This statement of work and associated drawings outline requirements for an electrical system upgrade at the Russian Bishop's House, part of Sitka National Historical Park. The project scope involves demolishing portions of the existing electrical distribution system located primarily in the crawl space under the first floor, and installing new electrical components and wiring. Work includes penetrating five floor boards and updating the electrical panels, raceways, boxes, devices, identification, and structured cabling as depicted. Audiovisual and interactive exhibit components are also noted requiring electrical connections at various locations indicated on the floor plans. Specifications cover materials, testing, and compliance with industry standards for a complete and code-compliant electrical system.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140P9723R0009_Amd_0001.pdf | ||
| Wage_Determination.pdf | ||
| Sol_140P9723R0009.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITKA NATIONAL HISTORICAL PARK
RUSSIAN BISHOP’S HOUSE
Furnish and Install Electrical System for First Floor Exhibits
Statement of Work
PROJECT SCOPE
The project scope includes demolition of portions of the existing electrical distribution system located primarily in the RBH crawl space under the first floor, and installing new electrical components and wiring, as further described on the attached drawings. Work includes penetrating 5 floor boards, as indicated.
26 05 00 - COMMON WORK RESULTS FOR ELECTRICAL
A. SCOPE OF WORK: FURNISH AND INSTALL ALL MATERIAL AND EQUIPMENT FOR A COMPLETE AND WORKABLE ELECTRICAL SYSTEM AS INDICATED ON THE DRAWINGS AND IN THESE SPECIFICATIONS.
8. STANDARDS, CODES AND REGULATIONS: COMPLY WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, INTERNATIONAL BUILDING CODE, AND INTERNATIONAL FIRE CODE
INCLUDING ALL STATE AND LOCAL AMENDMENTS TO THESE CODES. COMPLY WITH THE LATEST
PUBLISHED VERSION OF THE NECA STANDARD OF INSTALLATION.
C. DRAWINGS: THE DRAWINGS ARE DIAGRAMMATIC, NOT NECESSARILY SHOWING ALL OFFSETS
OR EXACT LOCATIONS OF FIXTURES, EQUIPMENT, ETC. UNLESS SPECIFICALLY DIMENSIONED. REVIEW THE DRAWINGS AND SPECIFICATIONS FOR EQUIPMENT FURNISHED BY OTHER CRAFTS BUT INSTALLED
IN ACCORDANCE WITH THIS SECTION. BRING QUESTIONABLE OR OBSCURE ITEMS, APPARENT
CONFLICTS BETWEEN PLANS AND SPECIFICATIONS, GOVERNING CODES OR UTILITIES REGULATIONS TO
THE
ATTENTION OF THE OWNER. CODES, ORDINANCES, REGULATIONS, MANUFACTURER'S INSTRUCTIONS
OR STANDARDS TAKE PRECEDENCE WHEN THEY ARE MORE STRINGENT OR CONFLICT WITH THE
DRAWINGS AND SPECIFICATIONS.
D. RECORD DRAWINGS: MARK UP A CLEAN SET OF DRAWINGS AS THE WORK PROGRESSES TO
SHOW THE DIMENSIONED LOCATION AND ROUTING OF ALL ELECTRICAL WORK WHICH WILL BECOME PERMANENTLY CONCEALED. SHOW ROUTING OF WORK IN PERMANENTLY CONCEALED BLIND SPACES WITHIN THE BUILDING. SHOW COMPLETE ROUTING AND SIZING OF ANY SIGNIFICANT REVISIONS TO THE
SYSTEMS SHOWN.
E. WORKMANSHIP: INSTALLATION OF ALL WORK SHALL BE MADE SO THAT ITS SEVERAL
COMPONENT PARTS SHALL FUNCTION AS A WORKABLE SYSTEM COMPLETE WITH ALL ACCESSORIES NECESSARY FOR ITS OPERATION. ALL MATERIAL AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS AND/OR INSTALLATION DRAWINGS
AND IN ACCORDANCE WITH NECA STANDARDS. MATERIALS AND EQUIPMENT SHALL BE NEW AND
SHALL CONFORM WITH APPLICABLE INDUSTRY STANDARDS, NEMA STANDARDS AND UNDERWRITERS
LABORATORIES STANDARDS WHERE APPLICABLE.
F. SUBMITTAL$: PROVIDE MATERIAL AND EQUIPMENT SUBMITTAL$ CONTAINING A
COMPLETE LISTING OF MATERIAL AND EQUIPMENT SHOWN ON THE DRAWINGS. INCLUDE CATALOG NUMBERS, WIRING DIAGRAMS, ROUGH-IN DIMENSIONS AND PERFORMANCE DATA FOR ALL MATERIAL
AND EQUIPMENT. SUBMITTALS SHALL BE IN ELECTRONIC .PDF FORMAT, SEPARATE FROM WORK
FURNISHED UNDER OTHER DIVISIONS. INDEX AND CLEARLY IDENTIFY ALL MATERIAL AND EQUIPMENT BY ITEM, NAME OR DESIGNATION USED ON THE DRAWINGS. SUBMITTAL REVIEW IS FOR GENERAL
DESIGN AND ARRANGEMENT ONLY AND DOES NOT RELIEVE THE CONTRACTOR FROM ANY
REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE SUBMITTALS ARE NOT CHECKED FOR QUANTITY, DIMENSION, OR FOR PROPER OPERATION. WHERE DEVIATIONS OF A SUBSTITUTE PRODUCT OR SYSTEM
PERFORMANCE HAYE NOT BEEN SPECIFICALLY NOTED IN THE SUBMITTAL BY THE CONTRACTOR,
PROVISIONS OF A COMPLETE AND SATISFACTORY WORKING INSTALLATION IS THE SOLE RESPONSIBILITY
OF THE CONTRACTOR.
