.r v t
G001
18630
PROJECT NO.: 18630
03/20/2026
ISSUED FOR BIDS
TI
TL
E
SH
EE
T
03/20/2026
TWM
TWM
EFS
SOUTHWEST VIRGINIA COMMUNITY COLLEGE
TAZEWELL HALL ANATOMY LAB AND RUSSELL HALL IMMERSIVE HEALTHCARELAB RENOVATIONS
PROJECT CODE:260-18721-002
CEDAR BLUFF, VIRGINIA
VIRGINIA COMMUNITY COLLEGE SYSTEM
SHEET INDEX
SHEET NAME SHEET NUMBER
GENERAL
TITLE SHEET G001
PROJECT INFOMATION AND DATA G002
UL DETAIL G003
ARCHITECTURAL
RUSSELL HALL SECOND FLOOR PLAN A101
TAZEWELL HALL SECOND FLOOR PLAN A102
TAZEWELL HALL SECOND FLOOR RCP AND CASEWORK DETAILS A103
FINISH SCHEDULE AND NOTES A701
MECHANICAL
HVAC LEGENDS, NOTES & SCHEDULES M001
HVAC DETAILS M002
RUSSELL HALL SECOND FLOOR HVAC PLAN M101
TAZEWELL HALL SECOND FLOOR HVAC PLAN M102
ELECTRICAL
GENERAL NOTES, LEGEND, ABBREVIATIONS, AND DETAILS E001
RUSSELL HALL SECOND FLOOR ELECTRICAL PLAN E101
TAZEWELL HALL SECOND FLOOR ELECTRICAL PLANS E201
TAZEWELL HALL SECOND FLOOR ELECTRICAL PLANS E202
RUSSELL HALL PHOTOMETRICS E401
TAZEWELL HALL PHOTOMETRICS E402
ONE-LINE DIAGRAM AND SCHEDULE E601
N o
D a te
P u rp o se o f D o cu m e n t
Is su e
BUCHANAN HALL
TAZEWELL HALL
RUSSELL HALL
DICKENSON HALL
WORKFORCE BUILDING
PHYSICAL PLANT
RECREATION/ATHLETICS
RALPH B. DAVIS HALL
CHARLES R. KING COMMUNITY CENTER
EARL E. & DORTHY DELLINGER HALL
PARKING
ACCESSIBLE PARKING
SIDEWALKS
U.S. ROUTE 19
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
O
N
DN
DN
W
S
WW
V
CODES & REGULATIONS
2021 VIRGINIA EXISTING BUILDING CODE, (VEBC) - THIS IS A LEVEL 2 ALTERATION
2021 VIRGINIA CONSTRUCTION CODE (VCC), PART 1 OF THE VIRGINIA UNIFORM STATEWIDE
BUILDING CODE (VUSBC)
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
2021 INTERNATIONAL FIRE CODE
CHAPTER 33 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION.
2021 INTERNATIONAL BUILDING CODE
2021 VIRGINIA MECHANICAL CODE
2021 VIRGINIA PLUMBING CODE
2020 NFPA 70 NATIONAL ELECTRICAL CODE
2025 COMMONWEALTH OF VIRGINIA CONSTRUCTION AND PROFESSIONAL SERVICE MANUAL (CPSM), REVISION 0, MARCH 17, 2025
ADA90-TITLE II (ASAD Chapter 2 for Scoping, A117.1-2017 Chapters 1 and 3 through 11 for Technical
Requirements)
GENERAL INFORMATION - TAZEWELL
THIS PROJECT INVOLVES THE RENOVATION OF AN EXISTING ANATOMY LAB IN
TAZEWELL HALL TO ENHANCE ITS FUNCTIONALITY.
SCOPE:
CONSTRUCTION CLASSIFICATION:
CONSTRUCTION TYPE: IIB
NEW BUILDING IS NOT FULLY SPRINKLERED PER NFPA 13
OCCUPANCY:
DESCRIPTION:
OCCUPANCY CLASSIFICATION: BUSINESS (B)
MAXIMUM TRAVEL DISTANCES:
COMMON PATH OF TRAVEL (VUSBC 1006.2.1):
EXIT ACCESS TRAVEL DISTANCE (VUSBC
TABLE 1017.2):
DEAD ENDS (VUSBC 1020.4):
100 FT MAX
200 FT MAX
50 FT MAX
INTERIOR FINISH REQUIREMENTS:
CORRIDOR WALLS & CEILINGS (VUSBC TABLE 803.11):
-CLASS C
FLOORS (VUSBC 804.4.2):
-CLASS II
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
ROOM & ENCLOSED SPACE WALLS & CEILINGS (VUSBC
TABLE 803.9):
-CLASS C
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
CRITICAL RADIANT FLUX NOT LESS THAN 0.22 WATTS/CM
ASBESTOS CONTAINING MATERIALS AND/OR PAINTS CONTAINING LEAD SHALL
NOT BE USED IN ANY FORM ON THE PROJECT.
EXIT ENCLOSURES & EXIT PASSAGEWAYS (VUSBC TABLE 803.11):
-CLASS B
FLAME SPREAD INDEX 26-75
SMOKE-DEVELOPED INDEX 0-450
OCCUPANCY LOAD SUMMARY - TAZEWELL
NO OCCUPANCY LOAD CHANGE
BUILDING AREA SUMMARY - TAZEWELL
CODE BUILDING AREA (VUSBC 502.1):
GROSS BUILDING AREA:
RENOVATED AREA:
13,971 SF
14,295 SF
1,260 SF
FIRE-RESISTANCE RATING
REQUIREMENTS - TAZEWELL
BUILDING ELEMENT
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS (HOURS)
FIRE RATING
(EXCERPT FROM VUSBC TABLE 601, UON)
BEARING WALLS
EXTERIOR
INTERIOR
0 HR
0 HR
CONSTRUCTION TYPE: <INSERT TYPE>
PRIMARY STRUCTURAL FRAME 0 HR
NONBEARING WALLS & PARTITIONS
EXTERIOR (VUSBC TABLE 602) 0 HR
NONBEARING WALLS & PARTITIONS
INTERIOR 0 HR
FLOOR CONSTRUCTION & SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION & SECONDARY MEMBERS 0 HR
BUILDING ELEMENT FIRE RATING
MISCELLANEOUS FIRE-RESISTANCE RATING REQUIREMENTS
CORRIDORS (VUSBC TABLE 1020.1) 1 HR
DRAFTSTOPPING REQUIREMENTS PER VUSBC 718.4.3
ATTICS OR CONCEALED ROOF SPACES 3000 SF MAX AREA
GENERAL INFORMATION - RUSSELL
THIS PROJECT INCLUDES THE CONVERSION OF AN EXISTING CLASSROOM INTO AN
IMMERSIVE LEARNING ENVIRONMENT FOR AN INTERACTIVE EXPERIENCE WITH
STUDENTS.
SCOPE:
CONSTRUCTION CLASSIFICATION:
CONSTRUCTION TYPE: IIB
NEW BUILDING IS NOT FULLY SPRINKLERED PER NFPA 13
OCCUPANCY:
DESCRIPTION: <INSERT; E.G. MIXED-USE, NON-SEPARATED>
OCCUPANCY CLASSIFICATION: BUSINESS (B)
MAXIMUM TRAVEL DISTANCES:
COMMON PATH OF TRAVEL (VUSBC 1006.2.1):
EXIT ACCESS TRAVEL DISTANCE (VUSBC
TABLE 1017.2):
DEAD ENDS (VUSBC 1020.4):
100 FT MAX
200 FT MAX
50 FT MAX
INTERIOR FINISH REQUIREMENTS:
CORRIDOR WALLS & CEILINGS (VUSBC TABLE 803.11):
-CLASS C
FLOORS (VUSBC 804.4.2):
-CLASS II
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
ROOM & ENCLOSED SPACE WALLS & CEILINGS (VUSBC
TABLE 803.9):
-CLASS C
FLAME SPREAD INDEX 76-200
SMOKE-DEVELOPED INDEX 0-450
CRITICAL RADIANT FLUX NOT LESS THAN 0.22 WATTS/CM
ASBESTOS CONTAINING MATERIALS AND/OR PAINTS CONTAINING LEAD SHALL
NOT BE USED IN ANY FORM ON THE PROJECT.
