Sunshade_Drawings.pdf
PDF 678 KB Posted
- Solicitation number
- FA481927R9999
- Issued by
- Bay County, Florida
About this file
This is a design submittal document prepared by GM Hill Engineering for the U.S. Army Corps of Engineers, Mobile District, detailing the construction specifications for Flight Line F-35 Sunshades at Tyndall Air Force Base in Florida. The project involves the design and installation of six aircraft sunshade structures, each approximately 630 feet in length, 65 feet in width, and 30 feet in height, configured with six bays per structure. The structures feature hot-dipped galvanized and painted steel portal frame systems with standing seam metal roofs, eave heights of 26 feet from the top of pedestal, aluminum downspouts, and comprehensive bird deterrent systems including continuous bird deterrent spike strips and bird netting at horizontal structural elements. The design includes detailed specifications for site conditions, demolition, environmental controls, electrical systems with lightning protection and grounding plans, and lighting infrastructure. The bid schedule identifies a base bid for Sunshades 2 and 3, with four additional options for Sunshades 1, 4, 5, and 6. The project documents include comprehensive civil, architectural, structural, and electrical drawing sets, with the design submittal dated June 9, 2023.
The project specifications require conformance to Tyndall Air Force Base installation facility standards for similar buildings within the Flight Line planning district, with all finishes to match existing facility standards. The roof components, roof flashing, fascias, trims, gutters, and downspouts are specified in matte metallic silver white, while exposed structural framework employs hot-dipped galvanized steel with dark gray paint finish. The design includes provisions for aircraft clearance envelopes, vertical reflective tape on both sides of each frame for visibility, continuous bird screen fabric on roof undersides, and comprehensive electrical infrastructure including site plans, power plans, lighting plans, and riser diagrams. The Total Small Business Set-Aside designation applies to this contract, classified under NAICS code 238990 for All Other Specialty Trade Contractors.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GMHILL
G.M. HILL ENGINEERING
9700 PHILIPS HWY. SUITE 101
JACKSONVILLE, FLORIDA 32256
PH: (904) 280-8244
gmhillengineering.com
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N
P
H
IL
IP
S
H W
Y S
U
IT
E
J A
C K
S O
N V
IL
L E
F
L
T E
L -2
-8
G-001
C O
V E
R S
H E
E T
T Y
N D
A L L A
F B
F
L
M O
B
IL
E D
IS
T
R
IC
T
S
T J
O S
E P
H S
T M
O B
IL
E
A
L
G M
H
IL
L E
N G
IN
E
E R
IN
G
I N
C
T E
D
K H
R
E A
L
R K
J
U N
E
W -1
-D
-0 /0
W F
RTA DESIGN SUBMITTAL
F L
IG
H T
L
IN
E F
-3 S
U N
S H
A D
E S
W X
N J
MOBILE DISTRICT
W91278-18-D-0045/0008
W9127821F0421
09 JUNE 2023
RTA DESIGN SUBMITTAL
TYNDALL AFB, FL