G. WARRANTY: THE CONTRACTOR SHALL GUARANTEE ALL WORK EXECUTED UNDER THIS
CONTRACT TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM BENEFICIAL OCCUPANCY. ANY FAULTY MATERIALS OR WORKMANSHIP SHALL BE REPAIRED OR
REPLACED TO THE SATISFACTION OF THE OWNER DURING THE GUARANTEE PERIOD.
H. PERMITS: SECURE AND PAY FOR ALL FEES, PERMITS, ETC. REQUIRED BY LOCAL AND STATE
AGENCIES.
I. REFERENCE SYMBOLS: THE ELECTRICAL "LEGEND" ON THE DRAWINGS IS A STANDARDIZED
VERSION, AND ALL SYMBOLS SHOWN MAY NOT BE USED. USE THE "LEGEND" AS A REFERENCE FOR THE
SYMBOLS USED ON THE DRAWINGS.
26 05 05 - SELECTIVE DEMOLITION FOR ELECTRICAL
A. DEMOLITION DRAWINGS ARE BASED ON NON-DESTRUCTIVE FIELD OBSERVATION. REPORT
DISCREPANCIES TO OWNER BEFORE DISTURBING THE EXISTING INSTALLATION. DISCONNECT
ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL. PROVIDE
TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN ALL EXISTING ELECTRICAL SYSTEMS
(TELEPHONE, FIRE ALARM, LIGHTING, ELECTRICAL SERVICE, ETC.) IN SERVICE DURING CONSTRUCTION.
DISABLE SYSTEMS ONLY TO MAKE SWITCHOVERS AND CONNECTIONS.
8. OBTAIN PERMISSION FROM OWNER AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY
DISABLING SYSTEM. MINIMIZE OUTAGE DURATION AND MAKE TEMPORARY CONNECTIONS TO
MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA. WHEN WORK MUST BE PERFORMED ON
ENERGIZED EQUIPMENT OR CIRCUITS, USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS.
C. REMOVE, RELOCATE AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW
CONSTRUCTION. REMOVE ABANDONED WIRING TO SOURCE OF SUPPLY. REMOVE EXPOSED
ABANDONED CONDUIT. WHERE ABANDONED CONDUIT ENTERS EXISTING SURFACES TO REMAIN, CUT
CONDUIT FLUSH WITH WALLS AND FLOORS, AND PATCH SURFACES. DISCONNECT ABANDONED
OUTLETS AND REMOVE DEVICES. REMOVE ABANDONED OUTLETS IF CONDUIT SERVICING THEM IS
ABANDONED AND REMOVED. PROVIDE BLANK COVER FOR ABANDONED OUTLETS WHICH ARE NOT
REMOVED.
D. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND
EXTENSION WORK. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS WHICH REMAIN ACTIVE.
E. WHERE CONDUITS PASS THROUGH THE WALLS OR CIRCUITS ARE SHARED WITH EQUIPMENT
THAT IS EXISTING TO REMAIN, PROVIDE ALL WORK NECESSARY (INCLUDING EXTENDING AND RE- ROUTING CONDUITS) TO MAINTAIN ACCESS AND PROVIDE ELECTRICAL CONTINUITY TO EXISTING
SYSTEMS AND CIRCUITRY.
6 05 19 - WIRE AND CABLE
A. SUBMITTALS: NONE REQUIRED FOR THIS SECTION.
B. MATERIALS:
1. ALL CONDUCTORS SHALL BE COPPER WITH TYPE XHHW, THWN, THW OR THHN INSULATION.
MINIMUM BRANCH CIRCUIT CONDUCTOR SIZE SHALL BE #12 AWG.
2. DC CIRCUITS SHALL BE COPPER, STRANDED CONDUCTOR, 600V INSULATION,
THHN/THWN, MINIMUM SIZE 14 AWG.
3. TYPE MC CABLE: SOLID COPPER CONDUCTOR, 600 VOLT THERMOPLASTIC INSULATION, RATED 90' C, INSULATED GREEN GROUNDING CONDUCTOR, AND GALVANIZED STEEL ARMOR OVER MYLAR.
C. INSTALLATION:
1. COLOR CODE WIRES BY LINE OR PHASE. COLOR CODE THE 120/208V CONDUCTORS BLACK, RED, BLUE, AND WHITE.
2. DO NOT SHARE NEUTRAL CONDUCTORS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR
EACH BRANCH CIRCUIT THAT REQUIRES A NEUTRAL.
3. USE PROPERLY SIZED INSULATED SPRING WIRE CONNECTORS WITH PLASTIC CAPS FOR ALL
CONDUCTORS #8 AWG AND SMALLER. INSTALLATION SCHEDULE: BUILDING WIRE IN RACEWAYS AT ALL LOCATIONS UNLESS OTHERWISE NOTED. PROVIDE XHHW-2 FOR FEEDERS AND IN EXTERIOR LOCATIONS.
