SUNNYSIDE ES__DRAWING SET__4_22_24.pdf
PDF 9 MB Posted
- Attached to
- HVAC & ELECTRICAL UPGRADES
- Solicitation number
- 64841
- Issued by
- Dinwiddie County, Madison Heights CDP, Virginia
About this file
This document is a set of architectural and engineering design drawings and specifications for HVAC and electrical upgrades to Sunnyside Elementary School in Dinwiddie County, Virginia. The project scope includes the removal and replacement of mechanical equipment serving the gymnasium, replacement of corridor ceiling grid and tiles, and installation of electrical infrastructure for future roof-mounted HVAC equipment. The work is planned to be performed during the summer when the building will remain open and operational, with the contractor required to maintain access to walkways, corridors, and other occupied areas. The owner reserves the right to occupy and install equipment in completed portions of the work prior to substantial completion.
The document provides details on the existing building construction, relevant building codes, and hazardous materials assessments. Contractors are required to visit the site, coordinate with the owner, and identify any necessary adjustments based on field conditions. Pricing and funding information are not included, but the contract appears to be a state or local government project for Dinwiddie County Public Schools.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUNNYSIDE ELEMENTARY HVAC & ELECTRICAL UPGRADES
DINWIDDIE COUNTY PUBLIC SCHOOLS
RRMM ARCHITECTS, PC
ARCHITECTURE / PLANNING / INTERIORS
OWNER
MEP ENGINEERING
22 ENTERPRISE PARKWAY, SUITE 200
HAMPTON, VIRGINIA 23666 DINWIDDIE, VA 23841
P: (804) 469-4190 F: (804) 469-4197
1317 Executive Boulevard, Suite 200 Chesapeake, VA 23320
(757) 622-2828
28 Church Avenue SW Roanoke, VA 24011
(540) 344-1212
3700 Koppers Street, Suite 300 Baltimore, MD 21227
(410) 234-8444
2900 South Quincy Street, Suite 710 Arlington, VA 22206
(703) 998-0101
115 South 15th Street, Suite 502 Richmond, VA 23219
(804) 277-8987
P: (804) 469-4190 F: (804) 469-4197
Thompson Consulting Engineers
10203 MELVIN B. ALSBROOKS AVE, MCKENNEY, VA 23872
Dunbar Engineering N/A
VICINITY MAP CONSULTANTS
CIVIL ENGINEER
N/A
SITE
TRUE
NORTH
LOCATION MAP
DINWIDDIE COUNTY PUBLIC SCHOOLS
P.O. BOX 7, 14016 BOYDTON PLANK ROAD
SITE
TRUE
NORTH
BUILDING CODE DESIGN SUPPORTING DATA
APPLICABLE CODES
• VIRGINIA UNIFORM STATEWIDE BUILDING CODE (VUSBC) 2021
• VIRGINIA CONSTRUCTION CODE (VCC) 2021 -VUSBC PART 1
• VIRGINIA EXISTING BUILDING CODE (VEBC) 2021 LEVEL 2-VUSBC PART 2
• VIRGINIA STATEWIDE FIRE PREVENTION CODE (VSFPC) 2021
• NATIONAL FIRE ALARM AND SIGNALING CODE -NFPA 72, 2022
• STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION AND DEMOLITION OPERATIONS - NFPA 241,
• AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE DESIGN, SEPTEMBER 15, 2010
• VIRGINIA PLUMBING CODE, 2021
• VIRGINIA MECHANICAL CODE, 2021
• NATIONAL ELECTRICAL CODE-NFPA 70, 2023
EXISTING BUILDING CLASSIFICATION (PER VEBC)
THE EXISTING BUILDING WAS CONSTRUCTED IN 1981.
BUILDING AREAS
FLOOR BUILDING AREA: 37,416
BUILDING OCCUPANCY AND CONSTRUCTION TYPE
EBC CHAPTER 6 ALTERATIONS
SECTION 601.2.1 - THIS PROJECT IS CLASSIFIED AS A LEVEL 1 ALTERATION SINCE THE ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES USING
NEW MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES THAT SERVE THE SAME PURPOSE
EBC SECTION 503 ALTERATIONS
IBC SECTION 601 TYPES OF CONSTRUCTION
IBC SECTION 803.13 INTERIOR FINISHES
IBC SECTION 1004 OCCUPANT LOAD
THE OCCUPANT LOAD OF THE EXISTING SCHOOL HAS NOT CHANGED DUE TO THE PROPOSED SCOPE OF THIS
PROJECT.
AREA ALLOWANCE PER OCCUPANT (PER VCC TABLE 1004.1.1)
1. ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOMS 300 SF GROSS
3. ASSEMBLY, UNCONCENTRATED TABLES AND CHAIRS 15 SF NET
4. ASSEMBLY, CONCENTRATED 7 SF NET
5. BUSINESS AREAS 100 SF GROSS
6. EDUCATIONAL CLASSROOMS 20 SF NET
IBC SECTION 1005 MEANS OF EGRESS SIZING
THE MINIMUM EGRESS WIDTH HAS NOT CHANGED DUE TO THE SCOPE OF THIS PROJECT.
IBC SECTION 1006 NUMBER OF EXITS AND EXIT DOORWAYS
EXISTING BUILDING USE CLASSIFICATION: GROUP "E" EDUCATIONAL.
PROPOSED BUILDING USE CLASSIFICATION PER VCC 302.1: GROUP "E" EDUCATIONAL.
PER VCC 303.1.3 ASSEMBLY AREAS THAT ARE ACCESSORY TO GROUP E ARE NOT CONSIDERED SEPARATE
OCCUPANCIES.
PER VCC 602.1 CONSTRUCTION TYPE: TYPE IIC, NON-COMBUSTIBLE UNPROTECTED, UNSPRINKLED, WITH FIRE
ALARM.
SECTION 503.1 THE ALTERATIONS PROPOSED IN THIS PROJECT DO NOT MAKE THE EXISTING BUILDING LESS
COMPLIANT WITH THE INTERNATIONAL BUILDING CODE PRIOR TO THE ALTERATION.
TABLE 601 THE NEW WORK PROPOSED IN THIS PROJECT IS COMPLIANT WITH THE EXISTING TYPE IIC
CONSTRUCTION TYPE.
GROUP E
CORRIDORS: CLASS B
ROOMS AND ENCLOSED SPACES: CLASS C
THE NUMBER OF EXITS HAS NOT CHANGED DUE TO THE SCOPE OF THIS PROJECT. THE COMMON PATH OF
TRAVEL HAS NOT CHANGED DUE TO THE SCOPE OF THIS PROJECT.
DISCLOSURE STATEMENTS
ASBESTOS DISCLOSURE STATEMENT
BUILDING WAS CONSTRUCTED BEFORE JANUARY 1, 1985 -
NO HAZARDOUS/ ASBESTOS CONTAINING BUILDING MATERIALS (ACBM) SHALL BE USED ON THIS
PROJECT.
ACBM IS SUSPECTED TO HAVE BEEN USED IN THE ORIGINAL CONSTRUCTION OF THE BUILDING, BASED ON THE SCOPE OF WORK, IT IS NOT ANTICIPATED THAT ACBM'S WILL BE DISTURBED AS A PART OF THIS WORK. REFERENCE AHERA
REINSPECTION REPORT DATED JANUARY 22, 2020 INCLUDED IN THE PROJECT MANUAL.
LEAD DISCLOSURE STATEMENT
DIG NOTICE
RECORD DRAWINGS
EXISTING CONDITIONS ILLUSTRATED HAVE BEEN DETERMINED FROM ORIGINAL CONSTRUCTION
DOCUMENTS AND LIMITED NON-INVASIVE FIELD INVESTIGATION. THE CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR TO SUBMISSION OF BID AND COMMENCEMENT OF WORK TO COORDINATE AND
MAKE ANY NECESSARY ADJUSTMENTS.
IF ANY ADDITIONAL SUSPECTED ACBM MATERIALS ARE DISCOVERED BY THE CONTRACTOR, THE
CONTRACTOR SHALL NOTIFY ARCHITECT/ OWNER IMMEDIATELY. THE ABATEMENT / REMOVAL OF
HAZARDOUS AND/ OR ASBESTOS CONTAINING MATERIALS WILL BE HANDLED UNDER A SEPERATE
CONRACT BY THE OWNER. THE ASBESTOS ABATEMENT CONTRACTOR SHALL MARK UP THE AS-BUILT DRAWINGS RESULTING FROM ITS WORK TO INCLUDE AREAS WHERE ASBESTOS WAS ABATED, AREAS WHERE ASBESTOS WAS ENCAPSULATED, AND AREAS WHERE ACBM EXIST BUT WERE LEFT IN PLACE.
THE ACBM THAT IS TO REMAIN AND THE NEW NON ASBESTOS-CONTAINING MATERIAL SHALL BE
LABELED ACCORDINGLY. THE GENERAL CONTRACTOR SHALL REVIEW AND CERTIFY THE LOCATIONS WHERE ACBM WAS ABATED, AREAS WHERE ACBM WAS ENCAPSULATED AND AREAS WHERE ACBM WAS LEFT IN PLACE AS MARKED ON THE AS-BUILT DRAWINGS AND WILL PROVIDE THE DRAWINGS TO THE
ARCHITECT.
BUILDING WAS CONSTRUCTED BEFORE JANUARY 1, 1985 -
NO HAZARDOUS/ LEAD CONTAINING BUILDING MATERIALS (LCBM) SHALL BE USED ON THIS PROJECT.
NO SUSPECTED LCBM ARE KNOWN TO HAVE BEEN USED IN EXISTING CONSTRUCTION. CONTRACTOR
SHALL NOTIFY ARCHITECT/ OWNER IMMEDIATELY IF ANY SUSPECTED LCBM MATERIALS ARE
DISCOVERED. WHERE SUCH ACTIONS ARE REQUIRED, THE ABATEMENT / REMOVAL OF HAZARDOUS AND/ OR LEAD CONTAINING MATERIALS WILL BE HANDLED UNDER A SEPARATE CONTRACT BY THE OWNER.