EXIT ENCLOSURES & EXIT PASSAGEWAYS (VUSBC TABLE 803.11):
-CLASS B
FLAME SPREAD INDEX 26-75
SMOKE-DEVELOPED INDEX 0-450
BUILDING AREA SUMMARY - RUSSELL
CODE BUILDING AREA (VUSBC 502.1):
GROSS BUILDING AREA:
RENOVATED AREA:
41, 714 SF
43,818 SF
1,260 SF
OCCUPANCY LOAD SUMMARY - RUSSELL
NO OCCUPANCY LOAD CHANGE
FIRE-RESISTANCE RATING
REQUIREMENTS - RUSSELL
BUILDING ELEMENT
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS (HOURS)
FIRE RATING
(EXCERPT FROM VUSBC TABLE 601, UON)
BEARING WALLS
EXTERIOR
INTERIOR
0 HR
0 HR
CONSTRUCTION TYPE: <INSERT TYPE>
PRIMARY STRUCTURAL FRAME 0 HR
NONBEARING WALLS & PARTITIONS
EXTERIOR (VUSBC TABLE 602) 0 HR
NONBEARING WALLS & PARTITIONS
INTERIOR 0 HR
FLOOR CONSTRUCTION & SECONDARY MEMBERS 0 HR
ROOF CONSTRUCTION & SECONDARY MEMBERS 0 HR
BUILDING ELEMENT FIRE RATING
MISCELLANEOUS FIRE-RESISTANCE RATING REQUIREMENTS
CORRIDORS (VUSBC TABLE 1020.1) 1 HR
DRAFTSTOPPING REQUIREMENTS PER VUSBC 718.4.3
ATTICS OR CONCEALED ROOF SPACES 3000 SF MAX AREA
REF
TRAVEL DISTANCE: 189'-6"
45 MIN.
RATED DOOR
TRAVEL DISTANCE: 180'-6"
EXISTING 1-HOUR PARTITION
LIFE SAFETY LEGEND
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:2
:4
A
M C
U se rs
\T Y
LE
R
M
C D
A N
IE
L\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a lls v tm cd a n ie lZ
LN
U
.r v t
G002
P R
O
JE
C T
IN
FO
M A
TI
O
N A
N D
D A
TA
18630
PROJECT CODE: 260-18721-002
TWM
TWM
EFS
03/20/2026
SCALE: 1/16" = 1'-0"G002
1 TAZEWELL HALL - SECOND FLOOR LIFE SAFETY
SCALE: 1/16" = 1'-0"G002
2 RUSSELL HALL - SECOND FLOOR LIFE SAFETY
601.2.2 LEVEL 2
LEVEL 2 ALTERATIONS SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTIONS 602 AND 603
AND SHALL INCLUDE THE FOLLOWING:
1. THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW.
2. THE ADDITION OR ELIMINATION OF ANY WALL, FLOOR, OR CEILING ASSEMBLY.
3. THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM.
4. THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT, MATERIALS, ELEMENTS, OR FIXTURES.
602.1 SCOPE.
LEVEL 1 ALTERATIONS AS DESCRIBED IN SECTION 601.2.1 SHALL COMPLY WITH THE REQUIREMENTS OF
THIS SECTION.
602.2 CONFORMANCE.
ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE FOLLOWING:
1. LEVEL OF FIRE PROTECTION THAT IS EXISTING.
2. LEVEL OF PROTECTION THAT IS EXISTING FOR THE MEANS OF EGRESS.
602.3.1 INTERIOR FINISHES AND TRIM.
ALL NEWLY INSTALLED INTERIOR FINISH AND TRIM MATERIALS AND WALL, FLOOR, AND CEILING FINISHES
SHALL COMPLY WITH CHAPTER 8 OF THE VCC.
602.3.2 MATERIALS AND METHODS.
ALL NEW BUILDING ELEMENTS AND MATERIALS SHALL COMPLY WITH THE MATERIALS AND METHODS
REQUIREMENTS IN THE VCC, INTERNATIONAL ENERGY CONSERVATION CODE, INTERNATIONAL
MECHANICAL CODE, AND INTERNATIONAL PLUMBING CODE, AS APPLICABLE, THAT SPECIFY MATERIAL
STANDARDS, DETAIL OF INSTALLATION AND CONNECTION, JOINTS, PENETRATIONS, AND CONTINUITY OF
ANY ELEMENT, COMPONENT, OR SYSTEM IN THE BUILDING.
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
TEMP. 1-HR
PARTITION
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:2
:4
A
M C
U se rs
\T Y
LE
R
M
C D
A N
IE
L\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a lls v tm cd a n ie lZ
LN
U
.r v t
G003
U L
D
ET
A
IL
18630
PROJECT CODE: 260-18721-002
TWM
TWM
EFS
03/20/2026
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
SO
U
TH
W
ES
T V
IR
G
IN
IA
C O
M M
U N
IT
Y
C O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
VV
F
F F
F
F
G
GG
1 1
SIM LAB
R235
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
R235
SIM LAB
R235
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
GENERAL CONSTRUCTION NOTES - RUSSELL HALL:
1. ALL WORK SHALL BE PERFORMED OUTSIDE OF BUILDING'S OCCUPIED HOURS.
2. ALL WORK SHALL BE PERFORMED IN OBSERVANCE OF STATE, AND FEDERAL CODES AND
REGULATIONS.
3. EXISTING CONDITIONS SHOWN HEREIN WERE TAKEN FROM SITE OBSERVATIONS AND COMPLETE
OR PARTIAL SETS OF ORIGINAL DESIGN DRAWINGS WHEN MADE AVAILABLE. ANY
DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL BUILT CONDITIONS ARE TO BE
REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
4. LOOSE FURNISHINGS, APPLIANCES, AND EQUIPMENT ARE NOT INCLUDED WITHIN THIS
PROJECT'S SCOPE (NIC), UNLESS OTHERWISE NOTED.
5. DO NOT "SCALE" DRAWINGS. USE DIMENSIONAL INFORMATION PROVIDED ONLY. FOR
DIMENSIONS NOT SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST CLARIFICATION
FROM ARCHITECT PRIOR TO PROCEEDING.
6. ALL DIMENSIONS ARE MEASURED TO FACE OF METAL AND/OR WOOD STUDS OR MASONRY
CONSTRUCTION UNLESS OTHERWISE NOTED.
7. ALL DIMENSIONS NOTED AS "CLEAR," ARE FROM FACE OF FINISH TO FACE OF FINISH.
SCALE: 1/4" = 1'-0"A101
3 RUSSELL HALL - REFLECTED CEILING PLAN
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:2
:4
A
M C
U se rs
\T Y
LE
R
M
C D
A N
IE
L\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a lls v tm cd a n ie lZ
LN
U
.r v t
A101
R U
SS
EL
L H
A
LL
S
EC
O N
D F
LO
O
R P
LA
N
18630
PROJECT CODE: 260-18721-002
TWM
TWM
EFS
03/20/2026
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN - RUSSELL HALL SECOND FLOOR
WORK
AREA
SCALE: 1/4" = 1'-0"A101
2 RUSSELL HALL - NEW WORK PLAN
RUSSELL HALL CONSTRUCTION NOTES
1 INSTALL BLACKOUT FILM ON EXISTING WINDOWS.
2 ALL NEW DRYWALL TO BE LEVEL 5 FINISH
3 NEW LVT FLOORING
4 PAINT INTERIOR OF DOOR AND TRIM TO MATCH WALLS IN ROOM
SCALE: 1/4" = 1'-0"A101
1 RUSSELL HALL - DEMO PLAN
RUSSELL HALL DEMOLITION NOTES
1 REMOVE PROJECTOR SCREEN. TURN OVER TO OWNER
2 REMOVE EXISTING BLACKBOARD. TURN OVER TO OWNER
3 REMOVE RUBBER BASE IN ITS ENTIRETY
4 REMOVE EXISTING CEILING AND GRID
1 NEW CEILING - ACT-1
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
SO
U
TH
W
ES
T V
IR
G
IN
IA
C O
M M
U N
IT
Y
C O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
W
S
DN
W
S
1 1 1
A103
A102
8'-6"
9"
A103
A102
ALIGN W/
COLUMN
A102 A103
CLASSROOM
R218
A102 A103
6"
A103
A102
A102 A103
R
EA
C H
D
IS
T.
1'-9 " R
EA
C
H D
IST.
8"
M
IN
REF
REF
5 5
4 4
4 4
A103
A102
CLASSROOM
R218
A103
A102
R218
?OCCURS WHERE ARE INDICATED ON DRAWINGS.
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
GENERAL CONSTRUCTION NOTES - TAZEWELL:
1. ALL WORK SHALL BE PERFORMED IN OBSERVANCE OF STATE, AND FEDERAL CODES AND
REGULATIONS.
2. EXISTING CONDITIONS SHOWN HEREIN WERE TAKEN FROM SITE OBSERVATIONS AND COMPLETE
OR PARTIAL SETS OF ORIGINAL DESIGN DRAWINGS WHEN MADE AVAILABLE. ANY
DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL BUILT CONDITIONS ARE TO BE
REPORTED TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
3. LOOSE FURNISHINGS, APPLIANCES, AND EQUIPMENT ARE NOT INCLUDED WITHIN THIS
PROJECT'S SCOPE (NIC), UNLESS OTHERWISE NOTED.
4. DO NOT "SCALE" DRAWINGS. USE DIMENSIONAL INFORMATION PROVIDED ONLY. FOR
DIMENSIONS NOT SHOWN OR IN QUESTION, CONTRACTOR SHALL REQUEST CLARIFICATION
FROM ARCHITECT PRIOR TO PROCEEDING.
5. ALL DIMENSIONS ARE MEASURED TO FACE OF METAL AND/OR WOOD STUDS OR MASONRY
CONSTRUCTION UNLESS OTHERWISE NOTED.
6. ALL DIMENSIONS NOTED AS "CLEAR," ARE FROM FACE OF FINISH TO FACE OF FINISH.
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:2
:4
A
M C
U se rs
\T Y
LE
R
M
C D
A N
IE
L\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a lls v tm cd a n ie lZ
LN
U
.r v t
A102
TA
ZE
W
EL
L H
A
LL
S
EC
O N
D F
LO
O
R P
LA
N
18630
PROJECT CODE: 260-18721-002
TWM
TWM
EFS
03/20/2026
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN - TAZEWELL HALL SECOND FLOOR
WORK
AREA
SCALE: 1/4" = 1'-0"A102
2 TAZEWELL SECOND FLOOR NEW WORK
SCALE: 1/4" = 1'-0"A102
1 TAZEWELL SECOND FLOOR DEMOLITION PLAN
TAZEWELL HALL DEMOLITION NOTES
1 REMOVE EXISTING CASEWORK, EYEWASH STATION AND EMERGENCY SHOWER. RETAIN
PLUMBING FOR NEW EMERGENCY SHOWER AND EYEWASH STATION.