TYPE MC CABLE MAY BE USED WHERE INDICATED ON PLANS OR FOR BRANCH CIRCUIT WIRING IN DRY, INTERIOR LOCATIONS OTHER THAN HOMERUNS. HOMERUNS SHALL BE BUILDING WIRE IN RACEWAY.
26 05 33 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS
A. SUBMITTALS: NONE REQUIRED FOR THIS SECTION.
B. MATERIALS
1. ELECTRICAL METALLIC TUBING CONDUIT (EMT): ANSI C80.3. GALVANIZED TUBING. FITTINGS AND CONDUIT BODIES: ANSI/NEMA FB 1; STEEL OR MALLEABLE IRON, COMPRESSION TYPE OR SET
SCREW FITTINGS WITH INSULATED THROAT BUSHINGS. DIE-CAST FITTINGS ARE NOT ACCEPTABLE.
MAXIMUM SIZE SHALL BE 2". PROVIDE FACTORY ELBOWS ON SIZES 1-1 /2" AND LARGER.
2. PROVIDE GALVANIZED OR CADMIUM PLATED, ONE PIECE PRESSED STEEL OUTLET
BOXES 4 INCH SQUARE OR OCTAGONAL, 1-1 /2 INCHES DEEP MINIMUM SIZE FOR USE IN INTERIOR
AREAS.
3. FOR TELECOMMUNICATIONS SYSTEMS, OUTLET BOXES SHALL BE 4 INCHES SQUARE,
2-1 / 4 INCHES DEEP MINIMUM.
C. INSTALLATION:
1. INSTALL CONDUIT FOR ALL SYSTEMS UNLESS OTHERWISE NOTED, 1/2 INCH
MINIMUM SIZE, EXCEPT CONDUIT FOR SPECIAL SYSTEMS SHALL BE 3/ 4” MINIMUM.
2. INSTALL RACEWAYS PER THE LATEST NECA (NATIONAL ELECTRICAL CONTRACTOR'S
ASSOCIATION) STANDARDS.
3. PAINT ALL EXPOSED CONDUIT IN FINISHED AREAS TO MATCH SURFACE TO WHICH
IT IS ATTACHED OR CROSSES. CLEAN GREASY OR DIRTY CONDUIT PRIOR TO PAINTING IN ACCORDANCE
WITH PAINT MANUFACTURER'S INSTRUCTIONS.
4. INSTALL RACEWAYS LEVEL AND SQUARE TO A TOLERANCE OF 1/8 INCH PER 10 FEET. ROUTE EXPOSED RACEWAYS AND RACEWAYS PARALLEL AND PERPENDICULAR TO WALLS, CEILING, STRUCTURAL
MEMBERS AND ADJACENT PIPING.
5. ALL CONDUIT FOR THE TELECOMMUNICATIONS DISTRIBUTION SYSTEM SHALL BE INSTALLED
WITH NO MORE THAN 270 DEGREES OF BENDS BETWEEN PULLBOXES. PULL BOXES SHALL NOT BE USED
IN LIEU OF CONDUIT BENDS. CONDULETS (LB FITTINGS) SHALL NOT BE INSTALLED IN ANY
TELECOMMUNICATIONS RACEWAY.
6. PROVIDE OUTLET BOXES AS SHOWN ON THE DRAWINGS, AND AS REQUIRED FOR
SPLICES, TAPS, WIRE PULLING, EQUIPMENT CONNECTIONS, DEVICE INSTALLATION AND CODE
COMPLIANCE.
7. USE MULTIPLE-GANG BOXES WHERE MORE THAN ONE DEVICE ARE MOUNTED TOGETHER; DO
NOT USE SECTIONAL BOXES.
8. SUPPORT BOXES INDEPENDENTLY OF CONDUIT. COORDINATE MOUNTING HEIGHTS AND
LOCATIONS OF ALL OUTLETS.
26 05 53 - IDENTIFICATION FOR ELECTRICAL SYSTEMS
A. SUBMITTALS: NONE REQUIRED FOR THIS SECTION.
B. MATERIALS:
1. TAPE LABELS: ADHESIVE TAPE LABELS, WITH 3/16 INCH BOLD BLACK LETTERS ON CLEAR
BACKGROUND MADE USING DYMO RHINOPRO 5000 OR EQUAL LABEL PRINTER.
2. WIRE AND CABLE MARKERS: CLOTH MARKERS, SPLIT SLEEVE OR TUBING TYPE.
C. INSTALLATION:
1. CONDUITS: MARK ALL CONDUITS ENTERING OR LEAVING PANELBOARDS WITH INDELIBLE BLACK MAGIC MARKER WITH THE CIRCUIT NUMBERS OF THE CIRCUITS CONTAINED INSIDE. LABEL FEEDER
CONDUITS AND SPARE CONDUITS AT EACH END WITH SOURCE AND TERMINATION POINT.