FLIGHT LINE F-35 SUNSHADES
W31XNJ12657099
DRAWING INDEX
GENERAL
G-001 COVER SHEET
G-002 LOCATION AND VICINITY MAP
G-003 LAYDOWN AREA AND HAUL ROUTE
GEOTECH
B-100 BORING LOCATION PLAN
CIVIL
C-001 PROJECT NOTES, ABBREVIATIONS
AND LEGENDS
C-100 OVERALL EXISTING CONDITIONS
PLAN
C-101 EXISTING CONDITIONS PLAN
C-102 EXISTING CONDITIONS PLAN
C-103 EXISTING CONDITIONS PLAN
C-110 DEMOLITION PLAN
C-111 DEMOLITION PLAN
C-112 DEMOLITION PLAN
C-120 OVERALL ENVIRONMENTAL PLAN
C-121 ENVIRONMENTAL PLAN
C-122 ENVIRONMENTAL PLAN
C-123 ENVIRONMENTAL PLAN
C-200 OVERALL SITE PLAN
C-201 SITE PLAN
C-202 SITE PLAN
C-203 SITE PLAN
C-204 GEOMETRIC CONTROL POINT TABLE
C-210 SITE CONSTRUCTION DETAILS
C-211 SITE CONSTRUCTION DETAILS
C-212 SITE CONSTRUCTION DETAILS
C-221 JOINTING AND ELEVATION PLAN
C-222 JOINTING AND ELEVATION PLAN
C-223 JOINTING AND ELEVATION PLAN
C-500 OVERALL EROSION AND SEDIMENT
CONTROL PLAN
C-501 EROSION AND SEDIMENT CONTROL
PLAN
C-502 EROSION AND SEDIMENT CONTROL
PLAN
C-503 EROSION AND SEDIMENT CONTROL
PLAN
A
M
/2
/2
3DRAWING INDEX
C-510 EROSION AND SEDIMENT CONTROL
DETAILS
ARCHITECTURAL
A-001 GENERAL NOTES, ABBREVIATIONS
A-100 ARCHITECTURAL SITE PLAN
A-101 TYP OVERALL PLAN SUNSHADES 2
AND 5
A-102 ENLARGED PLAN - 2 BAYS-SS2
A-103 SUNSHADE ROOF PLAN
A-104 SUNSHADE REFLECTED CEILING
PLAN
A-201 ELEVATIONS
A-301 BUILDING CROSS SECTION
A-302 SITE SECTIONS
STRUCTURAL
S-001 DESIGN CRITERIA AND GENERAL
NOTES
S-002 GENERAL NOTES
S-100 STRUCTURAL SITE PLAN
S-101 TYPICAL OVERALL PLAN
SUNSHADES 2 AND 5
S-102 ENLARGED PLAN - 2 BAYS-SS2
S-103 ENLARGED PLAN - 2 BAYS-SS5
S-301 FOUNDATION SECTIONS AND
DETAILS
ELECTRICAL
E-001 ELECTRICAL LEGEND AND
ABBREVIATIONS
ES101 ELECTRICAL SITE PLAN
ES102 ELECTRICAL SITE PLAN
ES103 ELECTRICAL SITE PLAN
EG101 LIGHTNING PROTECTION PLAN
EG102 GROUNDING PLAN
EG-103 GROUNDING PLAN
EL101 ELECTRICAL LIGHTING PLANS
EL102 ELECTRICAL ROOF LIGHTING PLAN
EP101 ELECTRICAL POWER PLANS
EP102 ELECTRICAL POWER PLANS
E-501 LUMINAIRE SCHEDULE AND
LIGHTING PLATES
E-502 ELECTRICAL DETAILS
E-601 ELECTRICAL RISER DIAGRAMS
E-701 PANELBOARD SCHEDULES
DRAWING INDEX
BASE BID: SS2& SS3
OPTION 1: SS1
OPTION 2: SS4
OPTION 3: SS5
OPTION 4: SS6
BID SCHEDULE
Karen.Rutter Model
Karen.Rutter Text Box 8/28/23
A-301
__________________________________________1 2 3 4
PORTAL FRAME
HOT-DIPPED
GALVANIZED AND
PAINTED STEEL
STRUCTURAL
SYSTEM TYP.
KIOSK N.I.C.
SHOWN FOR
REFERENCE
STANDING SEAM
METAL ROOF TYP.
T.O. PEDESTAL TYP.
SEE STRUCTURAL
DWGS. TYP.
EAVE
HEIGHT
GUTTER - SLOPE FROM
MID POINT TO EA. END
MIN. 1/8" / FT.
PROVIDE FULLY SEALED
END CAPS AT EA. END
6"X6" RECT. PRE-
FINISHED ALUM.
DOWNSPOUT TYP.
AT EA. END OF
GUTTER - SECURE
TO STEEL FRAME
TYP.
STEEL FRAME
BRACING BY MET.
BLDG MANUF. TYP.
A-302
B C D E F GA
A-201
A-302
B C A
DIMENSION FROM TOP OF PEDESTAL TO TOP
OF PAVEMENT VARIES PER SLOPE OF FLIGHT
LINE APRON. MINIMUM ELEVATION FOR TOP OF
PEDESTAL IS BENCHMARK ELEVATION FOR
EACH SUNSHADE. SEE STRUCTURAL DWGS.