2 REMOVE CASEWORK FROM FLOOR, RETAIN FOR RELOCATION ELSEWHERE
3 RELOCATE EXISTING CABINET
4 REMOVE GAS OUTLETS. CAP OFF UNDER CASEWORK.
5 REMOVE GAS OUTLETS. CAP OFF UNDER FLOOR.
6 REMOVE COUNTERTOP AND PREPARE EXISTING CASEWORK FOR NEW COUNTERTOP
SURFACE.
7 REMOVT VCT FLOORING AND BASE. PREPARE SURFACE FOR NEW FLOORING.
8 PROVIDE TEMPORARY DUSTPROOF BARRIER DURING CONSTRUCTION. MAINTAIN FREE
EGRESS PATH. BARRIER SHALL BE CONSTRUCTED OF ONE-HOUR FIRE RATED PARTITION
PER UL U419.
9 45-MIN. TEMPORARY FIRE RATED DOOR.
10 RELOCATE REFRIGERATOR, REFER TO 2/A102
TAZEWELL HALL CONSTRUCTION NOTES
1 PLACE TINTED FILM ON WINDOW (INTERIOR)
2 RELOCATED LAB TABLE
3 NEW CHEMICAL RESISTANT LAB COUNTERTOPS TO BE MOUNTED ON TOP OF EXISTING CASEWORK.
4 ANCHOR LOOSE TABLE TO FLOOR.
5 NEW LVT FLOORING AND RUBBER BASE
6 ELIMINATE ALL LOCKS ON CASEWORK, TYP
7 REFER TO ELECTRICAL DRAWINGS FOR POP-UP OUTLETS, TYP. IF UPPER DRAWERS INTERFERE WITH THE
OUTLET COMPONENTS, REMOVE INTERIOR PORTION OF TOP DRAWERS AND PERMANENTLY FIX THE
DRAWER PLATES TO THE CASEWORK.
8 LOWER HEIGHT TO 2'-10", THIS SECTION. REFER TO ELEVATION 3/A102
10 NEW EYEWASH STATION AND EMERGENCY SHOWER, REFER TO MEP DWGS
11 DOOR CLEARANCE REQUIREMENT
12 EYE WASH STATION 30" X 48" CLEAR FLOOR SPACE REQUIREMENT
13 RELOCATE EXISTING REFRIGERATOR HERE
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
SO
U
TH
W
ES
T V
IR
G
IN
IA
C O
M M
U N
IT
Y
C O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
OS
OS
0"
0"
M
IN
5"
NEW SOLID SURFACE
COUNTERTOP
NEW SOLID SURFACE
COUNTERTOP
NEW DRAWER UNIT
REMOVE CABINET BASE TO RELOCATE
CASEWORK ONTO NEW MOVABLE BASE
REMOVE EXISTING COUNTERTOP.
PREPARE EXISTING CASEWORK FOR NEW
CHEMICAL RESISTANT COUNTERTOP.
EXISTING CASEWORK
N O
G R
EA
TE
R T
H A
N
NEW CHEMICAL RESISTANT COUNTERTOP
A103A103
3/4" PLYWOOD
2 X 4 FRAME
LOCKING CASTER WHEELS
EXISTING CASEWORK
FIX WORKSTATION LEGS TO
FLOOR WITH L-BRACKETS
A103A103
COUNTERTOP
WOOD STUD
FRAME BELOW
FIX WORKSTATION LEGS TO
FLOOR WITH L-BRACKETS
1"
5'-0"
N O
G R
EA
TE
R T
H A
N
3/4" PLYWOOD
NEW CHEMICAL
RESISTANT COUNTERTOP
LOCKING CASTER WHEELS
EXISTING CASEWORK
5'-6" 3'-4" 5'-6"
2'-10" 2'-8"
6"
0"
6" 6"
6"
NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD BEFORE FABRICATION
R
EA
C H
D
IST.
1'-9"
POP-UP TOWER
RECEPTACLE, TYP.
OCCURS WHERE ARE INDICATED ON DRAWINGS.#
SCALE: 1/4" = 1'-0"A103
1 SECOND FLOOR REFLECTED CEILING PLAN
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:2
:4
A
M C
U se rs
\T Y
LE
R
M
C D
A N
IE
L\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a lls v tm cd a n ie lZ
LN
U
.r v t
A103
TA
ZE
W
EL
L H
A
LL
S
EC
O N
D F
LO
O
R R
C P
A N
D
C A
SE
W
O R
K D
ET
A
IL
S
18630
PROJECT CODE: 260-18721-002
TWM
TWM
EFS
03/20/2026
SCALE: 1/8" = 1'-0"
4' 8'0 16'
KEY PLAN - TAZEWELL HALL SECOND FLOOR
WORK
AREA
SCALE: 1/2" = 1'-0"A102 A103
2 ACCESSIBLE WORK STATION
SCALE: 1/2" = 1'-0"A102 A103
4 WORKSTATION 1 - NEW ELEVATION
SCALE: 1/2" = 1'-0"A102 A103
3 WORKSTATION 1 - DEMO ELEVATION
SCALE: 1/2" = 1'-0"A103 A103
8 WORKSTATION 1 - SECTION
SCALE: 1/2" = 1'-0"A102 A103
6 WORKSTATION 1 - PLAN
SCALE: 1/2" = 1'-0"A102 A103
7 WORKSTATION 2 - PLAN
SCALE: 1/4" = 1'-0"A102 A103
5 WORKSTATION 2 - ELEVATION
SCALE: 1/2" = 1'-0"A102 A103
9 TYP WORKSTATION COUTERTOP PLAN
TAZEWELL HALL CEILING NOTES
1 NEW CEILING GRID AND PANELS
2 PROVIDE 38" X 38" ACCESS PANEL. REFER TO MECHANICAL DWGS.
REPLACE CEILING TILES WITH NEW TILES WITH WHITE FINISH.
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
OBSTRUCTED HIGH SIDE REACH 2017 ICC A117.1 308.3.2OBSTRUCTED HIGH FORWARD REACH 2017 ICC A117.1 308.2.2
SCALE: 1/4" = 1'-0"
2' 4'0 8'
SCALE: 1/2" = 1'-0"
1' 2'0 4'
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
GENERAL FINISH NOTES:
1. TRANSITION BETWEEN DIFFERENT FLOOR FINISH MATERIALS OR COLORS
SHALL BE PROVIDED UNDER CENTERLINE OF DOORS UNLESS OTHERWISE
NOTED. PROVIDE ADA COMPLIANT TRANSITION STRIP.
2. PAINT ALL HOLLOW METAL DOORS AND FRAMES, METAL STAIRS, STEEL PIPE
HANDRAILS/GUARDRAILS, AND ALL OTHER MISCELLANEOUS FERROUS METALS
WITHIN EACH SPACE.
3. PROVIDE MOISTURE- AND MOLD-RESISTANT GYPSUM CEILINGS IN LIEU OF
STANDARD GYPSUM CEILINGS AT ALL LAVATORY, TOILET, AND SHOWER
AREAS.
4. REFER TO REFLECTED CEILING PLAN ON A801 FOR CEILING HEIGHTS
SCHEDULED AS "VARIES".
5. SUPPORT FOR PARTITIONS SHALL BE ADEQUATE TO RESIST A LATERAL LOAD
OF 5 PSF PER VUSBC 1607.16.
FINISH SCHEDULE LEGEND
PNT PAINTED FINISH (COLOR TBD)
ACT ACOUSTIC CEILING TILE
RUB-1 4-INCH RUBBER WALLBASE (COLOR TBD)
LVT LUXURY VINYL TILE (PATTERN TBD)
RUB-2 4-INCH RUBBER WALLBASE (COLOR TBD)
NON-RATED PARTITION
F
TYPE
F 3 5/8"
STUD
SIZE
CEILING, REFER TO
FINISH SCHEDULES
FIN FLR
4 1/4"
PART.
THICK.
SOUND ATTN
BLANKET
3"
1-LAYER OF 5/8" GWB,
LEVEL 5 FINISH
METAL STUD AT 16" ON CENTER
(SEE SCHEDULE BELOW)
M
IN6"
P
ER
F
IN
IS
H
S C
H
ED
U
LE
NEW OR EXISTING
SUBSTRATE
UNDERSIDE OF
DECK/STRUCTURE
NON-RATED PARTITION
G
TYPE
G 7/8"
STUD
SIZE
CEILING, REFER TO
FINISH SCHEDULES
FIN FLR
1 1/2"
PART.
THICK.
SOUND ATTN
BLANKET
NONE
1-LAYER OF 5/8" GWB,
LEVEL 5 FINISH
METAL STUD AT 16" ON CENTER
(SEE SCHEDULE BELOW)
M
IN6"
P
ER
F
IN
IS
H
S C
H
ED
U
LE
NEW OR EXISTING
SUBSTRATE
UNDERSIDE OF
DECK/STRUCTURE
3 5/8"
4" RUBBER BASE
SOUND ATTN. INSUL SOUND ATTN. INSUL
PER SCHED
F
P
ER
S C
H
ED
U
LE
NOTE: REFER TO DOOR SCHEDULE FOR DOOR MATERIAL REQUIREMENTS.