2. JUNCTION BOXES: MARK ALL CIRCUIT NUMBERS OF WIRING ON ALL JUNCTION BOXES WITH
SHEET STEEL COVERS. MARK WITH INDELIBLE BLACK MARKER. ON EXPOSED JUNCTION BOXES IN PUBLIC AREAS, MARK ON INSIDE OF COVER. MARK ALL OTHER SPECIAL SYSTEM JUNCTION BOXES WITH SHEET
STEEL COVERS.
3. WIRE IDENTIFICATION: PROVIDE WIRE MARKERS ON EACH CONDUCTOR IN PANELBOARD
GUTTERS, PULL BOXES, OUTLET AND JUNCTION BOXES, AND AT LOAD CONNECTION. MARKERS SHALL BE LOCATED WITHIN ONE INCH OF EACH CABLE END, EXCEPT AT PANELBOARDS, WHERE MARKERS FOR
BRANCH CIRCUIT CONDUCTORS SHALL BE VISIBLE WITHOUT REMOVING PANEL DEADFRONT.
4. DEVICE PLATES: LABEL EACH RECEPTACLE DEVICE PLATE OR POINT OF CONNECTION DENOTING
THE PANELBOARD NAME AND CIRCUIT NUMBER. INSTALL LABEL ON THE TOP OF EACH PLATE.
26 24 16 - LOADCENTERS
A. SUBMITTALS: SUBMIT PRODUCT DATA FOR APPROVAL.
B. MATERIAL:
1. MANUFACTURERS: MATCH EXISTING.
2. NEW BREAKERS IN EXISTING PANELS: NEMA AB 1; UL LISTED FOR USE IN THE PANEL, AMPERE RATING AND NUMBER OF POLES AS INDICATED ON PLANS. AIC RATING SHALL MATCH THE LOWEST
RATED DEVICE IN THE PANEL.
C. INSTALLATION:
1. INSTALL NEW BREAKER(S) IN EXISTING PANEL(S) AND TEST FOR PROPER OPERATION. UPDATE
CIRCUIT DIRECTORY TO REFLECT ALL CHANGES.
26 27 26 - WIRING DEVICES
A. SUBMITTALS: SUBMIT PRODUCT DATA FOR APPROVAL.
8. MATERIALS:
1. WALL SWITCHES: SWITCHES FOR LIGHTING CIRCUITS SHALL BE ANSI/NEMA WD6 AND FEDERAL SPECIFICATION FS W-S-896 AC GENERAL USE SNAP SWITCH WITH TOGGLE HANDLE, RATED 20 AMPERES
AND 120-277 VOLTS AC. HANDLE: WHITE NYLON.
2. RECEPTACLES: CONVENIENCE AND STRAIGHT BLADE RECEPTACLES SHALL BE NEMA AND
FEDERAL SPECIFICATION FS W-C-596, TYPE 5-20R, WHITE NYLON FACE. SPECIFIC USE RECEPTACLES
SHALL BE NEMA WD1 OR WD5; AS REQUIRED TO MATCH LOAD SERVED, BLACK PHENOLIC FACE.
3. WALL PLATES: DECORATIVE COVER PLATES IN FINISHED AREAS SHALL BE 430 OR
302 STAINLESS STEEL. PROVIDE 1/2 INCH RAISED, SQUARE, GALVANIZED OR CADMIUM PLATED, PRESSED STEEL COVER PLATE SUPPORTING DEVICES INDEPENDENT OF THE OUTLET BOX FOR ALL
EXPOSED WORK.
C. INSTALLATION:
1. UNLESS OTHERWISE NOTED, INSTALL WALL SWITCHES AND DIMMERS 48 INCHES ABOVE FLOOR, OFF POSITION DOWN.
2. INSTALL GALVANIZED STEEL PLATES ON OUTLET BOXES AND JUNCTION BOXES IN UNFINISHED
AREAS, ABOVE ACCESSIBLE CEILINGS, AND ON SURFACE-MOUNTED OUTLETS.
27 10 00 - STRUCTURED CABLING
A. SUMMARY: THIS SECTION INCLUDES REQUIREMENTS FOR THE DESIGN AND INSTALLATION OF A
TELECOMMUNICATIONS CABLING SYSTEM INCLUDING COMMUNICATIONS CABLE,
TELECOMMUNICATIONS JACKS, RACEWAYS, ETC. AS REQUIRED FOR A COMPLETE AND FUNCTIONAL TELECOMMUNICATIONS CABLING SYSTEM. QUALITY ASSURANCE: ALL PRODUCTS SHALL BE OF ONE
MANUFACTURER'S STRUCTURED CABLING SYSTEM. THE MANUFACTURER SHALL BE A COMPANY
SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED WITH A MINIMUM 5 YEARS
DOCUMENTED EXPERIENCE. THE INSTALLER SHALL BE A COMPANY SPECIALIZING IN PERFORMING THIS
TYPE OF WORK WITH A MINIMUM 3 YEARS DOCUMENTED EXPERIENCE AND MANUFACTURER'S
CERTIFICATION TO INSTALL THE PRODUCT. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
FOLLOWING STANDARDS: ANSI/TIA 568-8.1-3, ANSI/TIA 569_A, AND ANSI/TIA 607.
8. SUBMITTALS: SUBMIT PRODUCT DATA FOR APPROVAL.
C. MATERIALS:
1. UTP TELECOMMUNICATION CABLE: PLENUM-RATED CL2P, CATEGORY 6, 4 PAIR, 24 AWG SOLID
COPPER CONDUCTOR TELECOMMUNICATIONS CABLE. SUPERIOR ESSEX
“DATAGAIN” CMP OR APPROVED EQUAL.
2. UTP TELECOMMUNICATIONS JACK: RJ-45, CATEGORY 6, T568A/B, 8P8C, SINGLE, WHITE FINISH, TELECOMMUNICATIONS JACK WITH FLUSH EXIT WITH SINGLE-GANG
FACEPLATES WITH FINISH TO MATCH JACK. ORTRONICS #OR-TJ600 OR APPROVED EQUAL.
“ TRACJACK CLARITY 6”
3. PATCH CABLES: ALL PATCH CABLES SHALL BE FACTORY MANUFACTURED TO MATCH THE
APPLICABLE CABLE/CONNECTIVITY SOLUTION (I.E. THE BERK-TEK/ORTRONICS SYSTEM SHALL USE ORTRONICS MANUFACTURED PATCH CORDS, ETC.). PROVIDE 7-FOOT CATEGORY 6 PATCH CABLES WITH BLUE JACKET FOR INSTALLATION BETWEEN NETWORK EQUIPMENT IN THE RACK AND DEDICATED DATA PORTS IN THE TELECOMMUNICATIONS PATCH PANELS. PROVIDE ONE PATCH CABLE FOR EACH PORT IN ALL THE TELECOMMUNICATIONS PATCH PANELS. PROVIDE ONE PATCH CABLE FOR EACH DATA JACK IN
ALL THE TELECOMMUNICATIONS OUTLETS.
4. CABLE SUPPORT: ALL CABLES NOT INSTALLED IN CONDUIT SHALL BE SUPPORTED USING J-
HOOKS, CADDY CABLECAT SERIES OR APPROVED EQUAL, WITH A MINIMUM
J-HOOK SIZE EQUIVALENT TO CADDY #CAT32 OR APPROVED EQUAL. SIZE ALL J-HOOKS TO SUPPORT THE
QUANTITY OF CABLES INSTALLED, PLUS A MINIMUM OF 25% SPARE CAPACITY.
D. INSTALLATION:
1. UNLESS OTHERWISE NOTED, ALL CABLES SHALL BE INSTALLED IN CONDUIT FROM THE
TELECOMMUNICATIONS JACK TO THE SPACE BELOW FLOOR AND IN CONDUIT THROUGH INACCESSIBLE AREAS. SUPPORT CABLES INSTALLED IN CEILING SPACES WITH J-HOOKS ANCHORED TO THE FLOOR
STRUCTURE. MAXIMUM SPACING BETWEEN SUPPORTS SHALL BE 4 FEET, MAXIMUM NUMBER OF
CABLES ON EACH SUPPORT SHALL BE 25. CABLES SHALL BE ROUTED A MINIMUM OF 5 INCHES FROM POWER LINES 2 KVA OR LESS. STORE A MAXIMUM OF 12 INCHES OF SLACK CABLE AT EACH OUTLET AND A MINIMUM OF 10 FEET OF SLACK CABLE AT EACH RACK. CABLE JACKET SHALL BE MAINTAINED TO WITHIN .5 INCH OF JACK AND TWISTS SHALL BE MAINTAINED TO WITHIN .25 INCH OF TERMINATION
POINT. COMPLY WITH CABLE MANUFACTURERS MAXIMUM PULLING TENSION AND MINIMUM BEND
RADIUS REQUIREMENTS. DO NOT STRETCH, STRESS, TIGHTLY COIL, BEND OR CRIMP CABLES. CABLES
SHALL BE ROUTED SO THAT CABLE LENGTHS DO
NOT EXCEED 90 METERS PER ANSI/TIA REQUIREMENTS. PERFORM END-TO-END TESTS OF EACH CABLE AFTER INSTALLATION AND TERMINATION TO SHOW COMPLIANCE WITH ANSI/TIA REQUIREMENTS.
2. EACH UTP CABLE SHALL BE TESTED FOR COMPLIANCE WITH ANSI/TIA 568-8.1 AND ANSI/TIA
5688.2 CATEGORY 6 STANDARDS AFTER INSTALLATION USING A FLUKE #DSX OR APPROVED EQUAL TESTER. PROVIDE TEST RESULTS FOR ALL TESTS NOTED ABOVE IN THE FORM OF PRINTOUTS FROM THE TEST EQUIPMENT AND PROVIDE AN ELECTRONIC COPY OF THE TEST DATA FOR EACH CABLE. WHERE
ANY PORTION OF THE SYSTEM DOES NOT MEET THE SPECIFICATIONS, THE CONTRACTOR SHALL
CORRECT THE DEVIATION AND REPEAT ANY APPLICABLE TESTING AT NO ADDITIONAL COST TO THE OWNER. ACCEPTANCE OF THE TELECOMMUNICATIONS SYSTEM SHALL BE BASED ON THE RESULTS OF
THE ABOVE TESTS, FUNCTIONALITY, AND THE RECEIPT OF DOCUMENTATION.
KETCHIKAN
LOCATION
PROJECT
JUNEAU
WHITEHORSE
SITKA
Beaufort Sea
CANADA
UNITED STATES OF AMERICA ALASKA
BARROW
KOTZEBUE ALASKA
FAIRBANKS
SUTTON
PALMER
Gulf of Alaska
Pacific Ocean
SEWARD
KENAI
ANCHORAGE
Pt. MacKENZIE
KODIAK
KODIAK ISLAND
DILLINGHAM
BETHEL EAGLE RIVER
N
E
S
W
NO SCALE
C.I.S.
Pacific Ocean
Bering Sea
NOME
Chukchi Sea
DRAWING INDEX
Arctic Ocean
CANADA
Design Electrical Distribution System for Curatorial Displays Russian Bishop House
Sitka National Historical Park
Anchorage, AK 99503 Phone (907) 276-0521 Fax (907) 276-1751
670 Fireweed Lane, Suite 200
MECHANICAL AND ELECTRICAL CONSULTING ENGINEERS
Engineering, Inc.
ASR
CO
NS
TR
UC
TI
ON
D
OC
UM
EN
TS
SKAGWAY
SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
SITKA NATIONAL HISTORIC PARK -
RUSSIAN BISHOP HOUSE2023.05.11
188282
229199B
OF 4
5/12/23
CK
CK
SB
E001
ELECTRICAL LEGEND AND
CONSTRUCTION DOCUMENTS
SPECIFICATIONS
LEGEND
SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
SITKA NATIONAL HISTORIC PARK -
RUSSIAN BISHOP HOUSE2023.05.11
188282
229199B
OF 4
5/12/23
CK
CK
SB
E101
BASEMENT ELECTRICAL PLAN
CONSTRUCTION DOCUMENTS
1 ELECTRICAL DEMOLITION PLAN - BASEMENT
1/4" = 1'-0"
GENERAL NOTES SHEET NOTES
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
SITKA NATIONAL HISTORIC PARK -
RUSSIAN BISHOP HOUSE2023.05.11
188282
229199B
OF 4
5/12/23
CK
CK
SB
E201
FIRST FLOOR ELECTRICAL PLAN
CONSTRUCTION DOCUMENTS
1 FIRST FLOOR ELECTRICAL PLAN
1/4" = 1'-0"
GENERAL NOTES SHEET NOTES
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
SITKA NATIONAL HISTORIC PARK -
RUSSIAN BISHOP HOUSE2023.05.11
188282
229199B
OF 4
5/12/23
CK
CK
SB
E301
ELECTRICAL CALCULATIONS
CONSTRUCTION DOCUMENTS
AND ENLARGED PLANS
1 BASEMENT ELECTRICAL AREA
1/2"=1'-0"
ENLARGED FLOOR PLAN-
SCENE 2
RUSSIAN EXPLORATION
AND TRADE
SCENE 3
FRONTIER
FOUNDATIONS
SCENE 1
ORIENTATION
AND
INTRODUCTION
SCENE 6
THE LEGACY
OF RUSSIAN
AMERICA
SCENE 5
THE END OF
RUSSIAN
AMERICA ERA
4.1
THE PLACES
OF RUSSIAN
AMERICA
4.2
BUILDING A
COLONY
4.5
TEMPORARY
EXHIBITS
SCENE 4
IN RUSSIAN
AMERICA
4.4
RUSSIAN RELIGION
AND EDUCATION
4.3
SUPPLYING
THE COLONY
CLOAKROOM
SHEET # :
REVISED:
C O
PY
R
IG
H
T
AL
L R
IG
H
TS
R
ES
ER
VE
D
C
AP
IT
O L
EX
H
IB
IT
S
ER
VI
C
ES
, I
N C
SCALE:
CAPITOL EXHIBIT
SERVICES, INC.
iS eC www.capitolexhibit.com
DRAWN BY:
CHECKED BY:
PROJECT
MANAGER:
DRAWING STATUS:
NOT FOR
CONSTRUCTION
APPROVED FOR
PRODUCTION
DATE:
JOB # :
NOTES / COMMENTS:
SHEET TITLE:
PROJECT:
CLIENT:
PH: 703-330-9000
FAX: 703-330-5551
12299 LIVINGSTON ROAD
MANASSAS, VA 20109
COPYRIGHT:
THIS DRAWING IS THE PROPERTY
OF CAPITOL EXHIBIT SERVICES, INC.
AND IS NOT TO BE REPRODUCED,
NOR THE CONTENT DISCLOSED TO A
THIRD PARTY WITHOUT PERMISSION
IN WRITING FROM CAPITOL EXHIBIT
SERVICES, INC.
