Statement of Work (SOW) Project: Grains composition analysis for soybean, corn, and cotton: physiological and genetic evaluation
GENERAL INFORMATION
1.0 Scope of Work:
The project deals with physiological and genetic evaluation of cultivars and germplasm growing under the Southeast Area, and use this evaluation to selection the right varieties/genotypes that is tolerant, drought, and diseases under the southeast area. The objective of the research is to provide stakeholders, especially soybean growers, with information about the interaction between row-crops, especially soybean, and their environments to overcome heat, drought, and disease pressure. The vendor shall provide one NIR instrument per the description in section 3.
2.0 Background:
The main goal here is to purchase a Near-Infrared instrument such as NIRS DS3-Foss System to use it for grain composition analysis. This instrument will be installed in the Physiology lab in Crop Genetics Research Unit, Stoneville, MS. The instrument requires a couple of electrical outlets, a laboratory counter, and access to the internet. All these requirements are available in this lab.
CONTRACTOR REQUIREMENTS
3.0 Technical Requirements/Tasks:
The NIR instrument should have an optical performance across the full NIR wavelength range (from 850 to 2500 nm)
-NIR should measure, right away, soybean seed protein, oil, fatty acids (palmitic, stearic, oleic, linoleic, and linolenic), sugars (glucose, fructose, sucrose, raffinose, and stachyose)
-NIR should measure corn protein, oil/fat, and starch
-NIR should measure cotton protein and oil.
-NIR has a potential to measure amino acids in soybean in the future by creating calibration equation based on wet chemistry and NIR spectra.
-The vendor should provide a warranty for the instrument and service agreement in the future to maintain the instrument.
-The vendor should provide a high quality customer service and high quality service agreement for maintaining the instrument.
4.0 Government Furnished:
There is no furnished support required for this instrument. The instrument will be installed in room 408, fourth floor, building one, USDA-ARS, Stoneville, MS. Access to the facility during normal business operations (Monday – Friday, 7:30 AM – 4:30 PM) is provided. Access during federal holidays is restricted.