REFER TO PLAN
FOR PARTITION TYPE
SEALANT JOINT AT
PERIMETER EACH SIDE
METAL STUD HEADER, REFER
TO STRUCTURAL DRAWINGS
HM FRAME
R
EF
ER
T
O P
LA
N
FO
R
P A
R
TI
TI
O
N T
YP
E
SEALANT JOINT AT
PERIMETER EACH SIDE
METAL STUD HEADER, REFER
TO STRUCTURAL DRAWINGS
HM FRAME
H1 J1
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/2
/2
:2
:4
A
M C
U se rs
\T Y
LE
R
M
C D
A N
IE
L\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a lls v tm cd a n ie lZ
LN
U
.r v t
A701
FI
N
IS
H
S C
H
ED
U
LE
A N
D N
O
TE
S
18630
PROJECT CODE: 260-18721-002
TWM
TWM
EFS
03/20/2026
SCALE: 1/8" = 1'-0"
4' 8'0 16'
FINISH SCHEDULE
ROOM NO ROOM NAME FLOOR BASE
WALLS CEILING
CommentsNORTH EAST SOUTH WEST MATERIAL HEIGHT
R218 CLASSROOM LVT RUB-1 PNT-2 PNT-2 PNT-2 PNT-2 EXIST 9'-3 3/4"
R235 SIM LAB LVT RUB-2 PNT-1 PNT-1 PNT-1 PNT-1 ACT-1 9'-11"
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
DOOR SCHEDULE
MARK
OPENING SIZE DOOR FRAME DETAILS
REMARKS
NO OF
LEAFS WIDTH HEIGHT MATERIAL THICKNESS TYPE
RATING
(MIN) GLAZING TYPE MATERIAL HEAD JAMB
R218 1 3'-0" 7'-0" HM-1 1 3/4" F 45 MIN N/A F HM-1 H1 J1
DOOR TYPES
HEAD AND JAMB DETAILS
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
MM
DG
M
= SMOKE/FIRE DAMPER
DAMPERS IN
DAMPERS IN
VERTICAL DUCT
= SMOKE DAMPER
= SMOKE DAMPER
HORIZONTAL DUCT
SIDEWALL GRILLE
SLOT TYPE GRILLE
RETURN, TRANSFER
SUPPLY DIFFUSER
EXHAUST GRILLE
GRILLE
GRILLE IDENTIFICATION
= SMOKE/FIRE DAMPER
LOUVER WITH
POINT OF DEMOLITION
SPEED CONTROLLER
POINT OF CONNECTION
3/4" DOOR UNDERCUT
NEW TO EXISTING
AND CFM RATING
or MANUAL BALANCING DAMPER or
TRANSITION
SQUARE TO ROUND
(5' MAX. RUNOUT)
FLEX DUCT
SPLITTER DAMPER
MOTORIZED DAMPER
BIRD SCREEN
S
H
UC
T
HUMIDISTAT
THERMOSTAT
TAKE-OFF WITH
IN RETURN/EXHAUST DUCT
VERTICAL RISE OR DROP
FULL RADIUS ELBOW
VERTICAL RISE OR DROP
IN SUPPLY DUCT
IN BOTTOM OF DUCT
SPIN-IN TAKE-OFF
TURNING VANES
SQUARE TURN WITH
DOUBLE THICKNESS
SPIN-IN FITTING
DOOR GRILLE
H.V.A.C. LEGEND AND SYMBOLS
RETURN DUCT
SUPPLY, EXHAUST,
BRANCH TAKE-OFF
= FIRE DAMPER
= FIRE DAMPER
SMOKE DETECTORSD
12x8
12x8
12x8 x8
12x8
~ 6"∅
12x8
8x8
12x8
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
OR
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/1
/2
:3
:0
P M
C
U se rs \s te v e n th o m a s\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a ll s v
M st h o m a s@ t-l.
co m
.r v t
M001
H V
A C
L
EG
EN
D
S, N
O
TE
S
S C
H
ED
U
LE
S
18630
SGT
SGT
SGT
03/20/2026
ROOM
CLASSROOM R218
OCCUPATION
OCCUPATION
CLASSIFICATION
DENSITY
#/1000 SQ FT
AREA
Az (SQ FT)
AREA OUTDOOR
AIRFLOW RATE
Ra (CFM/SQ FT)
# OF PEOPLE
Pz
PEOPLE OUTDOOR
AIRFLOW RATE
Rp (CFM/PERSON)
BREATHING ZONE
OUTDOOR AIR
Vbz = Rp*Pz + Ra*Az
ZONE
DISTRIBUTION
EFFECTIVENESS (Ez)
REQUIRED
OUTDOOR AIR
Voz = Vbz/Ez(CFM)
PROVIDED
OUTDOOR AIR
(CFM)
SCIENCE LABORATORIES 25 1254 0.18 31 10 536 0.8 670
DEMAND
CONTROL VENTILATION
(CFM)
OUTSIDE AIR CALCULATION
PLUMBING FIXTURE SCHEDULE
P-1 S19314BFPB "BRADLEY" BARRIER FREE COMBINATION DRENCH SHOWER AND HALO EYEWASH
P-2 BRADLEY NAVIGATOR S19-2100 EFX25 EMERGENCY THERMOSTATIC MIXING VALVE
FIXTURE CONNECTION SCHEDULE
"P" NUMBER DESCRIPTION H.W. C.W. TRAP WASTE VENT
P-1 EMERGENCY EYE WASH/SHOWER --- --- 1-1/2" 1-1/2" 1-1/2"
P-2 THERMOSTATIC MIXING VALVE 1/2" 3/4"
MARK
ERV-1
MANUFACTURER
& MODEL NUMBER
SOLER & PALAU TRCeN500-230
ERV SCHEDULE
SUMMER
EXHAUST AIR
ESP IN W.G.
SUPPLY AIR
IN W.G.
OUTDOOR AIR
TEMP ( DEG. F)
RETURN AIR
TEMP ( DEG. F)
SUPPLY AIR
TEMP ( DEG. F)
SENSIBLE
EFFECTIVENESS (%)
TOTAL
EFFECTIVENESS (%)
WINTER
MAX OUTDOOR
AIR CFM
MAX RETURN
AIR CFM
MAX SUPPLY
AIR CFM
EXHAUST AIR
ESP IN W.G.
SUPPLY AIR
IN W.G.
OUTDOOR AIR
TEMP ( DEG. F)
RETURN AIR
TEMP ( DEG. F)
SUPPLY AIR
TEMP ( DEG. F)
SENSIBLE
EFFECTIVENESS (%)
TOTAL
EFFECTIVENESS (%)
ELECTRICAL
MCA MOCPVOLTAGE/PH
UNIT
WEIGHT
LBS
208/1 2.6 15 14869.672.555.370.016.50.50.542042042053.272.580.575950.50.5420420420
MARK
DH-1
MANUFACTURER &
DUCT
MODEL NO.
SIZE
IN. X IN.
KW
NEPTRONICS DFCR 25 5 24
DUCT HEATER SCHEDULE
AMPS
AIRFLOW
CFM
10X10 208/1
VOLT/PHASE
1. PROVIDE DISCONNECT SIZED AND FUSED/NONFUSED PER MANUFACTURER'S NAMEPLATE REQUIREMENTS
2. PROVIDE FLANGED DUCT CONNECTIONS
3. HEATER SHALL HAVE SCR CONTROLS
4. HEATER SHALL HAVE AN ELECTRONIC PROPORTIONAL PLUS INTEGRAL TEMPERATURE CONTROLLER EQUAL TO
PENN SYSTEM MODEL A350P AND REMOTE SETPOINT WITH DUCT SENSOR
5. THE DESIGN SHOWN IS BASED ON NEPTRONICS DFCR EQUIPMENT AND IS INTENDED TO ONLY SHOW THE
GENERAL SIZE, CONFIGURATION, LOCATIONS, CONNECTIONS, AND SUPPORT FOR EQUIPMENT OR SYSTEMS
SPECIFIED WITH RELATION TO THE OTHER BUILDING SYSTEMS. SEE SPECIFICATION SECTION 238237 FOR
TECHNICAL REQUIREMENTS PERTAINING TO THE EQUIPMENT
MARK
PERFORMANCE
STANDARD OF SIZE
(IN. X IN.)
DIFFUSER
SIZE
(IN. X IN.)
NECK
MATERIAL FINISH DESCRIPTION NOTES
PRICE SMD 24 X 24 12 X 12 STEEL WHITE LOUVERED SUPPLY DIFFUSER 1,2,3CD1
RR1 PRICE 80D 24 X 24 24 X 24 STEEL WHITE EGG CRATE GRILLE 1,2,3
1. PROVIDE OPPOSED BLADE DAMPER.
2. PROVIDE FRAME FOR LAY-IN CEILING
3. MAX NC LEVEL SHALL BE 30
AIR DISTRIBUTION SCHEDULE
1. ERV SHALL HAVE TIMECLOCK
2. ERV SHALL INCLUDE VIBRATION ISOLATOR HANGERS
3. ERV SHALL HAVE 2 SETS OF MERV-8 FILTERS
4. PROVIDE TWO 10" GALVANIZED WALL CAPS
5. PROVIDE FLEXIBLE DUCT CONNECTIONS
7. PROVIDE A WALL MOUNTED CO2 SENSOR EQUAL TO SOLER & PALAU MODEL SC02-W
8. ERV SHALL BE HAVE TWO SPEED MOTORS
9. THE DESIGN SHOWN IS BASED ON SOLER & PALAU TRCeN500-230 EQUIPMENT AND IS INTENDED TO ONLY SHOW THE GENERAL SIZE, CONFIGURATION, LOCATIONS, CONNECTIONS, AND SUPPORT FOR EQUIPMENT OR SYSTEMS SPECIFIED WITH RELATION TO THE OTHER
BUILDING SYSTEMS. SEE SPECIFICATION SECTION 237200 FOR TECHNICAL REQUIREMENTS PERTAINING TO THE EQUIPMENT
NOT TO SCALE
ERV INSTALLATION DETAIL
CEILING
ERV
(SEE SCHEDULE)
SPRING AND FIBERGLASS
VIBRATION ISOLATORS
SUPPLY AIR
FLEXIBLE CONNECTION
THREADED ROD HANGER
AIR
RETURN
TURNING VANES
NOT TO SCALE
1"R
VANES SHALL BE SECURLEY
FASTENED TO RUNNERS.
