Statement of Need - FireBox.pdf
PDF 115 KB Posted
- Attached to
- Fire Box - Presolicitation/Sources Sought
- Solicitation number
- Not on record
About this file
This document is a Statement of Objectives (SOO) for a burn trainer acquisition by Offutt Air Force Base Fire & Emergency Services.
Offutt AFB seeks to purchase a burn box trainer that provides realistic, consistent training in thermal imaging, ventilation, tactical fire attack, and fire behavior in compliance with NFPA 1801, 1403, and 1700 standards. The trainer must feature a 2-story design with a 1-story garage, both with ventilatable roofs, constructed from ceramic-coated steel. The 2-story portion should measure approximately 3' W x 2.75' D x 3' T at the peak, while the 1-story garage should be approximately 1.75' W x 2' D x 2' T. The prop must include multiple operational doors and windows, methods for isolating interior spaces and reconfiguring interior layouts, a portable metal stand for eye-level use (approximately 4'), a swivel bar with lifting crank, assembly tools, a prop pike pole, water application method, fuel loads, instructor reference materials, and thermal imaging guides. Additionally, the vendor must provide a comprehensive train-the-trainer course covering prop operation, operational capabilities, fire behavior dynamics, and practical thermal imaging applications in firefighting. All training materials will be delivered on an external drive for ongoing reference and instruction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Presolicitation Notice - Fire Box.pdf | ||
| Sources Sought Notice - Fire Box.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Burn Trainer
1. Offutt AFB Fire & Emergency Services is seeking to purchase a burn box trainer capable to providing training to firefighters to meet the intent of NFPA 1801, 1403, and 1700 for realistic, consistent training in thermal imaging, ventilation, tactical fire attack, and fire behavior. The training prop must be capable of providing both one- and two-story burns, be capable of changing interior configurations by the instructor, have multiple burn chambers, with operable doors and windows and methods to isolate interior spaces. Have a garage space which is also able to be ventilated on the roof.
2. The prop must have the following features:
a. 2-story design with 1-story garage with both roofs being able to be ventilated constructed from ceramic coated steel
b. The two-story portion of the burn prop should be approximately 3’ W x 2.75’ D x
3’ T at the peek
c. The one-story garage should be approximately 1.75’ W x 2’ D x 2’ T
d. Multiple operational doors/ windows
e. Methods for isolating interior spaces and changing interior configuration
f. Portable metal stand allowing prop to be used at eye level (approx. 4’)
g. Swivel bar with lifting crank
h. All required assembly tools
i. Prop pike pole, water application method
j. Fuel loads
k. Instructor reference materials
l. Thermal Imaging Guides
3. The vendor will provide a train-the-trainer course providing in-depth review of how to use the prop, its operational capabilities, fire behavior dynamics, and practical applications of thermal imaging in firefighting. An external drive with all train-the-trainer files will be provided.