This is a floor plan document for the Sumter Airport Terminal Building renovation project located at 2955 Airport Road, Sumter, South Carolina 29153, prepared by Woods Dendy Architects, LLC. The renovation includes renovations and additions to the terminal building and encompasses multiple functional areas including a fireside lounge, waiting area, restrooms, cafe, offices, pilot lounge, staff work area, conference room, and storage spaces. The floor plan indicates specific construction requirements including verification of existing subfloor conditions and finished floor elevations, inspection and repair of existing window sills and leaks, installation of new storefront systems, ADA-compliant fixtures and accessibility features, new mechanical equipment, concrete paving corrections, and various built-in casework and furnishings. The plan references multiple architectural sheets and specifications including accessibility standards, engineering drawings, and keynotes detailing materials such as carpet tile flooring, wood plank porcelain tile flooring, stainless steel counters and cabinets, and electronic door access systems. Contractors are directed to verify all mounting heights, support requirements, and maintain acoustical integrity where sound insulation is specified.
The document is marked as a preliminary progress set not for construction, dated October 12, 2026, drawn at a scale of 1/4" = 1'-0". The floor plan includes numerous dimensional notations, keynotes providing specifications for existing and new materials, and references to standard ADA threshold and hardware requirements on all doors. The project involves coordination between the airport authority, architectural firm, and engineering consultants to ensure compliance with accessibility standards and proper installation of specialized equipment including ice makers, smart boards, display refrigerators, copiers, and automatic door openers.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFQ-Interior Design-Sumter County Airport Terminal.pdf | ||
| Sumter Terminal Renovation- Renderings.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. ALL DIMENSIONS ARE TO FACE OF EXISTING FINISH, FACE OF
NEW STUD AND/ OR SUBFLOOR UNLESS OTHERWISE NOTED.
2. CONTRACTOR TO VERIFY EXISTING SUBFLOOR FLOOR
CONDITION AND ELEVATION. NEW FINISHED FLOOR ELEVATION
TO MATCH EXISTING FINISHED FLOOR ELEVATION UNLESS
OTHERWISE NOTED.
3. CONTRACTOR TO VERIFY ALL ADJACENT GRADE HAS POSITIVE
SLOPE AWAY FROM BUILDING.
4. SEE ENGINEERING DRAWINGS FOR ADDITIONAL INFORMATION.
5. SEE SHEET G0.10 FOR ACCESSIBILITY STANDARDS.
6. CONTRACTOR SHALL VERIFY ALL MOUNTING HEIGHTS AND
SUPPORT REQUIREMENTS WITH EQUIPMENT, DEVICE, AND
CASEWORK MFR BEFORE INSTALLING BACKING BLOCKS AND
SUPPORT.
7. WHERE SOUND INSULATION IS NOTED, SOUND INSULATION
SHALL BE CONTINUES BEHIND WALL PENETRATIONS TO
MAINTAIN ACOUSTICAL INTEGRITY.
FLOOR PLAN NOTES
A4.011
A3.02
A3.02
A3.01
A4.01
A5.02
A5.01
A3.02
A3.01
A3.01
RECEPTION
DESK
A4.01
A4.01
A4.01
A4.01
A4.01
A3.02
A5.01
A5.03
INSPECT AND REPAIR LEAKS
AT EXISTING CONFERENCE
RM WINDOW SILL
INSPECT AND REPAIR LEAKS AT
EXISTING NORTH CLERESTORY
WINDOW SILLS
1.36
1.14
1.30
1.33
1.10
1.36
1.35
1.14
1.17
1.14
1.17
1.28
1.29
1.32
1.31
1.30
1.14
1.13
1.27
1.21
1.34
1.20
1.37
1.37
1.37
1.37 1.37
1.24
1.25
1.23
1.23
1.23
1.4
1.4
1.5
1.38
1.7
1.7
1.7
1.7
1.6
1.6
1.36
1.34
1.38
1.2
1.26
1.22
1.40
1.40
1.30
1.16.
1.37
1.37
1.38
TYP.
TYP.
TYP.
TYP.
TYP.
1.19
TYP.
TYP.
OPEN TO
LIGHTWELL ABOVE
1.42
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
1.40
TYP.
1.45
1.2
1.9
TYP.
1.1
1.3
1.3
1.3
1.1
1.3
1.3
1.43
1.44
1.43
1.15
Ex1
Ex2
Ex3
Ex6
Ex5
Ex4
Ex7
110.1113.1 112.1
111.1
103.1
104.1
106.1
108.1
107.1
110.2
115.1
118.1
116.1
105.1
109.1
FIRESIDE
LOUNGE
WAITING
AREA
RESTROOM
VESTIBULE
JANITOR
MENS
RESTROOM
WOMENS
RESTROOM
CAFE
OFFICE
OFFICE
PILOT
RESTROOM
PILOT
LOUNGE
HALLWAY
OFFICE
F.B.O.
MANAGER
OFFICE
F.B.O.
STAFF
WORK AREA
CONFERENCE
ROOM
IT/STOR.
ELEC.
STREET
SIDE ENTRY
RAMP SIDE
PATIO
101102
105 106
CL.
A5.01 2
1.37
1.37
EXISTING
PLANTING
EXISTING
PLANTING
EXISTING
PLANTING
A5.01 4
A5.01
1.48
1.48
1.48
1.47
1.47
1.47
1.48
1.47
1.48
1.47
1.47
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
1.47
TYP.