RUNNER
TYPES
INSTALL VANES IN SECTIONS
* MAXIMUM UNSUPPORTED
VANE 72
OR USE TIE RODS TO
LIMIT THE UNBACKED
VANE LENGTH.
VANE 60
VANE LENGTH
SMALL DOUBLE
LARGE DOUBLE
o o
22 Ga.
2-1/4"R
4-1/2"R
MIN.
VANES
Ga.
2-1/4" 2-1/4" o
Ga.
MIN.
VANES3-1/4"
1-1/8"
IN INSTALLED OPERATING POSITION
ALL VANES SHALL BE SECURE AND STABLE
1-1/2"
4-1/2"
OR
7"
BOLT, SCREW, OR
SCREW EVERY
WELD TO DUCT
6TH VANE
2"R
1-1/8"
2-1/8" o o o
NOTE:
EXTERNALLY AS PER SPECIFICATIONS
ALL SUPPLY AIR DUCT SHALL BE WRAPPED
"NO POP RIVETS ALLOWED"
DUCT STRAP HANGER DETAIL
METAL SCREW STRAPS TO BE TIGHT AGAINST DUCT.
SELF TAPPING CADMIUM PLATED HEX HEAD SHEET
MAXIMUMHORIZONTALMAX.
1/4" ROUND ROD
1"x18" GAGE STRAP
1/4" ROUND ROD
5/16" ROUND ROD
3/8" ROUND ROD
NOT TO SCALE
84"
48"
60"
30"
36"
SIDE
HANGER
SUPPORT ANGLE
2" x 2" x 1/8"
1-1/2"x1-1/2"x1/8 "
NONE REQUIRED
SPACING
8'-0"
8'-0"
8'-0"
8'-0"
10'-0"
HANGER SIZES FOR RECTANGULAR DUCT
HANGER STRAPS
2" x 2" x 1/8"
2" x 2" x 1/8"
ROUND DUCT HANGER DETAIL
NOT TO SCALE
18 GAx1" STRAP
3/8"∅ THREADED ROD
ON DRAWING
SIZE AS SHOWN
ROUND DUCT
12'-0" MAXIMUM
DUCT HANGER
SPACING
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
670 230
PROJECT CODE: PROJECT 260-18721-002
MIN OUTDOOR
AIR CFM
MIN RETURN
AIR CFM
MIN SUPPLY
AIR CFM
230230230
MAX OUTDOOR
AIR CFM
MAX RETURN
AIR CFM
MAX SUPPLY
AIR CFM
MIN OUTDOOR
AIR CFM
MIN RETURN
AIR CFM
MIN SUPPLY
AIR CFM
230230230
03/20/2026
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
FIGURE A
FIGURE B
MAXIMUM SAG IS
1/2" PER FOOT OF
DUCT SHOULD EXTEND
STRAIGHT FOR SEVERAL
INCHES FROM A CONNECTION
BEFORE BENDING.
SUPPORT SPACING
CLOSER MAXIMUM INTERVALS MAY
BE SPECIFIED AS A CONDITION OF
U.L. LISTING. PARTICULARLY IN
FIRE RATED FLOOR - CEILING
ASSEMBLIES.
5'-0" MAX.
5'-0" MAX.
TYPE "A" VANES
TYPE "B" VANES
RADIUS "F" = 2" RADIUS "G" = 1"
RADIUS "F" = 4-1/2" RADIUS "G" = 2-1/4"
PROVIDE 1 STAY FOR DUCTS 12"
TO 120" WIDE AND 2 STAYS AT 1/3
POINTS FOR 120" AND ABOVE
"G"
DOF ELBOW 45°C
"D" AND "D" UP TO 24"
VANES PRE-ASSEMBLED ON
RUNNERS IN ALL CASES
AIR FLOW
TYPE "B" VANES
TYPE "A" VANES
"D" AND "D" OVER 24"
L
E = 1"C = 1/4"
A = 3-1/4" A = 1-1/2"
C = 1/2"
D
C
E = 2-1/4" B = 9" B = 5"
C
NEEL VANE
OF VANES 50°L
GALVANIZED SHEET METAL VANES
AND PLATES SAME GAUGE AS DUCT
WELD VANES TO PLATE OR ATTACH
WITH ANGLE BRACKETS RIV.
B A
RADIUS
RADIUS "F"
E
E E
C
AIR FLOW
45°
PROVIDE CONCEALED CEILING DAMPER REGULATOR
SPECIFICATIONS
OPPOSED BLADE
DAMPER AS PER
NOTE:
EXTERNALLY AS PER SPECIFICATIONS
ALL SUPPLY AIR DUCT SHALL BE WRAPPED
"NO POP RIVETS ALLOWED"
METAL SCREW STRAPS TO BE TIGHT AGAINST DUCT.
SELF TAPPING CADMIUM PLATED HEX HEAD SHEET
MAXIMUMHORIZONTALMAX.
1/4" ROUND ROD
1"x18" GAGE STRAP
1/4" ROUND ROD
5/16" ROUND ROD
3/8" ROUND ROD84"
48"
60"
30"
36"
SIDE
HANGER
SUPPORT ANGLE
2" x 2" x 1/8"
1-1/2"x1-1/2"x1/8 "
NONE REQUIRED
SPACING
8'-0"
8'-0"
8'-0"
8'-0"
10'-0"
HANGER SIZES FOR RECTANGULAR DUCT
HANGER STRAPS
2" x 2" x 1/8"
2" x 2" x 1/8"
= UNIT TOTAL STATIC PRESSURE + 2"A
"A"
DRAIN SIZE
NOTE:
CONTRACTOR TO PROVIDE PROPER SUPPORT
FOR UNIT TO ALLOW FOR HEIGHT NECESSARY
TO INSTALL TRAP AND DRAIN.
DRAINAGE FITTINGS
(TYPICAL)
HVAC UNIT
(SEE SCHEDULE)
CL
TYPE "L" COPPER SWEAT IN RETURN AIR PLENUM.
FITTINGS AND PIPE TO BE SCH. 40 PVC EXCEPT
NOTE:
FULL SIZE
OF UNIT
RECTANGULAR DUCT
TO RETURN SYSTEM
DUCT SIZE
PLUS 1"
TO RETURN SYSTEM
SPIN-IN FITTING
SEE DRAWING
ROUND METAL DUCT
PLENUM
LINED DUCT
ACOUSTICAL
VARIES
RETURN GRILL
DIM
ACOUSTICAL
LINED DUCT
PLENUM
TYPE AND SIZE
SEE DRAWING FOR
RETURN GRILL
1-1/2"
VENT
1-1/2"
WASTE
3/4" COLD
WATER
1/2"HOT
WATER
EYE
WASH
SHOWER
FLOOR
DRAIN
CONNECT 1/2" HW,
3/4"CW 1-1/2" W AND
1-1/2"V
1. GENERAL
A. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO INSTALL ALL AIR CONDITIONING, HEATING AND VENTILATING WORK INDICATED ON THE DRAWINGS, SPECIFIED HEREIN, AND
IN ACCORDANCE WITH ALL CITY, STATE, AND NATIONAL CODES.
B. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS, FEES, AND INSPECTIONS. COORDINATE WITH ALL OTHER TRADES, APPLICABLE SPECS, DRAWINGS, AND OWNER'S DIRECTIONS.
C. THE MECHANICAL DRAWINGS ARE GENERALLY DIAGRAMMATIC. DO NOT SCALE THE DRAWINGS FOR EXACT SIZE OR LOCATIONS.
D. PRODUCTS SHALL BE NEW AND FIRST LINE QUALITY, OF GRADE AND TYPE SHOWN ON PLANS AND SPECIFIED, OR EQUALS AS APPROVED BY THE DESIGNER IN WRITING. ALL PRODUCTS SHALL BE IN CURRENT
PRODUCTION WITH NO NOTICE OF BEING DISCONTINUED OR DRASTICALLY CHANGED FROM CURRENT PRODUCTION.
E. MECHANICAL EQUIPMENT AND ACCESSORIES SHALL BE INSTALLED IN A NEAT WORKMANLIKE MANNER. UNSIGHTLY INSTALLATIONS SHALL BE REMOVED OR REWORKED AT NO EXPENSE TO THE OWNER.
F. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING A BID AND PRIOR TO CONSTRUCTION.
G. REFER TO ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL COORDINATION WITH THESE DRAWINGS.
H. COORDINATE ALL PENETRATIONS OF FLOOR SLABS, ROOF AND WALLS WITH STRUCTURAL DRAWINGS.
I. SEAL ALL WALL, ROOF AND FLOOR PENETRATIONS BY MECHANICAL AND ELECTRICAL SERVICE AIRTIGHT.
J. EXISTING CONDITIONS SHOWN HEREIN WERE TAKEN FROM SITE OBSERVATIONS, ORIGINAL DESIGN DRAWINGS AND AS-BUILT DOCUMENTATION WHERE AVAILABLE; ANY DISCREPANCIES BETWEEN THE PLANS AND
ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE ARCHITECT / ENGINEER.
K. HVAC CONTRACTOR SHALL REPLACE THE EQUIPMENT FILTERS AT THE TIME OF POSSESSION OF THE PROJECT BY THE OWNER, USING ONLY NEW FILTERS OF THE PROPER SIZE AND TYPE.
L. HVAC CONTRACTOR SHALL REPAIR, REPLACE, OR REPAINT TO MATCH EXISTING SURFACES DAMAGED DURING INSTALLATION OF THE MECHANICAL SYSTEM.