CL
R = 10' - 0"
R = 10' - 0"
R = 8' - 0"
R = 10' - 0"
R = 10' - 0"
R = 8' - 0"
EAVE HT. FROM
T.O. PEDESTAL
STANDING SEAM
METAL ROOF TYP.EAVE GUTTER - SLOPE FROM MID POINT TO
EA. END MIN. 1/8" / FT. (FULLY SEALED END
CAPS EA. EN TYP.
VALLEY GUTTER - SLOPE FROM MID
POINT TO EA. END MIN. 1/8" / FT.
(PROVIDE FULLY SEALED END CAP AT
EA. END TYP.)
HOT-DIPPED GALVANIZED AND
PAINTED STEEL STRUCTURAL
SYSTEM TYP.
6"X6" RECT.
PRE-FINISHED
ALUM.
DOWNSPOUT
TYP. AT EA.
END OF
GUTTER -
SECURE TO
STEEL FRAME
TYP.
6"X6" RECT. PRE-FINISHED ALUM.
DOWNSPOUT TYP. AT EA. END OF
GUTTER - SECURE TO STEEL FRAME
TYP.
T.O. PEDESTAL
A-103
SEE ELECTRICAL DWGS FOR WHICH SUNSHADES
AND WHERE LIGHT FIXTURES OCCUR
COMPONENTS PAINT / FINISH COLOR
1.
2.
NOTE:
ALL FINISHES TO MATCH THE TYNDALL AFB
INSTALLATION FACILITY STANDARDS FOR SIMILAR
BUILDINGS WITHIN THE TYNDALL FLIGHTLINE
PLANNING DISTRICT.
PRE-FINISHED METALS ARE FACTORY FINISHED AND
PAINTED FINISHES ARE FIELD OR SHOP FINISHED.
ROOF (TOP SIDE), ROOF FLASHING,
FASCIAS, TRIMS, GUTTERS AND
DOWNSPOUTS
CEILING (ROOF PANEL UNDERSIDE)
STRUCTURE, EXPOSED FRAMEWORK
(HOT-DIPPED GALVANIZED STEEL)
MATTE METALLIC SILVER
WHITE
GALVANIZED + PAINT
DARK GRAY
US Army Corps of Engineers ®
SHEET ID
U S
AR
M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N B Y:
D
ES
IG
N
ED
B Y:
SU
BM
IT
TE
D B Y:
SI
ZE
C H
EC
KE
D B Y:
AN
SI
D
IS
SU
E D
AT
E:
C O N
TR
AC
T N O
SO
LI
C
IT
AT
IO
N N O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K D
ES
C R
IP
TI
O N
P H
IL
IP
S H W Y
SU
IT
E
JA
C
KS
O N
VI
LL
E, F L
TE
L:
-2 -8
A-201
EL
EV
AT
IO
N S
TY
N D
AL
L
AF
B, F L
M O
BI
LE
D
IS
TR
IC
T
ST
J O
SE
PH
S T.
M O
BI
LE
, A L
G M H
IL
L
EN
G
IN
EE
R
IN
G
IN
C
TE
D
KH
R
EA
L
TE
D
J U N E
W 8- -D -0 5/
W 1F
RTA DESIGN SUBMITTAL
FL
IG
H T
LI
N E F- S U N
SH
AD
ES
W
XN
J1
1/8" = 1'-0"2 EAST ELEVATION
0 32'16' 64'
0 8'4' 16'
0 8'4' 16'
1/32" = 1'-0"1 SOUTH ELEVATION
1/8" = 1'-0"3 ENLARGED SOUTH ELEVATION
AM
/0 5/
M
IN
IM
U M V
ER
TI
C
AL
C
LE
AR
AN
C E
EN
VE
LO
PE
CL
BIRD DETERENT NET CONTINUOUS
AT UNDERSIDE OF PURLINS
ALL HORIZONTAL
STRUCTURE:
PROVIDE
CONTINUOUS 180D
BIRD DETERENT
SPIKE STRIPS OR
WRAPPED WITH
BIRD NET
B
A 6" M
IN
VA
R
IE
S
VERTICAL
REFLECTIVE
TAPE TYP.
BOTHSIDES EA.
FRAME
FLIGHT LINE PAVEMENT SEE
CIVIL DRAWINGS FOR
TOPOGRAPHIC AND PAVING
KIOSKS N.I.C.
BEYOND SEE
ELECTRICAL DWGS
FOR ROUGH IN
SERVICE
CONCRETE
FOUNDATIONS SEE
STRUCTURAL DWGS
NOTE:
STEEL BASE
PLATE T.O.
PEDESTAL
ELEV. IS
CONSTANT
/4
R = 10' - 0"
1' 4"
R = 10' - 0" R = 10' - 0"
R = 8' - 0" R = 8' - 0"
R = 10' - 0"
R = 10' - 0"
R = 10' - 0"
EAVE HT. FROM
T.O. PEDESTAL
EAVE GUTTER -
SLOPE FROM
MID POINT TO
EA. END MIN.
1/8" / FT.
DOWNSPOUT
TYP. EA. END
FRAME- SECURE
TO STEEL FRAME
VALLEY GUTTER - SLOPE
FROM MID POINT TO EA.
END MIN. 1/8" / FT.
1" / 1'-0" 1" / 1'-0"
MET. BLDG. SYSTEM
RIGID FRAME - WRAP
HORIZONTAL PORTION
AND OR PARTS THAT
FORM LEDGES WITH
BIRD NETTING TYP.
MET. BLDG. SYSTEM
RIGID FRAME - WRAP
HORIZONTAL PORTION
AND OR PARTS THAT
FORM LEDGES WITH
BIRD NETTING TYP. MET. BLDG. SYS.
STRUCTURAL STEEL
TYP. SEE
STRUCTURAL DWGS
HOT-DIPPED GALV. STEEL STRUC. PAINTED
PRE-FIN. STANDING SEAM METAL
ROOF BY MET. BLDG.
MANUFACTURER WITH
CONTIUOUS BIRD SCREEN
FABRIC APPLIED TO UNDERSIDE
OF PURLINS TYP.
NOTE: HEAVY DASHED LINE DENOTES
AIRCRAFT CLEARANCE ENVELOPE AND
CAN NOT BE VIOLATED
US Army Corps of Engineers ®
SHEET ID
U S
AR
M Y C O R
PS
O F
EN
G
IN
EE
R S
D R
AW
N B Y:
D
ES
IG
N
ED
B Y:
SU
BM
IT
TE
D B Y:
SI
ZE
C H
EC
KE
D B Y:
AN
SI
D
IS
SU
E D
AT
E:
C O N
TR
AC
T N O
SO
LI
C
IT
AT
IO
N N O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K D
ES
C R
IP
TI
O N
P H
IL
IP
S H W Y
SU
IT
E
JA
C
KS
O N
VI
LL
E, F L
TE
L:
-2 -8
A-301
BU
IL
D
IN
G C R O
SS
S
EC
TI
O N
TY
N D
AL
L
AF
B, F L
M O
BI
LE
D
IS
TR
IC
T
ST
J O
SE
PH
S T.
