About this file
This document is a Statement of Objectives (SOO) for a conference room audio-visual system upgrade project for the 2nd Air Force (2 AF) headquarters. The key objectives are to upgrade the current audio-visual system located in building 2804 to include an LED video wall, camera system, microphone configuration, wireless touchpad controllers, ceiling speakers, a wireless keyboard and mouse, and furniture requirements such as a conference table and podium. The contractor shall provide all supplies, equipment, and labor to procure, deliver, and install the new system. The system must be APLITS approved and comply with current National Defense Authorization Act requirements. The contractor shall provide user training and remove the existing equipment. Additional electrical outlets may be required, which will be provided by the government. A separate federal contract opportunity document is included, which solicits bids for this project under Solicitation Number FA301024Q0027 by the Department of the Air Force Air Education and Training Command.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| FA301024Q00270001.pdf | ||
| QA - Conf Room AV Upgrade.pdf | ||
| Attachment 1- Room and Building Layouts.pdf | ||
| Solicitation - FA301024Q0027.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
14 Aug 2024
Statement of Objectives (SOO)
2 AF Conference Room Audio Visual System Upgrade
1. Objective: To upgrade current system located in building 2804, Headquarters for 2 AF
2. Requirement: Contractor shall provide all supplies, transportation, equipment, tools, materials, labor supervision, and management to procure, deliver, and install the audio-visual system.
*Any device that connects directly to the AFNET via wired or wireless means must be DoD APLITS approved. List can be found at https://aplits.disa.mil/processAPList.action
*All devices must be in compliance with current National Defense Authorization Act
2.1. The system shall include:
LED Video Wall approximate size 5’6” H x 10’ W that maximizes available wall space (Note: Height can be 2 to 3 inches less).
Shall have the following features:
o Display panels are rimless/seamless link together for uninterrupted video display.
o The system shall have the capability to split at least 4, but up to 6 displays to show multiple content at once from one computer. This shall be accomplished from the head of table and the podium.
o System shall support plug and play compatibility with common cables and devices.
Minimum Specifications shall include:
o Viewing Angles: 140 - 160° o Resolution: 4K o Contrast Ratio: 10,000:1 o LED Lifetime: 100,000 hrs o Power Suppl: Redundant o Color Temperature: 3,000 to 10,000 adjustable o Acoustic Noise: Fanless operation o LED Refresh Rate: 3840 Hz o Pixel Pitch: Under 1.0 mm
Camera System with 4K UHD camera, zone/auto framing, pan/tilt/zoom (PTZ), speaker tracking, and MS Teams capabilities. Shall be wall or ceiling mounted and ensure the head of the table and table members are in viewing area.
A Microphone Configuration that is mutable from touchpad controller(s) that can pick up the perimeter of the room.
Quantity (2) each, Wireless/mobile Touchpad Controllers w/Charging Station Shall have the following features:
o Minimum: 4G DDR/32GB Memory, 1920x1200FHD touch LCD Screen, quad core CPU w/2.0GHz processing or better o Controller Status: Diagnostic LEDs, health monitoring and alerts o Minimum range: 100Ft (30m) o Charging stations shall be located inside of the conference room.
Install Ceiling Speakers with discrete appearance that enables full room coverage.
Wireless Keyboard and Mouse for head of table.
2.2 Furniture requirements:
Trapezoid Conference Table capable of seating 13 (1 at head and 6 per side) o Wire management system; no wires protruding from under or top of the table o Approximate size: Trapezoid shape similar to Maximum Width 5’6” (head of table), Minimum Width 4’0” (foot of table), Length 18’0”, Height 31” o Inconspicuous Standard 120v Power plugin & USB/USB-C connections along table. 4 of each per side, 2 of each at head of table.
o Power from table to wall/floor located at foot of table (see attachment 1) o Discrete pull-out keyboard compartment for head of table
Interactive Slim Podium with Microphones (Gooseneck and Hand-Held)
Shall have the ability to do the following:
o House Government provided computer to run presentations o Plug & play option (guest laptops) o Similar to size 48” H x 24” W x 21”D o Easy to move and reposition, as needed o Same/similar/complementary finish as table o Contains all the AV connectivity ports such as HDMI in/out, USB/USB-C, Audio in/out, power sockets.
o Able to support digital switching & splitting of projection outputs over various equipment inputs.
o Fully integrate various AV devices such as computer system, touch interactive panel, projector, document visualizer, laptop, amplifier, speakers, microphones both gooseneck and hand-held. (Permanent computer provided by Government is HP ZBook Fury G10 with potential for future upgrade) o Utilization of podium to house A/V system is preferred. Additional room can be allocated if a rack needed.
Mobile Desk o Size approximately 30"W x 24"D x 30”H o Same/similar/complementary finish as table
2.3. The Contractor shall provide in person user training for approximately 10 personnel at the conclusion of installation.
2.4. The Contractor shall remove the existing projector, monitor, speakers, microphones, and wiring from old system and turn them over to the 2 AF representative.
2.5. If additional electrical outlets are required, the number and voltage shall be stated in quote.
Government will provide, if needed.
2.6. Standard Equipment Warranty.