M. EQUIPMENT AND MATERIALS SUBMITTED AS ALTERNATES TO THE SPECIFIED DATA MUST BE CLEARLY MARKED AS TO THE DIFFERENCES IN SUBMITTED VERSUS SPECIFIED. FAILURE TO CLEARLY MARK THE SUBMITTALS
AS SUCH IS GROUNDS FOR REJECTION. SUBMITTALS NOT CLEARLY MARKED AS BEING ALTERNATE TO THE SPECIFIED DATA CAN BE ASSUMED TO MEET ALL SPECIFIED REQUIREMENTS AND THE PROVIDER IS
RESPONSIBLE TO PROVIDE AS SUCH.
2. DEMOLITION
A. THE CONTRACTOR SHALL REMOVE EXISTING HVAC EQUIPMENT, ALL ASSOCIATED ACCESSORIES AND MATERIALS AS SHOWN AND TURN OVER TO THE OWNER OR REMOVE FROM THE SITE LEGALLY IF SO DIRECTED BY
THE OWNER.
B. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY EXISTING CONDITIONS BEFORE DEMOLITION WORK BEGINS. REPORT ANY DISCREPANCIES BETWEEN THE PLANS AND ACTUAL FIELD CONDITIONS TO THE
ARCHITECT / ENGINEER PRIOR TO THE COMMENCEMENT OF DEMOLITION WORK.
C. DEMOLITION WORK SHALL BE PHASED TO ACCOMPLISH REPLACEMENT WITH MINIMUM AMOUNT OF DOWNTIME. SCHEDULE NEW AND DEMOLITION WORK IN ADVANCE WITH THE OWNER.
3. EQUIPMENT
A. THE MECHANICAL SYSTEM(S) SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
B. ALL EQUIPMENT SHALL BE U.L. LISTED.
C. CONTRACTOR SHALL VERIFY ELECTRICAL VOLTAGE, LOADS ETC. WITH ELECTRICAL TRADE, OR EXISTING CONDITIONS, PRIOR TO ORDERING EQUIPMENT.
D. EQUIPMENT SELECTIONS SHOWN ON THE DRAWINGS ARE THE BASIS OF DESIGN. ACTUAL INSTALLED EQUIPMENT AND DIFFERENT MANUFACTURERS MAY DIFFER FROM THAT SHOWN. EQUIPMENT TYPE, PHYSICAL
SIZE, CLEARANCES, WEIGHT, CAPACITIES AND PERFORMANCE CHARACTERISTICS SHALL BE GOVERNING FACTORS IN SUBMITTING SUBSTITUTIONS FOR REVIEW AND APPROVAL. COORDINATE EQUIPMENT ELECTRICAL
REQUIREMENTS WITH THE ELECTRICAL DRAWINGS.
E. EQUIPMENT SHALL OPERATE QUIETLY. THE OPERATION OF THE EQUIPMENT SHALL CAUSE NO PERCEPTIVE VIBRATION OR OBJECTIONABLE NOISE IN ANY PORTION OF THE BUILDING OR STRUCTURE.
F. DO NOT BLOCK FILTER REMOVAL ON EQUIPMENT WITH PIPING, DUCTWORK, ETC. DEMONSTRATE FILTER REMOVAL TO OWNER'S REPRESENTATIVE FOR EACH UNIT AS PART OF TRAINING.
G. PROVIDE STARTERS, INTERNAL PROTECTION, OR OTHER DEVICES INDICATED ON DRAWINGS. COORDINATE VOLTAGE, PHASE, AMPERAGE, AND OTHER REQUIREMENTS WITH ELECTRICAL DRAWINGS. UNLESS OTHERWISE
NOTED, SERVICE DISCONNECTS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY ELECTRICAL CONTRACTOR.
H. PROVIDE SUCTION LINE ACCUMULATOR FOR REFRIGERANT LINES OVER 70 EQUIVALENT LINEAL FEET (MAX LENGTH 120 FEET). VERIFY WITH MANUFACTURER.
I. FURNISH A FIVE-YEAR WARRANTY ON AIR CONDITIONING COMPRESSOR UNIT AND PROVIDE A ONE-YEAR SERVICE AND GUARANTEE ON ALL NEW CONTROLS AND EQUIPMENT. CONTRACTOR SHALL REPLACE ANY
DEFECT IN MATERIAL OR WORKMASHIP FOR (1) ONE YEAR FROM DATE OF ACCEPTANCE. DATE OF ACCEPTANCE IS DATE CERTIFIED BY ARCHITECT / ENGINEER THAT CONTRACT HAS BEEN SATISFACTORILY COMPLETED
IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
MECHANICAL NOTES & SPECIFICATIONS
4. AIR DISTRIBUTION
A. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FEET FROM ANY EXHAUST OR OUTLET VENT.
B. PROVIDE REMOTE TEMPERATURE SENSOR LOCATED IN THE RETURN DUCT UPSTREAM OF OUTSIDE AIR CONNECTION AND DOWNSTREAM OF ALL BRANCH RETURN CONNECTIONS.
C. DUCTWORK:
a. DUCTWORK SHALL BE GALVANIZED SHEET METAL, UNLESS OTHERWISE NOTED, AND INSTALLED ACCORDING TO SMACNA STANDARDS.
b. PROVIDE FLEXIBLE CONNECTORS BETWEEN DUCTWORK AND ALL EQUIPMENT / FANS.
c. ALL ROUND DUCTWORK ELBOWS SHALL BE RADIUS TYPE WITH CENTERLINE RADIUS EQUAL TO 1.5 X DIAMETER. RECTANGULAR DUCT ELBOWS SHALL BE RADIUS TYPE WITH CENTERLINE RADIUS EQUAL TO 1.5 X WIDTH WHERE INSTALLATION
PERMITS. SQUARE THROATED ELBOWS WITH SINGLE WALL TURNING VANES SHALL BE USED WHERE RADIUS TYPE RECTANGULAR DUCT ELBOWS CAN NOT BE PRACTICALLY INSTALLED. FABRICATE AND INSTALL PER SMACNA STANDARDS.
d. DUCTWORK DIMENSIONS GIVEN ARE INSIDE CLEAR.
e. CONTRACTOR SHALL VERIFY CLEARANCE REQUIREMENTS AND INDICATED ROUTING OF DUCTWORK PRIOR TO FABRICATION AS RISES AND DROPS MAY BE NECESSARY DUE TO THE TRUSS FRAMING SYSTEM.
f. VARIATION OF DUCT CONFIGURATION OR SIZES OTHER THAN THOSE OF EQUIVALENT OR LOWER LOSS COEFFICIENT IS NOT PERMITTED EXCEPT BY WRITTEN PERMISSION. SIZE ROUND DUCTS INSTALLED IN PLACE OF RECTANGULAR DUCTS IN
ACCORDANCE WITH ASHRAE TABLE OF EQUIVALENT RECTANGULAR AND ROUND DUCTS.
g. WHERE DUCTWORK CAN BE SEEN THRU GRILLES, PAINT DUCT WITH FLAT BLACK ENAMEL PAINT.
h. ALL SUPPLY, RETURN AND OUTSIDE AIR DUCTWORK SHALL BE EXTERNALLY INSULATED UNLESS OTHERWISE NOTED. INSULATE DUCT SYSTEM WITH 2.2 INCH, 3/4 LB DENSITY, FOIL FACED FIBERGLASS INSULATION WITH VAPOR BARRIER ON THE
OUTSIDE. INSTALL PER SMACNA STANDARDS. INSULATED FLEX DUCT SHALL HAVE A MINIMUM R-6 INSULATION VALUE. (EXCEPTION: DUCT LOCATED OUTSIDE THE BUILDING INSULATION LAYER SHALL BE 2 INCH, 3 LB DENSITY AND FLEX DUCT TO
BE R-8).
i. CONTRACTOR SHALL PROVIDE CERTIFIED AIR SYSTEM BALANCE. BALANCING CONTRACTOR SHALL BE AABC OR NEBB CERTIFIED. PROVIDE REPORT TO ENGINEER/ARCHITECT.
D. AIR DEVICES:
1. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF GRILLES, REGISTERS AND DIFFUSERS.
2. COORDINATE GRILLE, REGISTER AND DIFFUSER LOCATIONS WITH THE LIGHTING AND CEILING GRID LAYOUT.
3. PROVIDE ALL DIFFUSERS IN THE SAME SPACE WITH THE SAME FULL-FACE SIZE USING THE LARGEST SIZE.
4. DUCT MOUNTED REGISTERS SHALL BE MOUNTED IN A COLLAR WITH SUFFICIENT LENGTH TO PREVENT DAMPERS FROM OBSTRUCTING AIR FLOW. COLLARS TO BE OVERSIZED FOR REVERSE FLANGE REGISTER MOUNTING.
5. PROVIDE COMPANION OPPOSED BLADE VOLUME DAMPERS WITH ALL DIFFUSERS MOUNTED IN DRYWALL.
5. PIPING
A. ALL CONDENSATE DRAIN LINES SHALL BE SCHEDULE 40 DWV-PVC PIPE AND FULL SIZE, OR LARGER, OF EQUIPMENT DRAIN. TRAP AND VENT AT EQUIPMENT. ROUTE TO THE NEAREST FLOOR DRAIN OR AS DIRECTED ON THE DRAWINGS. MAINTAIN A MIN.
2" AIR GAP FROM DRAIN DISCHARGE TO DRAIN TOP.
B. PROVIDE CHROME-PLATED ESCUTCHEONS AT ALL EXPOSED PIPE PENETRATIONS THROUGH WALLS.
C. THE CONTRACTOR SHALL PROVIDE A CERTIFIED HYDRONIC SYSTEM BALANCE. BALANCING CONTRACTOR SHALL BE AABC OR NEBB CERTIFIED. PROVIDE REPORT TO ENGINEER/ARCHITECT.
