WORK STATEMENT
SHIP
USS Hampton (SSN-767)
COAR:
001-15SET COAR
001-15 26-001
ITEM/JSN: 551-11-001 / WI01-2312/2313
SURVEYOR:
Tom Loepfe
1. SCOPE:
1.1 TITLE: High Pressure Air System Reducing Manifold; In-place Repair
1.2 LOCATION OF WORK:
1.2.1 Torpedo Room
1.3 Identification:
1.3.1 Quantity (one) Each; High Pressure Air System Reducing Manifold AHP-51, 4500/2000 PSI Reducer, Level-I, APL # 887355424 (Post-ShipAlt 3503), Manufacture: VACCO
1.3.2 Quantity (one) Each; High Pressure Air System Reducing Manifold AHP-56, 4500/700 PSI Reducer, Level-I, APL # 8873553424(Post-ShipAlt 3503), Manufacture: VACCO
2. REFERENCES:
2.1 NAVSEA Standard Items 2.2 MS 5510-081-042 REV C, CHG-5, Inspect; Repair High Pressure Air System Reducing Manifold (AHP-051, AHP-056)
3. REQUIREMENTS:
3.1 Accomplish the requirements of 009-90 of 2.1 for the Technical Representation (OEM) of each equipment listed in 1.3.1 and 1.3.2.
3.2 Accomplish the requirements of 009-27 of 2.1 for each equipment listed in 1.3.1 and 1.3.2.
3.2.1 Submit one legible copy, in hard copy or approved electronic media, of a report listing the results of 3.2 to the SUPERVISOR.
3.3 Perform an in-place repair of each equipment listed in 1.3.1 and 1.3.2 using 2.2 for guidance.
(V) (G) IN-SYSTEM OPERATIONAL TEST
3.4 Perform an Operational Test of each equipment listed in 1.3.1 and 1.3.2 using 2.2 for guidance. Hold Pressure for 30 minutes. No external leakage allowed.
3.4.1 Submit one legible copy, in hard copy or approved electronic media, of a report listing the results of 3.4 to the SUPERVISOR.
4. NOTES:
4.1 S/F POC is the 3MC.
4.2 OEM is VACCO industries; (626) 450-6427
5. GOVERNMENT FURNISHED MATERIAL (GFM):
5.1 None
Page I of 2