Statement of Need Letter 23-25.docx

DOCX document 19 KB Posted

Attached to
Treadmill with Gait Analysis - Travis AFB, CA Federal contract opportunity
Solicitation number
FA442723Q0030
Issued by
Department of the Air Force Air Mobility Command

View the file

Other files for this federal contract opportunity

Other files attached to Treadmill with Gait Analysis - Travis AFB, CA, newest first.
File Type Posted
RFQ FA442723Q0030 .pdf PDF
RFQ FA442723Q0030 .pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Need for

60 HCOS/SGGF

NORAXON PhysTread Pressure Treadmill with Associated Gait Analysis Hardware/Software

Description: The Noraxon PhysTread Pressure Treadmill and accompanying hardware and software is a medical treadmill with pressure plates and synchronized visual capture that allows for running gait analysis. For DGMC beneficiaries receiving care in the FMRC Sports Medicine Clinic, use of gait analysis is a critical step in the evaluation and management of patients with running related injuries that are recurrent or failing to respond to standard therapies (rest, strengthening with Physical Therapy, oral medications, etc), as well as in their prevention following recovery. Additionally, the treadmill is used for exertion in patients in whom we evaluate with lower leg compartment pressures pre- and post-exercise in the evaluation of chronic exertional compartment syndrome. We would like this unit or an equivalent item per specifications below.

POC: Maj Knobloch, TSgt Allard, SSgt Kim

Unless determined otherwise, the vendor will provide the following:

1. Machine

1.1. Must include a treadmill with pressure plates and camera for video capture.

1.2. The system must have hardware and software interface that receives input from the force or pressure plates measuring impact variables to include a foot pressure map, center of pressure maps, force amplitudes during gait phases, and gait phase/spatial/time parameters during running that then matches with video obtained through camera capture.

1.3. Must display data at all times to provide easy access and adjust parameters for efficient customization.

1.4. AC Electrical Requirements

1.4.1. Input Voltage – Domestic: 208V AC3~N/PE 50/60 Hz

1.4.2. Maximum Input Current: 15-16A fuse

1.5. Warranty Coverage

1.5.1. Manufacturer warranty of 1 year

1.6 Delivery to be 30 days after contact award

2. Point of Contact after the contract is awarded:

2.1. Coordinate with Mr. Daniel R. Dettwiler at DGMC at 707-423-3751.

3. Qualifications/Certifications: N/A.

Version 3 Effective 22 February 2023

File details come from the government source that posted it. Updated .