6. PLUMBING
A. PLUMBING FIXTURES AND ACCESSORIES SHALL BE INSTALLED IN A NEAT WORKMANLIKE MANNER. UNSIGHTLY INSTALLATIONS SHALL BE REMOVED OR REWORKED AT NO EXPENSE TO THE OWNER.
B. PROVIDE CHROME PLATED ESCUTCHEONS AT ALL EXPOSED PIPE PENETRATIONS THROUGH WALLS.
C. PROVIDE WATER STOP VALVES AT EACH EQUIPMENT ITEM.
D. COORDINATE WITH APPROVED ARCHITECTURAL DRAWINGS BEFORE ROUGHING IN PLUMBING.
E. CONTRACTOR SHALL PROVIDE AND INSTALL ALL VALVES, PRESSURE REDUCING VALVES, SHOCK ABSORBERS, AND ACCESSORIES TO COMPLETELY INSTALL ALL EQUIPMENT AND MAKE A COMPLETE INSTALLATION.
F. ALL VENTING OF FIXTURES SHALL COMPLY WITH LOCAL CODES AND ORDINANCES.
G. USE DIELECTRIC UNIONS WHERE PIPE OF DIFFERENT MATERIALS ARE JOINED.
H. MAKE PROPER HOT & COLD WATER, WASTE AND VENT PIPE CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL BRANCH RUNS, ELBOWS, AND CONNECTIONS ARE NOT SHOWN.
I. SERVICE VALVES SHALL BE FURNISHED AND INSTALLED ON ALL HOT AND COLD WATER LINES AT EQUIPMENT IN AN ACCESSIBLE LOCATION.
J. DOMESTIC WATER INSULATION SHALL BE FIBERGLASS PIPE INSULATION, MINIMUM DENSITY 3.5 PCF, 1/2" THICKNESS FOR COLD WATER AND 1" THICKNESS FOR HOT WATER.
K. WASTE AND VENT PIPING TO BE SCHEDULE 40 PVC, DOMESTIC WATER PIPING TO BE TYPE L OR K HARD DRAWN COPPER.
L. EQUIPMENT AND MATERIALS SUBMITTED AS ALTERNATIVES TO THE SPECIFIED DATA MUST BE CLEARLY MARKED AS TO THE DIFFERENCES IN SUBMITTED VERSUS SPECIFIED. FAILURE TO CLEARLY MARK THE SUBMITTAL AS SUCH IS
GROUNDS FOR REJECTION. SUBMITTALS NOT CLEARLY MARKED AS BEING ALTERNATE TO THE SPECIFIED DATA CAN BE ASSUMED TO MEET ALL SPECIFIED REQUIREMENTS AND PROVIDER IS RESPONSIBLE TO PROVIDE AS SUCH.
M. THE "REDUCTION IN LEAD IN DRINKING WATER ACT" REQUIRES MATERIALS AND FIXTURES USED FOR DELIVERY OF POTABLE WATER TO CONTAIN LESS THAN 0.2% LEAD FOR SOLDER AND FLUX, AND NOT MORE THAN A WEIGHT
AVERAGE 0.25% LEAD FOR PIPES, FITTINGS AND FIXTURES. EXCLUDED FROM THIS ACT ARE TOILETS, BIDETS, URINALS, FLUSHVALVES, TUBFILLERS, SHOWER VALVES. IT IS THE INTENT OF THIS PROJECT TO CONFORM WITH THE
REQUIREMENTS OF THE 2014 LEAD FREE ACT. EVERY EFFORT HAS BEEN MADE TO CALL FOR FIXTURES THAT COMPLY WITH THE ACT. EVEN SO, IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO INSTALL PRODUCTS THAT COMPLY
WITH THE 2014 LEAD FREE SAFE DRINKING WATER ACT.
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/1
/2
:3
:0
P M
C
U se rs \s te v e n th o m a s\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a ll s v
M st h o m a s@ t-l.
co m
.r v t
M002
H V
A C
D
ET
A
IL
S
18630
SGT
SGT
SGT
03/20/2026
FLEXIBLE DUCT SUPPORTS
SQUARE ELBOW DETAIL
BRANCH DUCT TAKE-OFF AT SUPPLY MAIN
DUCT STRAP HANGER DETAIL
DETAIL OF DRAIN AT UNIT
EMERGENCY EYE WASH / SHOWER PIPING
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
RETURN AIR GRILLE DUCT CONNECTIONS DETAILS
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
PROJECT CODE: PROJECT 260-18721-002
NOTE: FLUSHING FLUID FLOW PATTERN SHALL BE A MINIMIM 33" ABOVE FINISHED FLOOR.
03/20/2026
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
SIM LAB
R235
HP-1
EXISTING FAN COIL
UNIT FCU59R TO
REMAIN
PAINT EXISTING DIFFUSERS
BLACK, TYPICAL OF 2
PAINT EXISTING RETURN
GRILLE BLACK
IU-1 CLEANOUT,
TYP
3/4" COND
ROUTE TO
MOP SINK
PAINT CASSETTE
GRILLE BLACK
T
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/1
/2
:3
:0
P M
C
U se rs \s te v e n th o m a s\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a ll s v
M st h o m a s@ t-l.
co m
.r v t
M101
R U
SS
EL
L H
A
LL
S
EC
O N
D F
LO
O
R H
V A
C P
LA
N
18630
SGT
SGT
SGT
03/20/2026
KEY PLAN - RUSSELL HALL SECOND FLOOR
WORK
AREA
SCALE: 1/4" = 1'-0"
2' 4'0 8'
1/4" = 1'-0"
RUSSELL HALL SECOND FLOOR HVAC PLAN
OUTSIDE AIR CALCULATIONS
ZONE SPACES FLOOR AREA
(SQUARE FEET)
OCCUPANCY PEOPLE OUTDOOR
AIR RATE
AREA OUTDOOR
AIR RATE
BREATHING ZONE
OUTDOOR AIRFLOW (CFM)
ZONE AIR DISTRIBUTION
EFFECTIVENESS
VAV-212 CLASSROOM R235 392 35 7.5 0.06
REQUIRED ZONE
OUTDOOR AIRFLOW (CFM)
138.4 0.80 173
DENSITY #/1000 SQ FT
PEOPLE
COUNT
DCV
CALCULATIONS
433X0.06/0.8=32.4
DUCTLESS MINI SPLIT SCHEDULE
MARK MANUFACTURER AND MODEL NO.
MITSUBISHI SLZ-AF09NL/SUZ-AA09NLIU-1/HP-1
TRUE
NORTH
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
PROJECT CODE: PROJECT 260-18721-002
VENTILATON TABLE FOR FAN COIL UNITS FROM EXISTING DRAWINGS
STYLE
CEILING
CFM
SUPPLY
COOLING CAPACITY (MBH)
9.0
MAXIMUM MINIMUM
2.3
HEATING CAPACITY (MBH)
7.8
@ 17 DEG F
ELECTRICAL
208/1
VOLT/PH
0.25
MCA
WEIGHT
LBS
INDOOR UNIT
COOLING CAPACITY (MBH)
9.0
MAXIMUM MINIMUM
2.3
HEATING CAPACITY (MBH)
7.8
@ 17 DEG F
ELECTRICAL
208/1
VOLT/PH
MCA
OUTDOOR UNIT
MOCP
REFRIGERANT PIPE SIZES
GAS LIQUID
3/8" 1/4"
WEIGHT
LBS SEER
81 21.0
HSPF
11.8
1. INDOOR UNIT IS POWERED BY OUTDOOR UNIT
2. PROVIDE DISCONNECT SIZED AND FUSED/NONFUSED PER MANUFACTURER NAMPLATE REQUIREMENTS
3. PROVIDE WALL MOUNTED WIRELESS THERMOSTAT
4. PROVIDE ALL REQUIRED REFRIGERANT ACCESSORIES
5. OUTDOOR UNIT SHALL BE MOUNTED ON A MINIMUM 4 INCH THICK CONCRETE PAD WITH A MINIMUM OF 3 INCHES ABOVE GRADE. PAD SHALL BE 4" LARGER THAN UNIT IN ALL DIRECTIONS, CHAMFER ALL EDGES 45 DEGREES.
6. REFRIGERANT LINES SHALL BE INSULATED WITH 3/4" THICK ELASTOMERIC INSULATION. EXTERIOR INSULATION SHALL BE PAINTED WITH 2 COATS OF UV PROTECTIVE COATING.
7. PROVIDE LOCKING TYPE TAMPER RESISTANT CAPS ON REFRIGERANT ACCESS PORTS LOCATED OUTDOORS.
8. PROVIDE 120V CONDENSATE PUMP; ROUTE 3/4" PVC CONDENSATE TO MOP SINK
9. UNIT SHALL HAVE LOW AMBIENT COOLING.
10. THERMOSTAT SETPOINTS:
OCCUPIED COOLING SETPOINT: 75 DEG F
OCCUPIED HEATING SETPOINT: 70 DEG F
UNOCCUPIED COOLING SETPOINT: 85 DEG F
UNOCCUPIED COOLING SETPOINT: 55 DEG F
11. REFRIGERANT SHALL BE R-454B
12. THE DESIGN SHOWN IS BASED ON MITSUBISHI SLZ/SUZ AND IS INTENDED TO ONLY SHOW THE GENERAL SIZE, CONFIGURATION, LOCATIONS, CONNECTIONS, AND SUPPORT FOR EQUIPMENT OR SYSTEMS SPECIFIED WITH RELATION TO OTHER BUILDING SYSTEMS. SEE SPECIFICATION SECTION 238150 FOR TECHNICAL
REQUIREMENTS PERTAINING TO THE EQUIPMENT.
