Statement of Work
3,000-Gallon Live Fish Distribution Tank
United States Fish and Wildlife Service Quinault National Fish Hatchery-
Humptulips, Wa 98552
June 3rd 2022
1. General.
The contractor shall furnish and mount a 3,000-Gallon Live Fish Distribution Tank for Quinault National Fish Hatchery – Humptulips, Wa. Tank shall be completed within 190 Calendar Days
ARO.
2. Acronyms.
ARO After Receipt of Order AWG Gauge DOT Department of Transportation GCWR Gross Combination Weight Rating ICC Interstate Commerce Commission N/C Normally Closed OD Outside Diameter PVC Polyvinyl Chloride RMC Rigid Metallic Conduit SS Stainless Steel VDC Volts Direct Current
3. General Requirements.
Contractor shall engineer and fabricate a 3,000 gallon live fish transport tank which meets the minimum requirements stated below, in addition to meeting all applicable ICC Regulations.
Truck Delivery:
For the entire tank fabrication duration, the Government will provide the contractor the truck on which the tank will be fitted on. The truck is a 2023 Mack Defense 62,000-80,000 GVWR. If the contractor is within 150 road miles of Quinault National Fish Hatchery, the Government will be responsible for dropping off the truck and picking it up, with tank installed, upon completion. If the contractor is greater than 150 road miles from Quinault National Fish Hatchery, the contractor shall be responsible for picking up the truck via flatbed and the Government will be responsible for picking it up.
Material and Fabrication:
Tank system shall be a uni-body construction designed to install directly to a truck frame. Tank shall have the capacity of approximately 3,000 gallons with 4” of freeboard. Tank shall be one (1) compartment, separated by one
(1) bulkhead/baffle within the tank. Bulkhead shall have a 24” opening between the front and back compartments.
Tank shall achieve a 3,000-gallon capacity and be of 12-gauge or larger Type 304 SS interior construction. Exterior of the tank shall be skinned completely with 16-gauge or larger Type 304, #4 SS outer shell.
Top of the tank shall have one (1) 1.5” minimum thickness insulated steel door per each compartment (two (2) total).
Each door shall have a minimum access size of 36” x 36” for bodily and net access inside the tank. Each door shall have a minimum of two (2) heavy-duty SS hinges on the upstream side with bar-type latches on the downstream side. The rear hatch opening will be positioned to minimized distance to the rear of the vehicle and in consideration of routine fish loading from the rear. Doors shall be constructed so each will have the capability of folding back into the full open position to be no more than 3” from the top of the tank. An inside handle of tube construction shall be installed on the lid to allow it to be closed from the full open position. Lid gaskets shall be heat molded directly to the lids as specified.
Weight of the tank system, when fully loaded with fish, water, gas cylinders and personnel, shall not exceed the maximum legal gross weight of the truck.
All tank welding shall be to industry standards and completed in a manner that does not damage the extruded foam insulation or cause harm to live fish. Sharp edges or welds should not exist in areas where fish or human operators can make contact. Tank surfaces and welded joints should be smooth to the touch and substantially free of splatter.
Fish Discharge System:
Bottom of the tank shall be sloped from three sides towards a 16” x 12” square-to-round transition outlet. One (1) 12” discharge valve shall be a watertight shutoff knife gate valve with the handle recessed. Access panels to the 12” valve shall be removable to allow maintenance and repair without removing more skin from the outside of the tank than is necessary to access and replace / service the valve. Valve shall have ring lock couplers for a drop hose coupling and be able to attach the drop hose to additional discharge hoses as needed.
The tempering lines will be constructed of 2.5” stainless steel pipe. Tempering lines will allow for the flooding and draining of the entire tank. Inlet and outlet of drain and fill lines will be fitted with 3” Banjo brand ball valves with 3” female and male camloc couplers, respectively, whereby valves will be easily accessible.
Under tank storage release pipe compartments shall be constructed to hold two (2) 20’ x 6’ diameter pipes beside the main tank discharge tube.
Sight glasses, one on each end of the tank (two (2) total), shall have a brass shutoff valve. One (1) train valve with a 5/8” OD plexiglass tubes shall be installed on the driver’s side of the tank to ensure it’s easily reachable and drainable.
Furnish and install a transition reducer fitting from 12” ring lock to 6” male camloc, composed of stainless steel or aluminum. Transition fitting will have ease of fit/removal and smooth inner surfaces with a slope suitable for offloading of juvenile fish (likely to be eccentric) when parked on level ground. Provide 12-inch watertight ring lock cap and snap ring.
Insulation:
Entire tank and door double-wall compartments are to be tightly fitted with a minimum 1.5” thickness foam insulation. Doors and exterior of the tank shall be water tight as to prevent water from entering insulation area.
All valves, hoses and couplers shall be installed to drain completely when in the full open position to prevent damage to unit during ambient temperatures below freezing.
Oxygen System:
Oxygen distribution lines shall run from three (3) oxygen tanks, located horizontally in a storage rack on the front deck, to fit “K” and “T” bottles of compressed gas with adequate hold-downs installed to secure sagely to the deck.
All lines shall be housed in an access chase to protect from damage and allow easy inspection for leaks and repairs.
Storage rack shall be constructed so bottles are stacked three high, one over the other, with each bottle held securely in its own compartment. System shall include four (4) flow meters (1/4 to 7 LPM display), two (2) Point FourTM
MBD Air Diffusers (Part No. 1DMBDC600, from Pentair Aquatics) per compartment, and one (1) regulator for the entire oxygen system. Flow meters shall be clearly visible from the driver’s side mirror. Regulator shall be clearly visible from the passenger’s side rearview mirror.
Lines shall be routed and secured from the flowmeters to two (2) 24” Point FourTM Solid Bar Air Diffuser setups for each of the compartments (4 total). Oxygen plumbing shall be at least Schedule 40. Lines inside the tank shall be placed in recessed channels with cover plates to protect from damage when releasing adult fish. Channels shall be laid out to self-drain when tanks are emptied.
Install a 1" orifice centered in the upper 3/4 of the tank on the external tank wall facing the truck cab. Orifice should have 1" female NPT threads to receive a 1" NPT male plug. Orifice should accommodate later installation of a dissolved oxygen metering probe or other monitoring device by owner.
Electrical:
System shall include four (4) watertight type switches housed in watertight fixtures. All wiring shall be placed in RMC, be secured and be shielded. There shall be one switch per aerator and power source from the battery to aerators with 60A breakers to be installed in the battery box. All wiring shall be a minimum of 6 AWG. Switches shall be of adequate construction to supply continuous power to the aerators (i.e. 10A per unit with 20A or adequate auto-reset breaker).
Install on the oxygen manifold, one (1) pressure switch, N/C. Switch shall be wired in the cab to a red buzz / light to provide both a visual and audible warning to the driver of a low-flow or lack of sufficient oxygen pressure in the manifold. System shall include a manual toggle cutout switch to disable the system when not in use.
Install on each aerator, an 18 AWG wire from the downstream side of the aerator switch, to the cab, to a green buzz / light to show operation of the aerator for each compartment to provide both a visual and audible warning to the driver when the system fails and visual “on” light when in normal running mode. System shall include a manual toggle cutout switch to disable the system when not in use. Provide ample room in wiring conduit.
All marker lights and one (1) work lamp shall be 12 VDC. Lights / lamp shall be installed and secured to comply with DOT requirements and shall be installed in a manner which is acceptable to the truck manufacturer’s existing wiring harness.
Aeration:
Each compartment on either side of the bulkhead shall have two (2) screened breather holes with floating ball check valves for crossflow ventilation (4"). One valve shall open towards the front and one shall open towards the back of the truck to allow crossflow air circulation.
A total of 4 aerators shall be installed and made operational on the top of and protruding into the tank at approximate equal spacing relative to the tank water surface. Specifice aerators are Fresh-flo(r) Model TT (12 VDC, 75 gpm, 10 amp, 20" shaft) or as approved by Technical POC.
Other Equipment:
A 24” fold down aluminum walkway shall be installed on the driver’s side of the tank, for the full length of the tank, with heavy-duty ampli-quilt type surface. Walkway shall be completely supported from underneath. No suspension chains or cables will be acceptable. Walkway bracing shall safely support the weight of a 300-lb person.
Walkway shall have a 42” safety handrail and toe plate. Handrail shall fold over the top of the tank when in a transport position. Two (2) swinging gate-type openings shall be installed on the handrail, to swing out, located in front of the two (2) hatch openings on the tank. Walkway and handrail shall include a pneumatic lift assist system.
Ladders, front and rear deck, shall be installed to gain access from both sides of the front deck. One (1) fold down ladder shall be installed on the driver’s side for access to the rear deck. Ladders shall include 24”-high extension handles at the top to meet state safety standards.
Toolbox (approximately 40 cubic feet) shall be constructed of aluminum with SS doors and hinges. Total storage shall be approximately 24” x 24” x 60” construction as allowed by the wheelbase setting of the truck.
Certified DOT reflective tape shall be applied to both sides and the rear of the truck to meet DOT safety guidelines.
Warranty:
Contractor shall provide an express warranty to warrant all labor and materials for a period of 3 years after acceptance.
4. Delivery.
Tank will be fabricated and completed at the contractor’s facilities. Pickup shall be coordinated at least ten business days in advance with the Technical POC.
5. Inspection and Acceptance.
Inspection and acceptance will be determined by the Technical POC or their designee at the contractor’s facility.
Mounted tank will be water-tested and road-tested at capacity for a minimum of 10 miles and all components visually inspected with demonstrated trouble-free operation of mechanical parts prior to acceptance. Interim project inspection will also be allowed for by USFWS staff, as needed. Upon final acceptance contractor will provide directions for operation, parts and service manuals, warranty, etc.
Refer to Paragraph (a) of FAR Clause 52.212-4 for additional information for inspection and acceptance.