THE LEAD ABATEMENT CONTRACTOR SHALL MARK UP THE AS-BUILT DRAWINGS RESULTING FROM ITS WORK TO INCLUDE AREAS WHERE LEAD WAS ABATED, AREAS WHERE LEAD WAS ENCAPSULATED, AND AREAS WHERE LCBM EXIST BUT WERE LEFT IN PLACE. THE LCBM THAT IS TO REMAIN AND THE NEW NON LEAD-CONTAINING MATERIAL SHALL BE LABELED ACCORDINGLY. THE GENERAL CONTRACTOR SHALL
REVIEW AND CERTIFY THE LOCATIONS WHERE LCBM WAS ABATED, AREAS WHERE LCBM WAS
ENCAPSULATED AND AREAS WHERE LCBM WAS LEFT IN PLACE AS MARKED ON THE AS-BUILT DRAWINGS
AND WILL PROVIDE THE DRAWINGS TO THE ARCHITECT.
CONTACT MISS UTILITY AT 811, 1-800-552-7001, OR HTTP://WWW.MISSUTILITYOFVIRGINIA.COM NO LESS THAN 72 HOURS PRIOR TO EXCAVATION AND DO NOT DISTURB THE SOIL UNTIL DIG TICKET HAS BEEN
PROCESSED
ALTHOUGH THE WORK IS TO BE PERFORMED DURING THE SUMMER MONTHS, THE BUILDING & SITE
WILL REMAIN OPEN, OPERATIONAL & ACCESSIBLE TO THE PUBLIC & STAFF DURING REGULAR
BUSINESS HOURS THROUGH THE COURSE OF CONSTRUCTION WORK. ALL MAIN PUBLIC AREAS &
MEANS OF EGRESS PATHWAYS MUST REMAIN CLEAR AND ACCESSIBLE AT ALL TIMES.
REFER TO THE CONSTRUCTION DOCUMENTS FOR ADDITIONAL RESTRICTIONS AND REQUIREMENTS.
UNLESS OTHERWISE NOTED, ALL WORK INDICATED IN THE CONTRACT DOCUMENTS ARE TO BE
INCLUDED IN THE BASE BID.
PARTIAL OWNER OCCUPANCY: OWNER WILL OCCUPY THE PREMISES DURING ENTIRE
CONSTRUCTION PERIOD, WITH THE EXCEPTION OF AREAS UNDER CONSTRUCTION. COOPERATE
WITH OWNER DURING CONSTRUCTION OPERATIONS TO MINIMIZE CONFLICTS AND FACILITATE
OWNER USAGE. PERFORM THE WORK SO AS NOT TO INTERFERE WITH OWNER'S OPERATIONS.
MAINTAIN EXISTING EXITS.
THIS WORK INCLUDES (BUT IS NOT LIMITED TO) THE
FOLLOWING RESTRICTIONS AND REQUIREMENTS:
BUILDING CODE DESIGN SUPPORTING DATA CONT.
IBC SECTION 2902 MINIMUM PLUMBING FACILITIES
THE NUMBER OF PLUMBING FIXTURES HAS NOT CHANGED DUE TO THE SCOPE OF THIS PROJECT.
PROJECT SCOPE IS GENERALLY DESCRIBED AS THE REMOVAL/REPLACEMENT OF MECHANICAL EQUIPMENT SERVICING THE GYMNASIUM, REMOVAL/REPLACEMENT OF CORRIDOR CEILING GRID AND ACOUSTICAL CEILING TILE AND INSTALLATION OF ELECTRICAL PANELS AND INFRASTRUCTURE (I.E. CONDUIT) FOR FUTURE ELECTRICAL CONNECTION TO ROOFTOP MECHANICAL EQUIPMENT AS NOTED WITHIN THE CONSTRUCTION DOCUMENTS FOR SUNNSIDE ELEMENTARY SCHOOL - HVAC & ELECTRICAL
UPGRADES.
PROJECT SUMMARY
1. MAINTAIN ACCESS TO EXISTING WALKWAYS, CORRIDORS, AND OTHER ADJACENT
OCCUPIED OR USED FACILITIES. DO NOT CLOSE OR OBSTRUCT WALKWAYS,
CORRIDORS, OR OTHER OCCUPIED OR USED FACILITIES WITHOUT WRITTEN
PERMISSION FROM OWNER AND AUTHORITIES HAVING JURISDICTION.
2. PROVIDE NOT LESS THAN SEVENTY-TWO (72) HOURS' NOTICE TO OWNER OF
ACTIVITIES THAT WILL AFFECT OWNER'S OPERATIONS, INCLUDING BUT NOT LIMITED
TO, BUILDING SYSTEMS (HVAC, PLUMBING, ELECTRICITY AND IT SYSTEMS). OWNER
LIMITED OCCUPANCY OF COMPLETED AREAS OF CONSTRUCTION:
3. THE OWNER RESERVES THE RIGHT TO OCCUPY AND TO PLACE AND INSTALL
EQUIPMENT IN COMPLETED PORTIONS OF THE WORK, PRIOR TO SUBSTANTIAL
COMPLETION OF THE WORK, PROVIDED SUCH OCCUPANCY DOES NOT INTERFERE
WITH COMPLETION OF THE WORK. SUCH PLACEMENT OF EQUIPMENT AND LIMITED
OCCUPANCY SHALL NOT CONSTITUTE ACCEPTANCE OF THE TOTAL WORK.
A. ARCHITECT WILL PREPARE A CERTIFICATE OF SUBSTANTIAL COMPLETION FOR
EACH PHASE OF THE WORK TO BE OCCUPIED PRIOR TO OWNER ACCEPTANCE OF THE
COMPLETED WORK.
B. OBTAIN A CERTIFICATE OF OCCUPANCY FROM AUTHORITIES HAVING
JURISDICTION BEFORE LIMITED OWNER OCCUPANCY.
C. BEFORE LIMITED OWNER OCCUPANCY, SPRINKLER, FIRE ALARM, MECHANICAL
AND ELECTRICAL SYSTEMS SHALL BE FULLY OPERATIONAL, AND REQUIRED TESTS
AND INSPECTIONS SHALL BE SUCCESSFULLY PERFORMED AND APPROVED BY THE
AUTHORITIES HAVING JURISDICTION. ON OCCUPANCY, OWNER WILL OPERATE AND
MAINTAIN THE FIRE ALARM, MECHANICAL AND ELECTRICAL SYSTEMS SERVING
OCCUPIED PORTIONS OF WORK.
4. UPON OCCUPANCY, OWNER WILL ASSUME RESPONSIBILITY FOR MAINTENANCE AND
CUSTODIAL SERVICE FOR OCCUPIED PORTIONS OF WORK.
COORDINATION WITH OCCUPANTS
3/
/2
2:
:4
PM
BI
M
5-
D in w id di e C ou nt y Pu bl ic
S ch oo ls
/2
-0 v2
D
C
PS
S ou th si de E
S
- A
R C
H .rv t
G-001
TI
TL
E
SH
EE
T
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
H
VA
C
E
LE
C
TR
IC
AL
U
PG
R
AD
ES
D
IN
W
ID
D
IE
C
O U
N
TY
P U
BL
IC
S C
H O
O
LS
M
EL
VI
N B
. A
LS
BR
O
O
KS
A
VE
, M C
KE
N
N Y, V A
MECHANICAL
M-001 GENERAL NOTES, LEGEND, ABBREVIATIONS AND DIAGRAMS
M-002 MECHANICAL SCHEDULES
M-003 VENTILATION CALCULATIONS
MD-101 AREA A FLOOR PLAN - MECHANICAL - DEMOLITION
MD-102 ROOF PLAN - MECHANICAL - DEMOLITION
M-101 AREA A FLOOR PLAN - MECHANICAL - NEW WORK
M-102 ROOF PLAN - MECHANICAL - NEW WORK
M-201 MECHANICAL DETAILS
M-202 FRAMING CLAMP SYSTEM DETAILS
M-301 AUTOMATIC TEMPERATURE CONTROLS
ELECTRICAL
E-001 ELECTRICAL LEGEND, NOTES, AND ABBREVIATIONS
AREA A FLOOR PLAN - ELECTRICAL - DEMOLITIONED-101
ED-102
E-101 E-102
ROOF PLAN - ELECTRICAL - NEW WORK
E-201 PANELBOARD SCHEDULES AND POWER RISER DIAGRAM
SHEET INDEX
SHEET NUMBER SHEET TITLE
PROJECT TITLE SHEET
G-001 TITLE SHEET
ARCHITECTURAL DEMO
AD-101 REFLECTED CEILING PLAN - DEMOLITION
ARCHITECTURAL
A-001 ARCHITECTURAL GENERAL INFORMATION
A-101 REFLECTED CEILING PLAN - NEW WORK
/22
/20
5-
05 MP JA
HAA
Lic. No. 10748
JEFFREY A HARRIS
T
T E CIHCR
A
C
T
O M M
ON
WE
A L FOH
A N I
G I
RI
V
RRMM
ARCHITECTS, PC
DA
TE
DR
AW
N
PR
OJ
EC
T
DE
SI
GN
ED
CH
EC
KE
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
MA
RK
RE
VI
SI
ON
SDA
TE
BY
DE
SC
RI
PT
IO
N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
OJ
EC
T
DR
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
E-103
ROOF PLAN - ELECTRICAL - DEMOLITION
AREA A FLOOR PLAN - ELECTRICAL - NEW WORK
AREA B FLOOR PLAN - ELECTRICAL - NEW WORK
4/22/24
121212121212121212121212121212121212
1.
2.
3.
4.