AIR COOLED CONDENSING UNIT DETAIL
CONTROL ACCESS PANEL
REFRIGERANT
LIQUID LINE
BACK-SEATED REFRIGERANT
CONNECTION (TYPICAL)
VALVE (TYPICAL)
REFRIGERANT GAUGE
HANDLE FOR MOVING
CONCRETE PAD 4" LARGER THAN
(OR AS REQ'D. BY MANUFACTURER)
UNIT IN EACH DIRECTION, 4" THICK
NOT TO SCALE
CONTROLPOWER
CONDUIT CONDUIT
FAN GUARD
CONDENSING COIL
MOISTURE INDICATOR
LINE WITH INSULATION
REFRIGERANT SUCTION
SIGHT GLASS WITH
(PROVIDE LOCKING CAPS ON REFRIGERANT SERVICE VALVES)
WITH A MINIMUM OF 3" ABOVE GRADE
03/20/2026
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
CLASSROOM
R218
EXISTING FLOOR MOUNTED
FAN COIL UNIT TO REMAIN
EXISTING FLOOR MOUNTED
FAN COIL UNIT TO REMAIN
EXISTING FLOOR MOUNTED
FAN COIL UNIT TO REMAIN
EX
P-2
P-1
EXISTING FLOOR DRAIN TO REMAIN
CONNECT 1/2" HW, 3/4" CW, 1-1/2" WASTE AND
1-1/2" VENT TO EXISTING
CLEAN CEILING GRILLE PER MANUFACTURER RECOMMENDATIONS
DH-1 1
"x
ERV-1
"x
10"x10"
"x
WALL CAP
WALL CAP
PROVIDE 38"X38" ACCESS PANEL
UNDER UNIT FOR MAINTENANCE
CD1
RR1
MAINTENANCE ACCESS
THROUGH CEILING TILE
M
M
MOTORIZED
DAMPER,
TYPICAL
CLASSROOM
R218
EXISTING FLOOR MOUNTED
FAN COIL UNIT TO REMAIN
EXISTING FLOOR MOUNTED
FAN COIL UNIT TO REMAIN
EXISTING FLOOR MOUNTED
FAN COIL UNIT TO REMAIN
DEMO GAS PIPING IN LAB CABINETRY,
CAP GAS LINE SERVICING LAB BURNERS IN
1ST FLOOR CEILING SPACE BELOW
DEMO GAS PIPING IN LAB CABINETRY,
CAP GAS LINE SERVICING LAB BURNERS IN
1ST FLOOR CEILING SPACE BELOW
DEMO GAS PIPING IN LAB CABINETRY,
CAP GAS LINE SERVICING LAB BURNERS
IN 1ST FLOOR CEILING SPACE BELOW
EXISTING FLOOR DRAIN TO REMAIN
EXISTING OUTSIDE AIR DUCT AND GRILLE TO REMAIN
DISCONNECT HOT WATER, COLD WATER, AND WASTE
FROM EXISTING EMERGENCY SHOWER/EYE WASH
DEMO EXISTING EMERGENCY SHOWER/
EYE WASH
EXISTING GAS LINE UP FROM
FLOOR BELOW, TYPICAL
DEMO EXISTING
BUNSEN BURNERS,
TYPICAL
DEMO EXISTING
BUNSEN BURNERS,
TYPICAL
DEMO EXISTING
BUNSEN BURNERS,
TYPICAL
DEMO EXISTING
BUNSEN BURNERS,
TYPICAL
DEMO EXISTING
BUNSEN BURNERS,
TYPICAL
Sheet
No.
Designed
Drawn
Checked
Date
Project No.
D a te /T im e
Fi le N a m e
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
/1
/2
:3
:0
P M
C
U se rs \s te v e n th o m a s\
D o cu m e n ts \1
S W
C C
R u ss e ll
T a ze w e ll
H a ll s v
M st h o m a s@ t-l.
co m
.r v t
M102
TA
ZE
W
EL
L H
A
LL
S
EC
O N
D F
LO
O
R H
V A
C P
LA
N
18630
SGT
SGT
SGT
03/20/2026
SCALE: 1/4" = 1'-0"
2' 4'0 8'
KEY PLAN - TAZEWELL HALL SECOND FLOOR
WORK
AREA
1/4" = 1'-0"
TAZEWELL HALL SECOND FLOOR HVAC PLAN - NEW WORK
1/4" = 1'-0"
TAZEWELL HALL SECOND FLOOR HVAC PLAN - DEMO
SEQUENCE OF OPERATIONS
THE ENERGY RECOVERY UNIT AND DUCT HEAT WILL BE ENABLED BY A TIME CLOCK.
OCCUPIED MODE:
DURING OCCUPIED PERIODS THE ENERGY RECOVERY UNIT WILL RUN TO MAINTAIN MINIMUM VENTILATION REQUIREMENTS.
UNOCCUPIED MODE:
DURING UNOCCUPIED PERIODS THE UNIT WILL REMAIN DISABLED. THE EXISTING PRIMARY HVAC EQUIPMENT WILL CONTROL THE SPACE TO UNOCCUPIED SETPOINTS.
HEAT MODE:
AN ELECTRIC DUCT HEATER WILL BE FIELD INSTALLED IN THE ERV SUPPLY DUCT.
WHEN THE TIME CLOCK HAS ENABLED THE ERV FOR OCCUPIED MODE, A FIELD INSTALLED JOHNSON CONTROLS CONTROLLER A350P CONTROLLER WILL USE THE DISCHARGE AIR TEMPERATURE FROM THE REMOTE DUCT SENSOR AND DISCHARGE AIR TEMPERATURE SETPOINT TO
DETERMINE WHEN TO INITIATE REQUESTS FOR HEAT.
WHEN THE DISCHARGE AIR TEMPERATURE DROPS BELOW THE DISCHARGE AIR TEMPERATURE SETPOINT (70 DEG. - ADJUSTABLE), THE UNIT CONTROLLER WILL ENABLE ELECTRIC HEATING TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. THE A350P WILL SEND A 2-10VDC
OR 4-20MA SIGNAL TO THE SCR HEATER TO CONTROL THE HEAT TO A DISCHARGE AIR SETPOINT OF 90 DEGREES (ADJ). ONCE THE DISCHARGE AIR TEMPERATURE RISES ABOVE THE DISCHARGE AIR TEMPERATURE SETPOINT PLUS DIFFERENTIAL OF 3 DEGREES THE ELECTRIC HEATING
WILL BE DISABLED.
THE DUCT HEATER SHALL BE EQUIPPED WITH A FACTORY AIR FLOW PROVING SWITCHES AND OVER TEMPERATURE SAFETIES. THE TIME CLOCK MUST HAVE THE DUCT HEATER ENABLED, AIR FLOW THROUGH THE HEATER MUST BE ESTABLISHED AND ALL SAFETIES WILL BE CLOSED
BEFORE THE ELECTRIC HEAT CAN BE ENABLED.
DEMAND CONTROL VENTILATION:
USING A SPACE CO2 INPUT LOCAL SENSOR, THE ERV INERNAL CONTROLLER SHALL MONITOR AND COMPARE THE MEASURED SPACE CO2 TO THE SPACE CO2 CONCENTRATION SETPOINT (1000 PPM (ADJ.)) WHEN THE MEASURED SPACE CO2
CONCENTRATION REACHES THE SETPOINT (ADJ.) FOR LONGER THAN 5 MINUTES, THE ERV SHALL OPERATE AT THE MAXIMUM CFM SETTING. WHEN THE MEASURED CO2 CONCENTRATION FALLS BELOW THE SPACE CO2 CONCENTRATION SETPOINT
FOR LONGER THAN 5 MINUTES, THE ERV SHALL OPERATE AT THE MINIMUM ERV CFM SETPOINT.
MOTORIZED DAMPERS:
MOTORIZED DAMPERS IN THE OUTSIDE AIR AND EXHAUST DUCTS SHALL BE INTERLOCKED WITH THE ERV TO OPEN WHEN THE ERV IS ENERGIZED AND CLOSE WHEN THE ERV IS NOT ENERGIZED.
TRUE
NORTH
TRUE
NORTH
N o
D at e
P u rp o se o f D o cu m e n t
Is su e
NOTE: INTERLOCK MOTORIZED DAMPERS WITH ERV
PROJECT CODE: PROJECT 260-18721-002
SEAL FLASHING WITH JOINT
AND SEAM FILLER
METAL FLASHING
VENT HOOD BLOCKING,
TYPICAL OF 2
ALUMINUM VENT HOOD WITH
INSECT SCREEN AND BACKDRAFT
DAMPER
FILL AROUND SEAMS WITH
FOAM ADHESIVE
DUCT
PVC PIPE 2" LARGER
THAN DUCT
THROUGH WALL
FILL SPACE BETWEEN
PVC PIPE AND DUCT WITH
SPRAY FOAM INSULATION
NOT TO SCALE
WALL CAP INSTALLATION DETAIL
03/20/2026
SO
U
TH
W
ES
T
V
IR
G
IN
IA
C
O M
M U
N
IT
Y C
O
LL
EG
E
R U
SS
EL
L H
A
LL
A N
D T
A
ZE
W
EL
L H
A
LL
L A
B R
EN
O
V A
TI
Sheet No.
Designed
Drawn
Checked
Date
Project No.
18630
03/20/2026
N o.
Da te
Pu rp os e of D oc um en t I ss ue
PROJECT CODE: 260-18721-002
JTS
RMA
RMA
Seal
STATE BUILDING OFFICIAL APPROVAL STAMP
E001
GE
N
ER
AL
N O
TE
S, L
EG
EN
D, AB
BR
EV
IA
TI
O
N S, A N
D
DE
TA
IL
S
1. ALL NOTES, SYMBOLS AND ABBREVIATIONS MAY NOT BE APPLICABLE TO THIS PROJECT.
2. COMPLY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .