This statement of work outlines requirements for the installation of a Big Ass Fan in the supply warehouse at Moody Air Force Base. Key details include delivering and staging the fan equipment at the specified warehouse location; obtaining required electrical permits and inspections; assembling and mounting the fan kit to the building structure with safety cables per NEC wiring standards; installing and securing all cage brackets and adjusting the pivot joint; mounting the digital controller in an accessible location within 150 feet of the fan; and providing a 15-year warranty for mechanical and electrical coverage upon completion. The related federal contract opportunity is a solicitation issued by the Department of the Air Force Air Combat Command to procure a Big Ass Fan to control the interior climate of the warehouse and improve the life expectancy of over $200,000 of equipment stored on site.

View the file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Solicitation No.:

Contract No.:

Contract Title:

23d Security Forces Squadron

BigAssFan Installation

STATEMENT OF WORK

Current as of: 9 June 2023

23d Contracting Squadron Moody Air Force Base, Georgia

Contract No.:

Contract Title:

TABLE OF CONTENTS

PARAGRAPH TITLE PAGE(S)

1 DELIVERY AND STAGING 3

2 INSTALLATION 3

3 FOLLOWING INSTALLATION 3

4 UPON COMPLETION OF PROJECT 3

A. Appendix: Item List – Installation of a BigAssFan in Supply Warehouse

Contract Title:

1. DELIVERY AND STAGING

1.1 BigAssFan will be delivering and installing at the supply ware house 1111 Burma Road, Moody AFB, GA, 31699, US.

1.2 This scope applies to keeping the upwards of $200,000 amount of equipment from degrading faster by controlling the interior climate of warehouse. Equipment stored in the warehouse life expectance will greatly improve with the fans installation and use.

2. INSTALLATION

2.1. Obtain all required electrical permits and inspections.

2.2. Assemble and mount the complete fan kit to the building structure, including safety cables.

2.3. Install wiring per NEC between the power source and the onboard VFD or fan electronics board, not to exceed 250 linear ft (76.2 m) per fan. Install and wire a junction box within 5 ft (1.5 m) of the fan mounting location per NEC. If installing a Powerfoil X3.0, use an appropriately sized NEMA twistlock receptacle.

2.4. PIVOT 2.0: Attach and secure all cage brackets and adjust the pivot joint to the desired fan direction.

2.5. Install the wall-mounted digital controller to an accessible surface (column, concrete wall, or wood) within 150 ft of the fan, and run the wire connection to the variable frequency drive (VFD) (in electrical metallic tubing (EMT) conduit to eave height).

3. FOLLOWING INSTALLATION

3.1. Fan startup and operational training.

4. UPON COMPLETION OF PROJECT

4.1. Vendor will cover a 15 year warranty for mechanical and electrical.

4. APPENDICES.

Item List - Installation of a BigAssFan in Supply Warehouse