6.PROVIDE FLOOR-TO-CEILING TEMPORARY DUST PARTITIONS TO CONTAIN
DUST FROM DEMOLITION OPERATIONS FROM THE REMAINDER OF THE
BUILDING. PARTITION SHALL BE CONSTRUCTED OF
PLASTIC SHEETING W/ LAPPED & TAPED JOINTS FOR DUST PROTECTION.
COORDINATE DEMOLITION WORK W/ NEW WORK NOTES TO ENSURE PROPER
REMOVAL OF ITEMS.
REFER TO SPECIFICATION SECTION 024119 SELECTIVE DEMOLITION FOR
FURTHER INFORMATION ON REMOVAL & DISPOSAL.
ANY DIMENSIONS SHOWN FOR EXISTING CONSTRUCTION ARE APPROXIMATE:
FIELD VERIFY ALL DIMENSIONS.
ALL DEMOLITION WORK NOTED ON THESE DRAWINGS INVOLVES THE
REMOVAL OF EXISTING CONSTRUCTION UNDER THE BASE CONTRACT, &
SHALL BE COORDINATED W/ CORRESPONDING NEW WORK FLOOR PLANS &
DETAILS. REMOVE EXISTING CONSTRUCTION AS INDICATED FOR FINISH
CONSTRUCTION & NEW WORK TO CONFORM TO DETAILS.
GENERAL DEMOLITION NOTES
7.
8.
9.
10.
DETAILS OF EXISTING CONDITIONS: ACTUAL FIELD CONDITIONS WHICH ARE
CONCEALED BY EXISTING CONSTRUCTION MAY VARY SOMEWHAT FROM
THOSE INDICATED IN DRAWINGS. ALL WORK THAT RELATES TO, OR IS IN ANY
WAY AFFECTED BY, EXISTING CONDITIONS WHICH VARY FROM THOSE
INDICATED SHALL BE MODIFIED AS REQUIRED BY FIELD CONDITIONS &
MEASUREMENTS. REPORT DISCREPANCIES TO ARCHITECT BEFORE
PROCEEDING W/ AFFECTED ASPECTS OF CONSTRUCTION OR DEMOLITION.
PORTIONS OR ELEMENTS OF CEILING SCHEDULED TO BE REMOVED SHALL
BE DONE SO TO PREVENT DAMAGE TO ADJACENT CONSTRUCTION TO
REMAIN.
11.
12.
13.
15.
ITEMS IDENTIFIED TO BE SALVAGED ("REMOVE & DELIVER TO OWNER") SHALL
BE CAREFULLY REMOVED & DELIVERED TO A STORAGE AREA DESIGNATED
BY THE OWNER FOR THIS PURPOSE. ITEMS OWNER CHOOSES TO RETAIN
SHALL BE RELOCATED FROM THE STORAGE AREA BY OWNER (NIC). ALL
OTHER ITEMS SHALL BE SUBSEQUENTLY REMOVED & DISPOSED OF BY
CONTRACTOR WHEN AUTHORIZED BY OWNER.
EXISTING LOOSE FURNITURE, EQUIPMENT, SUPPLIES, & PERSONAL
BELONGINGS LOCATED IN SPACES TO BE RENOVATED SHALL BE REMOVED &
RELOCATED BY OWNER (NIC).
PREPARE CEILINGS FOR NEW FINISHES AS SCHEDULED, IN ACCORDANCE W/
MANUF RECOMMENDATIONS FOR SURFACES SHALL BE SCRAPED, CLEANED, &
REPAIRED AS REQ'D TO PROVIDE A CLEAN MONOLITHIC SURFACE READY TO
RECEIVE FINISHES.
CONTRACTOR SHALL FIELD VERIFY & COORDINATE ALL CEILING MOUNTED
ITEMS WITH THE NEW ARCHITECTURAL, MECHANICAL &
ELECTRICAL REFLECTED CEILING PLAN DRAWINGS.
REFER TO MECHANICAL & ELECTRICAL DRAWINGS FOR
ADDITIONAL ABOVE CEILING WORK THAT MAY BE REQUIRED. ALL EXISTING
MATERIALS TO REMAIN WHICH ARE DAMAGED OR OTHERWISE DISTURBED BY
THE CONTRACTORS OPERATIONS ARE TO BE PATCHED & REPAIRED TO
MATCH EXISTING, AT NO ADDITIONAL COST TO THE OWNER.
REMOVE ALL EXISTING CEILING MOUNTED DEVICES IN THIS AREA, STOW
WIRING/CABLING ABOVE CEILING FOR REUSE & IDENTIFY. MARK AREA FOR
DEVICE TO BE REINSTALLED. ONCE THE RENOVATION OF THE CEILINGS
HAVE BEEN COMPLETED, CLEAN AND REINSTALL DEVICES & RECONNECT TO
PREVIOUS STOWED CABLES.
REMOVE CEILING SYSTEM AND ASSOCIATED SUBSTRUCTURE COMPLETE. COORDINATE W/ MECH, ELEC
DEMOLITION DWGS
KEY NOTES - DEMOLITIONX APPLIES TO AD SHEETS
REMOVE AND STORE ALL EXISTING-TO-REMAIN CEILING MOUNTED EQUIPMENT (I.E. LIGHT FIXTURES, HVAC DIFFUSERS, RETURN GRILLES, ETC.) FOR RE-INSTALLATION IN NEW CEILING GRID SYSTEM SHOWN
ON SHEET A-101.
Lic. No. 10748
JEFFREY A HARRIS
T
T E CIHCR
A
C
T
O M M
ON
WE
A L FOH
A N I
G I
RI
V
RRMM
ARCHITECTS, PC
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
3/
/2
2:
:5
PM
BI
M
5-
D in w id di e C ou nt y Pu bl ic
S ch oo ls
/2
-0 v2
D
C
PS
S ou th si de E
S
- A
R C
H .rv t
AD-101
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
D
EM
O
LI
TI
O N
SCALE: 1/8" = 1'-0"
REFLECTED CEILING DEMOLITION PLAN
TRUE
NORTH
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
H
VA
C
E
LE
C
TR
IC
AL
U
PG
R
AD
ES
D
IN
W
ID
D
IE
C
O U
N
TY
P U
BL
IC
S C
H O
O
LS
M
EL
VI
N B
. A
LS
BR
O
O
KS
A
VE
, M C
KE
N
N Y, V A
/2
2/
5- 05 M P
JA
HAA
CONTINUOUS WOOD BLOCKING
CONCRETE MASONRY UNIT
CAST-IN-PLACE CONCRETE
STEEL
EARTH / COMPACT FILL
BATT INSULATION
POROUS FILL / GRAVEL
RIGID INSULATION
GYPSUM BOARD
RESILIENT FLOORING /
PLASTIC LAMINATE
ALUMINUM
FINISHED WOOD
WOOD BLOCKING
BRICK
GLASS
ACOUSTICAL TILE
PLYWOOD
CERAMIC TILE - LARGE SCALE
SAND / MORTAR / PLASTER
GRAVEL
ARCHITECTURAL MATERIAL LEGEND
TOILET ACCESSORIES
DOOR TAG -
BUILDING DIV/DOOR NUMBER
LOCATION SUFFIX (IF REQ'D)
XX WINDOW TYPE
EXTERIOR / INTERIOR / INTERIOR CASEWORK
ELEVATION IDENTIFICATION NUMBER
SF
XX
WINDOW FRAME TYPES
(REF A600 SERIES DRAWINGS)
STOREFRONTXX
XX
SIGNAGE TYPE
SIGNAGE NO. ARCH NO.
ROOM NAME
BLDG DIV / CONST NO.