M O
BI
LE
, A L
G M H
IL
L
EN
G
IN
EE
R
IN
G
IN
C
XX
X
YY
Y
Au th or
EA
L
XX
X
YY
Y
J U N E
W 8- -D -0 5/
W 1F
RTA DESIGN SUBMITTAL
FL
IG
H T
LI
N E F- S U N
SH
AD
ES
W
XN
J1
1/4" = 1'-0"1 SINGLE BAY SECTION 0 4'2' 8'
AM
/0 5/
| GENERAL |
| G-001 COVER SHEET |
| G-002 LOCATION AND VICINITY MAP |
| G-003 LAY DOWN AREA AND HAUL ROUTE |
| GEOTECH |
| B-100 BORING LOCATION PLAN |
| CIVIL |
| C-001 PROJECT NOTES, ABBREVIATIONS AND LEGENDS |
| C-100 OVERALL EXISTING CONDITIONS PLAN |
| C-101 EXISTING CONDITIONS PLAN |
| C-102 EXISTING CONDITIONS PLAN |
| C-103 EXISTING CONDITIONS PLAN |
| C-110 DEMOLITION PLAN |
| C-111 DEMOLITION PLAN |
| C-112 DEMOLITION PLAN |
| C-120 OVERALL ENVIRONMENTAL PLAN |
| C-121 ENVIRONMENTAL PLAN |
| C-122 ENVIRONMENTAL PLAN |
| C-123 ENVIRONMENTAL PLAN |
| C-200 OVERALL SITE PLAN |
| C-201 SITE PLAN |
| C-202 SITE PLAN |
| C-203 SITE PLAN |
| C-204 GEOMETRIC CONTROL POINT TABLE |
| C-210 SITE CONSTRUCTION DETAILS |
| C-211 SITE CONSTRUCTION DETAILS |
| C-212 SITE CONSTRUCTION DETAILS |
| C-221 JOINTING AND ELEVATION PLAN |
| C-222 JOINTING AND ELEVATION PLAN |
| C-223 JOINTING AND ELEVATION PLAN |
| C-500 OVERALL EROSION AND SEDIMENT CONTROL PLAN |
| C-501 EROSION AND SEDIMENT CONTROL PLAN |
| C-502 EROSION AND SEDIMENT CONTROL PLAN |
| C-503 EROSION AND SEDIMENT CONTROL PLAN |
| C-510 EROSION AND SEDIMENT CONTROL DETAILS |
| ARCHITECTURAL |
| A-001 GENERAL NOTES, ABBREVIATIONS |
| A-100 ARCHITECTURAL SITE PLAN |
| A-101 TYP OVERALL PLAN SUNSHADES 2 AND 5 |
| A-102 ENLARGED PLAN - 2 BAYS-SS2 |
| A-103 SUNSHADE ROOF PLAN |
| A-104 SUNSHADE REFLECTED CEILING PLAN |
| A-201 ELEVATIONS |
| A-301 BUILDING CROSS SECTION |
| A-302 SITE SECTIONS |
| STRUCTURAL |
| S001 DESIGN CRITERIA AND GENERAL NOTES |
| S002 GENERAL NOTES |
| S100 STRUCTURAL SITE PLAN |
| S101 TYPICAL OVERALL PLAN SUNSHADES 2 AND 5 |
| S102 ENLARGED PLAN 2 BAYS SS2 |
| S103 ENLARGED PLAN 2 BAYS SS5 |
| S301 FOUNDATION SECTIONS AND DETAILS |
| ELECTRICAL |
| E-001 ELECTRICAL LEGEND AND ABBREVIATIONS |
| ES101 ELECTRICAL SITE PLAN |
| ES102 ELECTRICAL SITE PLAN |
| ES103 ELECTRICAL SITE PLAN |
| EG101 LIGHTNING PROTECTION PLAN |
| EG102 AIRCRAFT STATIC GROUNDING PLAN |
| EL101 ELECTRICAL LIGHTING PLANS |
| EL102 ELECTRICAL ROOF LIGHTING PLAN |
| EP101 ELECTRICAL POWER PLANS |
| EP102 ELECTRICAL POWER PLANS |
| E-501 LUMINAIRE SCHEDULE AND LIGHTING PLATES |
| E-502 ELECTRICAL DETAILS |
| E-601 ELECTRICAL RISER DIAGRAMS |
| E-701 PANELBOARD SCHEDULES |
| COVER.pdf |
| INDEX_SHEET_CESAM.pdf |
| Sheets and Views |
| INDEX_SHEET_CESAM-SHEET-ANSI D 22x34 |
| INDEX_SHEET_CESAM.pdf |
| Sheets and Views |
| INDEX_SHEET_CESAM-SHEET-ANSI D 22x34 |
| INDEX_SHEET_CESAM.pdf |
| Sheets and Views |
| INDEX_SHEET_CESAM-SHEET-ANSI D 22x34 |
File details come from the government source that posted it. Updated .