This document is a Statement of Work (SOW) for a federal contract opportunity. The Wake County VA Outpatient Clinic requires Mayo stands, intravenous infusion pump stands, and hamper frames for biohazardous waste collection bags to be used clinic-wide across multiple departments. The SOW provides detailed physical characteristics and technical requirements for the requested equipment.
The related federal contract opportunity is a Sources Sought announcement, with the purpose of conducting market research and obtaining information from qualified potential offerors. The NAICS code for this procurement is 339112, surgical and medical instrument manufacturing. Responses to the Sources Sought notice must include company information, business size, socioeconomic status, and qualifications to meet the requirement. Responses are due by 3:00 PM EST on Monday, November 18, 2024, to Serina Black at serina.black1@va.gov. No formal solicitation document exists at this time, and the government will not pay or reimburse any costs associated with responding to this notice.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C24625Q0180.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STATEMENT OF WORK
GENERAL: The Wake County VA Outpatient Clinic, 2700 Benson Road, Garner, NC 27529, has a requirement for Mayo stands, intravenous infusion pump stands, and hamper frames for biohazardous waste collection bags. The equipment will be utilized clinic wide across multiple departments.
BACKGROUND: The Wake County VA Outpatient Clinic has a requirement for Mayo stands, intravenous infusion pump stands, and hamper frames for biohazardous waste collection bags
PURPOSE: The Radiology Department at Wake County VA Outpatient Clinic has a requirement for this equipment to provide quality, safe patient care.
SCOPE: Wake County VA Outpatient Clinic is requesting contractors to provide brand name or equal equipment that meets or exceeds the physical, functional, and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the needs of the clinic.
PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities:
M3072 Frame, Infectious Waste Bag with Lid – R&B Wire Products 692
· Frame for an infectious waste collection bag
· Constructed from 7/8" steel tubing
· Chrome finish
· Bag lock secures liners in place.
· (4) 3" casters, two are locking
· Accommodates 30-35 gallon capacity (30 in W x 43 in H, 1.3 mil thick) biohazard waste disposable poly-liner bags
· Specify Red ABS high impact lid for biohazard/infectious waste (White comes standard)
· Accessory elevated 7" bottom shelf available to reduce bag capacity
· Quantity: 5
M4255 Stand, IV, Adjustable – Pedigo Products P-1080-6-SS
· Adjustable IV stand with 4-hook arrangement
· Corrosion resistant
· Stainless steel constructed pole, hooks, and base
· 27 Ib., 23" diameter base
· 70” to 124” Height Adjustable
· Accommodates up to 4 infusion pumps
· Pole sleeve welded to base
· (5) 3" sealed casters
· Quantity: 23
M8810 Stand, Mayo – Pedigo Products P-1066-SS
· Foot Operated Mayo Stand
· Removable 16-¼” x 21-¼” stainless steel tray for easy cleaning
· Convenient foot-pedal operated lock adjusts height from 36” to 62”
· Base designed to move under low clearance equipment with maximum stability
· All welded stainless steel construction
· 2” double ball bearing swivel casters
· 50 lbs. weight capacity (evenly distributed)
· Quantity: 22