SECTION NUMBER
BUILDING SECTION REFERENCE
DRAWING NUMBER WHERE SECTION IS DRAWN
SECTION NUMBER
SECTION REFERENCE
DRAWING NUMBER WHERE SECTION IS DRAWN
PLAN OR DETAIL NUMBER
ENLARGED PLAN OR DETAIL REFERENCE
DRAWING NUMBER WHERE ENLARGED PLAN OR
DETAIL IS DRAWN
MSR8 PARTITION TYPE (SEE PARTITION
LEGEND)
LOUVER TYPELX
AXXX
X
SHEET NUMBER WHERE ELEVATION
IS LOCATED
CW
XX
HM
XX
HOLLOW METAL FRAME TYPES
(REF A600 SERIES DRAWINGS)
HOLLOW METAL FRAME
CURTAIN WALL TYPES
(REF A600 SERIES DRAWINGS)
CURTAIN WALL
SCALE:
A1 TITLE
A-101 R1011/8" = 1'-0"
DRAWING TITLE
MAIN DRAWING TITLE
DRAWING SCALE
DRAWING TITLE
DRAWING TITLE WITH REFERENCE SYMBOL
DRAWING REFERENCE NUMBER
A-101
A1
CONTROL JOINT
DRAWING SHEET NUMBER
DRAWING NUMBER DESIGNATION
ELEVATION REFERENCE
ARCHITECTURAL GRAPHIC SYMBOLS
DRAWING SCALE
SCALE:
TITLE
1/8" = 1'-0"
X
ROOM
A101
A-101 A1
X
A1
A
MATCH LINE
SEE 1 A101
C1 A-101
C1 A-101
C1 A-101
X NEW WORK KEY NOTE
DEMOLITION KEY NOTE1
3/
/2
2:
:5
PM
BI
M
5-
D in w id di e C ou nt y Pu bl ic
S ch oo ls
/2
-0 v2
D
C
PS
S ou th si de E
S
- A
R C
H .rv t
A-001
AR
C
H
IT
EC
TU
R
AL
G
EN
ER
AL
IN
FO
R M
AT
IO
N
V VOLT, VALLEY
VAC VACUUM
VAR VARNISH
VB VENTED BASE
VCT VINYL COMPOSITION TILE
VEN VENEER
VERT VERTICAL
VEST VESTIBULE
VR VAPOR RETARDER
VT VINYL TILE
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WEST, WIDE, WIDTH
W/ WITH
W/O WITHOUT
WAIN WAINSCOT
WB WOOD BASE
WC WATER CLOSET
WD WOOD / WOOD FLOORING
WDB WOOD BASE
WDW WINDOW
WGL WIRE GLASS
WH WATER HEATER
WI WROUGHT IRON
WMS WIRE MANAGEMENT SLOT
WP WATERPROOFING
WPT WORKING POINT
WR WASTE RECEPTACLE
WT WEIGHT
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
PR PAIR
PREFAB PREFABRICATE, PREFABRICATED
PREFIN PRE-FINISHED
PRJ SC PROJECTION SCREEN
PRT PORCELAIN TILE
PS PENCIL SHARPENER
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PTD PAINTED
PTN PARTITION
PVC POLYVINYL CHLORIDE / PVC EDGE BAND
PVMT PAVEMENT
QT QUARRY TILE
QTY QUANTITY
R RISER, RIDGE
R/W RIGHT OF WAY
RA RETURN AIR
RAD RADIUS
RAS RESILIENT ATHLETIC SURFACING
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RECP RECEPTACLE
REF REFERENCE
REFRIG REFRIGERATOR
REINF REINFORCE, REINFORCED,
REINFORCING
REM REMOVE
REQD REQUIRED
REQMT REQUIREMENT
RESIL RESILIENT
RET RETURN
REV REVISION, REVISIONS, REVISED
RFG ROOFING
RFL REFLECT, REFLECTED, REFLECTIVE
RH RIGHT HAND
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
RSHT RESILIENT SHEET
RT RUBBER TILE / RUBBER TREAD
RTU ROOF TOP UNIT
S SOUTH
S/S STAINLESS STEEL, SERVICE SINK
SAB SOUND ATTENUATION BLANKET
SAN SANITARY SEWER
SAPC SUSPENDED ACOUSTIC PANEL CEILING
SC SOLID CORE, SEALED CONCRETE
SCHED SCHEDULE
SCW SOLID CORE WOOD
SD SOAP DISPENSER, STORM DRAIN
SEC SECTION
SF SQUARE FEET
SFGL SAFETY GLASS
SHLVG SHELVING
SHM SECURITY HOLLOW METAL
SHT SHEET
SHTH SHEATHING
SIM SIMILAR
SLR SEALER
SN STAGE NOSE
SND SANITARY NAPKIN DISPOSER
SOF SPRAY-ON FIREPROOFING
SPEC SPECIFICATION, SPECIFICATIONS
SPK SPEAKER
SQ SQUARE
SS SOLID SURFACE
ST STAIN, STONE
STC SOUND TRANSMISSION CLASS
STD STANDARD
STFT STOREFRONT
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
SUB SUBSTITUTE
SUSP SUSPENDED
SYM SYMMETRICAL, SYMMETRY
SYN SYNTHETIC
SYS SYSTEM
T TREAD
T&B TOP & BOTTOM
TB TACK BOARD
TEL TELEPHONE
TEMP TEMPORARY, TEMPERED
TERR TERRAZZO
TG TONGUE & GROVE
THK THICK, THICKNESS
THRES THRESHOLD
THRU THROUGH
TO TOP OF
TOC TOP OF CURB
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TP TOILET PARTITION
TPT TEXTURED PAINT
TRTD TREATED
TSC TEACHERS STORAGE CABINET
TTD TOILET TISSUE DISPENSER
TV TELEVISION
TW TEACHERS WARDROBE
TYP TYPICAL
UC UNDERCUT
UG UNDER GROUND
UH UNIT HEATER
UNF UNFINISHED
UON UNLESS OTHERWISE NOTED
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
HW HOT WATER
HWH HOT WATER HEATER
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE, INCLUDED, INCLUDING
INFO INFORMATION
INST INSTALLATION
INSUL INSULATE, INSULATED, INSULATION
INT INTERIOR
INTRLK INTERLOCK
INV INVERT
JAN JANITOR
JB JUNCTION BOX
JC JANITOR CLOSET
JCT JUNCTION
JST JOIST
JT JOINT
KIT KITCHEN
KO KNOCKOUT
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
L LENGTH, LONG, LOW
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LB POUND
LCBM LEAD CONTAINING BUILDING MATERIAL
LF LINEAR FEET
LG LAMINATED GLASS
LH LEFT HAND
LIN LINEAR
LK LOCKER
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LP LOW POINT
LTG LIGHTING
LTL LINTEL
LVR LOUVER
LW LIGHTWEIGHT
M METER
M/S MOP SINK
MACH MACHINE
MAINT MAINTENANCE
MANUF MANUFACTURE, MANUFACTURER
MAR MARBLE
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB MARKERBOARD
MBR MODIFIED BITUMEN ROOF
MECH MECHANIC, MECHANICAL
MED MEDIUM
MEMB MEMBRANE
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLD MOLDING
MM MILLIMETER
MO MASONRY OPENING
MOD MODIFIED
MOV MOVABLE
MR MAP RAIL
MT MOUNT
MTD MOUNTED, MOUNTING
MTL METAL
MULL MULLION
MWP MEMBRANE WATERPROOFING
N NORTH
N/C NO CHARGE
NAT NATURAL
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OA OVERALL
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OF/CI OWNER FURNISHED / CONTRACTOR
INSTALLED
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
P PLATE
PAR PARALLEL
PART PARTIAL
PC PRE-CAST, PIECE
PED PEDESTAL
PERF PERFORATE (D)
PERM PERIMETER
PIP POURED IN PLACE
PL PROPERTY LINE / PLASTIC LAMINATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLUMB PLUMBING
PLYWD PLYWOOD
PNL PANEL
POLY POLYURETHANE
PORT PORCELAIN TILE
PORTB PORCELAIN TILE BASE
PPT PRESERVATIVE PRESSURE TREATED
DIM DIMENSION
DISP DISPOSAL
DIV DIVISION
DL DEAD LOAD
DMT DEMOUNTABLE
DN DOWN
DPG DAMPPROOFING
DPR DISPENSER
DR DOOR, DISPLAY RAIL
DS DOWNSPOUT
DWG DRAWING
DWR DRAWER
E EAST
EA EACH
EF EXHAUST FAN
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
ELAS ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATION, ELEVATOR
EM ENTRANCE MAT
EMER EMERGENCY
ENCL ENCLOSE, ENCLOSURE
EP ELECTRICAL PANELBOARD
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPS EXPANDED POLYSTYRENE
EPX EPOXY
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXCA EXCAVATE
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED / EXPANSION
EXP C EXPANSION CONSTRUCTION
EXT EXTERIOR
FAB FABRICATE
FAS FASTEN, FASTENER
FB FACE BRICK
FCVD FLASH COVED
FD FLOOR DRAIN, FIRE DAMPER
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FEJ FLOOR EXPANSION JOINT
FF FINISH FLOOR
FFE FINISH FLOOR ELEVATION
FG FIBER REINFORCED GYPSUM BOARD
FGL FIBERGLASS
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH, FINISHED
FIX FIXTURE
FLEX FLEXIBLE
FLR FLOOR
FLSHG FLASHING
FLUOR FLUORESCENT
FLUR FLUORESCENT
FND FEMININE NAPKIN DISPENSER
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FOS FACE OF STUDS
FP FIREPROOF
FPL FIREPLACE
FR FIRE RATED
FRG (GLASS) FIBER REINFORCED GYPSUM
FRM FRAME, FRAMED
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FT FOOT, FEET
FTG FOOTING
FUM FUME HOOD
FUR FURRED, FURRING
FURN FURNITURE
FURR FURRING
G GAS
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACT, CONTRACTOR
GCMU GLAZED FIBER REINFORCED CONCRETE
GEN GENERAL
GFRC GLASS FIBER REINFORCED CONCRETE
GL GLASS, GLAZING
GPM GALLONS PER MINUTE
GR GRADE / GROUT
GSU GLAZED STRUCTURAL UNIT
GWB GYPSUM WALLBOARD
GWT GLAZED WALL TILE
GYP GYPSUM
H HIGH
H/C HANDICAPPED
HB HOSE BIB
HC HOLLOW CORE
HD HAND
HDBD HARDBOARD
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HR HOUR
HTG HEATING
# NUMBER
&, + AND
+/- PLUS OR MINUS
@ AT
° DEGREES
Ø DIAMETER
Ω ARC LENGTH
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABV ABOVE
ACBM ASBESTOS CONTAINING BUILDING
MATERIAL
ACP ACOUSTIC CEILING PANEL
ACT ACOUSTIC CEILING TILE
ADDN ADDITION
ADH ADHESIVE
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AGG AGGREGATE
AHU AIR HANDLING UNIT
AL ALUMINUM
ALT ALTERNATE
AMP, A AMPERE
ANCH ANCHOR, ANCHORAGE
ANOD ANODIZED
AP ACCESS POINT
APC ARCHITECTURAL PRECAST CONCRETE
APPROX APPROXIMATE
AR ABUSE RESISTANT
ARCH ARCHITECT, ARCHITECTURAL
ASB ASBESTOS
ASPH ASPHALT
ATTEN ATTENUATION
AUTO AUTOMATIC
AVG AVERAGE
AWP ACOUSTIC WALL PANEL
BC BOTTOM OF CURB
BD BOARD
BEJ BUILDING EXPANSION JOINT
BETW BETWEEN
BIT BITUMINOUS
BL BLEACHER FINISH
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BO BOTTOM OF
BOT, B BOTTOM
BRG BEARING
BRK BRICK
BS BOTH SIDES
BSMT BASEMENT
BTWN, B/W BETWEEN
BUR BUILT-UP ROOFING
BVL BEVELED
C CARPET
CAB CABINET
CAP CAPACITY
CB CHALKBOARD
CC CUBICAL CURTAIN
CCTV CLOSED CIRCUIT TELEVISION
CEM CEMENT
CEM TOP CEMENT TOPPING
CER CERAMIC
CF CUBIC FOOT
CFLSHG COUNTER FLASHING
CFM CUBIC FEET PER MINUTE
CG CORNER GUARD
CHAM CHAMFER
CI CAST IRON
CIP CAST IN PLACE
CIR CIRCLE
CJ CONTROL JOINT
CK CAULK, CAULKING
CLG CEILING
CLO CLOSET
CLR CLEAR
CM CENTIMETER, CENTIMETERS
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEAN OUT
COL COLUMN
COMM COMMUNICATION
COMP COMPOSITE
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT, CONTRACTOR
CORR CORRUGATED
CPT CARPET
CRS COURSE. COURSES
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CU FT CUBIC FEET
CU YD CUBIC YARD
CUH CABINET UNIT HEATER
CW COLD WATER
CWFP CEMENTITIOUS WOOD FIBER PANELS
D DEEP, DEPTH, DRAIN
DBL DOUBLE
DEMO DEMOLITION
DET / DTL DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DIA DIAMETER
DIAG DIAGONAL
ABBREVIATIONS
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
H
VA
C
E
LE
C
TR
IC
AL
U
PG
R
AD
ES
D
IN
W
ID
D
IE
C
O U
N
TY
P U
BL
IC
S C
H O
O
LS
M
EL
VI
N B
. A
LS
BR
O
O
KS
A
VE
, M C
KE
N
N Y, V A
/2
2/
5- 05 M P
JA
H
AA
Lic. No. 10748
JEFFREY A HARRIS
T
T E CIHCR
A
C
T
O M M
ON
WE
A L FOH
A N I
G I
RI
V
RRMM
ARCHITECTS, PC
DA
TE
DR
AW
N
PR
OJ
EC
T
DE
SI
GN
ED
CH
EC
KE
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
MA
RK
RE
VI
SI
ON
SDA
TE
BY
DE
SC
RI
PT
IO
N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
OJ
EC
T
DR
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
2 1
NEW CEILING SYSTEM AS SCHEDULED, COORDINATE W/ MECH, ELEC, PLUMB DWGS.
REINSTALL ALL EXISTING-TO-REMAIN CEILING MOUNTED EQUIPMENT (I.E. LIGHT
FIXTURES, HVAC DIFFUSERS, RETURN GRILLES, ETC,) IN NEW CEILING GRID SYSTEM.
KEY NOTES - NEW WORK_
1.
2.
3.
4.
5.THE GENERAL CONTRACTOR SHALL COORDINATE THE WORK OF ALL
TRADES. EXAMINE ALL PLUMBING, MECHANICAL, AND ELECTRICAL
DOCUMENTS. MUCH OF THE INFORMATION IS NOT REPEATED OR SHOWN IN
THE ARCHITECTURAL DOCUMENTS.
THE GENERAL CONTRACTOR SHALL VERIFY LOCATIONS AND EXTENT OF
INSERTS, ANCHORS, PENETRATIONS, ETC, REQUIRED BY PLUMBING,
MECHANICAL AND ELECTRICAL TRADES.
EXISTING CONSTRUCTION SHOWN HALFTONE FOR CLARITY-TYP UON.
CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT
OF ANY DISCREPANCIES OR DETERMINATION OF DIMENSIONAL
ADJUSTMENTS.
PENETRATIONS THROUGH FIRE RATED CONDITIONS SHALL BE
CONSTRUCTED AND SEALED AS REQUIRED TO MAINTAIN THE INTEGRITY OF
THE FIRE RATED ASSEMBLY. PIPES, CONDUITS, DUCTS, STRUCTURAL
MEMBERS, OR OTHER CONSTRUCTION SHALL BE FIRESTOPPED.
FIRESTOPPING SHALL BE PERFORMED USING MATERIALS COMPLYING WITH
THE BUILDING CODES AND STANDARDS APPLICABLE TO THIS PRODUCT AS
INTERPRETED BY THE BUILDING OFFICIAL(S) HAVING JURISDICTION.
GENERAL NOTES
6.
7.
ALL MODIFICATIONS TO THE EXISTING ONE-HOUR CORRIDOR PARTITIONS
SHALL MAINTAIN A ONE HOUR RATING. THE TOP OF THE PARTITIONS MUST
BE SEALED TO THE STRUCTURE ABOVE TO MAINTAIN THE ONE HOUR RATING.
PROTECT AND MAINTAIN INTEGRITY OF ALL INSTALLED EQUIPMENT AND
ROOF SYSTEMS DURING THE ENTIRE DURATION OF CONSTRUCTION.
Lic. No. 10748
JEFFREY A HARRIS
T
T E CIHCR
A
C
T
O M M
ON
WE
A L FOH
A N I
G I
RI
V
RRMM
ARCHITECTS, PC
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15th Street, Suite 502 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
Copyright © 2020 RRMM Architects, PC
3/
/2
2:
:2
PM
BI
M
5-
D in w id di e C ou nt y Pu bl ic
S ch oo ls
/2
-0 v2
D
C
PS
S ou th si de E
S
- A
R C
H .rv t
A-101
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
N
EW
W
O R
K
SO
U
TH
SI
D E
EL
EM
EN
TA
R Y
SC
H
O O
L R
EN
O
VA
TI
O N
D
IN
W
ID
D
IE
C O
U N
TY
P
U
BL
IC
S
C H
O O
LS
BO
YD
TO
N P
LA
N
K R
D , D
IN
W
ID
D
IE
, V
A
SCALE: 1/8" = 1'-0"
REFLECTED CEILING - NEW WORK PLAN
TRUE
NORTH
/2
2/
5- 05 M P
JA
H
AA
RRMM
ARCHITECTS, PC
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
D
IN
W
ID
D
IE
C O
U N
TY
P
U
BL
IC
S
C H
O O
LS
5-
/2
2/
C O
X
RO
A D
Co ns ul tin g En gi ne er s
TH
O
M
PS
O N
E
N
TE
RP
RI
SE
P
A
RK
W A
Y G
LE
N
A
LL
EN
, V
A
H A
M
PT
O N
, V A
S . L
YN
N
H A
VE
N
R O
A D
VA
B
EA
CH
, V A
TE
LE
PH
O N
E:
(7
) 5
-4
PR
O
JE
CT
N U
M
BE
R:
2-
2.
04.22.2024
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
SC
H
O O
L
- H
VA
C
EL
EC
TR
IC
AL
U
PG
R
AD
ES
M-001
BD
C
SL
S
G
EN
ER
AL
N O
TE
S, L
EG
EN
D
, A
BB
R
EV
IA
TI
O N
S, A
N D
D
IA
G R
AM
S
1. WHERE EQUIPMENT IS INDICATED TO BE REMOVED, IT SHALL MEAN COMPLETE REMOVAL
OF EQUIPMENT, INCLUDING CURBS, SUPPORTS, BRACKETS, CONTROLS AND INCIDENTAL
ITEMS CONNECTED OR FASTENED TO EQUIPMENT. OWNER MAINTAINS THE OWNERSHIP
OF ALL ITEMS TAGGED OR IDENTIFIED.
2. WHERE PIPING IS INDICATED TO BE REMOVED, IT SHALL MEAN COMPLETE REMOVAL OF
PIPING, INCLUDING VALVES, FITTINGS, INSULATION, SUPPORTS, HANGERS, BRACKETS,
CONTROLS AND INCIDENTAL ITEMS CONNECTED OR FASTENED TO THE PIPING. PIPING IS
DIAGRAMMATIC AND INDICATES THE GENERAL EXTENT OF WORK. NO ATTEMPT IS MADE
TO SHOW EVERY ELL, TEE, OFFSET, FITTING AND VALVE. REMOVE PIPING AS INDICATED
AND SPECIFIED.
3. WHERE DUCTWORK IS INDICATED TO BE REMOVED, IT SHALL MEAN COMPLETE REMOVAL
OF DUCTWORK, INCLUDING FITTINGS, INSULATION, SUPPORTS, BRACKETS, CONTROLS
AND INCIDENTAL ITEMS CONNECTED OR FASTENED TO THE DUCTWORK. DUCTWORK IS
DIAGRAMMATIC AND INDICATES THE GENERAL EXTENT OF WORK. NO ATTEMPT IS MADE
TO SHOW EVERY ELL, TEE, OFFSET AND FITTING. REMOVE DUCTWORK AS INDICATED
AND SPECIFIED.
4. CONTRACTOR SHALL RECLAIM AND DISPOSE OF ALL REFRIGERANT IN ACCORDANCE
WITH ALL STATE AND LOCAL CODES PRIOR TO REMOVING THE EXISTING UNIT.
GENERAL DEMOLITION NOTES
1. CONTRACTOR SHALL VISIT JOB SITE TO DETERMINE EXTENT OF WORK INVOLVED PRIOR
TO BIDDING THE PROJECT.
2. THE MECHANICAL SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH THE 2018
VIRGINIA UNIFORM STATEWIDE BUILDING CODE.
3. COORDINATE LOCATION OF ALL DUCTWORK, SUPPLY AND RETURN DEVICES,
THERMOSTATS AND OTHER WALL OR CEILING MOUNTED EQUIPMENT WITH OTHER
TRADES SO AS TO PRESENT A NEAT AND ATTRACTIVE INSTALLATION THROUGHOUT THE
BUILDING.
4. ALL PIPING, VALVES, DUCTWORK, ETC., SHALL BE CONCEALED UNLESS OTHERWISE
NOTED.
5. PIPING ARRANGEMENTS ARE DIAGRAMMATIC.
6. PIPING PASSING THROUGH WATERPROOF MEMBRANES SHALL BE MADE WATERTIGHT.
7. ARRANGE PIPING AND DUCTWORK PARTICULARLY ABOVE CEILING AS REQUIRED TO
CLEAR STRUCTURE, CONDUIT, LIGHTS, ETC., ALLOWING SPACE FOR HANGERS,
INSULATION, ETC.
8. DUCT DIMENSIONS MAY BE MODIFIED AS APPROVED BY ENGINEER.
9. DUCT SIZES SHOWN ARE INSIDE FREE AREA DIMENSIONS.
10. MAINTAIN PROPER CLEARANCES PER ELECTRICAL CODE ON ALL EQUIPMENT.
COORDINATE WITH ALL TRADES TO ENSURE CLEARANCES ARE NOT OBSTRUCTED.
11. INSTALL ALL WALL MOUNTED NON-ADJUSTABLE SENSORS AT 5'-0" FROM FINISHED
FLOOR TO TOP OF SENSOR. ADJUSTABLE DEVICE SHALL BE INSTALLED 4'-0" ABOVE
FINISHED FLOOR.
12. ALL ROUND BRANCH DUCTS TO DIFFUSERS SHALL MATCH NECK SIZES SHOWN ON
SCHEDULE, UNLESS OTHERWISE NOTED.
13. ALL DIFFUSERS, GRILLES AND REGISTERS SHALL BE SIZED TO HAVE A MINIMUM FREE
AREA OF 70% AND MEET PERFORMANCE CRITERIA SCHEDULED.
14. CONTRACTOR SHALL ONLY USE DESIGNATED AREAS WITHIN THE EQUIPMENT FOR
PENETRATIONS OF ELECTRICAL CONDUITS AND CONTROL CONDUITS. THESE
PENETRATIONS MUST BE WEATHERTIGHT. IF A CONTRACTOR PENETRATES ANY AREAS
IN THE EQUIPMENT THAT IS NOT DESIGNATED BY THE MANUFACTURER FOR
PENETRATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REPAIRS TO THE
EQUIPMENT, TO INSURE IT IS WEATHERTIGHT. IF EQUIPMENT CAN NOT BE MADE
WEATHER TIGHT THE CONTRACTOR SHALL BE REQUIRED TO REPLACE EQUIPMENT AT
THEIR OWN EXPENSE.
GENERAL NOTES
ABBREVIATIONS
ø DIAMETER AHU-x AIR HANDLING UNIT DESIGNATION
AMPS AMPERES
APPROX APPROXIMATE
AUX AUXILIARY
BAS BUILDING AUTOMATION SYSTEM
CFM CUBIC FEET PER MINUTE
COMP COMPRESSOR
COP CLEANOUT PLUG
CU-x CONDENSING UNIT DESIGNATION
DB DRY BULB
DDC DIRECT DIGITAL CONTROL
DX DIRECT EXPANSION
EAT ENTERING AIR TEMPERATURE
EMER EMERGENCY
ESP EXTERNAL STATIC PRESSURE
°F DEGREES FAHRENHEIT
FA FREE AREA
FLA FULL LOAD AMPS
HP HORSEPOWER
IN INCH/INCHES
kA KILO AMPS
KW KILOWATTS
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
MBH 1000 BRITISH THERMAL UNITS PER HOUR
MCA MINIMUM CIRCUIT AMPS
MIN MINIMUM
MOCP MAXIMUM OVER CURRENT PROTECTION
NC NOISE CRITERIA
NO NUMBER
OA OUTSIDE AIR
ΔP PRESSURE DIFFERENTIAL
PH PHASE
QTY QUANTITY
RL REFRIGERANT LIQUID
RPM REVOLUTIONS PER MINUTE
RS REFRIGERANT SUCTION
RTU-x ROOFTOP UNIT DESIGNATION
SCCR SHORT CIRCUIT CURRENT RATING
SCR SILICON CONTROLLED RECTIFIER
SEER SEASONAL ENERGY EFFICIENCY RATING
SENS SENSIBLE
SF SQUARE FEET
TYP TYPICAL
V VOLTS
VFD VARIABLE FREQUENCY DRIVE
VTR VENT THROUGH ROOF
WB WET BULB
WG WATER GAUGE
LEGEND
A CFM
XX
XX
SD
MXXX
(X"/X") ø
COP
DIFFUSER, REGISTER, AND GRILLE, CFM AS INDICATED
THERMOSTAT OR TEMPERATURE SENSOR,
CONTROLLING UNIT AS INDICATED
SECTION: LETTER "A"
SEE SHEET MXXX
CONTROL DAMPER
SMOKE DETECTOR LOCATION
HUMIDITY SENSOR
SENSOR WITH GUARD
SUPPLY AIR DEVICE WITH FLEXIBLE DUCT
SUPPLY AIR DEVICE
90° DUCT ELBOW - TURNED DOWN
DUCT ELBOW WITH TURNING VANES
DUCT SECTION - RETURN/EXHAUST
DUCT SECTION - SUPPLY
DUCTWORK TURNING DOWN
90° DUCT ELBOW - TURNED UP
90° DUCT ELBOW - TURNED DOWN
SIDEWALL GRILLE OR REGISTER
ROOF MOUNTED EXHAUST FAN
ROOF MOUNTED INTAKE HOOD
ROOF MOUNTED EXHAUST OR RELIEF HOOD
SUPPLY AIR DEVICE
RETURN AIR DEVICE
SUPPLY AIR DEVICE
NEW DUCT
90° DUCT ELBOW - TURNED DOWN - RETURN
90° DUCT ELBOW - TURNED DOWN - SUPPLY
CLEANOUT PLUG
ROUND DUCT
DIRECTION OF AIRFLOW
POINT OF CONNECTION FOR NEW WORK
REMOVE EXISTING TO THIS POINT
DEMOLITION NOTE
EXISTING SIZES AS INDICATED
NEW WORK NOTE
EXISTING TO REMAIN
NEW WORK
EXISTING TO BE REMOVED
BALANCE EXISTING AIR TERMINAL TO CFM INDICATEDXXX
CD
D
RS
RL
NEW PIPING
REFRIGERANT LIQUID PIPING
PIPING TO BE REMOVED
REFRIGERANT SUCTION PIPING
DIRECTION OF PITCH FOR PIPING OR DUCTWORK
PIPE DOWN
PIPE UP
DRAIN PIPING
90° DUCT ELBOW - TURNED UP
ENLARGED PLAN: NUMBER "1"
SEE SHEET MXXX
T
H
A
MXXX
D1
T
REFRIGERANT PIPING DIAGRAM
NOT TO SCALE
INDOOR COIL
OUTDOOR UNIT
AIR HANDLING UNIT
IN
OUT
RECEIVER TANK
H O
T G
AS
R
EH
EA
T
LI
N E
DISCHARGE LINE
LIQUID LINE
SUCTION LINE
HOT GAS LINE
SHUTOFF VALVE
TXV
DETAIL C
6-70 TONS
EXTERNAL
CHECK VALVE
DETAIL A
SEE DETAIL C
TXV
SEE DETAIL C
SEE DETAIL B
DETAIL B
2-31 TONS
BI-FLOW
FILTER DRIER
SU
C
TI
O
N L
IN
E
- C O
O
LI
N G
LI
Q
U
ID
L
IN
E
- C
O O
LI
N
G M
O D
E
D
IS
C H
AR
G
E
LI
N E
- H
EA
TI
N
G
LI
Q
U
ID
L
IN
E
- H
EA
TI
N G
M O
D E
CHECK
VALVE
HOT GAS
REHEAT COIL
SEE
DETAIL A
OUTDOOR
COIL
REVERSING
VALVE
FILTER
DRIER
MODULATING HOT
GAS REHEAT VALVE
COMPRESSOR
1/8" TUBING
120" LONG
10" MAX
1" MIN FROM CAP
OIL RETURN TO BE FIELD
SUPPLIED AND INSTALLED AT THE
LOWEST POINT OF THE SYSTEM
INSTALL SUCTION LINE OIL TRAPS EVERY 12
FT OF VERTICAL RISE OR AS REQUIRED.
FIELD SUPPLIED, FIELD INSTALLED.
ALL PIPE SIZES SHALL
BE PROVIDED BY
MANUFACTURER AS A
SHOP DRAWING
SUBMITTAL
(TYPICAL FOR AHU-1A/-1B AND CU-1A/-1B)
1. THE CONTRACTOR SHALL PROVIDE CONDITIONED AIR IN THE MAIN OFFICE (AREAS
SERVED BY RTU-23), LIBRARY (AREAS SERVED BY RTU-12 AND RTU-15) AND GYMNASIUM
(AREA SERVED BY EXISTING AHU-1/CU-1), FOR THE DURATION OF ALL SERVICE
INTERRUPTIONS LONGER THAN ONE DAY. THE CONTRACTOR SHALL COORDINATE AND
SCHEDULE WITH THE OWNER PRIOR TO ANY SERVICE INTERRUPTIONS. PORTABLE
ROLLING UNITS ARE ACCEPTABLE.
A. MAINTAIN OCCUPIED SPACE TEMPERATURE OF 71°F MINIMUM AND 76°F MAXIMUM.
B. MAINTAIN OCCUPIED SPACE RELATIVE HUMIDITY OF 60% MAXIMUM.
C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ELECTRICAL
POWER REQUIREMENTS OF TEMPORARY UNITS WITH THE BUILDING'S ELECTRICAL
SYSTEMS AND SHALL BE RESPONSIBLE FOR EMPTYING UNITS' CONDENSATE
CONTAINERS AS OFTEN AS REQUIRED TO PREVENT UNIT FAILURE AND
OVERFLOW.
TEMPORARY CONDITIONING NOTES
REVERSING VALVE
HEATING MODE
REVERSING VALVE
COOLING MODE
OIL
SEPARATOR
KD
A
AutoCAD SHX Text Lic. No. 023349
AutoCAD SHX Text
KEVIN D. ALLEN
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text A
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
D
IN
W
ID
D
IE
C O
U N
TY
P
U
BL
IC
S
C H
O O
LS
5-
/2
2/
C O
X
RO
A D
Co ns ul tin g En gi ne er s
TH
O
M
PS
O N
E
N
TE
RP
RI
SE
P
A
RK
W A
Y G
LE
N
A
LL
EN
, V
A
H A
M
PT
O N
, V A
S . L
YN
N
H A
VE
N
R O
A D
VA
B
EA
CH
, V A
TE
LE
PH
O N
E:
(7
) 5
-4
PR
O
JE
CT
N U
M
BE
R:
2-
2.
04.22.2024
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
SC
H
O O
L
- H
VA
C
EL
EC
TR
IC
AL
U
PG
R
AD
ES
M-002
BD
C
SL
S
KD
A
M
EC
H
AN
IC
AL
S C
H
ED
U
LE
S
WB(°F)DB(°F)
EAT
REMARKS
REMARKS:
HPCFM ESP
(IN.)
TOTAL
(MBH)
EAT
DB(°F) WB(°F)
LAT
DB(°F) WB(°F)
UNIT
NO.
UNIT
NO.OA
CFM
SELECTION BASED
ON "AAON"
OPERATING
WEIGHT (LBS.)SENS
(MBH)
TOTAL
(MBH)
EAT
DB(°F) WB(°F)
LAT
DB(°F) WB(°F) HEATER QTYTOTAL KW
LAT DB
(F°)
EAT DB
(F°)
CAPACITY
(MBH)
LAT DB
(F°)
EAT DB
(F°)
UNIT
WEIGHT
(LBS)
SELECTION
BASED ON
"AAON"
REFER TO SPECIFICATION SECTION 230500 FOR ADDITIONAL
REQUIREMENTS.
2 ELECTRICAL DISCONNECTS FOR AIR HANDLING UNIT AND
CONDENSING UNITS PROVIDED BY DIV 26.
3 PROVIDE WITH STAINLESS STEEL DRAIN PAN AND
CONDENSATE OVERFLOW PROTECTION SWITCH.
PROVIDE WITH FACTORY-INSTALLED HAIL GUARDS TO
PROTECT CONDENSER COILS.
PROVIDE WITH PHASE FAILURE MONITOR AND BROWNOUT
PROTECTION.
5 DX COOLING COIL PERFORMANCE DATA BASED ON GROSS
COIL CAPACITY. COIL ENTERING AIR TEMPERATURES BASED
ON 95°F DB/78°WB AMBIENT AND 77°F DB/66°F WB RETURN AIR
TEMPERATURES.6
PROVIDE WITH SCR-CONTROLLED, FULLY MODULATING
AUXILIARY ELECTRIC HEAT TO SUPPLEMENT HEAT PUMP
OPERATION. PROVIDE WITH EMERGENCY ELECTRIC HEATING
COIL FOR PARTIAL HEAT IN EVENT OF COMPRESSOR FAILURE.
PROVIDE WITH BIPOLAR IONIZATION AIR PURIFICATION
SYSTEM. REFER TO SPECIFICATION SECTION 230500 2.9.B
FOR REQUIREMENTS. A 24-VOLT STEP DOWN TRANSFORMER
SHALL BE PROVIDED BY THE UNIT MANUFACTURER.
HEATING DATA BASED ON 10°F DB/9°F WB AMBIENT AND 68°F
DB/54°F WB RETURN AIR TEMPERATURES.
REFER TO SEQUENCES OF OPERATION ON M300 SERIES
DRAWINGS FOR ALL REQUIRED CONTROL POINTS.
PROVIDE WITH MERV-13 FILTERS.
10 PROVIDE WITH FULLY MODULATING HOT GAS REHEAT COIL.
PROVIDE WITH 65KA SCCR.14
PROVIDE WITH VARIABLE CAPACITY COMPRESSORS ON LEAD
REFRIGERATION CIRCUIT.
PROVIDE UNIT WITH MIXING BOX WITH INTEGRAL OA AND RA
CONTROL DAMPERS.
16THRU
4 UNIT SHALL BE CONFIGURED FOR R-410A REFRIGERANT.
AHU-1A
SUPPLY FAN DX COOLING COIL DATA
RPM
OUTLET SOUND
POWER (dBA)
NO. OF
COMP.
ELECTRIC HEATING DATA (AUX/EMERGENCY)
79.5/50.4 99.5/90.6 21.0/42.0 4/8
REVERSE CYCLE HEATING DATA
V3-DRB-8-0-162C-3H4 CFA-016-C-A-8-DJ00LCU-1A 95.0 78.0 2 80 208 3 13283300 1000 1.25 1@4 1576 81 173.2 103.8 82.5 70.0 52.6 52.4 107.0 50.4 44.1 79.5 56.8 52.6 72.0 69.5
FLA MCA
55 61
MOCP V PH
ELECTRICAL
175 208 3
FLA MCA
125 156
MOCP V PH
ELECTRICALHOT GAS REHEAT DATA
INDOOR UNIT
1294 16THRUAHU-1B 81.0/50.7 100.8/80.4 42.0/63.0 8/12 V3-ERB-8-0-162C-3MS CFA-031-D-A-8-GJ00LCU-1B 95.0 78.0 4 150 208 3 24166850 2000 1.50 2@4 1713 86 364.5 215.7 82.4 69.9 51.8 51.6 226.5 50.7 44.3 81.0 57.4 51.8 72.0 146.0 124 131225 208 3192 196
OUTDOOR UNIT
SPLIT SYSTEM HEAT PUMP SCHEDULE - GYMNASIUM
AutoCAD SHX Text Lic. No. 023349
AutoCAD SHX Text
KEVIN D. ALLEN
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
D
IN
W
ID
D
IE
C O
U N
TY
P
U
BL
IC
S
C H
O O
LS
5-
/2
2/
C O
X
RO
A D
Co ns ul tin g En gi ne er s
TH
O
M
PS
O N
E
N
TE
RP
RI
SE
P
A
RK
W A
Y G
LE
N
A
LL
EN
, V
A
H A
M
PT
O N
, V A
S . L
YN
N
H A
VE
N
R O
A D
VA
B
EA
CH
, V A
TE
LE
PH
O N
E:
(7
) 5
-4
PR
O
JE
CT
N U
M
BE
R:
2-
2.
04.22.2024
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
SC
H
O O
L
- H
VA
C
EL
EC
TR
IC
AL
U
PG
R
AD
ES
M-003
BD
C
SL
S
KD
A
VE
N
TI
LA
TI
O
N C
AL
C
U
LA
TI
O
N S
GYMNASIUM VENTILATION CALCULATION
NOTE: OUTSIDE AIR FLOW RATES AS SCHEDULED ARE GENERALLY CALCULATED VIA THE ASHRAE VENTILATION RATE PROCEDURE (VRP). ANY VENTILATION EXCEEDING THE VRP REQUIREMENT IS DUE
TO A POSITIVE SPACE PRESSURE REQUIREMENT. WHERE EXISTING ELECTRICAL CAPACITY OR
ADAPTER CURB SIZE REQUIREMENTS LIMITED THE AMOUNT OF OUTSIDE AIR POSSIBLE, VENTILATION RATES ARE IN COMPLIANCE WITH THE INDOOR AIR QUALITY (IAQ) PROCEDURE, WHILE MAINTAINING COMFORTABLE SPACE TEMPERATURE AND HUMIDITY LEVELS IN COMPLIANCE WITH ASHRAE 90.1.
(TYP. AHU-1A AND -1B)
AutoCAD SHX Text Lic. No. 023349
AutoCAD SHX Text
KEVIN D. ALLEN
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
T
ARCHITECTS, PC
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
D
IN
W
ID
D
IE
C O
U N
TY
P
U
BL
IC
S
C H
O O
LS
5-
/2
2/
NOT TO SCALE
KEY PLAN
A B
C O
X
RO
A D
Co ns ul tin g En gi ne er s
TH
O
M
PS
O N
E
N
TE
RP
RI
SE
P
A
RK
W A
Y G
LE
N
A
LL
EN
, V
A
H A
M
PT
O N
, V A
S . L
YN
N
H A
VE
N
R O
A D
VA
B
EA
CH
, V A
TE
LE
PH
O N
E:
(7
) 5
-4
PR
O
JE
CT
N U
M
BE
R:
2-
2.
04.22.2024
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
SC
H
O O
L
- H
VA
C
EL
EC
TR
IC
AL
U
PG
R
AD
ES
MD-101
BD
C
SL
S
KD
A
AR
EA
A F
LO
O
R P
LA
N
M
EC
H
AN
IC
AL
D
EM
O
LI
TI
O
N
DISCONNECT AND REMOVE GYM MEZZANINE
FLOOR-MOUNTED AIR HANDLING UNIT COMPLETE
INCLUDING CONCRETE PAD, SUPPORTS, CONTROLS,
AND ACCESSORIES.
DISCONNECT AND REMOVE DUCTWORK COMPLETE TO
POINT INDICATED.
REMOVE GYM RETURN GRILLE AND PLENUM COMPLETE.
TEMPORARILY PATCH OPENING IN GYM MEZZANINE
WALL.
REMOVE OUTSIDE AIR DUCTWORK COMPLETE UP TO
ROOF-MOUNTED INTAKE HOOD.
DISCONNECT AND REMOVE ROOF-MOUNTED INTAKE
HOOD AND CAP ROOF CURB. REFER TO "ROOF CURB
CAPPING DETAIL" ON M-201 FOR ADDITIONAL
INFORMATION.
DISCONNECT AND REMOVE WALL-MOUNTED
TEMPERATURE SENSOR AND CONTROL WIRING
COMPLETE.
DISCONNECT AND REMOVE ROOF-MOUNTED
CONDENSING UNIT COMPLETE INCLUDING
ACCESSORIES, CONTROLS, AND SUPPORTS.
DISCONNECT AND REMOVE CONDENSATE DRAIN PIPING
COMPLETE.
DISCONNECT AND REMOVE REFRIGERANT PIPING
COMPLETE.
REMOVE 72"/30" RELIEF DUCTWORK AND DAMPER.