1.46
1.46
1.46
A5.02
A5.03
A5.03
FEC
A7.02
A7.02
A7.01
A7.01
A7.01
A7.01
A7.01
A7.01
A7.01
A7.02
A7.02
A5.04
A5.04
A5.04 2
A5.04
A5.04
A7.05
REMOVE AND REPLACE CONC.
PAVING THIS AREA TO CORRECT
CONCRETE ISSUES, INCLUDE
ADEQUATE EXPANSION JOINTS
PROJECT NO.
R E
N O
V A
T
IO
N S
A N
D A
D D
IT
IO
N S
T O
AMERICAN INSTITUTE OF ARCHITECTS MEMBERS
Woods Dendy Architects, LLC
THESE DRAWINGS ARE THE PROPERTY OF WOODS DENDY
ARCHITECTS, LLC, AND ARE NOT TO BE USED FOR MAKING ANY
REPRODUCTION OR FOR THE CONSTRUCTION OF ANY BUILDING
WITHOUT FIRST OBTAINING WRITTEN AUTHORIZATION FROM
THE COPY-RIGHT OWNER, WOODS DENDY ARCHITECTS, LLC.P
L
O T
I N
F O
REVISION SCHEDULE
P R
E L
IM
IN
A
R Y
N
O T
F O
R C
O N
S T
R U
C T
IO
N
2201 BOUNDARY ST, SUITE 103
BEAUFORT, SC 29902
1 HAYWOOD ST, SUITE 421
ASHEVILLE, NC 28801
/1 /2
:0
:3
A M
A u to d e s k D o c s /2
S u m te r T e rm in a l/ S u m te r
T e rm in a l R e n o v a ti o n .r v t
25007
DATE: 10/12/26
DRAWN BY: SA CHECKED BY: HD
A2.04
S U
M T
E R
A
IR
P O
R T
T E
R M
IN
A
L B
U
IL
D
IN
G
A
IR
P O
R T
R O
A D
S U
M T
E R
S
C
CD PROGRESS SET
FLOOR PLAN
1/4" = 1'-0"
FLOOR PLAN
N
FLOOR PLAN KEYNOTES
NO. KEYNOTE
1.1 EXIST. WALL TO REMAIN
1.2 EXIST. COLUMN TO REMAIN
1.3 EXIST. STOREFRONT SYSTEM TO REMAIN; INSPECT
WATERPROOFING AND REPLACE AS REQ'D
1.4 NEW STOREFRONT SYSTEM TO MATCH EXIST.
1.5 STOREFRONT DOOR WITH TRANSOM ABOVE
1.6 ALL DOORS TO HAVE ADA THRESHOLD AND HARDWARE
1.7 EXIST. CONC. PATIO / STAIR AND LANDING / RAMP /
WALKWAY TO REMAIN
1.9 DOWNSPOUT
1.10 NEW ELEC. PANEL PER ENG.
1.13 COUNTER
1.14 COUNTER / BASE CABINET
1.15 S.ST. EXT. COUNTER / BASE CABINET
1.16 BUILT-IN DESK
1.17 UPPER CABINET
1.19 CUSTOM F.B.O. DESK
1.20 BUILT-IN ELEC. FIREPLACE
1.21 BUILT-IN SHELVING / DISPLAY CASE
1.22 FROST INT. GLASS AT EXISTING STOREFRONT WINDOW AND
ADD NEW 7'-0" HT. RR WALL
1.23 ADA RESTROOM
1.24 ADA CURBLESS SHOWER
1.25 MOP SINK
1.26 NEW TRENCH DRAIN PER ENG
FLOOR PLAN KEYNOTES
NO. KEYNOTE
1.27 HI-LOW DRINKING FOUNTAIN WITH COOLER & WATER
BOTTLE FILLER
1.28 ICE MAKER WITH FLOOR MOUNT KIT; INSTALL WITHOUT
LEGS AND SEAL CONTINUOUSLY TO FINISHED FLOOR PER
MANUFACTURER'S INSTRUCTIONS.
1.29 MICROWAVE
1.30 COFFEE MAKER
1.31 S.ST. REFRIGERATOR
1.32 DISPLAY REFRIGERATOR WITH GLASS DOOR
1.33 SMART BOARD DISPLAY
1.34 WALL MOUNTED TV
1.35 COPIER
1.36 FURNITURE
1.37 CARPET TILE FLOORING
1.38 WOOD PLANK PORCELAIN TILE FLOORING
1.40 ROOF PRJECTION ABOVE
1.42 NEW ADA COMPLIANT PUSH BUTTON AUTOMATIC DOOR
OPENER
1.43 EXIST. SITE FENCE TO REMAIN
1.44 NEW SITE FENCE TO MATCH EXIST.
1.45 NEW MECHANICAL EQUIPMENT PER ENG ON EXIST. CONC.
PAD
1.46 NEW WALL MOUNTED ELECTRONIC DOOR ACCESS KEYPAD
1.47 EXIST. METAL RAILING
1.48 NEW 1-1/2" DIA. METAL HANDRAIL, ATTACH TO EXIST.
RAILING; MATCH EXIST. RAILING MATERIAL AND FINISHES