EXHIBIT ELECTRICAL
LOCATION PLAN
A0.10
01.16.23
22-571
RUSSIAN BISHOP'S
HOUSE
SITKA NATIONAL
HISTORICAL PARK
NATIONAL PARK
SERVICE
wlb/sc bw dm
REV1 - ADDITION OF AMP
REQUIREMENTS AT EACH
AV LOCATIION
AS NOTED
02.07.23 wlb
0.10 exhibit electrical connections plan
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
SCALE: 1/4"=1'
AutoCAD SHX Text 1'
AutoCAD SHX Text
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text
ST-02.03-612
AutoCAD SHX Text
ST-02.01-610
AutoCAD SHX Text
ST-02.02-611
AutoCAD SHX Text
ST-03.01-621
AutoCAD SHX Text
ST-03.02-622
AutoCAD SHX Text
ST-03.01-620
AutoCAD SHX Text
VISITOR CONTACT DESK
AutoCAD SHX Text
PASSPORT STATION AND DONATION BOX
AutoCAD SHX Text
ST-04.01-630
AutoCAD SHX Text
ST-04.01-631
AutoCAD SHX Text
TACTILE EXHIBIT PLANS
AutoCAD SHX Text
ST-01.02-601
AutoCAD SHX Text
ST-01.02-600
AutoCAD SHX Text
ST-01.02-602
AutoCAD SHX Text
ST-04.05-639
AutoCAD SHX Text
CONSTRUCTION INTERACTIVE
AutoCAD SHX Text
TACTILE DEVILS CLUB
AutoCAD SHX Text
ARTIFACT CASE
AutoCAD SHX Text
MAIN TEXT RAIL
AutoCAD SHX Text
ST-04.03-635
AutoCAD SHX Text
ST-04.03-632
AutoCAD SHX Text
ST-04.03-633
AutoCAD SHX Text
ST-04.03-634
AutoCAD SHX Text
ST-04.04-636
AutoCAD SHX Text
ST-04.04-637
AutoCAD SHX Text
ST-04.04-638
AutoCAD SHX Text
ST-06.01-650
AutoCAD SHX Text
ST-05.02-641
AutoCAD SHX Text
ST-05.01-640
AutoCAD SHX Text
PLAN KEY
AutoCAD SHX Text
NEW POWER SUPPLY ACCESS POINT
AutoCAD SHX Text J
AutoCAD SHX Text
APPROXIMATE LOCATION OF EXISTING JUNCTION BOXES UNDER FLOORING.
AutoCAD SHX Text ST-04.01-631 APPROXIMATE 4 AMPS POWER REQUIRED POWER / 43" NEC MONITOR POWER / BRIGHTSIGN PLAYER
AutoCAD SHX Text ST-03.02-622 APPROXIMATE 4 AMPS POWER REQUIRED POWER / BRIGHTSIGN PLAYER POWER & DATA / MOLITOR SPEAKER POWER & DATA / AMPLIFIER
AutoCAD SHX Text ST-02.02-611 APPROXIMATE 4 AMPS POWER REQUIRED POWER / BRIGHTSIGN PLAYER POWER / ULTRASONIC SPEAKER w/ MOTION DETECTION DATA CABLE / POWER SWITCH-A/C
AutoCAD SHX Text ST-06.01-650 APPROXIMATE 4 AMPS POWER REQUIRED POWER / 43" NEC MONITOR POWER / BRIGHTSIGN PLAYER
AutoCAD SHX Text ST-04.04-636 APPROXIMATE 4 AMPS POWER REQUIRED POWER / BRIGHTSIGN PLAYER POWER / ULTRASONIC SPEAKER w/ MOTION DETECTION DATA CABLE / POWER SWITCH-A/C
SITKA NATIONAL HISTORICAL PARK
SITKA, ALASKA
OPERATION AND MAINTENANCE MANUAL
RUSSIAN BISHOP'S HOUSE
APRIL 1989
EEi PROJECT NO. H8239A
PREPARED FOR:
NATIONAL PARK SERVICE
U.S. DEPARTMENT OF INTERIOR
DENVER SERVICE CENTER
UNDER
A/E CONTRACT NO. CX-2000-8-0029
PREPARED BY:
ENGINEERING ECONOMICS, INC.
17301 WEST COLFAX AVENUE, SUITE 135
GOLDEN, COLORADO 80401
(303} 279-6900
Engineering Economics, Inc. • 17301 West Colfax Avenue • Suite 135 • Golden, Colorado 80401 • (303) 279-6900
SYMBOL LEGEND
!61 P-35 SHALLOW HOUSING, & TRIM-PRE-WIRED 75W HOUSING, MANUF.
BY: PROGRESS LIGHT f/P6673. WHITE STEP
BAFFLE WITH 50W R-20 BULB. 5-7 /8" DIA TRIM
@ PRE-WIRED LOWBOY EYEBALL & HOUSING MANUF BY: PROGRESS
LIGHT #f'6976, WHITE. 8-1/4" DIA. TRIM WITH
50W R-20 BULB
@ ADJUSTABLE SPHERE MANUF. BY: PROGRESS LIGHT #f'6269, WHITE WITH 75W R 30 BULB
@ MANUF. BY: LIGHTOLIER, #6701 WHITE, 10-1 /2" DIA x 5-7 /8" HT. WITH
2-60W A19 BULBS
QE EMERGENCY LIGHT, EXIDE ELECTRONICS, MODEL #H1212 BLACK, 12W12V
HALOGEN LAMP, WITH MP-1 MOUNTING PLATE
!EJ MANUF. BY: LIGHTOLIER, #4428, WHITE, 17" DIA x 8" HT. CORD
SUPPORT WITH CEILING TRIM, WITH (3) 60W BULBS
@ MANUF. BY: -LIGHTOLIER, #4730, WHITE, 8" x 4-1/2" x 4-3/8", 'MTH
60W A19 BULB
@ EXISTING RECESSED SOFFIT LIGHT, PROGRESS flP6921, 'MTH 75W R-30 LAMP
QK MANUF. BY: LIGHTOLIER, #7158 DARK BROWN, MONOPOINT 5-3/8" DIA
'MTH 150W PAR 38 LAMP
Q KD MANUF. BY: LIGHTOLIER #7158 DARK BROWN, MONOPOINT 5-3/8" DIA
INDIVIDUAL SWITCH WITH 150W PAR 38 LAMP
fil MANUF. BY: LIGHTOLIER, #4729, 8" x 4-1/2" x 4-3/8", WHITE GLOBE
'MTH 60W A 19 BULB
@ CAST CEILING FlffiR FIXTURE, MANUF. BY: MARCO #f35N 'MTH
60W A19 BULB
@ SAME AS TYPE "A" RECESSED IN STAIR SOFFIT
[I] MANUF. BY: GUTH CO. f/M4400/120, 15-1/2" x 56-13/16" x 4-1/4' 'MTH
(2) 40W T-12 FLUORESCENT LAMPS DUO-LINER, 10% UPLIGHT.
WHITE REFLECTORS, WHITE WIRE-GUARD #4418, CADMIUM PLATED.
HINGED, 48" LONG
@ MANUF. BY: KEENE LIGHTING, STONCOLINE #CTA-510, 'MDE BEAM, MAffi BLACK, 'MTH 500W T-3 TUNGSTEN HALOGEN BULB
I s I
-v <p s.
SJ
D
LOW VOLTAGE FIXTURE, MANUF. BY: HALO #L2761 W/ #L1973
MONOPOINT BASE
MANUF. BY: LPI #W1450-R240, TRIMWOOD SURFACE FLUORESCENT
FIXTURE WITH 2-F 40T12 RAPID START LAMPS
JUNCTION BOX
FLOOR RECEPTACLE
DUPLEX RECEPTACLE
TELEPHONE OUTLET
SPECIAL RECEPTACLE
WALL S'MTCH, LEffiR INDICATES FIXTURE S'MTCHED
THREE-WAY SWITCH
DIMMER
EXJT SIGN
OPERATION & MAINTENANCE MANUAL
RUSSIAN BISHOP'S HOUSE
SITKA NATIONAL HISTORICAL PARK
FIGURE 5.8a
SYMBOL LEGEND
5-14~~~~~~
--- 1/;;""'~~==============<iEE ----------, i I
• ! M r I I
I d I '----------~
~I
E
M
?4 r
E
-~3
~ M z r-· I I I I
I i
PREHEAT
COIL
: I I:
CRAWL SPACE AND BASEMENT
: i ~~====:::::'.J
NOOlH EAST
WM!. WAU.
4 0 4
Wlllll
[&]l!IIZI rn---tow IQ.TAG:
)l')jJl 3 KVA '--'5 KVA JI XfllR
SOOlH
WM!.
~ 120/208
PANEL LAYOUT DETAIL
NOT TO SCALE
HVAC
\lJCT
(NORTH) (SOUTH)
-- LIGHTS IN CRA\\I.SPACE (1'1P.)
0 b
._. -- 30A/3P DISCONNECT
-;--t--- S\\ITCH '01'
1P NOT USED
P-1 P-2
DISCONNECT SWITCH 'D 1' DETAIL
NOT TO SCALE
L SEE PANEL LAYOUT
DETAIL THIS SHEET
AND FlGURE 5.3
NOTE: J1 THRU J19 JUNCTION BOXES
MOUNTED ON UNDERSIDE OF FIRST
FLOORING FOR EXHIBIT POWER.
OPERATION & MAINTENANCE MANUAL
RUSSIAN BISHOP'S HOUSE
SITKA NATIONAL HISTORICAL PARK
FIGURE 5.8b
CRAWLSPACE & BASEMENT
5-15
TO CRAWL
SPACE
I I I I
I 1 ! P-10{PART)
! I
:iL~ji
EXHIBIT CASE (TYP.)
I J-BOX IN CRA I'll SP ACE (TyP.)
WP P-10 (PART)
P-22 (PART)
R
@SWITCH Se
,S\'i1TCH Sh Gl) @
Sl'i1TCH se~
I TO EMERGENCY
i I UGHTING SYSTEM ! I ! 107 I
PANEL "8"
FIRST FLOOR ELECTRICAL PLAN
4 0 4 8 12
OPERATION & MAINTENANCE MANUAL
RUSSIAN BISHOP'S HOUSE
SITKA NATIONAL HISTORICAL PARK
FIGURE 5.8c
FIRST FLOOR
L__~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~.,___~~~~~~~ 5-16 ~~~~~~-I
| SOW A |
| 5 CD Electrical Russian Bishop House Sitka NPS |
| Sheets and Views |
| M0341 cover-Layout1 |
| M3041_ESERIES-E0.1 |
| M3041_ESERIES-E1.1 |
| M3041_ESERIES-E2.1 |
| M3041_ESERIES-E3.1 |
| 6 supplemental design report Revised A0.10_r1_02.07.23 |
| Sheets and Views |
| A0.10 |
| 7 supplemental design report SITK_RBH_OMMANUAL Electrical As-built |
| 9 Categorical Exclusion Doucmentation Form (CE Form) |
File details come from the government source that posted it. Updated .