REMOVE ROOF MOUNTED RELIEF HOOD AND CAP
EXISTING ROOF CURB. REFER TO "CURB CAPPING
DETAIL" ON DRAWING M-201 FOR ADDITIONAL
INFORMATION.
EXISTING DUCT HEATER AND TRANSFER FAN TO
REMAIN.
DEMOLITION NOTES
DESCRIPTIONNO.
D1
D2
AREA A FLOOR PLAN - MECHANICAL - DEMOLITION
SCALE: 1/8" = 1'-0"
M
AT
C H
LI
N
E
SE
E
SH
EE
T
M D
-1
M
AT
C H
LI
N
E
SE
E
SH
EE
T
M D
-1
T
193 189
192 190
186 185
197 199
GYMNASIUM MEZZANINE PLAN - DEMOLITION
SCALE: 1/8" = 1'-0"
T
171 170
107 111
D
D2
D3 D4
30"/38"
(30"/24")
(24"/16")
(24"/16")
AHU-1
(12"/12")
(12"/12" DN)
D8
(18"/12") (16"/12")
(28"/12") (36"/12")
(3 6"
/9
(20"/9")(20"/9")
(14"/9")
(14"/6")
(16"/10")
(EF-1)
(AHU-6)
(3/4")
D3
D4
D8
(24"/14" DN)
(16"/16" UP TO EF-2)
D14
D15
RS
RL
REFER TO FLOOR
PLAN FOR
CONTINUATION
(6"/7")
(20"/14" UP TO
MEZZANINE)
(14"/9")
R S
R L
D16
D18 D18
REFER TO MEZZANINE PLAN
ON THIS DRAWING FOR WORK
ABOVE THIS AREA
D15
BD CU-1 ON
ROOF
RS/RL UP
TO ROOF
(18"/18" SUPPLY
TRANSITION TO 14"/18")
(27"/10" RETURN
TRANSITION TO 14"/18")
(RTU-1 ON
ROOF)
A
MD-101
(RTU-22)
(RTU-2)
(RTU-2 ON
ROOF)
(RTU-22
ON ROOF)
(RTU-23
ON ROOF)
(13"/9")
(13"/9")
REFER TO MD-102
FOR CONTINUATION
SECTION
SCALE: 1/4" = 1'-0"
A
MD-101
D2 D4
D3
D6
D (3/4")
(13"/9")
(13"/9")
REFER TO MD-102
FOR CONTINUATION
(CU-7 ON
ROOF)
AHU-1
30"/38" 18"/60"
14"/8"
194 195
D6
D11
D14
D15
D16
NOTE: EXISTING CONDITIONS ILLUSTRATED HAVE BEEN
DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS
AND LIMITED NON-INVASIVE FIELD INVESTIGATION. THE
CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR
TO COMMENCEMENT OF WORK, COORDINATE AND MAKE
ADJUSTMENTS AS NECESSARY.
CEILING REPLACEMENT NOTE: CONTRACTOR SHALL
COORDINATE ALL WORK WITH EXISTING CEILING CONDITIONS
AND REMOVE ACOUSTIC CEILING TILES AND ACCESSORIES AS
NECESSARY TO FACILITATE INSTALLATION OF NEW DUCTWORK
AND DIFFUSERS. EXISTING CEILING GRID SHALL REMAIN IN
PLACE THROUGHOUT DURATION OF CONSTRUCTION. UPON
COMPLETION OF WORK, CONTRACTOR SHALL REINSTALL ALL
CEILING TILES AND ANY OTHER ACCESSORIES TEMPORARILY
REMOVED DURING CONSTRUCTION.
CONCRETE PAD
D18
(DHC-2)
(TF-2)(18"/8") (TF-1)
(DHC-2)
(18"/8")
(12"/12"
UP)
EXISTING
STRUCTURE (TYP.)
(14"/8") (14"/10") (14"/12")
(24"/16") (26"/18")
(24"/16")
(20"/14") (20"/14")
(20"/14")(20"/14")
(20"/14")
ROOF LADDER
D1
T
T
T
T
TT
D11
T
T
(CU-6 ON
ROOF)
D1
(AHU-7)
MECHANICAL WORK WITHIN SHADED AREAS
NOT INCLUDED IN SCOPE OF PROJECT
AutoCAD SHX Text Lic. No. 023349
AutoCAD SHX Text
KEVIN D. ALLEN
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text H
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text G
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
D
AT
E
D R
AW
N
PR
O
JE
C
T
D
ES
IG
N
ED
C H
EC
KE
D
(804)277-8987
115 South 15 th Street, Suite 202 Richmond, Virginia 23219
M
AR
K
R
EV
IS
IO
N S
D
AT
E
BY
D
ES
C R
IP
TI
O N
0' 16' 32' 48' 1/32" = 1'-0"
0' 8' 16' 24' 1/16" = 1'-0"
4' 0' 4' 8' 16' 3/32 = 1'-0"
0' 4' 8' 12' 1/8" = 1'-0"
0' 2' 4' 6' 1/4" = 1'-0"
0' 1' 2' 4' 3/8" = 1'-0"
3' 0' 1' 2' 3' 1/2" = 1'-0"
6" 0' 1' 2' 3/4" = 1'-0"
6" 0' 6" 1' 1.5' 1" = 1'-0"
3" 9" 0' 3" 6" 1' 1 1/2" = 1'-0"
9" 0' 2" 4" 6" 3" = 1'-0"
5"3"1" 0' 1" 2" 3" 6" = 1'-0"
0' 1" 1.5" 12" = 1'-0"
D
C
B
A
E
D
C
B
A
E
SHEET
PR
O
JE
C
T
D R
AW
IN
G
1 2 3 4 5 6
1 2 3 4 5 6
D
IN
W
ID
D
IE
C O
U N
TY
P
U
BL
IC
S
C H
O O
LS
5-
/2
2/
NOT TO SCALE
KEY PLAN
A B
C O
X
RO
A D
Co ns ul tin g En gi ne er s
TH
O
M
PS
O N
E
N
TE
RP
RI
SE
P
A
RK
W A
Y G
LE
N
A
LL
EN
, V
A
H A
M
PT
O N
, V A
S . L
YN
N
H A
VE
N
R O
A D
VA
B
EA
CH
, V A
TE
LE
PH
O N
E:
(7
) 5
-4
PR
O
JE
CT
N U
M
BE
R:
2-
2.
04.22.2024
SU
N
N
YS
ID
E
EL
EM
EN
TA
R Y
SC
H
O O
L
- H
VA
C
EL
EC
TR
IC
AL
U
PG
R
AD
ES
MD-102
BD
C
SL
S
KD
A
R O
O F
PL
AN
M
EC
H
AN
IC
AL
D
EM
O
LI
TI
O
N
DISCONNECT AND REMOVE ROOF-MOUNTED INTAKE
HOOD AND CAP ROOF CURB. REFER TO "ROOF CURB
CAPPING DETAIL" ON M-201 FOR ADDITIONAL
INFORMATION.
DISCONNECT AND REMOVE ROOF-MOUNTED
CONDENSING UNIT COMPLETE.
DISCONNECT AND REMOVE REFRIGERANT PIPING
COMPLETE.
DISCONNECT AND REMOVE EXISTING BACKDRAFT
DAMPER FROM 72"/30" GRAVITY RELIEF VENT.
DEMOLITION NOTES
DESCRIPTIONNO.
D6
D15
ROOF PLAN - MECHANICAL - DEMOLITION
SCALE: 1/16" = 1'-0"
HIGH ROOF
(EF-2)
CU-1
(RTU-1)RS/RL DN
MEDIUM ROOF
ROOF LADDER
D6 (RTU-2)
(RTU-22)
(RTU-23)
(CU-6)
(CU-7) (CU-5) (RTU-21)
(RTU-20) (RTU-18) (RTU-16)
(RTU-17)(RTU-19)
(CU-4)
LOW ROOF
(RTU-10)
(RTU-9)
(RTU-11)
(RTU-15)
(RTU-14)
(RTU-13)
(RTU-12)
(RTU-8)
(RTU-7)
(CU-3)(RTU-5)
(RTU-6)(RTU-4)
(RTU-3)(CU-2)
D11
D16
(GRV)
(RD) (RD) (RD)
(RD)
(RD)
(RD)(RD)(RD)
(RD)
NOTE: EXISTING CONDITIONS ILLUSTRATED HAVE BEEN
DETERMINED FROM ORIGINAL CONSTRUCTION DOCUMENTS
AND LIMITED NON-INVASIVE FIELD INVESTIGATION. THE
CONTRACTOR SHALL INVESTIGATE FIELD CONDITIONS PRIOR
TO COMMENCEMENT OF WORK, COORDINATE AND MAKE
ADJUSTMENTS AS NECESSARY.
ROOFING NOTE: CONTRACTOR SHALL UTILIZE ALL EXISTING
WALKING PADS TO PROTECT ROOF FROM FOOT TRAFFIC AND
TOOLS AS BEST AS POSSIBLE. ANY ROOF OPENINGS FROM
PITCH POCKETS, CONDUIT, REFRIGERANT PIPING BEING
REMOVED SHALL BE FULLY CLOSED UP AND PATCHED FOR
WATERTIGHTNESS. CONTRACTOR SHALL LAY SHEETS OF
PLYWOOD ON ROOF SURFACE AROUND ROOFTOP UNITS TO
FURTHER PROTECT SURFACE DURING UNIT REPLACEMENT.
PLYWOOD SHEETING SHALL BE SECURED TO ROOF SURFACE IN
ORDER TO MITIGATE WIND LIFTING.
(ROOF
HATCH)
D11
D16
D15
MECHANICAL WORK WITHIN SHADED AREAS
NOT INCLUDED IN SCOPE OF PROJECT
AutoCAD SHX Text Lic. No. 023349
AutoCAD SHX Text
KEVIN D. ALLEN
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .